AzTrials
AzTrials

Blood PressureNEXFIN-NRINCT05283824

Comparison of 3 Techniques for Blood Pressure Measurements During Interventional Neuroradiology Procedures

An observational study of Blood Pressure, run by University Hospital, Brest at 1 site in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Some observational studies demonstrated that hypotension was associated with post-operative morbidity. During neuroradiological procedures, cerebral perfusion pressure should be cautiously maintained and hypertension should also be avoided. So, a precise arterial pressure measurement is needed during this procedures. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Blood Pressure
How many people
50 participants
Where
1 siteFrance
Study dates
19 Mar 2022to 8 Nov 2022
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Adult patients, admitted in operating room elective or emergent neuroradiological procedure

Who may be able to join

  • Adult patients (Age > 18 years old)
  • Elective or emergent neuroradiological procedure under general or local anesthesia for : Endovascular treatment of cerebral aneurysms / arteriovenous malformation, Thrombectomy, Arteriography, transluminal balloon angioplasty for vasospasm
  • Placement of arterial catheter for the measurement of continuous arterial pressure

Who cannot join

  • Contraindication of placement of arterial catheter or digital cuff (Clearsight) such as: Reynaud syndrome, Buerger syndrome
  • Pregnant women
  • Refusal

Trial locations and contacts

1 site in 1 country.

France1 site
  • CHRU de Brest

    Brest, 29609

Other trials in France

About this study

Some observational studies demonstrated that hypotension was associated with post-operative morbidity. During neuroradiological procedures, cerebral perfusion pressure should be cautiously maintained and hypertension should also be avoided. So, a precise arterial pressure measurement is needed during this procedures. A continuous monitoring of arterial pressure needed the placement of an arterial catheter in radial artery. The placement of this catheter might be long, difficult and incompatible with emergency neuroradiological procedure (such as thrombectomy). Then, this invasive technique is associated with several minor and major side effects such as: pain, infection, thrombosis, hematoma.

The Clearsight®, commercialized by Edwards Life Science Company®, is a non invasive device which mesure continuously arterial pressure with Volume-Clamp method. In operating room, some studies found a good accuracy between Clearsight® and other invasive monitoring system. There is no description of the use of Clearsight® during neuroradiological procedures.

The investigators hypothesized that Clearsight® measurement of arterial pressure are concordant with arterial pressure measure with the placement of an arterial catheter. The investigators also plan to evaluate accuracy of intermittent non invasive pressure measurement with traditional cuff.

Conditions
Blood Pressure

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Systolic arterial blood pressure (mmHg)

    The main objective of this study is to evaluate concordance of systolic arterial pressure pressure (in mmHg) measurement between invasive (arterial catheter) and non invasive technique (Clearsight©)

    Measured: During neuroradiological procedure

  2. Diastolic arterial blood pressure (mmHg)

    The main objective of this study is to evaluate concordance of diastolic arterial pressure pressure (in mmHg) measurement between invasive (arterial catheter) and non invasive technique (Clearsight©)

    Measured: During neuroradiological procedure

  3. Mean arterial blood pressure (mmHg)

    The main objective of this study is to evaluate concordance of mean arterial pressure pressure (in mmHg) measurement between invasive (arterial catheter) and non invasive technique (Clearsight©)

    Measured: During neuroradiological procedure

Secondary outcomes (3)
  1. Systolic arterial blood pressure (mmHg)

    The main objective of this study is to evaluate concordance of systolic arterial pressure pressure (in mmHg) measurement between invasive (arterial catheter) and non invasive technique (classical harm cuff)

    Measured: During neuroradiological procedure

  2. Diastolic arterial blood pressure (mmHg)

    The main objective of this study is to evaluate concordance of diastolic arterial pressure pressure (in mmHg) measurement between invasive (arterial catheter) and non invasive technique (classical harm cuff)

    Measured: During neuroradiological procedure

  3. Mean arterial blood pressure (mmHg)

    The main objective of this study is to evaluate concordance of mean arterial pressure pressure (in mmHg) measurement between invasive (arterial catheter) and non invasive technique (classical harm cuff)

    Measured: During neuroradiological procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Mar 2022
  2. Study start19 Mar 2022
  3. Primary completion8 Nov 2022
  4. Study completion8 Nov 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05283824
Sponsor's protocol ID
NEXFIN-NRI( 29BRC21.0268)
Acronym
NEXFIN-NRI
Status last verified
Jul 2023
First submitted
7 Feb 2022
Last updated
7 Jul 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: All collected data that underlie results in a publication

Publications

  • Kim SH, Lilot M, Sidhu KS, Rinehart J, Yu Z, Canales C, Cannesson M. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology. 2014 May;120(5):1080-97. doi: 10.1097/ALN.0000000000000226.

    PubMed 24637618
  • Mascha EJ, Yang D, Weiss S, Sessler DI. Intraoperative Mean Arterial Pressure Variability and 30-day Mortality in Patients Having Noncardiac Surgery. Anesthesiology. 2015 Jul;123(1):79-91. doi: 10.1097/ALN.0000000000000686.

    PubMed 25929547
  • Salmasi V, Maheshwari K, Yang D, Mascha EJ, Singh A, Sessler DI, Kurz A. Relationship between Intraoperative Hypotension, Defined by Either Reduction from Baseline or Absolute Thresholds, and Acute Kidney and Myocardial Injury after Noncardiac Surgery: A Retrospective Cohort Analysis. Anesthesiology. 2017 Jan;126(1):47-65. doi: 10.1097/ALN.0000000000001432.

    PubMed 27792044
  • Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002 Jun;6(3):199-204. doi: 10.1186/cc1489. Epub 2002 Apr 18.

    PubMed 12133178
  • Hofhuizen C, Lansdorp B, van der Hoeven JG, Scheffer GJ, Lemson J. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy. J Crit Care. 2014 Feb;29(1):161-5. doi: 10.1016/j.jcrc.2013.09.005.

    PubMed 24475498
  • Chen G, Meng L, Alexander B, Tran NP, Kain ZN, Cannesson M. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler. J Clin Anesth. 2012 Jun;24(4):275-83. doi: 10.1016/j.jclinane.2011.08.014.

    PubMed 22608581
  • Chapalain X, Morvan T, Gentric JC, Subileau A, Jacob C, Cadic A, Caillard A, Huet O. Continuous non-invasive vs. invasive arterial blood pressure monitoring during neuroradiological procedure: a comparative, prospective, monocentric, observational study. Perioper Med (Lond). 2024 Jul 22;13(1):77. doi: 10.1186/s13741-024-00442-3.

    PubMed 39034414

Questions about this trial

What is this clinical trial studying?

An observational study of Blood Pressure, run by University Hospital, Brest at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 7 Jul 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Systolic arterial blood pressure (mmHg) (time frame: During neuroradiological procedure). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05283824, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Jul 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in