Tracheal StenosisEDITION2NCT03411928
Endotracheal Dilator to Improve Oxygenation
A study testing Tracheolator in people with Tracheal Stenosis and Airway Disease, run by University of Cape Town at 1 site in South Africa.
Trial summary
The purpose of the study is to prospectively assess the use of a modified tracheal balloon dilator in children (<13 years old) with subglottic or tracheal stenosis. The hypothesis is that the device will effectively dilate the stenotic segment, whilst maintaining oxygenation (if applicable). Read more about this study
- Who is it for?
- Ages Up to 13 years
- Conditions the study is for
- Tracheal Stenosis, Airway Disease, Pediatric Respiratory Diseases
- What is being tested?
- Tracheolator
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 12 participants
- Where
- 1 siteSouth Africa
- Study dates
- 1 Sep 2018to 30 Dec 2018
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Up to 13 years
- All sexes
- No healthy volunteers
- Child
Who may be able to join
- Refractory stenosis not amenable to balloon dilatation
- Contraindication to balloon dilatation (long-segment stenosis)
- Patient refusal
Who cannot join
- Refractory stenosis not amenable to balloon dilatation
- Contraindication to balloon dilatation (long-segment stenosis)
- Patient refusal
Trial locations and contacts
1 site in 1 country.
South Africa1 site
Groote Schuur Hospital
Cape Town, Western Cape, 7925
Ross Hofmeyr, FCA(SA), +27214045003, ross.hofmeyr@uct.ac.za
Reuben Smith, MBChB
About this study
Official title: Modified Endotracheal Balloon Dilator to Improve Oxygenation During Airway Procedures in Children With Tracheal Stenosis
The purpose of the study is to prospectively assess the use of a modified tracheal balloon dilator in children (<13 years old) with subglottic or tracheal stenosis. The hypothesis is that the device will effectively dilate the stenotic segment, whilst maintaining oxygenation (if applicable). The primary aim is to measure the stenosis prior to, and after dilatation; using diameter and the modified Myer-Cotton grading system. Secondary aims include assessment of stenosis at six-week follow-up and monitoring arterial oxygenation nadir (using peripheral plethysmography) during the procedure.
Read the detailed description
This study is a prospective, single arm, observational study of patients at Red Cross War Memorial Children's Hospital receiving treatment for laryngotracheal stenosis using a modified tracheal dilatation balloon. The tracheal balloon dilatation procedure is clinically well-established and is standard practice in the study institution. In this study, a modified, improved tracheal balloon will be used to treat patients. Data to be collected during the procedure include measurement of the stenotic segment prior to and after dilatation, using both the modified Myer-Cotton grading system and sizing the stenosis using endotracheal tubes diameter, documenting the site of the stenosis (distance from vocal cords), periprocedural oxygen saturation nadir (using plethysmography) and heart rate. All other procedures will be as per routine care. Each procedure will be monitored by a senior anaesthetist who is not a member of the research team. Their role will be to ensure the safety of the patient.
The tracheal balloon dilatation device consists of a catheter tube which has an inflation port at its proximal end and a balloon at its distal end. The balloon is provided in a narrow, folded condition to allow entering and traversing the stenotic portion of the airway. As with all tracheal dilatation balloons, when inflated with an inflator equipped with a pressure manometer, the device generates an outward radial force to dilate the stenotic portion of the airway. The balloon differs from previous devices used for dilatation of tracheal stenosis in that it is modified to have a large central channel when inflated, which allows gas flow through the balloon.
All materials in the device are medical grade and sourced from specialist medical suppliers. The balloons specifically have undergone biocompatibility testing according to ISO 10993-1 (Biological testing of medical devices) and passed all tests. Safety of the devices has been rigorously demonstrated through in vitro bench testing, and balloons have been shown to survive a minimum of 10 inflations to rated burst pressure without bursting. The devices are manufactured by a facility experienced in production of endovascular balloons, in an ISO 14644 Class 7 compliant clean-room in a manufacturing facility that has a certified ISO 13485 quality management system. The balloons are tested as part of an ongoing quality control process, to ensure that tight tolerances are maintained in terms of wall thickness, nominal diameter and rated burst pressure. Furthermore, every tracheal balloon device will have been pressure tested to 16 atm before being used, to ensure that no leaks are present.
The device has been assessed in three previous studies, in manikin, animal and adult human use settings. The studies proved that it is possible to adequately ventilate patients through the modified balloon dilation device. There was no incident of arterial desaturation below 90%. No serious adverse events were recorded.
The study will be conducted over a 12 week period, with an average of 1 patient per week undergoing the procedure at the study site. Recruitment is thus estimated at 12 patients (not procedures).
All research and procedures will take place at Red Cross War Memorial Children's Hospital. Patients will be treated in the operating theatres and will recover in the recovery room, followed by the ENT ward. Patients who have suspected airway narrowing and present to the Department of Otolaryngology will be approached by for potential involvement in the study. The process will be explained obtain written informed consent obtained. The patient will then be treated as per routine care and will be included in the study should inclusion and exclusion criteria be satisfied.
All patients will undergo a thorough routine preoperative assessment. Anaesthesia will be standardized in the absence of specific complication. Routine continuous operative monitoring will be used for all cases, including electrocardiogram, non-invasive automatic blood pressure and pulse oximetry.
A rigid laryngoscope will be inserted into the patient's airway and placed in suspension. The level and severity of the stenosis will be evaluated and the tracheal balloon dilator will be placed at the level of the stenosis under direct vision, using an endoscope. The patient will be kept breathing spontaneously if they do not have a tracheostomy tube. Ventilation will be maintained using a tracheostomy tube, if available.
The balloon will be inflated with water using an inflation device, under direct vision. The pressure in the balloon will be adjusted to 6-8 atmospheres and maintained for at least 1 minute, unless arterial desaturation occurs (SpO2 < 90%) Dilatation will be performed 3 times.
Heart rate and peripheral arterial oxygen saturation will be continuously monitored throughout the procedure. These values will be recorded automatically at one-minute intervals from induction until completion of the dilatation phase, and then at 2.5-minute intervals until recovery from anaesthesia. The stenosis will be graded according to the Myer-Cotton staging system for subglottic stenosis, as well as, the internal diameter of the stenosis being measured (using an endotracheal tube) before and after dilatation.
Adverse events will be recorded in data collection forms. Adverse events will include:
- Arterial desaturation below 90%
- Loss of airway patency
- Inability to ventilate
- Patient coughing or movement
- Haemorrhage
- Inability to pass the bronchoscope
- Balloon failure
- False passage
- Tracheal injury
- Oesophageal injury
- Gastric haemorrhage
- Pneumothorax
- Pneumomediastinum
- Subcutaneous emphysema
- Vocal cord injury
- Mediastinitis
- Chest pain
- Laryngospasm
- Bronchospasm
- Atelectasis
- Pulmonary oedema
- Hypoxia
- Aspiration of water (in case of balloon failure)
Data analysis Data will be collected intraoperatively using a data collection form. This will be transferred to an electronic spreadsheet for analysis. As this is a single-arm study without control devices, no comparative statistics will be calculated. Where appropriate, data will be expressed as mean ± standard deviation.
- Being tested
- Tracheolator
- Medical subject headings
- Tracheal Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
TracheolatorDevice
'Tracheolator' non-occlusive tracheal dilation balloon manufactured by Disa Life Sciences, Cape Town, South Africa.
| Study group | Role | What they receive |
|---|---|---|
| Tracheolator | Experimental | Tracheal dilatation using the study device as per the protocol. Receives: Device: Tracheolator |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in internal tracheal stenosis diameter
Post-dilation change from pre-dilatation values, measured using Myer-Cotton grade and millimeter value
Measured: Immediate
Secondary outcomes (2)
Peripheral arterial oxygenation
Oxygen saturation nadir as determined by plethysmography
Measured: Immediate
Change in internal tracheal stenosis diameter
Change from pre- and post-dilatation values, measured using Myer-Cotton grade and millimeter value
Measured: 6 weeks post dilatation
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Jan 2018
- Study start1 Sep 2018 (estimated)
- Primary completion30 Dec 2018 (estimated)
- Study completion30 Dec 2018 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Tracheal StenosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Prospective interventional study
- Masking
- None (open label)
- Enrolment
- 12 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University of Cape Town
- Sponsor type
- University, hospital or other
- Collaborators
- Red Cross War Memorial Childrens Hospital
- Responsible party
- Principal investigator, Ross Hofmeyr, University of Cape Town
- Investigators
- Ross Hofmeyr, FCA(SA), Principal investigator, University of Cape Town
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03411928
- Sponsor's protocol ID
- UCT_ENT_Anaes_201801
- Acronym
- EDITION2
- Status last verified
- May 2018
- First submitted
- 9 Jan 2018
- Last updated
- 2 May 2018
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided: The data set will be published after study completion using a medium still to be determined. Data set will be available to other researchers on request.
Study at a glance
From the registry record, last updated by the sponsor on 2 May 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Modified Endotracheal Balloon Dilator to Improve Oxygenation During Airway Procedures in Children With Tracheal Stenosis
- ClinicalTrials.gov ID
- NCT03411928
- Acronym / sponsor ID
- EDITION2 / UCT_ENT_Anaes_201801
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 12 participants (estimated)
- Lead sponsor
- University of Cape TownUniversity, hospital or other
- Collaborators
- Red Cross War Memorial Childrens Hospital
- Study start
- 1 Sep 2018 (estimated)
- Primary completion
- 30 Dec 2018 (estimated)
- Study completion
- 30 Dec 2018 (estimated)
- First posted
- 26 Jan 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of the study is to prospectively assess the use of a modified tracheal balloon dilator in children (<13 years old) with subglottic or tracheal stenosis. The hypothesis is that the device will effectively dilate the stenotic segment, whilst maintaining oxygenation (if applicable). The primary aim is to measure the stenosis prior to, and after dilatation; using diameter and the modified Myer-Cotton grading system. Secondary aims include assessment of stenosis at six-week follow-up and monitoring arterial oxygenation nadir (using peripheral plethysmography) during the procedure.
Detailed description
This study is a prospective, single arm, observational study of patients at Red Cross War Memorial Children's Hospital receiving treatment for laryngotracheal stenosis using a modified tracheal dilatation balloon. The tracheal balloon dilatation procedure is clinically well-established and is standard practice in the study institution. In this study, a modified, improved tracheal balloon will be used to treat patients. Data to be collected during the procedure include measurement of the stenotic segment prior to and after dilatation, using both the modified Myer-Cotton grading system and sizing the stenosis using endotracheal tubes diameter, documenting the site of the stenosis (distance from vocal cords), periprocedural oxygen saturation nadir (using plethysmography) and heart rate. All other procedures will be as per routine care. Each procedure will be monitored by a senior anaesthetist who is not a member of the research team. Their role will be to ensure the safety of the patient.
The tracheal balloon dilatation device consists of a catheter tube which has an inflation port at its proximal end and a balloon at its distal end. The balloon is provided in a narrow, folded condition to allow entering and traversing the stenotic portion of the airway. As with all tracheal dilatation balloons, when inflated with an inflator equipped with a pressure manometer, the device generates an outward radial force to dilate the stenotic portion of the airway. The balloon differs from previous devices used for dilatation of tracheal stenosis in that it is modified to have a large central channel when inflated, which allows gas flow through the balloon.
All materials in the device are medical grade and sourced from specialist medical suppliers. The balloons specifically have undergone biocompatibility testing according to ISO 10993-1 (Biological testing of medical devices) and passed all tests. Safety of the devices has been rigorously demonstrated through in vitro bench testing, and balloons have been shown to survive a minimum of 10 inflations to rated burst pressure without bursting. The devices are manufactured by a facility experienced in production of endovascular balloons, in an ISO 14644 Class 7 compliant clean-room in a manufacturing facility that has a certified ISO 13485 quality management system. The balloons are tested as part of an ongoing quality control process, to ensure that tight tolerances are maintained in terms of wall thickness, nominal diameter and rated burst pressure. Furthermore, every tracheal balloon device will have been pressure tested to 16 atm before being used, to ensure that no leaks are present.
The device has been assessed in three previous studies, in manikin, animal and adult human use settings. The studies proved that it is possible to adequately ventilate patients through the modified balloon dilation device. There was no incident of arterial desaturation below 90%. No serious adverse events were recorded.
The study will be conducted over a 12 week period, with an average of 1 patient per week undergoing the procedure at the study site. Recruitment is thus estimated at 12 patients (not procedures).
All research and procedures will take place at Red Cross War Memorial Children's Hospital. Patients will be treated in the operating theatres and will recover in the recovery room, followed by the ENT ward. Patients who have suspected airway narrowing and present to the Department of Otolaryngology will be approached by for potential involvement in the study. The process will be explained obtain written informed consent obtained. The patient will then be treated as per routine care and will be included in the study should inclusion and exclusion criteria be satisfied.
All patients will undergo a thorough routine preoperative assessment. Anaesthesia will be standardized in the absence of specific complication. Routine continuous operative monitoring will be used for all cases, including electrocardiogram, non-invasive automatic blood pressure and pulse oximetry.
A rigid laryngoscope will be inserted into the patient's airway and placed in suspension. The level and severity of the stenosis will be evaluated and the tracheal balloon dilator will be placed at the level of the stenosis under direct vision, using an endoscope. The patient will be kept breathing spontaneously if they do not have a tracheostomy tube. Ventilation will be maintained using a tracheostomy tube, if available.
The balloon will be inflated with water using an inflation device, under direct vision. The pressure in the balloon will be adjusted to 6-8 atmospheres and maintained for at least 1 minute, unless arterial desaturation occurs (SpO2 < 90%) Dilatation will be performed 3 times.
Heart rate and peripheral arterial oxygen saturation will be continuously monitored throughout the procedure. These values will be recorded automatically at one-minute intervals from induction until completion of the dilatation phase, and then at 2.5-minute intervals until recovery from anaesthesia. The stenosis will be graded according to the Myer-Cotton staging system for subglottic stenosis, as well as, the internal diameter of the stenosis being measured (using an endotracheal tube) before and after dilatation.
Adverse events will be recorded in data collection forms. Adverse events will include:
- Arterial desaturation below 90%
- Loss of airway patency
- Inability to ventilate
- Patient coughing or movement
- Haemorrhage
- Inability to pass the bronchoscope
- Balloon failure
- False passage
- Tracheal injury
- Oesophageal injury
- Gastric haemorrhage
- Pneumothorax
- Pneumomediastinum
- Subcutaneous emphysema
- Vocal cord injury
- Mediastinitis
- Chest pain
- Laryngospasm
- Bronchospasm
- Atelectasis
- Pulmonary oedema
- Hypoxia
- Aspiration of water (in case of balloon failure)
Data analysis Data will be collected intraoperatively using a data collection form. This will be transferred to an electronic spreadsheet for analysis. As this is a single-arm study without control devices, no comparative statistics will be calculated. Where appropriate, data will be expressed as mean ± standard deviation.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Prospective interventional study
| Arm | Type | Receives |
|---|---|---|
| Tracheolator | Experimental | Device: TracheolatorTracheal dilatation using the study device as per the protocol. |
Who may qualify
- Ages
- Up to 13 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
Key inclusion criteria (3 listed)
- Refractory stenosis not amenable to balloon dilatation
- Contraindication to balloon dilatation (long-segment stenosis)
- Patient refusal
Key exclusion criteria (3 listed)
- Refractory stenosis not amenable to balloon dilatation
- Contraindication to balloon dilatation (long-segment stenosis)
- Patient refusal
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Tracheolator'Tracheolator' non-occlusive tracheal dilation balloon manufactured by Disa Life Sciences, Cape Town, South Africa. | Device | Tracheolator |
Primary outcome
Change in internal tracheal stenosis diameter
Time frame: Immediate
Post-dilation change from pre-dilatation values, measured using Myer-Cotton grade and millimeter value
2 secondary outcomes
Peripheral arterial oxygenation
Time frame: Immediate
Change in internal tracheal stenosis diameter
Time frame: 6 weeks post dilatation
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 May 2018.
- Individual participant dataSharing planned: Undecided. The data set will be published after study completion using a medium still to be determined. Data set will be available to other researchers on request.
Related trials for Tracheal Stenosis
Not yet recruitingObservational study
Laryngotracheal Lesions in Adults With Long-Term Tracheostomy
Laryngotracheal Lesions, Tracheostomy Complications
RecruitingObservational study
Rare Disease Patient Registry & Natural History Study - Coordination of Rare Diseases at Sanford
Rare Disorders, Undiagnosed Disorders
RecruitingPhase 3
Adjuvant Steroid Outcomes in Idiopathic Subglottic Stenosis
Idiopathic Subglottic Stenosis
Recruiting
Transcriptomic Profile Changes in Benign Tracheal Stenosis: Wedge Resection vs. Radial Incision
Tracheal Stenosis
Enrolling by invitation
Feasibility of Tracheobronchial Reconstruction Using Allogenic Aortic Patch in Children
Trachea Diseases, Tracheal Stenosis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Ross Hofmeyr, FCA(SA) principal investigator
University of Cape Town
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Tracheolator in people with Tracheal Stenosis and Airway Disease, run by University of Cape Town at 1 site in South Africa.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 2 May 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in South Africa. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Jessica McGuire, FCORL (+27722072991, jessica.mcguire@uct.ac.za), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in internal tracheal stenosis diameter (time frame: Immediate). It is what the study was designed to measure, not a finding.