AzTrials
AzTrials

Acquired Platelet Function DisorderNCT01648712

Platelet Function With New Pediatric Oxygenator and Heparin and Non Heparin Coating in Pediatric Cardiac Surgery

A study testing Balance surface, Carmeda heparin-coated surface and non -heparin extracorporeal pediatric device for operation in people with Acquired Platelet Function Disorder, run by Hôpital Necker-Enfants Malades at 1 site in France.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Optimal anticoagulation is mandatory during CPB in order to avoid hemostatic system activation. Platelet dysfunction is commonly observed after procedures performed under cardiopulmonary bypass (CPB). This is associated with a major risk of thrombosis and bleeding in the postoperative period. Read more about this study

Who is it for?
Ages 30 days to 5 years
Conditions the study is for
Acquired Platelet Function Disorder
What is being tested?
Balance surface, Carmeda heparin-coated surface and non -heparin extracorporeal pediatric device for operation
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
48 participants
Where
1 siteFrance
Study dates
Mar 2013to Apr 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 30 days to 5 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Infants/children (weighting less than 18 Kg) undergoing surgical repair of congenital heart defects on CPB, presenting a saturation > 85% preoperatively.

Who cannot join

  • Newborns, infants/children with Down syndrome, other syndromes or chromosomal abnormalities prematurity,
  • use of circulatory arrest,
  • expected perfusion time < 1 hour, documented coagulation disorders, use of anticoagulant or antiplatelet drugs within 48 hours of surgery, previous heart surgery and procedures requiring a return on CPB (2 or more CPB runs),
  • cyanosis defined as oxygen saturation lower than 85%.

Trial locations and contacts

1 site in 1 country.

France1 site
  • Hopital Necker Enfants Malades

    Paris, 75015

Other trials in France

About this study

Optimal anticoagulation is mandatory during CPB in order to avoid hemostatic system activation. Platelet dysfunction is commonly observed after procedures performed under cardiopulmonary bypass (CPB). This is associated with a major risk of thrombosis and bleeding in the postoperative period.

Coating of the surface has been shown to diminish these effects.Biocompatible surfaces, extracorporeal circulation technologies mimic critical characteristics of the vascular endothelium to provide thromboresistance and enhanced blood compatibility. Recently, a new physiologic non heparin coating with different functional aspects was developed as an alternative to heparin based biological coatings. This bio-passive Hydrophilic Polymer Coating Without Heparin (BalanceTM Bio-Passive surface) and pediatric oxygenation system (Affinity PixieTM Oxygenation System), is designed to mimic the natural interfaces of blood. The aim of this study is to compare the influence of a Balance - coated CPB system in pediatric use versus the Carmeda TM heparin-coated system in platelet function preservation and hemostatic activation.

Read the detailed description

Platelet dysfunction is commonly observed after procedures performed under cardiopulmonary bypass (CPB). This is associated with a major risk of thrombosis and bleeding in the postoperative period.

Coating of the surface has been shown to diminish these effects. Since the coagulation system and platelets are involved in the blood activation process, a coating might be a valuable approach to inhibit the different reactions. Improving the biocompatibility of the system by reduction of contact activation of blood elements is of significant importance, especially for neonates and infants who are more susceptible to the deleterious effects of extracorporeal circulation (ECC). Biocompatible surfaces extracorporeal circulation technologies mimic critical characteristics of the vascular endothelium to provide thromboresistance and enhanced blood compatibility. These biocompatible surfaces mitigate the foreign body response that occurs when blood comes in contact with non- endothelial surfaces.

Recently, a new physiologic non heparin coating with different functional aspects was developed as an alternative to heparin based biological coatings. This bio-passive Hydrophilic Polymer Coating Without Heparin (BalanceTM Bio-Passive surface) and pediatric oxygenation system (Affinity PixieTM Oxygenation System), is designed to mimic the natural interfaces of blood.

Being tested
Balance surface, Carmeda heparin-coated surface, non -heparin extracorporeal pediatric device for operation
Keywords
extracorporeal circuit, platelet function

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Balance surface, Carmeda heparin-coated surfaceDevice

    This study compares the influence of a Balance - coated CPB system in pediatric use versus the Carmeda TM heparin-coated system in platelet function preservation and hemostatic activation.

    Balance arm group recieved like intervention a Balance circuit

  • non -heparin extracorporeal pediatric device for operationDevice

    The carmeda arm group received like intervention the Carmeda circuit

Study groups in NCT01648712
Study groupRoleWhat they receive
Balance CircuitOther24 patients will be assigned to the Balance group , using a non -heparin extracorporeal pediatric device for operation . The intervention is to use the Balance circuit for this arm
Receives: Device: non -heparin extracorporeal pediatric device for operation
Carmeda CircuitOther24 patients will be assigned to the Carmeda group, using a coated heparin extracorporeal pediatric device for operation. The intervention is to use the Carmeda circuit for this arm. The intervention is the Carmeda circuit.
Receives: Device: Balance surface, Carmeda heparin-coated surface

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The primary endpoint will be the difference in levels of ß thromboglobulin (ß TG) at T2 (15 min after end of bypass) between the two groups.

    Assuming a reduction of 30% of ß TG in infants treated with Balance TM , a total of 64 infants, 32 on each arm, will be needed to detect a Δ = 246 (mean ß TG = 820ng/ml in group Carmeda and mean ß TG =574ng/ml in group Balance; standard deviation=300) , in the level of ß TG at T2 with a two sided p=0.05 and a power of 80%.

    Taking in to account the use of non parametric test, we estimated an increase of the calculated sample size of 15%, yielding a total sample size of 74 patients.

    Measured: six months

Secondary outcomes (1)
  1. Platelet mapping by thromboelastography (Hemoscope, Medtronic) will be performed at the following times: T0,T1,T2,T3.

    Flow cytometry will be analysed at T0, T1,T2. Fibrinogen levels, platelet count, prothrombin time, thrombin-antithrombin complex (TAT), F 1+2, PF4 , will be analysed at each time of the study.

    Differences of bleeding, and transfusion of any blood product, during the first postoperative 24 hours, will be collected.

    Analysis of differences of activation at different times, for two different temperatures, used for CPB in the two centers.

    Need of surgical review for bleeding, time of intubation, length of stay in ICU will be analyzed.

    Measured: six months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Jul 2012 (estimated)
  2. Study startMar 2013
  3. Primary completionApr 2015
  4. Study completionApr 2015

Why it stopped: for difficulty to enroll patients in the study

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
48 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01648712
Sponsor's protocol ID
Necker
Status last verified
Feb 2021
First submitted
20 Jul 2012
Last updated
12 Feb 2021
Results posted
No
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Balance surface, Carmeda heparin-coated surface and non -heparin extracorporeal pediatric device for operation in people with Acquired Platelet Function Disorder, run by Hôpital Necker-Enfants Malades at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 12 Feb 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: for difficulty to enroll patients in the study). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The primary endpoint will be the difference in levels of ß thromboglobulin (ß TG) at T2 (15 min after end of bypass) between the two groups. (time frame: six months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Feb 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in