Quality of LifeNCT02866617
Randomized Controlled Clinical Trial Of Oral Health-Related Quality Of Life In Patients Wearing Vacuum Formed Thermoplastic Retainers Constructed On Conventional Stone Models And On 3D Reconstructed Orthodontic Study Model
A study testing Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model in people with Quality of Life, run by University of Malaya at 1 site in Malaysia.
Trial summary
In dentistry, 3D printing technology is gaining interest. One of the potential application is to construct appliances on 3D reconstructed study models. The purpose of this study is to compare vacuum formed thermoplastic orthodontic retainers (VFR) constructed on conventional orthodontic study models and reconstructed… Read more about this study
- Who is it for?
- Any ageHealthy volunteers can take part
- Conditions the study is for
- Quality of Life
- What is being tested?
- Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 30 participants
- Where
- 1 siteMalaysia
- Study dates
- Oct 2015to 30 Mar 2017
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- Healthy volunteers accepted
- Child, Adult, Older adult
- Inclusion criteria
- fixed appliance treatment following both arches;
- indicated for vacuum formed thermoplastic retainers as retention phase in treatment plan;
- Exclusion criteria:
- single-arch or sectional fixed appliance treatment,
- hypodontia requiring tooth replacement on the retainer as a temporary measure,
- undergone rapid maxillary expansion,
- indicated for double retention regime (bonded retainers),
- early debonding patients.
- patients intending to relocate within the study period
- patient with learning difficulties and can't read written instructions/questionnaire in English or Malay
- patient with cleft lip or palate
- has undergone surgical treatment
Trial locations and contacts
1 site in 1 country.
Malaysia1 site
Faculty of Dentistry, University of Malaya
Kuala Lumpur, 50603
About this study
In dentistry, 3D printing technology is gaining interest. One of the potential application is to construct appliances on 3D reconstructed study models.
The purpose of this study is to compare vacuum formed thermoplastic orthodontic retainers (VFR) constructed on conventional orthodontic study models and reconstructed 3D study models by assessing the oral health-related quality of life (OHRQoL) instrument, Little's Irregularity Index (LII) and compliance.
Read the detailed description
Aim:
To compare the impact of 2 types of vacuum formed thermoplastic retainers on patients.
Objectives:
- To compare oral health-related quality of life in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
- To compare compliance between vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
- To compare stability in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
Research Methadology
Ethical Consideration:
Application for ethical approval from Medical Ethics Committee, Faculty of Dentistry, University of Malaya.
Study population
This randomized controlled clinical trial will include existing patients who visited the Faculty of Dentistry, University of Malaya, for fixed orthodontic treatment and are due to have their fixed appliances removed.
5.2 Sample Size Estimation
Sample size estimation is based on previous study done by Jäderberg et al (2012) and calculated using PS Software (Power and Sample Size Calculation).
A sample size calculation was performed based on an alpha significance level of 0.05 and a beta of 0.1 to achieve 90 per cent power to detect a clinically meaningful difference of 1.0 mm [standard deviation (SD) 1.0] between the groups. The sample size calculation revealed that 22 pairs of sample were sufficient. This number of sample size will also achieve a moderate Pearson Product Moment correlation between the two groups. However, to compensate for possible dropouts, 30 pairs were enrolled in this clinical trials.
5.4 Materials and methods
- Enrollment \& Randomization Potential subjects will be recruited from the patients receiving orthodontic treatment at the Faculty of Dentistry, University of Malaya. Patients were screened based on when they were scheduled for debonding and the inclusion and exclusion criteria listed above. An online random number generator was used to create a randomization list of study numbers matched to either Group A or Group B. The day of debonding potential subjects were given consent and officially enrolled in the study.
- Study Groups As the flow chart below illustrates, two study groups existed for this randomized cross-over observational study. Each study group received 3 sets of vacuum formed thermoplastic retainers. Group A will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on stone study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on 3D reconstructed study model for another 3 months. Group B will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on 3D reconstructed study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on stone study model for another 3 months.
- Study Visit #1- Debonding Appointment All subjects were debonded by resident doctor, all residual composite removed, and teeth appropriately polished. Final photos were taken per University Clinic protocol. After debond, maxillary and mandibular alginate impressions (Hydrogum 5, Zhermack, Italy) will be obtained from each sample; two for working model and one for study model). One set of impression will be sent to University's Orthodontic Laboratory for construction of vacuum formed thermoplastic retainer by the laboratory technician for 1st appliance (to be issued on the same day of debond). The vacuum formed thermoplastic retainerss were made in the lab using thermoplastic material and clinic's Biostar machine available at the lab using the standard instructions provided by the manufacturer. vacuum formed thermoplastic retainerss were cooled and trimmed accordingly. Clinically vacuum formed thermoplastic retainerss were evaluated by resident doctor intra orally and were adjusted for patient comfort. All subjects were instructed to wear their retainers full time, only remove to eat, brush, and clean. For the remaining two sets of impression, the impression is poured in dental stone within 24hours.
- Acquisition of stone study model. Impressions obtained will be disinfect before casting. The white stone (Elite Ortho, Zhermack, Italy) is mixed and tapped into the impression a little at a time to ensure no air is trapped within the stone mix and some stone is used to form the base. Once the stone has set sufficiently, the impression is inverted on the base. When casting the lower impression, stone in the lingual section is removed before setting fully to ensure that the impression can easily be removed from the model.
Once the base has fully set the impression will be carefully removed from the stone and gradually lifted from the model using a plaster knife. The resulting stone model is then trimmed using a model trimmer. The base of the model parallel to the occlusal plane is trimmed to ensure even adaption of the thermoforming material. The back edge of the model should be trimmed so that it is at 90° to the sagittal plane. The labial and buccal sides of the model should be trimmed round so that the final model is a 'D' shape.
5 : Acquisition of digital model. Conventional study model will be scanned using structured light scanner (Maestro 3D, Age Solutions, Inc, Italy) via EasyDentalScan software (Age Solutions, Inc) to produce 3D digital model. The scanned data for both upper and lower conventional study models will be saved and exported as binary stereolithographic (.stl) files.
6 : Acquisition of reconstructed model. A Fused Deposition Modelling (FDM) machine (UP! 2 Plus 3D Printer) containing acrylonitrile butadiene styrene (ABS) plastic will be used to construct replica (RP) model from digital file according to manufacturing instructions. This process will be done by CBMTI SDN BHD ( a subsidiary of UM CAPITAL BERHAD), Institute of Postgraduate Studies, University of Malaya.
The prototyping process begins with unwinding the feedstock filament from a reel and feeding it through the liquefier located inside the system working envelop, as shown in figure below, where it gets gradually heated by temperature gradient provided by a number of coils wrapped helically about the axis of the liquefier .
The heated liquefier melts the plastic filament and deposits the melt through a nozzle attached at the exit controlling the diameter of final extrudate. Two step motors at the entrance of liquefier make sure a continuous supply of material during the model build-up. The nozzle and liquefier assembly is mounted onto a mechanical stage numerically controlled in X-Y plane. Upon receipt of precise tool paths prepared by the Insight software, the nozzle moves over the foam substrate depositing a thin bead of thermoplastic model material along with any necessary support structure. Deposition of fine extruded filaments onto the substrate produces a layer corresponding to a slice of the CAD model of the object. Once a layer is built the substrate moves down in z direction in order to prepare the stage for the deposition of next layer. The deposited filaments cool down immediately below the glass transition temperature of the polymer and get hardened. The entire build system is contained within a temperature- controlled environment with temperatures just below the glass-transition temperature of the polymer to provide an efficient intra-layer bonding.
7 : Acquisition of vacuum formed thermoplastic retainer
Each VFR was constructed from an Erkodur blank (Erkodent, Erich Kopp, GmbH, Pfalzgrafenweiler, Germany) 1.5 mm in thickness using the standard instructions provided by the laboratory's Biostar machine.
Retainer Designs:
vacuum formed thermoplastic retainerss Designs- Extraction and Non-extraction Cases
- Upper- Trimmed for 1-2mm of facial gingival coverage, palatal coverage, and 2nd Molar occlusal coverage
- Lower- Trimmed for 1-2mm of facial and lingual gingival coverage, 2nd Molar occlusal coverage. 8 : T2 and T3 visit: Issuing the vacuum formed thermoplastic retainer. The 2nd retainers will be fitted within 1 week after debond (T1) and the 3rd retainers is fitted 3 months (T2) after debond. The duration of retainer wear was standardized based on the standard protocol for retainer wear in the practice. The patients were instructed to wear the vacuum formed thermoplastic retainers 24 hours a day for the first week and remove them only for eating and brushing their teeth. After the first week, wear time was reduced to 10 hours a day (Thickett and Power, 2009). All patients will be provided with standardized oral and written instructions on how to use the retainers by one dentist.
The subjects were reviewed by a member of the research team at 2 intervals, 3 months (T2) and 6 months (T3) after debond. At the 3 month (T2) review appointment, the subjects will be given the Questionnaire Q2 to be filled up. Later, the 3rd retainer will be given to the subjects and again to be reviewed after 3 months (T3) of 3rd retainer issued ( 6 months after debond) and questionnaire Q3 will be administered.
- Conditions
- Quality of Life
- Being tested
- Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model
- Keywords
- Quality of Life, Vacuum formed thermoplastic retainer, Orthodontic study model, 3D reconstructed study model
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study ModelDevice
| Study group | Role | What they receive |
|---|---|---|
| Conventional | Experimental | T1-T2 : VFR constructed on conventional study model T2-T3 : VFR constructed on 3D reconstructed study model Receives: Device: Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model |
| 3D | Experimental | T1-T2 : VFR constructed on 3D reconstructed study model T2-T3 :VFR constructed on conventional study model Receives: Device: Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model |
What is being measured
The primary outcome is the main question the study is designed to answer.
Oral Health-Related Quality Of Life
Measured: 6 month
Secondary outcomes (1)
Little's Irregularity Index
Measured: 6 month
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Aug 2016 (estimated)
- Study startOct 2015
- Primary completion30 Jan 2017
- Study completion30 Mar 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Quality of LifeStudies of the same condition, open and under way.
- More trials run by University of MalayaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Double blind
- Who is masked
- Participant, Investigator
- Enrolment
- 30 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Malaya
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Wan Nurazreena Wan Hassan, BDS, Principal investigator, University of Malaya
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02866617
- Sponsor's protocol ID
- PPPC/C1-2015/DGD/12
- Status last verified
- Apr 2018
- First submitted
- 8 May 2016
- Last updated
- 9 Apr 2018
- Results posted
- No
Publications
Mohd Tahir N, Wan Hassan WN, Saub R. Comparing retainers constructed on conventional stone models and on 3D printed models: a randomized crossover clinical study. Eur J Orthod. 2019 Aug 8;41(4):370-380. doi: 10.1093/ejo/cjy063.
PubMed 30321319
Study at a glance
From the registry record, last updated by the sponsor on 9 Apr 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Randomized Controlled Clinical Trial Of Oral Health-Related Quality Of Life In Patients Wearing Vacuum Formed Thermoplastic Retainers Constructed On Conventional Stone Models And On 3D Reconstructed Orthodontic Study Model
- ClinicalTrials.gov ID
- NCT02866617
- Acronym / sponsor ID
- PPPC/C1-2015/DGD/12
- Conditions
- Quality of Life
- Keywords
- Quality of Life, Vacuum formed thermoplastic retainer, Orthodontic study model, 3D reconstructed study model
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 30 participants (actual)
- Lead sponsor
- University of MalayaUniversity, hospital or other
- Study start
- Oct 2015 (actual)
- Primary completion
- 30 Jan 2017 (actual)
- Study completion
- 30 Mar 2017 (actual)
- First posted
- 15 Aug 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
In dentistry, 3D printing technology is gaining interest. One of the potential application is to construct appliances on 3D reconstructed study models.
The purpose of this study is to compare vacuum formed thermoplastic orthodontic retainers (VFR) constructed on conventional orthodontic study models and reconstructed 3D study models by assessing the oral health-related quality of life (OHRQoL) instrument, Little's Irregularity Index (LII) and compliance.
Detailed description
Aim:
To compare the impact of 2 types of vacuum formed thermoplastic retainers on patients.
Objectives:
- To compare oral health-related quality of life in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
- To compare compliance between vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
- To compare stability in patients wearing vacuum formed thermoplastic retainers constructed on a conventional orthodontic study model and reconstructed 3D study model up to 6 months.
Research Methadology
Ethical Consideration:
Application for ethical approval from Medical Ethics Committee, Faculty of Dentistry, University of Malaya.
Study population
This randomized controlled clinical trial will include existing patients who visited the Faculty of Dentistry, University of Malaya, for fixed orthodontic treatment and are due to have their fixed appliances removed.
5.2 Sample Size Estimation
Sample size estimation is based on previous study done by Jäderberg et al (2012) and calculated using PS Software (Power and Sample Size Calculation).
A sample size calculation was performed based on an alpha significance level of 0.05 and a beta of 0.1 to achieve 90 per cent power to detect a clinically meaningful difference of 1.0 mm [standard deviation (SD) 1.0] between the groups. The sample size calculation revealed that 22 pairs of sample were sufficient. This number of sample size will also achieve a moderate Pearson Product Moment correlation between the two groups. However, to compensate for possible dropouts, 30 pairs were enrolled in this clinical trials.
5.4 Materials and methods
- Enrollment \& Randomization Potential subjects will be recruited from the patients receiving orthodontic treatment at the Faculty of Dentistry, University of Malaya. Patients were screened based on when they were scheduled for debonding and the inclusion and exclusion criteria listed above. An online random number generator was used to create a randomization list of study numbers matched to either Group A or Group B. The day of debonding potential subjects were given consent and officially enrolled in the study.
- Study Groups As the flow chart below illustrates, two study groups existed for this randomized cross-over observational study. Each study group received 3 sets of vacuum formed thermoplastic retainers. Group A will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on stone study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on 3D reconstructed study model for another 3 months. Group B will wear vacuum formed thermoplastic retainers constructed by laboratory technician according to their standard protocol for 1 week from the day of debond, then vacuum formed thermoplastic retainers constructed on 3D reconstructed study model by one dentist after 1 week of debond for 3 months and later vacuum formed thermoplastic retainers constructed on stone study model for another 3 months.
- Study Visit #1- Debonding Appointment All subjects were debonded by resident doctor, all residual composite removed, and teeth appropriately polished. Final photos were taken per University Clinic protocol. After debond, maxillary and mandibular alginate impressions (Hydrogum 5, Zhermack, Italy) will be obtained from each sample; two for working model and one for study model). One set of impression will be sent to University's Orthodontic Laboratory for construction of vacuum formed thermoplastic retainer by the laboratory technician for 1st appliance (to be issued on the same day of debond). The vacuum formed thermoplastic retainerss were made in the lab using thermoplastic material and clinic's Biostar machine available at the lab using the standard instructions provided by the manufacturer. vacuum formed thermoplastic retainerss were cooled and trimmed accordingly. Clinically vacuum formed thermoplastic retainerss were evaluated by resident doctor intra orally and were adjusted for patient comfort. All subjects were instructed to wear their retainers full time, only remove to eat, brush, and clean. For the remaining two sets of impression, the impression is poured in dental stone within 24hours.
- Acquisition of stone study model. Impressions obtained will be disinfect before casting. The white stone (Elite Ortho, Zhermack, Italy) is mixed and tapped into the impression a little at a time to ensure no air is trapped within the stone mix and some stone is used to form the base. Once the stone has set sufficiently, the impression is inverted on the base. When casting the lower impression, stone in the lingual section is removed before setting fully to ensure that the impression can easily be removed from the model.
Once the base has fully set the impression will be carefully removed from the stone and gradually lifted from the model using a plaster knife. The resulting stone model is then trimmed using a model trimmer. The base of the model parallel to the occlusal plane is trimmed to ensure even adaption of the thermoforming material. The back edge of the model should be trimmed so that it is at 90° to the sagittal plane. The labial and buccal sides of the model should be trimmed round so that the final model is a 'D' shape.
5 : Acquisition of digital model. Conventional study model will be scanned using structured light scanner (Maestro 3D, Age Solutions, Inc, Italy) via EasyDentalScan software (Age Solutions, Inc) to produce 3D digital model. The scanned data for both upper and lower conventional study models will be saved and exported as binary stereolithographic (.stl) files.
6 : Acquisition of reconstructed model. A Fused Deposition Modelling (FDM) machine (UP! 2 Plus 3D Printer) containing acrylonitrile butadiene styrene (ABS) plastic will be used to construct replica (RP) model from digital file according to manufacturing instructions. This process will be done by CBMTI SDN BHD ( a subsidiary of UM CAPITAL BERHAD), Institute of Postgraduate Studies, University of Malaya.
The prototyping process begins with unwinding the feedstock filament from a reel and feeding it through the liquefier located inside the system working envelop, as shown in figure below, where it gets gradually heated by temperature gradient provided by a number of coils wrapped helically about the axis of the liquefier .
The heated liquefier melts the plastic filament and deposits the melt through a nozzle attached at the exit controlling the diameter of final extrudate. Two step motors at the entrance of liquefier make sure a continuous supply of material during the model build-up. The nozzle and liquefier assembly is mounted onto a mechanical stage numerically controlled in X-Y plane. Upon receipt of precise tool paths prepared by the Insight software, the nozzle moves over the foam substrate depositing a thin bead of thermoplastic model material along with any necessary support structure. Deposition of fine extruded filaments onto the substrate produces a layer corresponding to a slice of the CAD model of the object. Once a layer is built the substrate moves down in z direction in order to prepare the stage for the deposition of next layer. The deposited filaments cool down immediately below the glass transition temperature of the polymer and get hardened. The entire build system is contained within a temperature- controlled environment with temperatures just below the glass-transition temperature of the polymer to provide an efficient intra-layer bonding.
7 : Acquisition of vacuum formed thermoplastic retainer
Each VFR was constructed from an Erkodur blank (Erkodent, Erich Kopp, GmbH, Pfalzgrafenweiler, Germany) 1.5 mm in thickness using the standard instructions provided by the laboratory's Biostar machine.
Retainer Designs:
vacuum formed thermoplastic retainerss Designs- Extraction and Non-extraction Cases
- Upper- Trimmed for 1-2mm of facial gingival coverage, palatal coverage, and 2nd Molar occlusal coverage
- Lower- Trimmed for 1-2mm of facial and lingual gingival coverage, 2nd Molar occlusal coverage. 8 : T2 and T3 visit: Issuing the vacuum formed thermoplastic retainer. The 2nd retainers will be fitted within 1 week after debond (T1) and the 3rd retainers is fitted 3 months (T2) after debond. The duration of retainer wear was standardized based on the standard protocol for retainer wear in the practice. The patients were instructed to wear the vacuum formed thermoplastic retainers 24 hours a day for the first week and remove them only for eating and brushing their teeth. After the first week, wear time was reduced to 10 hours a day (Thickett and Power, 2009). All patients will be provided with standardized oral and written instructions on how to use the retainers by one dentist.
The subjects were reviewed by a member of the research team at 2 intervals, 3 months (T2) and 6 months (T3) after debond. At the 3 month (T2) review appointment, the subjects will be given the Questionnaire Q2 to be filled up. Later, the 3rd retainer will be given to the subjects and again to be reviewed after 3 months (T3) of 3rd retainer issued ( 6 months after debond) and questionnaire Q3 will be administered.
Study design
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Double blind (participant, investigator)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Conventional | Experimental | Device: Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study ModelT1-T2 : VFR constructed on conventional study model T2-T3 : VFR constructed on 3D reconstructed study model |
| 3D | Experimental | Device: Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study ModelT1-T2 : VFR constructed on 3D reconstructed study model T2-T3 :VFR constructed on conventional study model |
Who may qualify
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Child, Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model | Device | 3D, Conventional |
Primary outcome
Oral Health-Related Quality Of Life
Time frame: 6 month
1 secondary outcome
Little's Irregularity Index
Time frame: 6 month
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Apr 2018.
- Derived from this study: PubMed 30321319Mohd Tahir N, Wan Hassan WN, Saub R. Comparing retainers constructed on conventional stone models and on 3D printed models: a randomized crossover clinical study. Eur J Orthod. 2019 Aug 8;41(4):370-380. doi: 10.1093/ejo/cjy063.
Related trials for Quality of Life
RecruitingObservational study
Endoscopic Sleeve Gastroplasty (ESG) Prospective Trial for Obesity (EGO-Trial)
Obesity
RecruitingPhase 4
The Effects of Ferric Derisomaltose in Patients With Acute Heart Failure and Iron Deficiency on Exercise Capacity and Quality of Life(COREVIVE-HFrEF)
Heart Failure With Reduced Ejection Fraction, Iron Deficiency
Recruiting
Study of a Support Program for Quality of Life in Chinese Cancer Patients and Survivors
Cancer, Survivorship
Not yet recruitingObservational study
Functional Impact of Psychological Symptoms in Patients With Superior Semicircular Canal Dehiscence Syndrome (SSCD): a National Cross-sectional Study
Superior Semicircular Canal Dehiscence
Not yet recruitingPhase 2
Alberta Cancer Exercise Dose in Colorectal Cancer
Cancer, Colorectal Cancer
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Wan Nurazreena Wan Hassan, BDS principal investigator
University of Malaya
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Vacuum Formed Thermoplastic Retainers Constructed On 3D Reconstructed Orthodontic Study Model in people with Quality of Life, run by University of Malaya at 1 site in Malaysia.
The full registered description is in the About this study section and the official record.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Apr 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Malaysia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Oral Health-Related Quality Of Life (time frame: 6 month). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02866617, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Apr 2018.