AzTrials
AzTrials

Cardiac CatheterizationPhase 2NCT03245255

Noninvasive Real-time Intracardiac Pressure Measurements Using Subharmonic Ultrasound

A Phase 2 study testing Sonazoid in people with Cardiac Catheterization and Blood Pressure, run by Thomas Jefferson University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study will use contrast echocardiography to assess the accuracy of a new non-invasive imaging method for subharmonic aided pressure estimation (SHAPE) compared to simultaneously acquired intra-cardiac pressures measured invasively during cardiac catheterization. Read more about this study

Who is it for?
Ages 21 years and older
What is being tested?
Sonazoid
Type of treatment
Injection or infusion
Could I receive a placebo?
No, everyone receives an active treatment
How many people
80 participants
Where
1 siteUnited States
Study dates
4 Dec 2017to 7 Jun 2023
Phase
Phase 2
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Be scheduled for cardiac catheterization procedure.
  • Be at least 18 years of age.
  • Be medically stable.
  • If a female of child-bearing potential, must have a negative pregnancy test.
  • Be conscious and able to comply with study procedures.
  • Have signed Informed Consent to participate in the study.

Who cannot join

  • Clinically unstable patients, e.g., those who are clinically in decompensated heart failure or having active chest pain or presenting for admission with an unstable anginal syndrome
  • Patients in whom introduction of a catheter into the left ventricle is contraindicated or would potentially be dangerous, e.g., patients with active ventricular arrhythmias or with significant aortic valve stenosis where crossing the aortic valve may be difficult and not clinically necessary
  • Females who are pregnant or nursing.
  • Patients not scheduled for cardiac catheterization procedure.
  • Patients who have received an investigational drug in the 30 days before, or will receive one within 72 h after, study drug administration.
  • Patients currently on chemotherapy or with other primary cancers requiring treatment.
Show all 12Show fewer
  • Patients who are medically unstable, patients who are seriously or terminally ill, and patients whose clinical course is unpredictable.
  • Patients with a history of anaphylactic allergy to eggs or egg products, manifested by one or more of the following symptoms: generalised urticaria, difficulty in breathing, swelling of the mouth and throat, hypotension, or shock. (Subjects with nonanaphylactic allergies to eggs or egg products may be enrolled in the study, but must be watched carefully for 1 h following the administration of SONAZOID).
  • Patients with congenital heart defects.
  • Patients with severe emphysema, pulmonary vasculitis, or a history of pulmonary emboli.
  • Patients with respiratory distress syndrome or a contraindication to pharmacological vasodilator stress agents.
  • Patients with thrombosis within the hepatic, portal, or mesenteric veins.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Thomas Jefferson University and Thomas Jefferson University Hospital

    Philadelphia, Pennsylvania, 19107

Other trials in United States

About this study

This study will use contrast echocardiography to assess the accuracy of a new non-invasive imaging method for subharmonic aided pressure estimation (SHAPE) compared to simultaneously acquired intra-cardiac pressures measured invasively during cardiac catheterization. This study is designed to verify that contrast echocardiography using the SHAPE method, already proven in a canine model and tested in a human pilot study can be used as a surrogate for cardiac catheterization with sufficient accuracy to allow clinical applicability in humans.

Being tested
Sonazoid
Keywords
pressure measurements, blood pressure, contrast echocardiography, ventricular pressures, catheterization
Medical subject headings
Heart Failure

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SonazoidDrug

    Whenever a patient undergoes cardiac catheterization, which routinely includes intracardiac pressure monitoring using a pressure catheter, as part of their standard clinical care and agrees to participate in the study, we will acquire research data. With Sonazoid infusion, SHAPE algorithm will be initiated to determine optimum acoustic pressure. Then, at the optimum acoustic pressure, SHAPE specific data will be acquired from the cardiac chambers and aorta synchronously with the pressures recorded by the catheter (as a part of the patient's standard of care). After acquiring the ultrasound imaging data, the remainder of the heart catheterization will be completed by the attending cardiologist according to the patients' standard of care.

Study groups in NCT03245255
Study groupRoleWhat they receive
Sonazoid for pressure measurementsExperimental48 µl of Sonazoid microbubbles (GE Healthcare, Oslo, Norway) will be co-infused at a rate of 0.024 µl/kg body weight/minute together with a 0.9% sodium chloride solution infused at a rate of at least 2 ml/min.
Receives: Drug: Sonazoid

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Agreement Between SHAPE and Pressure Catheter Measurements

    The Pearson correlation coefficient was computed between the simultaneously acquired subharmonic signal and pressure catheter data (i.e., waveforms) for each participant. The Pearson correlation coefficient was used for comparing waveforms given the underlying data and pressure values used for comparisons followed a normal distribution. Values reported will be the mean Pearson correlation coefficient values between the subharmonic waveforms and pressure catheter waveforms obtained.

    Measured: up to 1 day

  2. Error Between SHAPE and Pressure Catheter Measurements

    Based on the distribution of the differences in cardiac pressure values obtained using the SHAPE technique and the clinical pressure catheter, either a two-tailed paired t test (normal distribution) or Wilcoxon signed rank test (nonnormal distribution) was used to compare the SHAPE technique to the reference standard. Bonferroni corrections were used for multiple comparisons

    Measured: up to 1 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Aug 2017
  2. Study start4 Dec 2017
  3. Primary completion18 Sep 2020
  4. Study completion7 Jun 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 2
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
80 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03245255
Sponsor's protocol ID
R21HL130899
Other IDs
R21HL130899
Status last verified
May 2024
First submitted
4 Aug 2017
Last updated
29 May 2024
Data monitoring committee
No
FDA-regulated drug
Yes
FDA-regulated device
No
Individual data sharing
Yes: This project will generate pressure values in the aorta, and left and right ventricles using the proposed research method (i.e., SHAPE) and using the standard of care (i.e., catheter based pressure values). Additionally peripheral and central pressures will be generated. All of the pressure values will be made available. Further, all ultrasound data obtained for SHAPE measurements will be made available after anonymizing the data-set to remove any patient information

Publications

  • Dave JK, Halldorsdottir VG, Eisenbrey JR, Liu JB, McDonald ME, Dickie K, Leung C, Forsberg F. Noninvasive estimation of dynamic pressures in vitro and in vivo using the subharmonic response from microbubbles. IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Oct;58(10):2056-66. doi: 10.1109/TUFFC.2011.2056.

    PubMed 21989870
  • Dave JK, Halldorsdottir VG, Eisenbrey JR, Forsberg F. Processing of subharmonic signals from ultrasound contrast agents to determine ambient pressures. Ultrason Imaging. 2012 Apr;34(2):81-92. doi: 10.1177/016173461203400202.

    PubMed 22724314
  • Dave JK, Halldorsdottir VG, Eisenbrey JR, Merton DA, Liu JB, Machado P, Zhao H, Park S, Dianis S, Chalek CL, Thomenius KE, Brown DB, Forsberg F. On the implementation of an automated acoustic output optimization algorithm for subharmonic aided pressure estimation. Ultrasonics. 2013 Apr;53(4):880-8. doi: 10.1016/j.ultras.2012.12.010. Epub 2013 Jan 2.

    PubMed 23347593
  • Dave JK, Halldorsdottir VG, Eisenbrey JR, Raichlen JS, Liu JB, McDonald ME, Dickie K, Wang S, Leung C, Forsberg F. Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures. Am J Physiol Heart Circ Physiol. 2012 Jul;303(1):H126-32. doi: 10.1152/ajpheart.00560.2011. Epub 2012 May 4.

    PubMed 22561300
  • Dave JK, Halldorsdottir VG, Eisenbrey JR, Raichlen JS, Liu JB, McDonald ME, Dickie K, Wang S, Leung C, Forsberg F. Noninvasive LV pressure estimation using subharmonic emissions from microbubbles. JACC Cardiovasc Imaging. 2012 Jan;5(1):87-92. doi: 10.1016/j.jcmg.2011.08.017.

    PubMed 22239898
  • Eisenbrey JR, Dave JK, Halldorsdottir VG, Merton DA, Miller C, Gonzalez JM, Machado P, Park S, Dianis S, Chalek CL, Kim CE, Baliff JP, Thomenius KE, Brown DB, Navarro V, Forsberg F. Chronic liver disease: noninvasive subharmonic aided pressure estimation of hepatic venous pressure gradient. Radiology. 2013 Aug;268(2):581-8. doi: 10.1148/radiol.13121769. Epub 2013 Mar 22.

    PubMed 23525208
  • Forsberg F, Liu JB, Shi WT, Furuse J, Shimizu M, Goldberg BB. In vivo pressure estimation using subharmonic contrast microbubble signals: proof of concept. IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Apr;52(4):581-3. doi: 10.1109/tuffc.2005.1428040.

    PubMed 16060506
  • Halldorsdottir VG, Dave JK, Leodore LM, Eisenbrey JR, Park S, Hall AL, Thomenius K, Forsberg F. Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions. Ultrason Imaging. 2011 Jul;33(3):153-64. doi: 10.1177/016173461103300301.

    PubMed 21842580
  • Shi WT, Forsberg F, Raichlen JS, Needleman L, Goldberg BB. Pressure dependence of subharmonic signals from contrast microbubbles. Ultrasound Med Biol. 1999 Feb;25(2):275-83. doi: 10.1016/s0301-5629(98)00163-x.

    PubMed 10320317
  • Halldorsdottir VG, Dave JK, Eisenbrey JR, Machado P, Zhao H, Liu JB, Merton DA, Forsberg F. Subharmonic aided pressure estimation for monitoring interstitial fluid pressure in tumours--in vitro and in vivo proof of concept. Ultrasonics. 2014 Sep;54(7):1938-44. doi: 10.1016/j.ultras.2014.04.022. Epub 2014 May 6.

    PubMed 24856899
  • Esposito C, Machado P, McDonald ME, Savage MP, Fischman D, Mehrotra P, Cohen IS, Ruggiero N 2nd, Walinsky P, Vishnevsky A, Dickie K, Davis M, Forsberg F, Dave JK. Evaluation of Intracardiac Pressures Using Subharmonic-aided Pressure Estimation with Sonazoid Microbubbles. Radiol Cardiothorac Imaging. 2024 Feb;6(1):e230153. doi: 10.1148/ryct.230153.

    PubMed 38358329
  • Esposito C, Machado P, Cohen IS, Mehrotra P, Savage M, Fischman D, Davis M, Ruggiero N, Walinsky P, McDonald ME, Dickie K, Forsberg F, Dave JK. Comparing Central Aortic Pressures Obtained Using a SphygmoCor Device to Pressures Obtained Using a Pressure Catheter. Am J Hypertens. 2022 May 10;35(5):397-406. doi: 10.1093/ajh/hpac010.

    PubMed 35079778

Questions about this trial

What is this clinical trial studying?

A Phase 2 study testing Sonazoid in people with Cardiac Catheterization and Blood Pressure, run by Thomas Jefferson University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 May 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 29 May 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Agreement Between SHAPE and Pressure Catheter Measurements (time frame: up to 1 day). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03245255, which also lists 12 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 May 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in