Heart FailureDISCORDANCENCT03661827
Dobutamine vs Adenosine CMR Study
A study testing Stress Cardiac MRI in people with Heart Failure and Coronary Artery Disease, run by University of Leicester at 1 site in United Kingdom.
Trial summary
This is a single centre, prospective diagnostic accuracy study to assess the comparative sensitivity of dobutamine versus adenosine for detection of severe non-infarct epicardial coronary artery stenosis in subjects with reduced LV EF ( EFed referred for clinical coronary angiography for investigation of symptoms or… Read more about this study
- Who is it for?
- Ages 18 to 90 years
- Conditions the study is for
- Heart Failure, Coronary Artery Disease, Cardiac MRI
- What is being tested?
- Stress Cardiac MRI
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 69 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- 5 Feb 2019to 2 Aug 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 90 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- HFrEF (LV EF≤40%, based on either echocardiography, CMR or nuclear perfusion imaging) consistent with recent guidelines for diagnosis of HFrEF [38] referred for investigation of CAD.
- 2. Age ≥18 years ≤90 years old 3. Understand written and verbal English. 4. Patients are not involved in other research studies within the last year.
Who cannot join
- Absolute contraindication to MRI. 2. Absolute contraindication to dobutamine OR adenosine; 3. Stage III-V renal disease (estimated glomerular filtration rate <30ml/min/1.73m2.
- 4. Previous coronary artery bypass grafting. 5. Unstable angina or MI within 6 weeks. 6. Persistent atrial fibrillation 7. Participants who are involved in current research or have recently been involved in any research prior to recruitment 8. Participants who don't speak or understand verbal or written English
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Diagnostic Accuracy in Left Ventricular Systolic Dysfunction for Identifying Coronary Artery Disease With Dobutamine Versus Adenosine Non-invasive Stress Cardiac Magnetic Resonance Evaluation
This is a single centre, prospective diagnostic accuracy study to assess the comparative sensitivity of dobutamine versus adenosine for detection of severe non-infarct epicardial coronary artery stenosis in subjects with reduced LV EF ( EFed referred for clinical coronary angiography for investigation of symptoms or to establish the cause heart failure. Study participants will be identified from hospital angiography referral waiting lists, or already known with CAD and from heart failure outpatient clinics at Glenfield General Hospital. Clinical and CMR data will be collated on-site (at Glenfield General Hospital) from medical records stored and stress cardiac MRI scans at Glenfield General Hospital. The analysis will occur over a 12-month period following study commencement.
Read the detailed description
Aim The primary aim of this study is to assess the comparative sensitivity of adenosine and dobutamine for detection of severe CAD in patients with HFrEF. Secondary aims are to evaluate how the addition of stress perfusion may alter management compared to CMR without stress.
Primary hypothesis:
In patients with HFrEF (EF≤40%), dobutamine perfusion has superior sensitivity to adenosine for the detection of non-infarct severe CAD (>70% epicardial coronary artery stenosis).
Secondary hypotheses The addition of stress perfusion imaging to CMR cine and LGE imaging does not significantly increase the accuracy for determining whether the aetiology of HFrEF is due to CAD or not.
The response to adenosine (haemodynamics/splenic T1) will be inversely related to markers of LV dysfunction/injury (high sensitivity troponin I/B-type natriuretic peptide) and directly to EF.
Reduced myocardial perfusion reserve (<2.0) increases the accuracy of adenosine perfusion to detect CAD.
The biphasic wall motion response to dobutamine is not specific for the detection of severe coronary artery stenosis.
Experimental details and design of proposed investigation Design: prospective cross-sectional study. Subjects: participants will be recruited from the Cardiology Department at Glenfield General Hospital, Leicester, one of the largest secondary and tertiary care units in the UK. Patients referred for invasive coronary angiography to determine the cause of HFrEF or symptomatic angina and EF≤40% will be recruited. Patients will be contacted directly at hospital appointments or by letter after reviewing of case records to ensure eligibility.
Inclusion criteria: 1. HFrEF (LV EF≤40%, consistent with recent guidelines for the diagnosis of HFrEF)[38] referred for investigation of CAD; 2. Age ≥18 years. Exclusion criteria: 1. Absolute contraindication to MRI. 2. Absolute contraindication to dobutamine OR adenosine; 2. Stage III-V renal disease (estimated glomerular filtration rate <30ml/min/1.73m2; 3. Previous coronary artery bypass grafting; 4. Unstable angina or MI within 6 weeks.
Investigations:
- History taking and examination to confirm signs and symptoms of heart failure and obtain a current medical history.
- ECG to determine rhythm, ST-segment and conduction abnormalities. Venepuncture (20mL) for full blood count, biochemistry, high-sensitivity troponin I and B- type natriuretic peptide.
- CMR scanning performed at Glenfield Hospital on a dedicated NIHR 3T research scanner. The investigators have extensive experience of stress CMR for the assessment of CAD, including dobutamine stress. Each CMR study will be supervised by the fellow after appropriate training including safe administration of dobutamine. Patients will be asked to withhold beta-blocker therapy for 48 hours to minimise antagonism to dobutamine. For this study, The investigators will use newly installed software with dual-sequence perfusion that allows fully automated inline quantification of myocardial blood flow utilising advanced image reconstruction algorithms, Gadgetron, in conjunction with our collaborator (Dr Peter Kellman, NIH, Bethesda, USA). This sequence allows both visual analyses for perfusion defects and quantification of myocardial blood flow and perfusion reserve on a pixel by pixel basis. A modified protocol will be undertaken, incorporating:
Cine functional assessment to determine ventricular volumes and function; Adenosine stress perfusion, dobutamine stress wall motion and perfusion, and rest perfusion imaging to assess qualitative perfusion defects, inducible wall motion abnormalities and myocardial perfusion reserve. Dobutamine will be reversed with intravenous metoprolol before undertaking LGE and then rest perfusion.
Delayed contrast enhancement for assessment of LV fibrosis and evidence of previous myocardial infarction. The investigators did consider undertaking adenosine stress CMR and dobutamine stress CMR scans on separate days, to mitigate the effects of contrast remaining affecting perfusion quantification during dobutamine stress testing. However, this would double the expense of CMR scanning in the study and reduce the acceptability to potential participants. The investigators are confident that performing both adenosine and dobutamine stress in one CMR study will not have any material impact on image assessment, as there will be 20 minutes between the two stress sequences.
All patients will have invasive coronary angiography performed as to clinical standards to assess for the presence of CAD, which will be performed within 4 weeks of CMR scanning. Fractional flow reserve will be performed as clinically indicated and given that this may be equally influenced by adenosine down-regulation is not mandated in the protocol.
Image analysis: All imaging will be analysed blinded to patient details. CMR analysis will be undertaken by using dedicated software for research (cmr42, Circle Cardiovascular Imaging, Calgary, Canada). CMR studies will be divided into three series: i) cine and LGE images, ii) cine, adenosine stress and rest perfusion and LGE images, and iii) cine, dobutamine stress and rest and LGE images, and allocated a computer-generated random number identifier prior to analysis. Each of the 16 segments of the left ventricle will be scored for function, infarction, perfusion defects and contractile response as previously described. Qualitative analysis will be performed by the consensus of two readers (the fellow and Dr Arnold) and in cases of disagreement or uncertainty with a third observer (Prof McCann). Splenic switch-off will be assessed qualitatively and quantitatively with T1 mapping for evaluation of the adequacy of vasodilator stress with adenosine. The random number key will not be accessible to staff involved in the analysis until all analyses have been completed and the database has been locked. Image analysis of series I, ii and iii will be performed separately, at least two weeks' apart. Invasive angiography images will be anonymised and reported by a senior clinician or the fellow (after appropriate training and under supervision).
Aetiology of heart failure: will be decided by a "gold" group consisting of an interventional cardiologist, heart failure specialist and cardiac imager (Dr Adlam, Prof Squire and McCann, respectively) who will be presented with all investigations, as per previous studies.
Data handling: To reduce costs, the NIHR Leicester BRC staff have developed electronic databases using the validated and open source REDCap system and CiviCRM for management of recruitment of subjects into clinical studies, research, governance and monitoring. This infrastructure will be available during this programme of study. All imaging data will be entered into REDCap in a blinded fashion and will only be unblinded for statistical analysis when the database is locked. This will ensure the integrity of the data and any changes may be audited.
Statistical analysis: Data will be examined for normality and summarised. Non-normally distributed data will be transformed to achieve normality prior to analysis. CMR image series will be compared by paired t-tests, Mann-Whitney and Chi-squared tests as appropriate. The sensitivities, specificities and accuracy of adenosine stress and dobutamine stress imaging for identifying non-infarct related ischemia will be compared. The kappa statistic will be used as a measure of agreement in diagnoses between series. Correlation coefficients will be assessed for adenosine response v markers of LV dysfunction.
Power calculations The power calculation has been performed with the assistance of Dr C Nelson, Lecturer in Medical Statistics. From our pilot data, the sensitivity of adenosine for detecting non-infarct related myocardial perfusion abnormalities as our baseline standard is 62%. The investigators estimate that the sensitivity of dobutamine for detecting perfusion abnormalities is 82%, as shown by Mordi et al. in patients with left bundle branch block at a maximum dobutamine dose of only 20μg/kg/min. Assuming the prevalence of CAD is 50% and dobutamine has sensitivity 20% higher than adenosine (Delta=0.82-0.62), 86 patients are required for 80% power at the 5% alpha level. To allow for technical issues with failure of either of adenosine, dobutamine or LGE or for patients who may decide not to proceed with invasive coronary angiography, investigators will recruit 100 patients. If all 100 patients completed the assessments investigators would have 80% power to detect an 18% increase in sensitivity with dobutamine.
Bias and confounders The investigators will aim to recruit consecutive patients to avoid selection bias. Ascertainment bias will be minimised by robust blinding of CMR scans as outlined above. As the dobutamine and adenosine stress images will be acquired in the same patients, there is no confounding in selection between the two perfusion arms. The investigators are confident that the accuracy of the dobutamine perfusion will not be compromised by prior administration of contrast for adenosine perfusion due the relatively small dose used (0.05mmol/kg at 3T) and with the long time interval (~20mins) between contrast injections, allowing clearance.
Timeline The investigators perform over 1000 clinical stress examinations and over 1200 invasive coronary angiograms annually, many in patients meeting the inclusion criteria. The investigators aim to recruit a minimum of one patient per week and the study will be completed in under two years.
The expected value of results This study will be the first to compare the diagnostic accuracy of adenosine versus dobutamine stress CMR for the detection of CAD in patients with HFrEF. If the results confirm that adenosine has poor sensitivity for the detection of CAD and that dobutamine is superior then the study will challenge the current paradigm of combined adenosine perfusion and CMR viability assessment. However before clinical practice is changed the investigators would plan to conduct a multicentre trial through BSCMR research group, which has a strong track record in multicentre clinical trials.
- Conditions
- Heart Failure, Coronary Artery Disease, Cardiac MRI
- Being tested
- Stress Cardiac MRI
- Medical subject headings
- Heart Failure, Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Stress Cardiac MRIDiagnostic test
Dobutamine and adenosine stress MRI
| Study group | Role | What they receive |
|---|---|---|
| Patients with heart failure | Experimental | Patients with heart failure Receives: Diagnostic Test: Stress Cardiac MRI |
What is being measured
The primary outcome is the main question the study is designed to answer.
Presence of severe CAD (stenosis >70%) on invasive angiography and will be assessed on a per vessel basis
if positive
Measured: 2 years
Secondary outcomes (3)
Haemodynamic/splenic T1 mapping value in (ms) to adenosine by cardiac MRI scan.
if positive
Measured: 2 years
Myocardial perfusion reserve (ml/min/g) by cardiac MRI scan.
if positive
Measured: 2 years
Presence of inducible wall motion abnormality as a response to dobutamine by Cardiac MRI
if positive
Measured: 2 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Sep 2018
- Study start5 Feb 2019
- Primary completion2 Aug 2023
- Study completion2 Aug 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (12)Papers the sponsor has linked to this study.
- Other trials for Heart FailureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 69 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Leicester
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Jayanth Arnold, Dr, Principal investigator, University of Leicester
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03661827
- Sponsor's protocol ID
- 0683
- Acronym
- DISCORDANCE
- Status last verified
- Jan 2023
- First submitted
- 28 Aug 2018
- Last updated
- 30 Nov 2023
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Greenwood JP, Maredia N, Younger JF, Brown JM, Nixon J, Everett CC, Bijsterveld P, Ridgway JP, Radjenovic A, Dickinson CJ, Ball SG, Plein S. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet. 2012 Feb 4;379(9814):453-60. doi: 10.1016/S0140-6736(11)61335-4. Epub 2011 Dec 22.
PubMed 22196944Hamirani YS, Kramer CM. Cardiac MRI assessment of myocardial perfusion. Future Cardiol. 2014 May;10(3):349-58. doi: 10.2217/fca.14.18.
PubMed 24976472Klem I, Heitner JF, Shah DJ, Sketch MH Jr, Behar V, Weinsaft J, Cawley P, Parker M, Elliott M, Judd RM, Kim RJ. Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging. J Am Coll Cardiol. 2006 Apr 18;47(8):1630-8. doi: 10.1016/j.jacc.2005.10.074. Epub 2006 Mar 27.
PubMed 16631001Morton G, Chiribiri A, Ishida M, Hussain ST, Schuster A, Indermuehle A, Perera D, Knuuti J, Baker S, Hedstrom E, Schleyer P, O'Doherty M, Barrington S, Nagel E. Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography. J Am Coll Cardiol. 2012 Oct 16;60(16):1546-55. doi: 10.1016/j.jacc.2012.05.052. Epub 2012 Sep 19.
PubMed 22999722Karamitsos TD, Arnold JR, Pegg TJ, Cheng AS, van Gaal WJ, Francis JM, Banning AP, Neubauer S, Selvanayagam JB. Tolerance and safety of adenosine stress perfusion cardiovascular magnetic resonance imaging in patients with severe coronary artery disease. Int J Cardiovasc Imaging. 2009 Mar;25(3):277-83. doi: 10.1007/s10554-008-9392-3. Epub 2008 Nov 27.
PubMed 19037746Bruder O, Wagner A, Lombardi M, Schwitter J, van Rossum A, Pilz G, Nothnagel D, Steen H, Petersen S, Nagel E, Prasad S, Schumm J, Greulich S, Cagnolo A, Monney P, Deluigi CC, Dill T, Frank H, Sabin G, Schneider S, Mahrholdt H. European Cardiovascular Magnetic Resonance (EuroCMR) registry--multi national results from 57 centers in 15 countries. J Cardiovasc Magn Reson. 2013 Jan 18;15(1):9. doi: 10.1186/1532-429X-15-9.
PubMed 23331632Khoo JP, Grundy BJ, Steadman CD, Sonnex EP, Coulden RA, McCann GP. Stress cardiovascular MR in routine clinical practice: referral patterns, accuracy, tolerance, safety and incidental findings. Br J Radiol. 2012 Oct;85(1018):e851-7. doi: 10.1259/bjr/14829242. Epub 2012 Mar 28.
PubMed 22457320Wilson RF, Wyche K, Christensen BV, Zimmer S, Laxson DD. Effects of adenosine on human coronary arterial circulation. Circulation. 1990 Nov;82(5):1595-606. doi: 10.1161/01.cir.82.5.1595.
PubMed 2225364Gerber BL, Raman SV, Nayak K, Epstein FH, Ferreira P, Axel L, Kraitchman DL. Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art. J Cardiovasc Magn Reson. 2008 Apr 28;10(1):18. doi: 10.1186/1532-429X-10-18.
PubMed 18442372Kramer CM, Barkhausen J, Flamm SD, Kim RJ, Nagel E; Society for Cardiovascular Magnetic Resonance Board of Trustees Task Force on Standardized Protocols. Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update. J Cardiovasc Magn Reson. 2013 Oct 8;15(1):91. doi: 10.1186/1532-429X-15-91.
PubMed 24103764Schwitter J, Wacker CM, van Rossum AC, Lombardi M, Al-Saadi N, Ahlstrom H, Dill T, Larsson HB, Flamm SD, Marquardt M, Johansson L. MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial. Eur Heart J. 2008 Feb;29(4):480-9. doi: 10.1093/eurheartj/ehm617. Epub 2008 Jan 21.
PubMed 18208849Shergill S, Abdelaty AMSEK, Sedani SR, Moafi A, Athithan L, Bilak JM, Elshibly M, Nehikhare I, Olusan AA, Jaspal P, Hetherington SL, Alama M, Kellman P, Adlam D, Levelt E, Singh A, Squire IB, Hothi SS, Khoo J, Gulsin GS, McCann GP, Arnold JR. Hyperaemic effects of adenosine and dobutamine in heart failure with reduced ejection fraction: a quantitative perfusion CMR study. Eur Heart J Imaging Methods Pract. 2026 Jul 16;4(3):qyag128. doi: 10.1093/ehjimp/qyag128. eCollection 2026 Aug.
PubMed 42549380
Study at a glance
From the registry record, last updated by the sponsor on 30 Nov 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Diagnostic Accuracy in Left Ventricular Systolic Dysfunction for Identifying Coronary Artery Disease With Dobutamine Versus Adenosine Non-invasive Stress Cardiac Magnetic Resonance Evaluation
- ClinicalTrials.gov ID
- NCT03661827
- Acronym / sponsor ID
- DISCORDANCE / 0683
- Conditions
- Heart Failure, Coronary Artery Disease, Cardiac MRI
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 69 participants (actual)
- Lead sponsor
- University of LeicesterUniversity, hospital or other
- Study start
- 5 Feb 2019 (actual)
- Primary completion
- 2 Aug 2023 (actual)
- Study completion
- 2 Aug 2023 (actual)
- First posted
- 7 Sep 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a single centre, prospective diagnostic accuracy study to assess the comparative sensitivity of dobutamine versus adenosine for detection of severe non-infarct epicardial coronary artery stenosis in subjects with reduced LV EF ( EFed referred for clinical coronary angiography for investigation of symptoms or to establish the cause heart failure. Study participants will be identified from hospital angiography referral waiting lists, or already known with CAD and from heart failure outpatient clinics at Glenfield General Hospital. Clinical and CMR data will be collated on-site (at Glenfield General Hospital) from medical records stored and stress cardiac MRI scans at Glenfield General Hospital. The analysis will occur over a 12-month period following study commencement.
Detailed description
Aim The primary aim of this study is to assess the comparative sensitivity of adenosine and dobutamine for detection of severe CAD in patients with HFrEF. Secondary aims are to evaluate how the addition of stress perfusion may alter management compared to CMR without stress.
Primary hypothesis:
In patients with HFrEF (EF≤40%), dobutamine perfusion has superior sensitivity to adenosine for the detection of non-infarct severe CAD (>70% epicardial coronary artery stenosis).
Secondary hypotheses The addition of stress perfusion imaging to CMR cine and LGE imaging does not significantly increase the accuracy for determining whether the aetiology of HFrEF is due to CAD or not.
The response to adenosine (haemodynamics/splenic T1) will be inversely related to markers of LV dysfunction/injury (high sensitivity troponin I/B-type natriuretic peptide) and directly to EF.
Reduced myocardial perfusion reserve (<2.0) increases the accuracy of adenosine perfusion to detect CAD.
The biphasic wall motion response to dobutamine is not specific for the detection of severe coronary artery stenosis.
Experimental details and design of proposed investigation Design: prospective cross-sectional study. Subjects: participants will be recruited from the Cardiology Department at Glenfield General Hospital, Leicester, one of the largest secondary and tertiary care units in the UK. Patients referred for invasive coronary angiography to determine the cause of HFrEF or symptomatic angina and EF≤40% will be recruited. Patients will be contacted directly at hospital appointments or by letter after reviewing of case records to ensure eligibility.
Inclusion criteria: 1. HFrEF (LV EF≤40%, consistent with recent guidelines for the diagnosis of HFrEF)[38] referred for investigation of CAD; 2. Age ≥18 years. Exclusion criteria: 1. Absolute contraindication to MRI. 2. Absolute contraindication to dobutamine OR adenosine; 2. Stage III-V renal disease (estimated glomerular filtration rate <30ml/min/1.73m2; 3. Previous coronary artery bypass grafting; 4. Unstable angina or MI within 6 weeks.
Investigations:
- History taking and examination to confirm signs and symptoms of heart failure and obtain a current medical history.
- ECG to determine rhythm, ST-segment and conduction abnormalities. Venepuncture (20mL) for full blood count, biochemistry, high-sensitivity troponin I and B- type natriuretic peptide.
- CMR scanning performed at Glenfield Hospital on a dedicated NIHR 3T research scanner. The investigators have extensive experience of stress CMR for the assessment of CAD, including dobutamine stress. Each CMR study will be supervised by the fellow after appropriate training including safe administration of dobutamine. Patients will be asked to withhold beta-blocker therapy for 48 hours to minimise antagonism to dobutamine. For this study, The investigators will use newly installed software with dual-sequence perfusion that allows fully automated inline quantification of myocardial blood flow utilising advanced image reconstruction algorithms, Gadgetron, in conjunction with our collaborator (Dr Peter Kellman, NIH, Bethesda, USA). This sequence allows both visual analyses for perfusion defects and quantification of myocardial blood flow and perfusion reserve on a pixel by pixel basis. A modified protocol will be undertaken, incorporating:
Cine functional assessment to determine ventricular volumes and function; Adenosine stress perfusion, dobutamine stress wall motion and perfusion, and rest perfusion imaging to assess qualitative perfusion defects, inducible wall motion abnormalities and myocardial perfusion reserve. Dobutamine will be reversed with intravenous metoprolol before undertaking LGE and then rest perfusion.
Delayed contrast enhancement for assessment of LV fibrosis and evidence of previous myocardial infarction. The investigators did consider undertaking adenosine stress CMR and dobutamine stress CMR scans on separate days, to mitigate the effects of contrast remaining affecting perfusion quantification during dobutamine stress testing. However, this would double the expense of CMR scanning in the study and reduce the acceptability to potential participants. The investigators are confident that performing both adenosine and dobutamine stress in one CMR study will not have any material impact on image assessment, as there will be 20 minutes between the two stress sequences.
All patients will have invasive coronary angiography performed as to clinical standards to assess for the presence of CAD, which will be performed within 4 weeks of CMR scanning. Fractional flow reserve will be performed as clinically indicated and given that this may be equally influenced by adenosine down-regulation is not mandated in the protocol.
Image analysis: All imaging will be analysed blinded to patient details. CMR analysis will be undertaken by using dedicated software for research (cmr42, Circle Cardiovascular Imaging, Calgary, Canada). CMR studies will be divided into three series: i) cine and LGE images, ii) cine, adenosine stress and rest perfusion and LGE images, and iii) cine, dobutamine stress and rest and LGE images, and allocated a computer-generated random number identifier prior to analysis. Each of the 16 segments of the left ventricle will be scored for function, infarction, perfusion defects and contractile response as previously described. Qualitative analysis will be performed by the consensus of two readers (the fellow and Dr Arnold) and in cases of disagreement or uncertainty with a third observer (Prof McCann). Splenic switch-off will be assessed qualitatively and quantitatively with T1 mapping for evaluation of the adequacy of vasodilator stress with adenosine. The random number key will not be accessible to staff involved in the analysis until all analyses have been completed and the database has been locked. Image analysis of series I, ii and iii will be performed separately, at least two weeks' apart. Invasive angiography images will be anonymised and reported by a senior clinician or the fellow (after appropriate training and under supervision).
Aetiology of heart failure: will be decided by a "gold" group consisting of an interventional cardiologist, heart failure specialist and cardiac imager (Dr Adlam, Prof Squire and McCann, respectively) who will be presented with all investigations, as per previous studies.
Data handling: To reduce costs, the NIHR Leicester BRC staff have developed electronic databases using the validated and open source REDCap system and CiviCRM for management of recruitment of subjects into clinical studies, research, governance and monitoring. This infrastructure will be available during this programme of study. All imaging data will be entered into REDCap in a blinded fashion and will only be unblinded for statistical analysis when the database is locked. This will ensure the integrity of the data and any changes may be audited.
Statistical analysis: Data will be examined for normality and summarised. Non-normally distributed data will be transformed to achieve normality prior to analysis. CMR image series will be compared by paired t-tests, Mann-Whitney and Chi-squared tests as appropriate. The sensitivities, specificities and accuracy of adenosine stress and dobutamine stress imaging for identifying non-infarct related ischemia will be compared. The kappa statistic will be used as a measure of agreement in diagnoses between series. Correlation coefficients will be assessed for adenosine response v markers of LV dysfunction.
Power calculations The power calculation has been performed with the assistance of Dr C Nelson, Lecturer in Medical Statistics. From our pilot data, the sensitivity of adenosine for detecting non-infarct related myocardial perfusion abnormalities as our baseline standard is 62%. The investigators estimate that the sensitivity of dobutamine for detecting perfusion abnormalities is 82%, as shown by Mordi et al. in patients with left bundle branch block at a maximum dobutamine dose of only 20μg/kg/min. Assuming the prevalence of CAD is 50% and dobutamine has sensitivity 20% higher than adenosine (Delta=0.82-0.62), 86 patients are required for 80% power at the 5% alpha level. To allow for technical issues with failure of either of adenosine, dobutamine or LGE or for patients who may decide not to proceed with invasive coronary angiography, investigators will recruit 100 patients. If all 100 patients completed the assessments investigators would have 80% power to detect an 18% increase in sensitivity with dobutamine.
Bias and confounders The investigators will aim to recruit consecutive patients to avoid selection bias. Ascertainment bias will be minimised by robust blinding of CMR scans as outlined above. As the dobutamine and adenosine stress images will be acquired in the same patients, there is no confounding in selection between the two perfusion arms. The investigators are confident that the accuracy of the dobutamine perfusion will not be compromised by prior administration of contrast for adenosine perfusion due the relatively small dose used (0.05mmol/kg at 3T) and with the long time interval (~20mins) between contrast injections, allowing clearance.
Timeline The investigators perform over 1000 clinical stress examinations and over 1200 invasive coronary angiograms annually, many in patients meeting the inclusion criteria. The investigators aim to recruit a minimum of one patient per week and the study will be completed in under two years.
The expected value of results This study will be the first to compare the diagnostic accuracy of adenosine versus dobutamine stress CMR for the detection of CAD in patients with HFrEF. If the results confirm that adenosine has poor sensitivity for the detection of CAD and that dobutamine is superior then the study will challenge the current paradigm of combined adenosine perfusion and CMR viability assessment. However before clinical practice is changed the investigators would plan to conduct a multicentre trial through BSCMR research group, which has a strong track record in multicentre clinical trials.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Patients with heart failure | Experimental | Diagnostic Test: Stress Cardiac MRIPatients with heart failure |
Who may qualify
- Ages
- 18 to 90 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- HFrEF (LV EF≤40%, based on either echocardiography, CMR or nuclear perfusion imaging) consistent with recent guidelines for diagnosis of HFrEF [38] referred for investigation of CAD.
- 2. Age ≥18 years ≤90 years old 3. Understand written and verbal English. 4. Patients are not involved in other research studies within the last year.
Key exclusion criteria (2 listed)
- Absolute contraindication to MRI. 2. Absolute contraindication to dobutamine OR adenosine; 3. Stage III-V renal disease (estimated glomerular filtration rate <30ml/min/1.73m2.
- 4. Previous coronary artery bypass grafting. 5. Unstable angina or MI within 6 weeks. 6. Persistent atrial fibrillation 7. Participants who are involved in current research or have recently been involved in any research prior to recruitment 8. Participants who don't speak or understand verbal or written English
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Stress Cardiac MRIDobutamine and adenosine stress MRI | Diagnostic test | Patients with heart failure |
Primary outcome
Presence of severe CAD (stenosis >70%) on invasive angiography and will be assessed on a per vessel basis
Time frame: 2 years
if positive
3 secondary outcomes
Haemodynamic/splenic T1 mapping value in (ms) to adenosine by cardiac MRI scan.
Time frame: 2 years
Myocardial perfusion reserve (ml/min/g) by cardiac MRI scan.
Time frame: 2 years
Presence of inducible wall motion abnormality as a response to dobutamine by Cardiac MRI
Time frame: 2 years
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Nov 2023.
- Background: PubMed 22196944Greenwood JP, Maredia N, Younger JF, Brown JM, Nixon J, Everett CC, Bijsterveld P, Ridgway JP, Radjenovic A, Dickinson CJ, Ball SG, Plein S. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet. 2012 Feb 4;379(9814):453-60. doi: 10.1016/S0140-6736(11)61335-4. Epub 2011 Dec 22.
- Background: PubMed 24976472Hamirani YS, Kramer CM. Cardiac MRI assessment of myocardial perfusion. Future Cardiol. 2014 May;10(3):349-58. doi: 10.2217/fca.14.18.
- Background: PubMed 16631001Klem I, Heitner JF, Shah DJ, Sketch MH Jr, Behar V, Weinsaft J, Cawley P, Parker M, Elliott M, Judd RM, Kim RJ. Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging. J Am Coll Cardiol. 2006 Apr 18;47(8):1630-8. doi: 10.1016/j.jacc.2005.10.074. Epub 2006 Mar 27.
- Background: PubMed 22999722Morton G, Chiribiri A, Ishida M, Hussain ST, Schuster A, Indermuehle A, Perera D, Knuuti J, Baker S, Hedstrom E, Schleyer P, O'Doherty M, Barrington S, Nagel E. Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography. J Am Coll Cardiol. 2012 Oct 16;60(16):1546-55. doi: 10.1016/j.jacc.2012.05.052. Epub 2012 Sep 19.
- Background: PubMed 19037746Karamitsos TD, Arnold JR, Pegg TJ, Cheng AS, van Gaal WJ, Francis JM, Banning AP, Neubauer S, Selvanayagam JB. Tolerance and safety of adenosine stress perfusion cardiovascular magnetic resonance imaging in patients with severe coronary artery disease. Int J Cardiovasc Imaging. 2009 Mar;25(3):277-83. doi: 10.1007/s10554-008-9392-3. Epub 2008 Nov 27.
- Background: PubMed 23331632Bruder O, Wagner A, Lombardi M, Schwitter J, van Rossum A, Pilz G, Nothnagel D, Steen H, Petersen S, Nagel E, Prasad S, Schumm J, Greulich S, Cagnolo A, Monney P, Deluigi CC, Dill T, Frank H, Sabin G, Schneider S, Mahrholdt H. European Cardiovascular Magnetic Resonance (EuroCMR) registry--multi national results from 57 centers in 15 countries. J Cardiovasc Magn Reson. 2013 Jan 18;15(1):9. doi: 10.1186/1532-429X-15-9.
- Background: PubMed 22457320Khoo JP, Grundy BJ, Steadman CD, Sonnex EP, Coulden RA, McCann GP. Stress cardiovascular MR in routine clinical practice: referral patterns, accuracy, tolerance, safety and incidental findings. Br J Radiol. 2012 Oct;85(1018):e851-7. doi: 10.1259/bjr/14829242. Epub 2012 Mar 28.
- Background: PubMed 2225364Wilson RF, Wyche K, Christensen BV, Zimmer S, Laxson DD. Effects of adenosine on human coronary arterial circulation. Circulation. 1990 Nov;82(5):1595-606. doi: 10.1161/01.cir.82.5.1595.
- Background: PubMed 18442372Gerber BL, Raman SV, Nayak K, Epstein FH, Ferreira P, Axel L, Kraitchman DL. Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art. J Cardiovasc Magn Reson. 2008 Apr 28;10(1):18. doi: 10.1186/1532-429X-10-18.
- Background: PubMed 24103764Kramer CM, Barkhausen J, Flamm SD, Kim RJ, Nagel E; Society for Cardiovascular Magnetic Resonance Board of Trustees Task Force on Standardized Protocols. Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update. J Cardiovasc Magn Reson. 2013 Oct 8;15(1):91. doi: 10.1186/1532-429X-15-91.
- Results publication: PubMed 18208849Schwitter J, Wacker CM, van Rossum AC, Lombardi M, Al-Saadi N, Ahlstrom H, Dill T, Larsson HB, Flamm SD, Marquardt M, Johansson L. MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial. Eur Heart J. 2008 Feb;29(4):480-9. doi: 10.1093/eurheartj/ehm617. Epub 2008 Jan 21.
- Derived from this study: PubMed 42549380Shergill S, Abdelaty AMSEK, Sedani SR, Moafi A, Athithan L, Bilak JM, Elshibly M, Nehikhare I, Olusan AA, Jaspal P, Hetherington SL, Alama M, Kellman P, Adlam D, Levelt E, Singh A, Squire IB, Hothi SS, Khoo J, Gulsin GS, McCann GP, Arnold JR. Hyperaemic effects of adenosine and dobutamine in heart failure with reduced ejection fraction: a quantitative perfusion CMR study. Eur Heart J Imaging Methods Pract. 2026 Jul 16;4(3):qyag128. doi: 10.1093/ehjimp/qyag128. eCollection 2026 Aug.
- Individual participant dataSharing planned: No
Related trials for Heart Failure
Recruiting
Evaluation of Fibroscan® Performance in Diagnosing Acute Heart Failure in Patients Presenting to the Emergency Department
Acute Heart Failure (AHF)
RecruitingPhase 3
A Study to Learn More About How Safe Finerenone is, When it is Taken for a Longer Time With Standard Treatment, in Children and Young Adults With Heart Failure and Left Ventricular Systolic Dysfunction
Left Ventricular Systolic Dysfunction, Heart Failure (Pediatric)
Enrolling by invitationObservational study
Multi-Scale Analysis of Phenotypes in Heart Failure (MAP-HEART)
Heart Failure
RecruitingObservational study
Cardiogenic Shock Working Group Registry
Cardiogenic Shock
RecruitingPhase 3
Optimal Diuretic Therapies for Acute Heart Failure With Volume Overload
Acute Heart Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jayanth Arnold, Dr principal investigator
University of Leicester
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Stress Cardiac MRI in people with Heart Failure and Coronary Artery Disease, run by University of Leicester at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 30 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Presence of severe CAD (stenosis >70%) on invasive angiography and will be assessed on a per vessel basis (time frame: 2 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03661827, which also lists 12 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Nov 2023.