AzTrials
AzTrials

Heart FailurePhase 4NCT01446796

Right Ventricular (RV) Pacing in Early Post-operative Continuous Flow Left Ventricular Assist Device (LVAD)

A Phase 4 study testing Implantable Cardioverter-Defibrillator (subject's pre-existing ICD) in people with Heart Failure, run by Duke University at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Continuous right ventricular (RV) pacing demonstrates harm in patients with normal left ventricular (LV) function as well as in patients with cardiomyopathy and clinical heart failure. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Heart Failure
What is being tested?
Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)
Type of treatment
Medical device
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
3 participants
Where
1 siteUnited States
Study dates
Sep 2011to Oct 2012
Phase
Phase 4
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥ 18 years old, both men and women
  • Existing implantable cardioverter-defibrillator (ICD)
  • Referred for implantation of a continuous flow LVAD

Who cannot join

  • Permanent left ventricular epicardial defibrillator in place
  • Congenital heart disease with single ventricle physiology
  • Right ventricular assist device (RVAD) in place
  • Existing pacing indication

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Duke University Medical Center

    Durham, North Carolina, 27710

Other trials in United States

About this study

Official title: Hemodynamic and Clinical Effects of Continuous Right Ventricular Pacing in the Early Post-operative Period After Left Ventricular Assist Device Implantation

Continuous right ventricular (RV) pacing demonstrates harm in patients with normal left ventricular (LV) function as well as in patients with cardiomyopathy and clinical heart failure. However, little is known about RV pacing in patients with advanced heart failure treated with an implantable left ventricular assist device (LVAD). The univentricular support provided by contemporary continuous flow LVAD's has improved outcomes for many advanced heart failure patients, yet the incidence of RV failure in the early post-operative period following implantation is associated with significantly reduced survival and increased length of stay. Acute LVAD unloading of the left ventricle has adverse effects on RV shape and size that contribute to post-operative RV failure. By promoting RV synchrony, RV overdrive pacing may counteract these adverse mechanical alterations, improving RV systolic function and ultimately LVAD function.

The investigators will recruit all patients referred for an implantable, continuous flow LVAD at Duke University Medical Center who have an existing implantable dual-chamber cardioverter-defibrillator. Patients will be prospectively randomized into two cohorts to compare continuous right ventricular pacing vs. native ventricular conduction at equivalent heart rates. Multiple clinical outcomes will be examined over a two week period post-operatively including invasive hemodynamics, vasoactive medication use, end-organ function, RV function by Echocardiography as well as patient symptoms and functional status.

Conditions
Heart Failure
Being tested
Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)
Keywords
Ventricular assist device
Medical subject headings
Heart Failure

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)Device

    Pacing parameters set to AAI 90

  • Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)Device

    Pacing parameters set to DDD 90-100

Study groups in NCT01446796
Study groupRoleWhat they receive
Native ConductionPlacebo comparatorDevices will be programmed to continuous atrial pacing at an AAI (atrial inhibited pacing) setting with base rate 90 bpm. Patients will not receive ventricular pacing.
Receives: Device: Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)
Continuous RV PacingExperimentalDevices will be programmed to continuous dual chamber pacing at a DDD (dual chamber dual pacing) setting with base rate ≥ 90 bpm (not to exceed 100 bpm) to achieve a majority (>80%) of paced right ventricular beats
Receives: Device: Implantable Cardioverter-Defibrillator (subject's pre-existing ICD)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Length of Hospitalization

    To determine whether continuous RV pacing reduces ICU length of stay (number of days) and overall hospital length of stay (number of days) post-LVAD implantation.

    Measured: 14 days

Secondary outcomes (3)
  1. Post-operative Need for Hemodynamic / Respiratory Support

    To determine whether continuous RV pacing reduces the need for inotropic / vasoactive agents, mechanical ventilation, or other circulatory support in the early post-operative period. Measured by the number of hemodynamic and respiratory support interventions and duration of those interventions.

    Measured: 14 days

  2. Right Ventricular Function

    To determine whether continuous RV pacing improves invasive and non-invasive measures of RV function in the early period post-LVAD implantation. Measured by Pulmonary Artery catheter measures of intra-cardiac pressures and cardiac output in the ICU setting and by qualitative and quantitative Echocardiographic measures of RV function during the hospital course.

    Measured: 14 days

  3. Functional Capacity and Symptoms

    To determine whether continuous RV pacing improves functional capacity and symptoms as measured by six minute walk test and symptoms questionnaires in the early post-LVAD implantation period.

    Measured: 14 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Oct 2011 (estimated)
  2. Study startSep 2011
  3. Primary completionMay 2012
  4. Study completionOct 2012

Why it stopped: Recruitment futility

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
3 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01446796
Sponsor's protocol ID
Pro00026676
Status last verified
Feb 2015
First submitted
14 Sep 2011
Last updated
10 Mar 2015
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing Implantable Cardioverter-Defibrillator (subject's pre-existing ICD) in people with Heart Failure, run by Duke University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 10 Mar 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 7 Nov 2013). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Length of Hospitalization (time frame: 14 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Mar 2015; AzTrials last refreshed its copy on 26 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in