Physiological Control for Mechanical Circulatory Devices

A study of Heart Failure, run by Heinrich Schima at 1 site in Austria.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Aim of this clinical study is to compare our newly developed control algorithms for mechanical circulatory support devices based on physiological demand with the standard manual LVAD speed operation. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Heart Failure
Type of treatment
Medical device
How many people
7 participants
Where
1 siteAustria
Study dates
14 Dec 2020to 26 May 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • All patients with a Medtronic HVAD system implanted at the Medical University of Vienna, Division of Cardiac Surgery, which are able and willing to understand and sign the informed consent form, and which do not meet any exclusion criteria will be included.

Who cannot join

  • Inability to provide informed consent
  • Patients with known intraventricular or aortic root thrombus formation confirmed by transthoracic ultrasound diagnostic
  • Known pathology of the coagulatory system
  • Supra or sub-therapeutic anticoagulation (aPTT or INR)
  • Suspected or confirmed pump thrombus (based on lab parameters, abnormal high pump power consumption or acoustic spectral analysis)
  • History of ischemic or hemorrhagic stroke (<2 months)
Show all 14Show fewer
  • Hypertension at rest (mean arterial pressure > 120mmHg)
  • Cerebrovascular or musculoskeletal disease preventing the performance of daily life activities or exercise training
  • Severe arrhythmia (e.g. long QT syndrome), ventricular fibrillation or required defibrillation - excluding the LVAD implantation - in the previous 2 months
  • All contraindications applicable to the HVAS are applicable to this study.
  • The System is contraindicated:
  • In patients with a body surface area (BSA) less than 1.2 m²
  • In patients who cannot tolerate anticoagulation therapy
  • During pregnancy

Trial locations and contacts

1 site in 1 country.

Austria1 site
  • Medical University of Vienna

    Vienna, 1090

Other trials in Austria

About this study

Official title: Pilot Study for the Evaluation of Control Algorithms for Mechanical Circulatory Support Devices Based on Physiological Demand

Aim of this clinical study is to compare our newly developed control algorithms for mechanical circulatory support devices based on physiological demand with the standard manual LVAD speed operation. Specifically it shall be demonstrated that:

  • Suction is properly detected by the pre-trained pump flow estimation algorithm
  • Suction events (due to changes in physiological demand) can be reduced by control algorithms compared to continuous speed
  • If suction is encountered, it can be detected and cleared
  • The pump reacts adequately to changes in patient demand due to physical activity
  • Physicians pump setpoints (of requested speed for a certain heartrate) can be achieved safely.
Read the detailed description

Patients complete a set of tests in constant speed setting and repeat the same tests with physiological control algorithms turned on. Order is randomized.

Conditions
Heart Failure
Being tested
Physiological Control Module for the Medtronic -"HVAD" Left Ventricular Assist Device
Keywords
LVAD, Physiological Control
Medical subject headings
Heart Failure

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Physiological Control Module for the Medtronic -"HVAD" Left Ventricular Assist DeviceDevice

    Also called Automatic Speed Adaptation for Left Ventricular Assist Devices

    Software, which sets the device speed according to physiological demand, is activated for the duration of the tests (up to 4 hours). Every patient provides his/her own control, because sequences with active control and with standard pump operation are subsequently performed in randomized order (determined by permutated blocks).

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Device Feasibility

    Feasibility of the Control algorithm to safely adapt pump speed within provided limits, quantified by the number of necessary switchovers to manual mode

    Measured: duration of the testing (up to 4 hours)

Secondary outcomes (2)
  1. Quantification of overpumping by number of suction events / minute during lying, standing and sitting and comparison with constant speed mode.

    Overpumping leads to occlusion of the pump inflow by the ventricular septum and sudden temporary decrease of flow. The number of such events can be counted by analysis of the flow pattern in the pump. The automatic control should lead to a reduction of such events per minute compared to the condition in constant speed.

    Measured: Duration of the testing (up to 4 hours)

  2. Quantification of overpumping by number of suction events / minute due to change of position from lying sitting and sitting to standing compared to the situation in constant speed mode.

    Due to decreased venous return at changes of orthostasis the number of suctions increases in constant speed mode. The control should lead to a reduction of suction events due to intermittent reduction of pump speed. The quantification shall be done by comparing the number of suction events/minute immedeately after such changes in controlled and constant speed mode.

    Measured: Duration of the testing (up to 4 hours)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Mar 2021
  2. Study start14 Dec 2020
  3. Primary completion26 May 2021
  4. Study completion26 May 2021

Why it stopped: The HVAD, which is the device to which the control algorithms are applied, was discontinued by the manufacturer.

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Randomised
Intervention model
Crossover
Model description
Patients undergo testings in constant speed mode and physiologically controlled mode on the same day. the sequence is randomized. The number of patients was chosen due to the fact (experience in clinical care of the patients) the anatomical situation, the pump position due to surgical implant and the patient condition can vary to a high extent.
Masking
Single blind
Who is masked
Participant
Enrolment
7 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04786236
Sponsor's protocol ID
REGALVAD
Acronym
REGALVAD
Status last verified
Dec 2021
First submitted
2 Feb 2021
Last updated
6 Jan 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Maw M, Schloglhofer T, Marko C, Aigner P, Gross C, Widhalm G, Schaefer AK, Schima M, Wittmann F, Wiedemann D, Moscato F, Kudlik D, Stadler R, Zimpfer D, Schima H. A Sensorless Modular Multiobjective Control Algorithm for Left Ventricular Assist Devices: A Clinical Pilot Study. Front Cardiovasc Med. 2022 Apr 25;9:888269. doi: 10.3389/fcvm.2022.888269. eCollection 2022.

    PubMed 35548436

Questions about this trial

What is this clinical trial studying?

A study of Heart Failure, run by Heinrich Schima at 1 site in Austria.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 14 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 6 Jan 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Austria. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: The HVAD, which is the device to which the control algorithms are applied, was discontinued by the manufacturer.). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Device Feasibility (time frame: duration of the testing (up to 4 hours)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04786236, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Jan 2022.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
REGALVAD Clinical Trial NCT04786236 | AzTrials