AzTrials
AzTrials

Coronary Artery DiseasePhase 1PERCCADNCT01853410

Peripheral Stimulation Device to Improve Coronary Flow Reserve in Coronary Artery Disease

A Phase 1 study testing gekoTM in people with Coronary Artery Disease and Ischemic Disease, run by London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of the PERCCAD Study is to investigate the effect of the gekoTM device (a non-invasive calf muscle stimulator approved for use to improve blood flow by Health Canada) on coronary blood flow in order to assess its potential role as a therapeutic modality for the treatment of symptomatic coronary artery… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease, Ischemic Disease
What is being tested?
gekoTM
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
10 participants
Where
1 siteCanada
Study dates
Jul 2013to Oct 2015
Phase
Phase 1
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age 18 - 80.
  • Symptomatic coronary artery disease and already undergoing invasive angiographic assessment and percutaneous coronary intervention.

Who cannot join

  • Significant valvular heart disease or left ventricular dysfunction.
  • Contraindication to the administration of intracoronary adenosine.
  • Latex allergy.
  • Significant peripheral motor neuropathy.

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • London Health Sciences Centre

    London, Ontario, N6A5A5

Other trials in Canada

About this study

The purpose of the PERCCAD Study is to investigate the effect of the gekoTM device (a non-invasive calf muscle stimulator approved for use to improve blood flow by Health Canada) on coronary blood flow in order to assess its potential role as a therapeutic modality for the treatment of symptomatic coronary artery disease (CAD). This will occur in patients already undergoing coronary angiography and percutaneous coronary intervention (PCI) as part of their usual medical care. Further, the investigators will also assess the overall effect on blood flow in the body using non-invasive techniques. The primary objective of the PERCCAD study is to assess the effect of the gekoTM device on coronary blood flow in patients with symptomatic CAD who are undergoing invasive angiographic assessment and management with PCI. This evaluation of the gekoTM device is to be performed at the time of the patient's already planned invasive assessment and management so that invasive data can be collected without exposing the patient to risks other than those already associated with their planned procedure and usual clinical care. The secondary objective of the study is to assess the effect of muscle stimulation with the gekoTM device on endothelial function and peripheral blood flow measured via non-invasive techniques.

Read the detailed description

Angina pectoris or anginal equivalent dyspnoea are frequent symptoms related to impaired myocardial blood supply. The supply-demand imbalance that arises in the setting of coronary artery disease can be addressed by improving myocardial blood supply through mechanical revascularization with percutaneous coronary intervention or bypass surgery or by reducing myocardial energy demand through pharmacotherapy including the use of negative chronotropic agents such as beta blockers. When further revascularization is not an option, or standard therapies are insufficient to control symptoms, other novel therapies are attempted to improve myocardial blood supply and decrease angina. Enhanced external counterpulsation (EECP) devices have been demonstrated to augment cardiac performance and coronary flow and have a beneficial effect in reducing anginal symptoms in patients with CAD.(1-4) Transcutaneous (non-invasive) electrical nervous stimulation of skeletal muscle to improve venous return to the heart and provide a potential mechanism to augment and improve blood flow, including coronary flow, is a potential alternative method to achieve a similar effect,(5,6) but is less cumbersome and more easily integrated into clinical practice. The gekoTM device is a small transcutaneous nerve stimulator (weight 18g, dimensions 149mm x 42mm x 11mm) that is applied non-invasively to the skin over the common peroneal nerve in the lower limb that has been demonstrated to safely stimulate blood flow from the gastrocnemius and soleus venous system via activation of the venous 'pump' system, intrinsic to the calf muscles. As a result, the gekoTM device is approved for use in Canada to improve blood flow and is already being used in clinical practice at University Hospital. By improving venous return, this device has the potential to have a therapeutic effect in the management of CAD by augmenting coronary blood flow. The purpose of the PERCCAD Study is to investigate the effect of the gekoTM device on coronary blood flow in order to assess its potential role as a therapeutic modality for the treatment of symptomatic CAD. Further, since previous studies with EECP also demonstrated improvement in endothelial function, the investigators plan to study the effect of the gekoTM device on endothelial function and peripheral blood flow in the same patients via non invasive techniques(4, 7, 8) given the established relationship between endothelial dysfunction and cardiovascular risk. (9-12)

The primary objective of the PERCCAD study is to assess the effect of the gekoTM device on coronary blood flow in patients with symptomatic CAD who are undergoing invasive angiographic assessment and management with PCI. This evaluation of the gekoTM device is to be performed at the time of the patient's already planned invasive assessment and management so that invasive data can be collected without exposing the patient to risks other than those already associated with their planned procedure and usual clinical care. The secondary objective of the study is to assess the effect of muscle stimulation with the gekoTM device on endothelial function and peripheral blood flow measured via non-invasive techniques.

Study Design:

Single arm clinical study where patients act as their own controls (coronary flow reserve and endothelial function measured in patients already undergoing angiography and PCI) with measurements recorded pre and post application of the gekoTM device.

Coronary flow assessment: The PCI procedure will be performed according to standard practice. As part of routine practice, a guidewire is inserted into the coronary artery and used as a "rail" for delivering balloons and stents. Often, we use a special Doppler guidewire with a sensor at the tip that is used for measurements of blood flow. We will use such a guidewire for the current study (13-16). Velocity signals are obtained by the guidewire and average peak velocity (APV) is determined. Intracoronary adenosine will be given to induce hyperemia and increase coronary flow (17-21). Intracoronary adenosine is used routinely during PCI. Coronary flow reserve (CFR) will be calculated as the ratio of APV during hyperemia compared to APV at baseline. After measurement of baseline APV and CFR, we will perform two minutes of muscle stimulation using the gekoTM device at a low pulse width setting and record APV. After this, a further two minutes of muscle stimulation using the gekoTM device at a higher pulse width setting will occur with repeated APV and CFR measurements recorded. This process will be performed in at least two coronary arteries at the time of patient's usual invasive assessment and management. Calf muscle stimulation with the gekoTM device: The gekoTM device will be fitted bilaterally behind the patient's knees in the popliteal fossa. At the appropriate time the device will be set to stimulate the common peroneal nerve transcutaneously (the low setting will be set at the level at which the patient has a sensation of stimulation but where there is no visible movement of the lower leg; the high setting will be at the patient's highest tolerable level, but not lower than the level which elicited slight visible movement of the lower leg).

Endothelial Function Assessment: Endothelial function study will be performed on a separate visit following the PCI, by measurement of peripheral vasodilator response using fingertip pulse amplitude tonometry (peripheral arterial tonometry-PAT). PAT signals will be obtained with the EndoPAT2000 (EndoPAT) device (Itamar Medical Inc., Caesarea, Israel). The EndoPAT is an FDA approved device for noninvasive assessment of endothelial dysfunction, it is widely used for clinical and research purposes and validated as a method of endothelial function assessment.(22-24) Specially designed finger probes are placed on the index finger of each patient's hand. The probes are comprised of a system of inflatable latex air cuffs connected by pneumatic tubes to an inflating device controlled through a computer algorithm. There is no occlusion of arterial blood flow. Pulsatile volume changes of the distal digit induce pressure alterations in the finger cuff, which are sensed by pressure transducers and transmitted to and recorded by the EndoPAT. Endothelial function is measured via a reactive hyperemia-peripheral arterial tonometry index (RH-PAT index). A reactive hyperemia protocol consists of a 5-minute baseline measurement, after which a blood pressure cuff placed on the test arm is inflated to 60 mmHg above baseline systolic blood pressure, or at least 200 mmHg for 5 minutes. After 5 minutes, the cuff is deflated, and the PAT tracing recorded for a further 5 minutes. The ratio of the PAT signal after cuff release, compared to baseline, is calculated through a computer algorithm automatically normalizing for baseline signal, and indexed to the contra lateral arm. The calculated ratio reflects the RH-PAT index, a reflection of degree of endothelial function. This process is non-invasive and does not require percutaneous vascular access. Endothelial function will also be assessed at baseline and following 1 hour treatment with the gekoTM using the EndoPAT to calculate the RH-PAT index as described. In addition, the effect on popliteal artery vessel diameter and Doppler flow velocity will also be recorded using a surface ultrasound probe at baseline and following 1 hour of treatment with the gekoTM.

Being tested
gekoTM
Keywords
coronary artery disease, coronary flow reserve, endothelial function
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • gekoTMDevice

Study groups in NCT01853410
Study groupRoleWhat they receive
gekoTM device applicationExperimentalSingle arm study. Application of gekoTM device as described above with assessment of effect on coronary flow and endothelial function.
Receives: Device: gekoTM

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in Coronary Flow Reserve following stimulation with gekoTM device

    The change in the effect of the gekoTM device on coronary blood flow as measured by coronary flow reserve using a Doppler tipped coronary flow wire inserted into the coronary artery tree via a percutaneous technique, will be measured at baseline, after 120 sec of stimulation with the gekoTM device on low frequency setting, and after 120 sec of stimulation with the gekoTM device on high frequency setting

    Measured: Time = 0; Time = post 120 sec stimulation (low setting); Time = post 120 sec stimulation (high setting)

Secondary outcomes (3)
  1. Change in Popliteal artery vessel diameter following 60 mins stimulation with gekoTM device

    Change in popliteal artery vessel diameter will be recorded using a surface ultrasound probe at baseline and following 60 mins of treatment with the gekoTM.

    This study will be performed on a separate visit following the PCI procedure.

    Measured: Time = 0; Time = post 60 mins stimulation with gekoTM device

  2. Change in Popliteal artery vessel Doppler flow velocity following 60 mins stimulation with gekoTM device

    Change in popliteal artery vessel Doppler flow velocity will be recorded using a surface ultrasound probe at baseline and following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.

    Measured: Time = 0; Time = post 60 mins stimulation with gekoTM device

  3. Change in Endothelial function following 60 mins stimulation with gekoTM device

    The change in Endothelial function study will by measured using the EndoPAT2000 following 60 mins of treatment with the gekoTM. This study will be performed on a separate visit following the PCI procedure.

    Measured: Time = 0; Time = post 60 mins stimulation with gekoTM device

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 May 2013 (estimated)
  2. Study startJul 2013
  3. Primary completionJul 2014
  4. Study completionOct 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 1
Primary purpose
Basic science
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
10 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01853410
Sponsor's protocol ID
103661
Acronym
PERCCAD
Status last verified
Nov 2015
First submitted
8 May 2013
Last updated
26 Nov 2015
Results posted
No
Data monitoring committee
No

Publications

  • Loh PH, Cleland JG, Louis AA, Kennard ED, Cook JF, Caplin JL, Barsness GW, Lawson WE, Soran OZ, Michaels AD. Enhanced external counterpulsation in the treatment of chronic refractory angina: a long-term follow-up outcome from the International Enhanced External Counterpulsation Patient Registry. Clin Cardiol. 2008 Apr;31(4):159-64. doi: 10.1002/clc.20117.

    PubMed 18404725
  • Masuda D, Nohara R, Hirai T, Kataoka K, Chen LG, Hosokawa R, Inubushi M, Tadamura E, Fujita M, Sasayama S. Enhanced external counterpulsation improved myocardial perfusion and coronary flow reserve in patients with chronic stable angina; evaluation by(13)N-ammonia positron emission tomography. Eur Heart J. 2001 Aug;22(16):1451-8. doi: 10.1053/euhj.2000.2545.

    PubMed 11482918
  • Michaels AD, Accad M, Ports TA, Grossman W. Left ventricular systolic unloading and augmentation of intracoronary pressure and Doppler flow during enhanced external counterpulsation. Circulation. 2002 Sep 3;106(10):1237-42. doi: 10.1161/01.cir.0000028336.95629.b0.

    PubMed 12208799
  • Yang DY, Wu GF. Vasculoprotective properties of enhanced external counterpulsation for coronary artery disease: beyond the hemodynamics. Int J Cardiol. 2013 Jun 5;166(1):38-43. doi: 10.1016/j.ijcard.2012.04.003. Epub 2012 May 4.

    PubMed 22560950
  • Jawad H. The effect of a novel electrical stimulation method for improving lower limb blood flow in healthy volunteers. 2012

  • Tucker A, Maass A, Bain D, Chen LH, Azzam M, Dawson H, Johnston A. Augmentation of venous, arterial and microvascular blood supply in the leg by isometric neuromuscular stimulation via the peroneal nerve. Int J Angiol. 2010 Spring;19(1):e31-7. doi: 10.1055/s-0031-1278361.

    PubMed 22477572
  • Akhtar M, Wu GF, Du ZM, Zheng ZS, Michaels AD. Effect of external counterpulsation on plasma nitric oxide and endothelin-1 levels. Am J Cardiol. 2006 Jul 1;98(1):28-30. doi: 10.1016/j.amjcard.2006.01.053. Epub 2006 May 3.

    PubMed 16784915
  • Bonetti PO, Barsness GW, Keelan PC, Schnell TI, Pumper GM, Kuvin JT, Schnall RP, Holmes DR, Higano ST, Lerman A. Enhanced external counterpulsation improves endothelial function in patients with symptomatic coronary artery disease. J Am Coll Cardiol. 2003 May 21;41(10):1761-8. doi: 10.1016/s0735-1097(03)00329-2.

    PubMed 12767662
  • Rubinshtein R, Kuvin JT, Soffler M, Lennon RJ, Lavi S, Nelson RE, Pumper GM, Lerman LO, Lerman A. Assessment of endothelial function by non-invasive peripheral arterial tonometry predicts late cardiovascular adverse events. Eur Heart J. 2010 May;31(9):1142-8. doi: 10.1093/eurheartj/ehq010. Epub 2010 Feb 24.

    PubMed 20181680
  • Gokce N, Keaney JF Jr, Hunter LM, Watkins MT, Menzoian JO, Vita JA. Risk stratification for postoperative cardiovascular events via noninvasive assessment of endothelial function: a prospective study. Circulation. 2002 Apr 2;105(13):1567-72. doi: 10.1161/01.cir.0000012543.55874.47.

    PubMed 11927524
  • Bonetti PO, Pumper GM, Higano ST, Holmes DR Jr, Kuvin JT, Lerman A. Noninvasive identification of patients with early coronary atherosclerosis by assessment of digital reactive hyperemia. J Am Coll Cardiol. 2004 Dec 7;44(11):2137-41. doi: 10.1016/j.jacc.2004.08.062.

    PubMed 15582310
  • Hamburg NM, Keyes MJ, Larson MG, Vasan RS, Schnabel R, Pryde MM, Mitchell GF, Sheffy J, Vita JA, Benjamin EJ. Cross-sectional relations of digital vascular function to cardiovascular risk factors in the Framingham Heart Study. Circulation. 2008 May 13;117(19):2467-74. doi: 10.1161/CIRCULATIONAHA.107.748574. Epub 2008 May 5.

    PubMed 18458169
  • Gould KL, Lipscomb K. Effects of coronary stenoses on coronary flow reserve and resistance. Am J Cardiol. 1974 Jul;34(1):48-55. doi: 10.1016/0002-9149(74)90092-7. No abstract available.

    PubMed 4835753
  • Hoffman JI. Maximal coronary flow and the concept of coronary vascular reserve. Circulation. 1984 Aug;70(2):153-9. doi: 10.1161/01.cir.70.2.153. No abstract available.

    PubMed 6234109
  • Collins P. Coronary flow reserve. Br Heart J. 1993 Apr;69(4):279-81. doi: 10.1136/hrt.69.4.279. No abstract available.

    PubMed 8489855

Questions about this trial

What is this clinical trial studying?

A Phase 1 study testing gekoTM in people with Coronary Artery Disease and Ischemic Disease, run by London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 26 Nov 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 1 studies test a treatment in a small group of people for the first time or in a new way, mainly to check safety and find the right dose.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in Coronary Flow Reserve following stimulation with gekoTM device (time frame: Time = 0; Time = post 120 sec stimulation (low setting); Time = post 120 sec stimulation (high setting)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01853410, which also lists 24 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Nov 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in