AzTrials
AzTrials

Coronary Artery DiseaseOSCARSNCT01519973

Optimization of SPECT Imaging

A study testing SPECT/CT processed with Evolution for CardiacTM software in people with Coronary Artery Disease, run by Ottawa Heart Institute Research Corporation at 1 site in Canada.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Single Photon Emission Computed Tomography (SPECT) is a 3D nuclear medicine imaging technique that is used extensively to study the heart and diagnose heart disease. There are three major limitations in SPECT imaging: attenuation or loss of signal, scattering of the signal in the patient tissues and resolution, where… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease
What is being tested?
SPECT/CT processed with Evolution for CardiacTM software
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
64 participants
Where
1 siteCanada
Study dates
Aug 2008to Aug 2012
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Intermediate to high risk patients with coronary artery disease who are scheduled for routine SPECT or PET perfusion imaging

Who cannot join

  • Pregnancy and breast feeding
  • Severe narrowing (stenosis) of the aortic valve
  • Severe heart failure

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • University of Ottawa Heart Institute

    Ottawa, Ontario, K1Y 4W7

Other trials in Canada

About this study

Official title: Optimization of SPECT Cardiac Imaging Through Compensation for Attenuation, Resolution Loss and Scatter - The OSCARS

Single Photon Emission Computed Tomography (SPECT) is a 3D nuclear medicine imaging technique that is used extensively to study the heart and diagnose heart disease. There are three major limitations in SPECT imaging: attenuation or loss of signal, scattering of the signal in the patient tissues and resolution, where the signal gets blurrier the further the nuclear activity is away from the camera. New software, Evolution for CardiacTM, by GE Healthcare and new cameras with computed tomography (CT) decrease the time needed for images to be obtained while maintaining image quality. Evaluation is needed before they become standard of care.

Being tested
SPECT/CT processed with Evolution for CardiacTM software
Keywords
Diagnostic imaging, Single Photon Emission Computed Tomography, Positron emission tomography, Computed tomography, Attenuation, Resolution, Scatter, Radiopharmaceutical
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SPECT/CT processed with Evolution for CardiacTM softwareRadiation

    SPECT/CT to be compared with PET/CT

Study groups in NCT01519973
Study groupRoleWhat they receive
Evaluation of technology in SPECTOtherEvaluation of the accuracy of SPECT with new technologies for attenuation correction (AC), scatter correction (SC) and resolution recovery (RR) for assessment of myocardial perfusion using Rb-82 PET as the gold standard.
Receives: Radiation: SPECT/CT processed with Evolution for CardiacTM software

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. • Determine the accuracy of myocardial perfusion assessment using SPECT with AC/SC/RR compared to Rb-82 PET.

    We are proposing a study to evaluate the accuracy of SPECT with the new technologies for attenuation correction (AC), scatter compensation (SC) and resolution recovery (RR) for the assessment of myocardial perfusion in patients with heart disease using Rb-82 perfusion PET as the gold standard for comparison.

    Measured: 2 years

Secondary outcomes (4)
  1. Determine the incremental benefit of AC/SC/RR compared to AC alone

    Measured: 2 years

  2. Evaluate the effect on accuracy of using software with RR to reduce the acquisition time to half of the standard time.

    Measured: 2 years

  3. Determine if using a registered diagnostic CT (PET) increases the accuracy of CT-based AC over the lower-quality Hawkeye CT (SPECT).

    Measured: 2 years

  4. Determine if using a single CT scan acquired at stress for attenuation correction of both stress and rest SPECT decreases the accuracy over using CT scans acquired separately at rest and stress.

    Measured: 2 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Jan 2012 (estimated)
  2. Study startAug 2008
  3. Primary completionAug 2012
  4. Study completionAug 2012

Why it stopped: Recruitment base changed due to change in clinical acquisition procedures

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
64 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01519973
Sponsor's protocol ID
HI Protocol #2008012-01H
Acronym
OSCARS
Status last verified
Apr 2017
First submitted
15 Jul 2011
Last updated
24 Apr 2017
Results posted
No
Data monitoring committee
No
Individual data sharing
No: This trial has concluded and the investigators have published from the available data.

Publications

  • Wells RG, Soueidan K, Vanderwerf K, Ruddy TD. Comparing slow- versus high-speed CT for attenuation correction of cardiac SPECT perfusion studies. J Nucl Cardiol. 2012 Aug;19(4):719-26. doi: 10.1007/s12350-012-9555-4. Epub 2012 Apr 21.

    PubMed 22527797
  • Wells RG, Soueidan K, Timmins R, Ruddy TD. Comparison of attenuation, dual-energy-window, and model-based scatter correction of low-count SPECT to 82Rb PET/CT quantified myocardial perfusion scores. J Nucl Cardiol. 2013 Oct;20(5):785-96. doi: 10.1007/s12350-013-9738-7. Epub 2013 Jun 5.

    PubMed 23737161

Questions about this trial

What is this clinical trial studying?

A study testing SPECT/CT processed with Evolution for CardiacTM software in people with Coronary Artery Disease, run by Ottawa Heart Institute Research Corporation at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 24 Apr 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: Recruitment base changed due to change in clinical acquisition procedures). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

• Determine the accuracy of myocardial perfusion assessment using SPECT with AC/SC/RR compared to Rb-82 PET. (time frame: 2 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01519973, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Apr 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in