Irregular; Contour of CorneaNCT02444923

Scleral Versus Corneal RGP Contact Lenses in Irregular Cornea Disorders

A study testing Scleral rigid gas permeable contact lenses (SRGPcl) (Zenlens™) and Corneal Rigid gas Permeable contact lenses (CRGPcl) (Rose K2) in people with Irregular; Contour of Cornea and Keratoconus, run by London South Bank University at 1 site in United Kingdom.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The most common causes for irregular cornea (IC) in hospital contact lens practice are Keratoconus (KC) and related cornea thinning disorders. These conditions cause mild to marked impairment of vision and cannot be effectively corrected by spectacles and soft contact lenses. Read more about this study

Who is it for?
Ages 18 to 69 yearsHealthy volunteers can take part
What is being tested?
Scleral rigid gas permeable contact lenses (SRGPcl) (Zenlens™) and Corneal Rigid gas Permeable contact lenses (CRGPcl) (Rose K2)
Type of treatment
Medical device
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
30 participants
Where
1 siteUnited Kingdom
Study dates
25 Oct 2015to 29 Jan 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 69 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Diagnosis of keratoconus or related corneal irregularity
  • Age 18 years to 69 years.

Who cannot join

  • Good visual quality with soft contact lenses and or spectacles

Trial locations and contacts

1 site in 1 country.

United Kingdom1 site
  • Central Middlesex Hospital

    London, NW10 7NS

Other trials in United Kingdom

About this study

Official title: A Randomised Controlled Research to Asses the Clinical Performance and Effect on Vision Related Quality of Life of Rigid Gas Permeable Scleral Versus Corneal Contact Lenses for Keratoconus and Other Irregular Cornea Disorders

The most common causes for irregular cornea (IC) in hospital contact lens practice are Keratoconus (KC) and related cornea thinning disorders. These conditions cause mild to marked impairment of vision and cannot be effectively corrected by spectacles and soft contact lenses. The gold standard in the management of KC is Corneal Rigid Gas Permeable contact lenses (corneal lenses), which correct approximately 90% of the corneal irregularity.

Compared with a normal cornea, the cornea in KC is irregular and this results in a compromise to the fit of rigid corneal lenses. Specifically, they bear on the cornea and this, together with the vulnerability of the cornea in KC, are implicated in corneal scarring, and disease progression as well as a significantly reduced vision related quality of life (QoL) in KC compared with corneal lens wearers who have no KC.

Read more

In cases where the compromise fit of corneal lenses proves problematic, large diameter Scleral RGP contact lenses (scleral lenses) may be used as a problem solver. Unlike the smaller corneal lenses which bear on the cornea, the scleral lenses completely bridge over the cornea and bear on the sclera.

The aim of this research is to investigate the performance of scleral lenses in KC participants who habitually wear corneal lenses.

The research question: is there a measurable difference in the visual performance and visual quality of life in participants with Irregular cornea disorders like keratoconus and other related conditions, who habitually wear corneal lenses in comparison with scleral lenses.

Read the detailed description

The cornea is the transparent, fixed focus lens at the front of the eye. The cornea's curvature should be regular for good vision. The most common causes of irregular cornea (IC) in hospital contact lens practice are Keratoconus (KC) and related cornea thinning disorders. These conditions cause mild to marked impairment of vision due to High Order optical Aberrations (HOA), which degrade the retinal image quality and cannot be effectively corrected by spectacles and soft contact lenses. The gold standard in the management of KC are Corneal Rigid Gas Permeable contact lenses (corneal lenses), which correct approximately 90% of the corneal irregularity.

The corneal lenses fit differently in patients with a normal cornea compared to KC where they bear on the cornea. This fitting characteristic and the vulnerability of the cornea in KC are implicated in corneal scarring and disease progression as well as a significantly reduced vision related quality of life (QoL) in KC compared with corneal lens wearers who have no KC.

In cases where corneal lenses are not well tolerated, cause corneal insult, reduced visual performance or poor physical fitting characteristic, the large diameter Scleral RGP contact lenses (scleral lenses) may be used as a problem solver. Unlike the smaller corneal lenses which bear on the cornea, the scleral lenses completely bridge over the cornea and bear on the sclera.

The aim of this research is to investigate the performance of scleral lenses in participants who habitually wear corneal lenses.

Methodology The proposed quantitative experimental methodology is a randomised controlled trial (RCT) with cross over. The experimental intervention is a scleral RGP contact lens fitted from a fitting set and manufactured to exact specifications to optimise its physical fitting characteristics and optical performance. The control intervention is conventional design Corneal Rigid Gas Permeable contact lenses (corneal lenses). These lenses are considered the gold standard in the management of the visual disability caused by keratoconus and other IC disorders (Robertson, Cavanagh 2011).

Main inclusion criteria; patients aged 18-69 with irregular cornea disorder like keratoconus who wear corneal lenses.

Exclusion criteria: Patients who are satisfied and have good vision and comfort with soft contact lenses or spectacles.

Procedure After the consent procedure all subjects will undergo a National Eye Institute Visual Function Quality NEI-VFQ assessment and baseline Best Corrected Visual Acuity (BCVA) and Contrast Sensitivity Function (CSF) will be recorded.

Detailed fitting of an alternative type of corneal lenses and scleral lenses using a state of the art design of corneal and scleral RGP lens designs, which have been widely used in many clinics world-wide for some years. Appropriate clinical guidelines and best practice will be followed for the fitting and use of contact lenses. The lead applicant is a contact lens specialist who is highly experienced in fitting corneal and scleral RGP contact lenses.

Once the fitting has been completed the final lenses will be checked on eye at collection and will be checked after three weeks post collection of the best fitting lens and for the final results of visual performance and quality of life after 8-12 weeks of daily lens wear.

After this check up there will be a washout period of at least one month, during which the participants will wear their original corneal lenses before the wearing of the other intervention is started.

The crossover to the other lens will be implemented after the washout period. During this phase checkups will be performed in an identical manner to the first phase.

Lens designs and fitting The participants will initially be fitted with corneal lenses and scleral lenses to achieve an optimal fit. Horizontal and vertical displacement as well as angular scleral lens rotation would be measured to establish best lens parameters. The corneal lenses will be the Rose K™ design which is widely used all over the world and manufactured by Menicon David Thomas contact lens laboratory. The scleral lenses will be the Zenlens™, which is amenable to a wide variety of customised adjustments for fit optimisation, manufactured by UCO Lavec BV laboratory in the Netherlands.

Randomisation The research coordinator, colleague optometrist Anthony Stanton will randomise and register the participants to treatment and control groups. The participants and the chief investigator will be masked to the type of lens supplied.

Outcome measures Visual quality Two key measures of visual function, monocular best-corrected visual acuity (BCVA) and contrast sensitivity function (CSF) will be assessed at the beginning and the end of the lens wearing period and will constitute the outcome measures of this RCT. Both BCVA and CSF testing will use a commercially available instrument the CSV 1000E, which standardises test conditions and has been used in several research studies.

Quality of life The National Eye Institute-Visual Function Questionnaire (NEI-VFQ) (Mangione 2000) is a vision-related quality of life instrument designed to assess patients' perception of visual function and quality of life. This instrument, which has been used by other researchers investigating keratoconus (Kymes et al., 2004, 2008), will be applied as a baseline in the beginning of the study and at the completion of the period of use of each intervention.

Statistical and Data analysis A sample size calculation has been carried out that is based, conservatively, on a parallel trial design using data from previous research (Marsack, Parker et al. 2007, Nejabat, Khalili et al. 2012, Davis, Schechtman et al. 2006). The sample size calculation using the (Armitage and Berry, 1987) formula gives a required sample size of 15 participants in each group. The plan is therefore to continue the study until at least 30 have completed the study, 15 starting with scleral lenses and 15 with corneal lenses.

Preliminary checks will be carried out to ensure that there are no carry-over effects from the first to the second treatment periods, as recommended in the literature (Haynes et al., 2006; Wellek \& Blettner, 2012).

We think it unlikely that there will be cross-over effects because the washout period should prevent this. However, in the unlikely event that there are significant washout effects or if a large proportion of participants drop out before the second treatment period then the study will be treated as a non-crossover RCT and the data from the first period will be analysed in the usual way as recommended by Haynes et al. (2006). Our conservative sample size calculation allows for this possibility.

If there is a satisfactory outcome to the preliminary checks then the study will be analysed as a cross-over RCT (Haynes et al., 2006; Wellek \& Blettner, 2012).

Plan and timescale The length of participation in the study for each subject is anticipated not to exceed 5-7months during which time they are likely to be required to attend on 4-6 occasions. Study total length is anticipated to be from early 2015 to late 2016. The RCT will be conducted at the Central Middlesex Hospital (CMH) Ophthalmology Department where the lead researcher is a senior contact lens specialist optometrist.

Being tested
Scleral rigid gas permeable contact lenses (SRGPcl) (Zenlens™), Corneal Rigid gas Permeable contact lenses (CRGPcl) (Rose K2)
Keywords
Corneal rigid gas permeable contact lenses, Scleral rigid gas permeable contact lenses, Custom Scleral contact lenses, Keratoconus, Irregular cornea, Pellucid marginal degeneration, Post keratoplasty irregular cornea, Post refractive surgery irregular cornea, Traumatic irregular cornea
Medical subject headings
Keratoconus, Corneal Injuries

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Scleral rigid gas permeable contact lenses (SRGPcl) (Zenlens™)Device

    Also called Scleral lenses, Zenlens, Custom Scleral Contact Lenses, RGP Scleral Lenses

    Custom manufactured scleral rigid gas permeable contact lenses. These lenses are designed to fit the eye with high level of precision. The aim is to bridge the cornea and fit in alignment with the sclera, thus avoiding any detrimental effects associated with the corneal rigid gas permeable lenses.

  • Corneal Rigid gas Permeable contact lenses (CRGPcl) (Rose K2)Device

    Also called Rose K2 corneal gas permeable contact lenses

    The Rose K2 lens is a widely used corneal gas permeable lens designed for keratoconus and other irregular cornea disorders

Study groups in NCT02444923
Study groupRoleWhat they receive
Scleral rigid gas permeable contact lensesExperimentalThe experimental intervention is the Scleral Rigid Gas Permeable contact lens (SRGPcl), Zenlens™. These lenses are designed to bridge the cornea and fit in alignment with the sclera, thus avoiding any detrimental effects associated with corneal contact.
Receives: Device: Scleral rigid gas permeable contact lenses (SRGPcl) (Zenlens™); Device: Corneal Rigid gas Permeable contact lenses (CRGPcl) (Rose K2)
Corneal rigid gas permeable contact lensesPlacebo comparatorThe control intervention is the RoseK2™ Corneal Rigid Gas Permeable contact lens (CRGPcl). Corneal lenses are considered the gold standard in the management of the visual disability due to keratoconus and other related irregular cornea disorders.
Receives: Device: Scleral rigid gas permeable contact lenses (SRGPcl) (Zenlens™); Device: Corneal Rigid gas Permeable contact lenses (CRGPcl) (Rose K2)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Monocular Best Corrected Visual Acuity (BCVA)

    High contrast BCVA will be measured by the specially constructed crowded, Logarithmic Minimum Angle of Resolution (LogMAR), Early Treatment Diabetic Retinopathy Survey (ETDRS) letter charts. An average score of 3 different, randomly presented charts will be taken as the final acuity score. It will be performed utilising the CSV1000E, under the established recommended standardised testing conditions utilised in a multitude of research protocols.

    Measured: Baseline and after a minimum of 6 weeks of wear of each contact lens type, report at study completion

Secondary outcomes (4)
  1. Contrast Sensitivity Function

    The Contrast Sensitivity Function (CSF) will be assessed at each of the four spatial frequencies 3, 6, 12 and 18 Cycles Per Degree (CPD) averaging the results from 2 different charts with sinusoidal grating patterns. This will be performed utilising the CSV1000E, under the established recommended standardised testing conditions utilised in a multitude of research protocols.

    Measured: Measure at recruitment (Baseline), subsequent measurement after 6 weeks of wear, of lens 1 and 6 weeks of wear of lens 2. Study completion after 6-12 months.

  2. The National Eye Institute-Visual Function Questionnaire (NEI-VFQ)

    The National Eye Institute-Visual Function Questionnaire (NEI-VFQ) (Mangione 2000) is a vision-related quality of life instrument designed to assess patients' perception of visual function and quality of life. The measurements include general health, general vision, ocular pain, near and distance activities, driving, colour vision, and peripheral vision. There are four components of psychological well being, these are; social function, mental health, role difficulties, and dependency function. It has been used to characterize the quality of life for patients with uveitis, diabetic retinopathy, glaucoma, and age-related macular degeneration (Mangione, Lee et al. 2001)

    Measured: Measure at recruitment (Baseline), subsequent measurement after 6 weeks of wear, of lens 1 and 6 weeks of wear of lens 2. Study completion after 6-12 months.

  3. The Levit Subjective Comfort and Vision Scales

    The Levit Subjective Comfort Scale (LSCS) and The Levit Subjective Vision Scale (LSVS) are Likert like scales which grade the participants' perception of their comfort and vision in contact lenses, on a scale from 1( worse) to 10 (best).

    Measured: Measure at recruitment (Baseline), subsequent measurement after 6 weeks of wear, of lens 1 and 6 weeks of wear of lens 2. Study completion after 6-12 months.

  4. The final lens choice

    Each participant chose one of the two experimental lenses they wished to keep for future habitual use

    Measured: At study completion after 6-12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 May 2015 (estimated)
  2. Study start25 Oct 2015
  3. Primary completion29 Jan 2019
  4. Study completion29 Jan 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Model description
Randomised control trial with a 2x2 crossover
Masking
Single blind
Who is masked
Investigator
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02444923
Sponsor's protocol ID
Levita
Status last verified
Aug 2019
First submitted
21 Apr 2015
Last updated
19 Aug 2019
Results posted
No
Data monitoring committee
Yes
Individual data sharing
No

Publications

  • Visser ES, Van der Linden BJ, Otten HM, Van der Lelij A, Visser R. Medical applications and outcomes of bitangential scleral lenses. Optom Vis Sci. 2013 Oct;90(10):1078-85. doi: 10.1097/OPX.0000000000000018.

    PubMed 23974663

Questions about this trial

What is this clinical trial studying?

A study testing Scleral rigid gas permeable contact lenses (SRGPcl) (Zenlens™) and Corneal Rigid gas Permeable contact lenses (CRGPcl) (Rose K2) in people with Irregular; Contour of Cornea and Keratoconus, run by London South Bank University at 1 site in United Kingdom.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Aug 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Monocular Best Corrected Visual Acuity (BCVA) (time frame: Baseline and after a minimum of 6 weeks of wear of each contact lens type, report at study completion). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02444923, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.