VERION Versus Conventional, Manual Ink-marking in Toric IOL Implantation

A study testing VERION for toric IOL alignment and Conventional, manual ink-marking for toric IOL alignment in people with Astigmatism, run by Maastricht University Medical Center at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

OVERVIEW Cataract is a clouding of the crystalline lens which causes vision loss and blindness if untreated. Cataract surgery is the most frequently performed surgical intervention in medicine with an incidence of 880 surgeries per 100.000 population in 2010 amounting to a total number of over 160.000 surgeries per… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Astigmatism
What is being tested?
VERION for toric IOL alignment and Conventional, manual ink-marking for toric IOL alignment
Could I receive a placebo?
No, everyone receives an active treatment
How many people
34 participants
Where
1 siteNetherlands
Study dates
May 2015to Feb 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Astigmatism (at least 1.25D)
  • Cataract
  • Are at least 18 years of age
  • Eye eligible to undergo cataract extraction
  • Eye eligible for toric IOL implantation
  • Bilateral eyes: availability to undergo second eye surgery within 2 weeks of the first eye surgery
  • Willing and able to comply with scheduled visits and other study procedures
  • Understand and signed informed consent

Who cannot join

  • Irregular corneal astigmatism or keratoconus
  • Extensive age related macular degeneration (atrophic or exudative AMD or numerous soft drusen)
  • Fuchs endothelial dystrophy (stage 2)
  • Uncontrolled/manifest glaucoma
  • Glaucoma related extensive visual field loss
  • Extensive diabetic macular disease
Show all 10Show fewer
  • Previous intraocular or corneal surgery of any kind
  • Subjects presenting any contraindications to cataract surgery
  • Subjects with a recurrent or active ocular or uncontrolled eyelid disease
  • Subjects with a history of lens instability (e.g. posterior polar cataract, traumatic cataract) or zonular instability

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • Maastricht University Medical Centre

    Maastricht, Limburg, 6202 AZ

Other trials in Netherlands

About this study

OVERVIEW Cataract is a clouding of the crystalline lens which causes vision loss and blindness if untreated. Cataract surgery is the most frequently performed surgical intervention in medicine with an incidence of 880 surgeries per 100.000 population in 2010 amounting to a total number of over 160.000 surgeries per year in the Netherlands.

Approximately 22% of patients with cataract have a substantial pre-existing corneal astigmatism. Toric IOLs provide the opportunity to correct pre-existing astigmatism, offering the patients optimum distance vision without the use of spectacles or contact lenses. Toric IOLs are increasingly used in cataract and refractive surgery.

Read more

Since the introduction of toric intraocular lenses (IOLs) in the treatment of cataract in patients with pre-existing corneal astigmatism, numerous studies have shown the importance of accurate positioning of the toric IOL to the intended alignment axis. An error of 5º in toric IOL alignment will decrease the anticipated effect by 17% and thus misalignment will decrease the effectiveness of the astigmatism treatment. There are several methods used to align the toric IOL at the intended axis. Most of these use a 3-step ink-marking procedure and are performed manually. Clinical study showed an average error of 5º in toric IOL alignment when using this method.

Two new tools that have recently been introduced to the market are the VERION Measurement Module and VERION Digital Marker. Together, these tools provide integrated digital guidance for alignment of toric IOLs and they have the potential to eliminate the error in horizontal axis marking and the alignment axis marking error. This will lead to an improved visual outcome. So far, there are no published studies using the VERION tools for toric IOL alignment in cataract surgery. Therefore, the investigators will perform this randomized control trial.

MAIN HYPOTHESIS

The investigators hypothesise that cataract surgery with the implantation of a toric IOL, when using the VERION-tools, compared to manual ink-marking, in patients with corneal astigmatism will lead to:

  • An increase in accuracy in toric IOL alignment

OBJECTIVES

Primary Objective:

The primary objective of the study is to compare the accuracy in toric IOL alignment when using the VERION-tools for alignment of the toric IOL or the conventional manual ink-marking procedure.

Other hypotheses and objectives are available in the detailed description.

Read the detailed description

Extra hypotheses

  • A decrease in residual astigmatism
  • An improved best corrected distance visual acuity (BCVA)
  • An improved uncorrected distance visual acuity (UCVA)
  • A decrease in residual refractive astigmatism
  • A decrease or comparable complication profile

Secondary Objective:

The secondary objective of the study is to compare residual astigmatism when using the VERION Measurement Module and VERION Digital Marker for alignment of the toric IOL or the conventional manual ink-marking procedure.

Other Secondary Objectives:

The other secondary objectives are to compare:

  1. Best corrected distance visual acuity (BCVA)
  2. Uncorrected distance visual acuity (UCVA)
  3. Residual refractive astigmatism
  4. Wavefront aberrations
  5. Complication profile
Conditions
Astigmatism
Being tested
VERION for toric IOL alignment, Conventional, manual ink-marking for toric IOL alignment
Keywords
Toric IOL alignment, VERION digital marker, Manual ink-marking, Randomized controlled trial
Medical subject headings
Astigmatism

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • VERION for toric IOL alignmentDevice

    Also called VERION Measurement Module and Digital Marker

    The VERION Measurement Module is a diagnostic device which can make high resolution colour reference images of the patient's eye for position reference. The VERION Digital Marker is a medical device that assists the surgeon in planning and performing surgical procedures on the eye. The VERION tools use several reference points on the conjunctiva and limbus, and make an overlay between the preoperative achieved and live-surgery image. During surgery, this device projects the horizontal axis and the estimated placement axis of the toric IOL on the patient's eye, and therefore, the surgeon can accurately place the toric IOL to its preoperatively calculated angle.

  • Conventional, manual ink-marking for toric IOL alignmentProcedure or surgery

    Also called Conventional, manual ink-marking

    Several manually performed methods are used to align the toric IOL at the intended axis. Most of them use a 3-step procedure. First, the horizontal axis of the eye is temporarily marked with ink in a seated position to correct for cyclotorsion when changing into supine position. Three spots on the conjunctiva, close to the edge of the cornea, are applied at 0°, 90° and 180°, which may be done by using a bubblemarker or gravity marker with a calibrated horizontal position. Next, the desired alignment axis for the toric IOL is marked intra-operatively. The last step is to rotate the implanted toric IOL until the IOL markings agree with the alignment marks. After surgery is performed, the ink marks will disappear within a few hours.

Study groups in NCT02370953
Study groupRoleWhat they receive
VERIONExperimentalIn this group the VERION-tools (Digital Marker) are used for the alignment of the toric IOL
Receives: Device: VERION for toric IOL alignment
Conventional, manual ink-markingActive comparatorIn the group the conventional manual marking is used for the alignment of the toric IOL
Receives: Procedure: Conventional, manual ink-marking for toric IOL alignment

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Average error (in degrees) in toric IOL-axis

    Measured: at week 13 (after the first surgery, if bilateral surgery was performed).

Secondary outcomes (1)
  1. Percentage of eyes with residual refractive cylinder ≤0.5D

    Measured: at week 13 (after the first surgery, if bilateral surgery was performed).

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Feb 2015 (estimated)
  2. Study startMay 2015
  3. Primary completionJan 2016
  4. Study completionFeb 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
34 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02370953
Sponsor's protocol ID
NL51895.068.14
Status last verified
Nov 2015
First submitted
19 Feb 2015
Last updated
16 Mar 2016
Results posted
No
Data monitoring committee
Yes

Publications

  • Bauer NJ, de Vries NE, Webers CA, Hendrikse F, Nuijts RM. Astigmatism management in cataract surgery with the AcrySof toric intraocular lens. J Cataract Refract Surg. 2008 Sep;34(9):1483-8. doi: 10.1016/j.jcrs.2008.05.031.

    PubMed 18721707
  • Visser N, Berendschot TT, Bauer NJ, Jurich J, Kersting O, Nuijts RM. Accuracy of toric intraocular lens implantation in cataract and refractive surgery. J Cataract Refract Surg. 2011 Aug;37(8):1394-402. doi: 10.1016/j.jcrs.2011.02.024.

    PubMed 21782085
  • Visser N, Berendschot TT, Verbakel F, de Brabander J, Nuijts RM. Comparability and repeatability of corneal astigmatism measurements using different measurement technologies. J Cataract Refract Surg. 2012 Oct;38(10):1764-70. doi: 10.1016/j.jcrs.2012.05.036.

    PubMed 22999600

Questions about this trial

What is this clinical trial studying?

A study testing VERION for toric IOL alignment and Conventional, manual ink-marking for toric IOL alignment in people with Astigmatism, run by Maastricht University Medical Center at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 16 Mar 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Average error (in degrees) in toric IOL-axis (time frame: at week 13 (after the first surgery, if bilateral surgery was performed).). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02370953, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Mar 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in