AzTrials
AzTrials

Homonymous HemianopiaNCT00494676

Clinical Trial of Peripheral Prism Glasses for Hemianopia

A study testing High power (57 prism diopter) peripheral prism glasses in people with Homonymous Hemianopia, run by Alexandra Bowers at 13 sites in 2 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to evaluate the functional utility for general mobility (walking) of new high power permanent peripheral prism glasses, which provide visual field expansion device for patients with homonymous hemianopia (the complete loss of half the field of vision on the same side in both eyes). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Homonymous Hemianopia
What is being tested?
High power (57 prism diopter) peripheral prism glasses
Type of treatment
Medical device
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
73 participants
Where
13 sitesin 2 countries
Study dates
Sep 2007to Apr 2010
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • At least 18 years of age.
  • Sighted in both eyes, with monocular visual acuity (best corrected vision), of at least 20/50 in each eye.
  • Complete homonymous hemianopia of more than 3 months duration
  • Refractive error within the -5 dioptre to +5 dioptre range
  • No significant cognitive impairment
  • No history of wearing the Peli system of peripheral prisms for hemianopic field expansion (patients who have worn another type of prismatic correction for hemianopia such as yoked prisms or the Gottlieb VAS system can participate in the study)
Show all 9Show fewer
  • No physical or mental disabilities, including cognitive dysfunction, balance problems or other deficits that could impair ability to walk or use the peripheral prism spectacles.
  • Able to walk (using a cane or walker is OK) or control the movements of their own wheelchair.
  • In sufficiently good health to attend four in-office visits.

Who cannot join

  • Diagnosis of dementia
  • Diagnosis of visual neglect
  • History of seizures in the last 6 months
  • Incomplete hemianopia

Trial locations and contacts

13 sites in 2 countries.

13 sites in 2 countries

United States12 sites
  • Emory Optical Low Vision

    Atlanta, Georgia, 30322

  • UAB Center for Low Vision Rehabilitation

    Birmingham, Alabama, 35294

  • Indiana University School of Optometry, Low Vision Rehabilitation and Primary Care Services

    Bloomington, Indiana, 47404

  • Schepens Eye Research Institute

    Boston, Massachusetts, 02114

  • Illinois Eye Institute

    Chicago, Illinois, 60616

  • Academy Eye Associates

    Durham, North Carolina, 27707

  • Visual Health@Jupiter Eye Center

    Jupiter, Florida, 33458

  • Vista Center for the Blind and Visually Impaired

    Palo Alto, California, 94306

  • University of Kansas Medical Center

    Prairie Village, Kansas, 66208

  • Vision Care Specialists, P.C.

    Southborough, Massachusetts, 01772

  • NSU Oklahoma College of Optometry,

    Tahlequah, Oklahoma, 74464

  • Seven Lakes Eye Care

    West End, North Carolina, 27376

Other trials in United States

United Kingdom1 site
  • Manchester Royal Eye Hospital

    Manchester, M60 1QD

Other trials in United Kingdom

About this study

Official title: Community-based Multi-center Randomized Control Trial of Peripheral Prism Glasses for Hemianopia

The purpose of this study is to evaluate the functional utility for general mobility (walking) of new high power permanent peripheral prism glasses, which provide visual field expansion device for patients with homonymous hemianopia (the complete loss of half the field of vision on the same side in both eyes). The efficacy of real peripheral prism glasses will be assessed relative to sham peripheral prism glasses.

Read the detailed description

Patients with hemianopic field loss are unaware of objects in their blind (non-seeing) hemi-field and often experience difficulties with mobility and navigation, such as walking into obstacles on the side of the field loss. In 2000, Peli (2000) described a new peripheral-prism design of prismatic correction for hemianopia, which addresses many of the inadequacies of existing designs of hemianopic visual aids, and produces true field expansion (i.e. the simultaneously seen field is larger with the device than without). In collaboration with the Schepens Eye Research Institute (Boston, MA), Chadwick Optical Inc (White River Junction, VT) has developed a permanent form of Fresnel prism segments, which are made from an acrylic material and can be embedded in a plastic spectacle lens. These permanent prisms offer better cosmesis, optical quality and durability than the temporary 40 prism-diopter press-on Fresnel prism segments used in previous evaluations of the peripheral prism system.

In this study we will evaluate new high-power (57 prism diopter) permanent peripheral prism glasses. The study will employ a crossover design in which each participant will wear a pair of real prism glasses (high-power, 57 prism diopter) and a pair sham prism glasses (low-power, 5 prism diopters, that provide little field expansion) in counterbalanced order. The efficacy of the real prism glasses relative to the sham prism glasses will be assessed for general mobility (walking). We expect that participants will prefer the real prism glasses over the sham prism glasses as the former will be more helpful for obstacle detection when walking.

Prism glasses will be fitted by Low Vision Practitioners at community-based Vision Rehabilitation Clinics. After wearing the first pair of glasses for 4 weeks, participants will return for an in-office follow up visit, at which a questionnaire will be administered to record their experiences of wearing the glasses. The second pair of prism glasses will then be fitted. Another questionnaire will be administered 4 weeks later to record the experiences of wearing the second set of glasses.

At the end of the period of wearing the second pair of prism glasses, a clinical decision will be made as to whether the participant should continue to use the real prism glasses (e.g. if a participant finds the prism glasses helpful for obstacle avoidance when walking). For participants who continue with the prism glasses, a final telephone follow-up interview will be conducted after about 6 months.

Being tested
High power (57 prism diopter) peripheral prism glasses, Low power sham peripheral prism glasses
Keywords
Hemianopia, Mobility, Rehabilitation, Low vision
Medical subject headings
Hemianopsia, Vision, Low

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • High power (57 prism diopter) peripheral prism glassesDevice

    All patients will wear two pairs of prism glasses in a crossover design: the high power peripheral prism glasses and sham peripheral prism glasses. Each pair of prism glasses will be worn for four weeks

  • Low power sham peripheral prism glassesDevice

    Low power (5 prism dioptre) prism glasses that provide only about 2 degrees of visual field expansion.

Study groups in NCT00494676
Study groupRoleWhat they receive
Real prism glasses first, then shamExperimentalParticipants in this arm will receive high power (57 prism diopter) peripheral prism glasses in the first period of the crossover and low power sham peripheral prism glasses in the second period
Receives: Device: High power (57 prism diopter) peripheral prism glasses; Device: Low power sham peripheral prism glasses
Sham prism glasses first, then realExperimentalParticipants in this arm will receive low power sham peripheral prism glasses in the first period of the crossover and high power (57 prism diopter) peripheral prism glasses in the second period
Receives: Device: High power (57 prism diopter) peripheral prism glasses; Device: Low power sham peripheral prism glasses

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Overall Proportion Saying "Yes" to Real Prism Glasses

    At the end of each crossover period, participants were asked a yes/no question: "If the study were to end today, would you want to continue with these prism glasses (i.e. the prism glasses worn in that period)?" The primary outcome was the overall difference, across the two periods of the crossover, between the proportion of participants saying "yes" to real prism glasses and the proportion saying "yes" to sham prism glasses.

    Measured: Evaluated after 4 weeks of wearing each type of prism glasses

Secondary outcomes (3)
  1. Mobility Change Score (All Participants Who Completed Crossover)

    Perceived difficulties with mobility were quantified using a 5-point rating scale (no difficulty to extreme difficulty) for 7 situations (items) relevant to people with hemianopia, including at home, in stores, outdoors, in unfamiliar areas, in familiar areas, in crowded areas, and noticing objects off to the side when walking. The questionnaire was administered at baseline (without prisms) and after each period of the crossover. Interval scale measures of perceived difficulty with overall mobility for each participant were estimated using Rasch analysis of the responses to all seven items (Winsteps software, version 3.70.0.226). Rasch measures were expressed as logits (log odds ratios). Mobility change scores for real and sham prisms were defined as the difference in perceived difficulty relative to baseline (in logits).

    Measured: Evaluated after 4 weeks of wearing each type of prism glasses

  2. Mobility Change Score (Only Participants Who Continued Prism Wear in the Long Term)

    Perceived difficulties with mobility were quantified using a 5-point rating scale (no difficulty to extreme difficulty) for 7 situations (items) relevant to people with hemianopia, including at home, in stores, outdoors, in unfamiliar areas, in familiar areas, in crowded areas, and noticing objects off to the side when walking. The questionnaire was administered at baseline (without prisms) and after each period of the crossover. Interval scale measures of perceived difficulty with overall mobility for each participant were estimated using Rasch analysis of the responses to all seven items (Winsteps software, version 3.70.0.226). Rasch measures were expressed as logits (log odds ratios). Mobility change scores for real and sham prisms were defined as the difference in perceived difficulty relative to baseline (in logits).

    Measured: Evaluated after 4 weeks of wearing each type of prism glasses

  3. Mobility Change Score (Only Participants Who Discontinued Prism Wear in the Long Term)

    Perceived difficulties with mobility were quantified using a 5-point rating scale (no difficulty to extreme difficulty) for 7 situations (items) relevant to people with hemianopia, including at home, in stores, outdoors, in unfamiliar areas, in familiar areas, in crowded areas, and noticing objects off to the side when walking. The questionnaire was administered at baseline (without prisms) and after each period of the crossover. Interval scale measures of perceived difficulty with overall mobility for each participant were estimated using Rasch analysis of the responses to all seven items (Winsteps software, version 3.70.0.226). Rasch measures were expressed as logits (log odds ratios). Mobility improvement scores for real and sham prisms were defined as the difference in perceived difficulty relative to baseline (in logits).

    Measured: Evaluated after 4 weeks of wearing each type of prism glasses

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Jul 2007 (estimated)
  2. Study startSep 2007
  3. Primary completionJul 2009
  4. Study completionApr 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
73 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00494676
Sponsor's protocol ID
2006-016
Other IDs
R44EY014723
Status last verified
Apr 2017
First submitted
28 Jun 2007
Last updated
4 Apr 2017
Data monitoring committee
Yes

Publications

  • Peli E. Field expansion for homonymous hemianopia by optically induced peripheral exotropia. Optom Vis Sci. 2000 Sep;77(9):453-64. doi: 10.1097/00006324-200009000-00006.

    PubMed 11014672
  • Bowers AR, Keeney K, Peli E. Community-based trial of a peripheral prism visual field expansion device for hemianopia. Arch Ophthalmol. 2008 May;126(5):657-64. doi: 10.1001/archopht.126.5.657.

    PubMed 18474776
  • Bowers AR, Keeney K, Peli E. Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia. JAMA Ophthalmol. 2014 Feb;132(2):214-22. doi: 10.1001/jamaophthalmol.2013.5636.

    PubMed 24201760

Questions about this trial

What is this clinical trial studying?

A study testing High power (57 prism diopter) peripheral prism glasses in people with Homonymous Hemianopia, run by Alexandra Bowers at 13 sites in 2 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 9 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 13 sites in United States, United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 13 Sep 2013). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Overall Proportion Saying "Yes" to Real Prism Glasses (time frame: Evaluated after 4 weeks of wearing each type of prism glasses). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00494676, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Apr 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in