Tracheal StenosisEDITION2NCT03411928

Endotracheal Dilator to Improve Oxygenation

A study testing Tracheolator in people with Tracheal Stenosis and Airway Disease, run by University of Cape Town at 1 site in South Africa.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of the study is to prospectively assess the use of a modified tracheal balloon dilator in children (<13 years old) with subglottic or tracheal stenosis. The hypothesis is that the device will effectively dilate the stenotic segment, whilst maintaining oxygenation (if applicable). Read more about this study

Who is it for?
Ages Up to 13 years
What is being tested?
Tracheolator
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
12 participants
Where
1 siteSouth Africa
Study dates
1 Sep 2018to 30 Dec 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 13 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Refractory stenosis not amenable to balloon dilatation
  • Contraindication to balloon dilatation (long-segment stenosis)
  • Patient refusal

Who cannot join

  • Refractory stenosis not amenable to balloon dilatation
  • Contraindication to balloon dilatation (long-segment stenosis)
  • Patient refusal

Trial locations and contacts

1 site in 1 country.

Jessica McGuire, FCORL contact

+27722072991

jessica.mcguire@uct.ac.za

Ross Hofmeyr, FCA(SA) contact

+27845499259

ross.hofmeyr@uct.ac.za

South Africa1 site
  • Groote Schuur Hospital

    Cape Town, Western Cape, 7925

    Ross Hofmeyr, FCA(SA), +27214045003, ross.hofmeyr@uct.ac.za

    Reuben Smith, MBChB

Other trials in South Africa

About this study

Official title: Modified Endotracheal Balloon Dilator to Improve Oxygenation During Airway Procedures in Children With Tracheal Stenosis

The purpose of the study is to prospectively assess the use of a modified tracheal balloon dilator in children (<13 years old) with subglottic or tracheal stenosis. The hypothesis is that the device will effectively dilate the stenotic segment, whilst maintaining oxygenation (if applicable). The primary aim is to measure the stenosis prior to, and after dilatation; using diameter and the modified Myer-Cotton grading system. Secondary aims include assessment of stenosis at six-week follow-up and monitoring arterial oxygenation nadir (using peripheral plethysmography) during the procedure.

Read the detailed description

This study is a prospective, single arm, observational study of patients at Red Cross War Memorial Children's Hospital receiving treatment for laryngotracheal stenosis using a modified tracheal dilatation balloon. The tracheal balloon dilatation procedure is clinically well-established and is standard practice in the study institution. In this study, a modified, improved tracheal balloon will be used to treat patients. Data to be collected during the procedure include measurement of the stenotic segment prior to and after dilatation, using both the modified Myer-Cotton grading system and sizing the stenosis using endotracheal tubes diameter, documenting the site of the stenosis (distance from vocal cords), periprocedural oxygen saturation nadir (using plethysmography) and heart rate. All other procedures will be as per routine care. Each procedure will be monitored by a senior anaesthetist who is not a member of the research team. Their role will be to ensure the safety of the patient.

The tracheal balloon dilatation device consists of a catheter tube which has an inflation port at its proximal end and a balloon at its distal end. The balloon is provided in a narrow, folded condition to allow entering and traversing the stenotic portion of the airway. As with all tracheal dilatation balloons, when inflated with an inflator equipped with a pressure manometer, the device generates an outward radial force to dilate the stenotic portion of the airway. The balloon differs from previous devices used for dilatation of tracheal stenosis in that it is modified to have a large central channel when inflated, which allows gas flow through the balloon.

All materials in the device are medical grade and sourced from specialist medical suppliers. The balloons specifically have undergone biocompatibility testing according to ISO 10993-1 (Biological testing of medical devices) and passed all tests. Safety of the devices has been rigorously demonstrated through in vitro bench testing, and balloons have been shown to survive a minimum of 10 inflations to rated burst pressure without bursting. The devices are manufactured by a facility experienced in production of endovascular balloons, in an ISO 14644 Class 7 compliant clean-room in a manufacturing facility that has a certified ISO 13485 quality management system. The balloons are tested as part of an ongoing quality control process, to ensure that tight tolerances are maintained in terms of wall thickness, nominal diameter and rated burst pressure. Furthermore, every tracheal balloon device will have been pressure tested to 16 atm before being used, to ensure that no leaks are present.

The device has been assessed in three previous studies, in manikin, animal and adult human use settings. The studies proved that it is possible to adequately ventilate patients through the modified balloon dilation device. There was no incident of arterial desaturation below 90%. No serious adverse events were recorded.

The study will be conducted over a 12 week period, with an average of 1 patient per week undergoing the procedure at the study site. Recruitment is thus estimated at 12 patients (not procedures).

All research and procedures will take place at Red Cross War Memorial Children's Hospital. Patients will be treated in the operating theatres and will recover in the recovery room, followed by the ENT ward. Patients who have suspected airway narrowing and present to the Department of Otolaryngology will be approached by for potential involvement in the study. The process will be explained obtain written informed consent obtained. The patient will then be treated as per routine care and will be included in the study should inclusion and exclusion criteria be satisfied.

All patients will undergo a thorough routine preoperative assessment. Anaesthesia will be standardized in the absence of specific complication. Routine continuous operative monitoring will be used for all cases, including electrocardiogram, non-invasive automatic blood pressure and pulse oximetry.

A rigid laryngoscope will be inserted into the patient's airway and placed in suspension. The level and severity of the stenosis will be evaluated and the tracheal balloon dilator will be placed at the level of the stenosis under direct vision, using an endoscope. The patient will be kept breathing spontaneously if they do not have a tracheostomy tube. Ventilation will be maintained using a tracheostomy tube, if available.

The balloon will be inflated with water using an inflation device, under direct vision. The pressure in the balloon will be adjusted to 6-8 atmospheres and maintained for at least 1 minute, unless arterial desaturation occurs (SpO2 < 90%) Dilatation will be performed 3 times.

Heart rate and peripheral arterial oxygen saturation will be continuously monitored throughout the procedure. These values will be recorded automatically at one-minute intervals from induction until completion of the dilatation phase, and then at 2.5-minute intervals until recovery from anaesthesia. The stenosis will be graded according to the Myer-Cotton staging system for subglottic stenosis, as well as, the internal diameter of the stenosis being measured (using an endotracheal tube) before and after dilatation.

Adverse events will be recorded in data collection forms. Adverse events will include:

  • Arterial desaturation below 90%
  • Loss of airway patency
  • Inability to ventilate
  • Patient coughing or movement
  • Haemorrhage
  • Inability to pass the bronchoscope
  • Balloon failure
  • False passage
  • Tracheal injury
  • Oesophageal injury
  • Gastric haemorrhage
  • Pneumothorax
  • Pneumomediastinum
  • Subcutaneous emphysema
  • Vocal cord injury
  • Mediastinitis
  • Chest pain
  • Laryngospasm
  • Bronchospasm
  • Atelectasis
  • Pulmonary oedema
  • Hypoxia
  • Aspiration of water (in case of balloon failure)

Data analysis Data will be collected intraoperatively using a data collection form. This will be transferred to an electronic spreadsheet for analysis. As this is a single-arm study without control devices, no comparative statistics will be calculated. Where appropriate, data will be expressed as mean ± standard deviation.

Being tested
Tracheolator
Medical subject headings
Tracheal Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • TracheolatorDevice

    'Tracheolator' non-occlusive tracheal dilation balloon manufactured by Disa Life Sciences, Cape Town, South Africa.

Study groups in NCT03411928
Study groupRoleWhat they receive
TracheolatorExperimentalTracheal dilatation using the study device as per the protocol.
Receives: Device: Tracheolator

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in internal tracheal stenosis diameter

    Post-dilation change from pre-dilatation values, measured using Myer-Cotton grade and millimeter value

    Measured: Immediate

Secondary outcomes (2)
  1. Peripheral arterial oxygenation

    Oxygen saturation nadir as determined by plethysmography

    Measured: Immediate

  2. Change in internal tracheal stenosis diameter

    Change from pre- and post-dilatation values, measured using Myer-Cotton grade and millimeter value

    Measured: 6 weeks post dilatation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Jan 2018
  2. Study start1 Sep 2018 (estimated)
  3. Primary completion30 Dec 2018 (estimated)
  4. Study completion30 Dec 2018 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
Prospective interventional study
Masking
None (open label)
Enrolment
12 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03411928
Sponsor's protocol ID
UCT_ENT_Anaes_201801
Acronym
EDITION2
Status last verified
May 2018
First submitted
9 Jan 2018
Last updated
2 May 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: The data set will be published after study completion using a medium still to be determined. Data set will be available to other researchers on request.

Questions about this trial

What is this clinical trial studying?

A study testing Tracheolator in people with Tracheal Stenosis and Airway Disease, run by University of Cape Town at 1 site in South Africa.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 2 May 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Africa. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Jessica McGuire, FCORL (+27722072991, jessica.mcguire@uct.ac.za), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in internal tracheal stenosis diameter (time frame: Immediate). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 May 2018.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in