Central Venous Access Catheter Placement Using the Sonic Flashlight
An observational study of Catheterization, Central Venous, run by University of Pittsburgh at 1 site in United States.
Trial summary
The investigators have developed a new device for guiding invasive procedures with ultrasound (US), which they call the sonic flashlight (SF). They attach a half-silvered mirror and a small flat-panel monitor directly to an ultrasound transducer to project a virtual image of the US scan into its actual location within… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Catheterization, Central Venous
- How many people
- 150 participants
- Where
- 1 siteUnited States
- Study dates
- Start not givento Dec 2006
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Adult, Older adult
Who may be able to join
- Subjects must be 18 years of age or older
- The subjects will be patients already coming to interventional radiology services at University of Pittsburgh Medical Center (UPMC)-Presbyterian to have a CVA line placed.
- The racial, gender, and ethnic characteristics of the proposed subject population reflects the demographics of Pittsburgh and the surrounding area and/or the patient population of the University of Pittsburgh Medical Center.
Who cannot join
- Once 50 patients needing a particular insertion site have participated, no further recruiting will be done for patients needing the same insertion site.
- No exclusion criteria shall be based on race, ethnicity, gender, or HIV status.
Trial locations and contacts
1 site in 1 country.
United States1 site
University of Pittsburgh
Pittsburgh, Pennsylvania, 15261
About this study
Official title: Central Venous Access Catheter Placement by Interventional Radiologists Using the Sonic Flashlight for Real Time Ultrasound Guidance
The investigators have developed a new device for guiding invasive procedures with ultrasound (US), which they call the sonic flashlight (SF). They attach a half-silvered mirror and a small flat-panel monitor directly to an ultrasound transducer to project a virtual image of the US scan into its actual location within the patient. This permits the operator to guide a needle through the skin by aiming directly at the image, using natural hand-eye coordination rather than looking away from the patient at a conventional display. The device requires no tracking or head-mounted apparatus, and provides an intuitive merger of the visual exterior of the patient with an in situ ultrasound image, which can be simultaneously viewed by others assisting the operator. The investigators believe the SF will increase the accuracy, safety, and speed for a wide variety of invasive procedures, and will require less extensive training than conventional US displays.
Given the wide variety of procedures for which the SF could be used, the investigators have narrowed their focus to applying it to a single application: vascular access. They have demonstrated clinically that the SF can be used successfully to guide the placement of the peripherally inserted central catheter (PICC) lines. The research proposed here will expand this application to include the insertion of other central venous access (CVA) lines through the internal jugular vein, subclavian vein, and femoral vein. The historical approach to CVA line placements has involved the physical exam and identification of visible landmarks. With the introduction and common usage of ultrasound, it has become routine to use ultrasound guidance.
Much of the difficulty in learning conventional ultrasound (CUS) guided procedures stems from the displaced sense of hand-eye coordination that occurs when the operator looks away from the operating field to see the ultrasound display. The SF directly addresses many of these issues and therefore the investigators believe that it is well suited for this application. They have already shown that novice US users learn vascular access procedures in training phantoms more quickly using the SF than CUS. They have also shown that intravenous (IV) team nurses already proficient in CUS guided PICC lines perform vascular access in training phantoms more quickly using the SF than CUS guidance. Finally, as mentioned earlier, the investigators have shown that the SF can be used successfully to guide the placement of PICC lines. This study will test the hypothesis that the SF will successfully facilitate catheter placement in the subclavian, femoral, and internal jugular veins demonstrating equal vasculature visualization as conventional ultrasound.
Read the detailed description
We have developed a new device for guiding invasive procedures with ultrasound (US), which we call the Sonic Flashlight (SF). We attach a half-silvered mirror and a small flat-panel monitor directly to an ultrasound transducer to project a virtual image of the US scan into its actual location within the patient. This permits the operator to guide a needle through the skin by aiming directly at the image, using natural hand-eye coordination rather than looking away from the patient at a conventional display. The device requires no tracking or head-mounted apparatus, and provides an intuitive merger of the visual exterior of the patient with an in situ ultrasound image, which can be simultaneously viewed by others assisting the operator. We believe the SF will increase accuracy, safety, and speed, for a wide variety of invasive procedures, and will require less extensive training than conventional US displays.
Given the wide variety of procedures for which the SF could be used, we have narrowed our focus to applying it to a single application: vascular access. We have demonstrated clinically that the SF can be used successfully to guide the placement of the Peripherally Inserted Central Catheter (PICC) lines. The research proposed here will expand this application to include the insertion of other Central Venous Access (CVA) lines through the internal jugular vein, subclavian vein, and femoral vein. The historical approach to CVA line placements has involved the physical exam and identification of visible landmarks. With the introduction and common usage of ultrasound, it has become routine to use ultrasound guidance.
Much of the difficulty in learning conventional ultrasound (CUS) guided procedures stems from the displaced sense of hand-eye coordination that occurs when the operator looks away from the operating field to see the ultrasound display. The SF directly addresses many of these issues and therefore we believe that it is well suited for this application. We have already shown that novice US users learn vascular access procedures in training phantoms more quickly using the SF than CUS. We have also shown that IV team nurses already proficient in CUS guided PICC lines perform vascular access in training phantoms more quickly using the SF than CUS guidance. Finally, as mentioned earlier, we have shown that the SF can be used successfully to guide the placement of PICC lines. This study will test the hypothesis that the SF will successfully facilitate catheter placement in the subclavian, femoral, and internal jugular veins demonstrating equal vasculature visualization as conventional ultrasound.
- Conditions
- Catheterization, Central Venous
- Keywords
- Central Venous, Ultrasonography, Catheterization
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 May 2006 (estimated)
- Study completionDec 2006
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Catheterization, Central VenousStudies of the same condition, open and under way.
- More trials run by University of PittsburghThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Time perspective
- Prospective
- Enrolment
- 150 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University of Pittsburgh
- Sponsor type
- University, hospital or other
- Collaborators
- National Institutes of Health (NIH)
- Investigators
- George Stetten, MD/PhD, Principal investigator, University of Pittsburgh, Dept of Bioengineering
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00330590
- Sponsor's protocol ID
- 0512052
- Status last verified
- Feb 2008
- First submitted
- 26 May 2006
- Last updated
- 15 Feb 2008
- Results posted
- No
Study at a glance
From the registry record, last updated by the sponsor on 15 Feb 2008. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Central Venous Access Catheter Placement by Interventional Radiologists Using the Sonic Flashlight for Real Time Ultrasound Guidance
- ClinicalTrials.gov ID
- NCT00330590
- Acronym / sponsor ID
- 0512052
- Conditions
- Catheterization, Central Venous
- Keywords
- Central Venous, Ultrasonography, Catheterization
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 150 participants (estimated)
- Lead sponsor
- University of PittsburghUniversity, hospital or other
- Collaborators
- National Institutes of Health (NIH)
- Study completion
- Dec 2006 (actual)
- First posted
- 29 May 2006 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The investigators have developed a new device for guiding invasive procedures with ultrasound (US), which they call the sonic flashlight (SF). They attach a half-silvered mirror and a small flat-panel monitor directly to an ultrasound transducer to project a virtual image of the US scan into its actual location within the patient. This permits the operator to guide a needle through the skin by aiming directly at the image, using natural hand-eye coordination rather than looking away from the patient at a conventional display. The device requires no tracking or head-mounted apparatus, and provides an intuitive merger of the visual exterior of the patient with an in situ ultrasound image, which can be simultaneously viewed by others assisting the operator. The investigators believe the SF will increase the accuracy, safety, and speed for a wide variety of invasive procedures, and will require less extensive training than conventional US displays.
Given the wide variety of procedures for which the SF could be used, the investigators have narrowed their focus to applying it to a single application: vascular access. They have demonstrated clinically that the SF can be used successfully to guide the placement of the peripherally inserted central catheter (PICC) lines. The research proposed here will expand this application to include the insertion of other central venous access (CVA) lines through the internal jugular vein, subclavian vein, and femoral vein. The historical approach to CVA line placements has involved the physical exam and identification of visible landmarks. With the introduction and common usage of ultrasound, it has become routine to use ultrasound guidance.
Much of the difficulty in learning conventional ultrasound (CUS) guided procedures stems from the displaced sense of hand-eye coordination that occurs when the operator looks away from the operating field to see the ultrasound display. The SF directly addresses many of these issues and therefore the investigators believe that it is well suited for this application. They have already shown that novice US users learn vascular access procedures in training phantoms more quickly using the SF than CUS. They have also shown that intravenous (IV) team nurses already proficient in CUS guided PICC lines perform vascular access in training phantoms more quickly using the SF than CUS guidance. Finally, as mentioned earlier, the investigators have shown that the SF can be used successfully to guide the placement of PICC lines. This study will test the hypothesis that the SF will successfully facilitate catheter placement in the subclavian, femoral, and internal jugular veins demonstrating equal vasculature visualization as conventional ultrasound.
Detailed description
We have developed a new device for guiding invasive procedures with ultrasound (US), which we call the Sonic Flashlight (SF). We attach a half-silvered mirror and a small flat-panel monitor directly to an ultrasound transducer to project a virtual image of the US scan into its actual location within the patient. This permits the operator to guide a needle through the skin by aiming directly at the image, using natural hand-eye coordination rather than looking away from the patient at a conventional display. The device requires no tracking or head-mounted apparatus, and provides an intuitive merger of the visual exterior of the patient with an in situ ultrasound image, which can be simultaneously viewed by others assisting the operator. We believe the SF will increase accuracy, safety, and speed, for a wide variety of invasive procedures, and will require less extensive training than conventional US displays.
Given the wide variety of procedures for which the SF could be used, we have narrowed our focus to applying it to a single application: vascular access. We have demonstrated clinically that the SF can be used successfully to guide the placement of the Peripherally Inserted Central Catheter (PICC) lines. The research proposed here will expand this application to include the insertion of other Central Venous Access (CVA) lines through the internal jugular vein, subclavian vein, and femoral vein. The historical approach to CVA line placements has involved the physical exam and identification of visible landmarks. With the introduction and common usage of ultrasound, it has become routine to use ultrasound guidance.
Much of the difficulty in learning conventional ultrasound (CUS) guided procedures stems from the displaced sense of hand-eye coordination that occurs when the operator looks away from the operating field to see the ultrasound display. The SF directly addresses many of these issues and therefore we believe that it is well suited for this application. We have already shown that novice US users learn vascular access procedures in training phantoms more quickly using the SF than CUS. We have also shown that IV team nurses already proficient in CUS guided PICC lines perform vascular access in training phantoms more quickly using the SF than CUS guidance. Finally, as mentioned earlier, we have shown that the SF can be used successfully to guide the placement of PICC lines. This study will test the hypothesis that the SF will successfully facilitate catheter placement in the subclavian, femoral, and internal jugular veins demonstrating equal vasculature visualization as conventional ultrasound.
Study design
- Time perspective
- Prospective
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Subjects must be 18 years of age or older
- The subjects will be patients already coming to interventional radiology services at University of Pittsburgh Medical Center (UPMC)-Presbyterian to have a CVA line placed.
- The racial, gender, and ethnic characteristics of the proposed subject population reflects the demographics of Pittsburgh and the surrounding area and/or the patient population of the University of Pittsburgh Medical Center.
Key exclusion criteria (2 listed)
- Once 50 patients needing a particular insertion site have participated, no further recruiting will be done for patients needing the same insertion site.
- No exclusion criteria shall be based on race, ethnicity, gender, or HIV status.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Not reported in the source record.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Feb 2008.
Related trials for Catheterization, Central Venous
RecruitingObservational study
Frailty and Ultrasound-Guided Central Venous Catheterization Difficulty in Adult Cardiac Surgery Patients
Frailty, Cardiac Surgery
Enrolling by invitationObservational study
Ultrasound Guidance vs. Landmark Technique for Catheter Malposition in IJV Catheterization
Catheter Malposition, Central Venous Catheterization
Enrolling by invitationObservational study
Ultrasound Guidance vs Landmark Technique for Internal Jugular Vein Catheterization
Central Vein Catheter, Ultrasound
Not yet recruitingObservational study
Ultrasound Assessment of Internal Jugular Vein for Cannulation and Venous Pressure Prediction
Vascular Access, Elevated Jugular Venous Pressure
Active, not recruitingObservational study
Effect of Central Venous Catheterization on Brain Pressure in Acute Brain Injury Patients
Acute Brain Injury, Traumatic Brain Injury
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
George Stetten, MD/PhD principal investigator
University of Pittsburgh, Dept of Bioengineering
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Catheterization, Central Venous, run by University of Pittsburgh at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 15 Feb 2008. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Feb 2008.