LVADNCT06039176
Human/Machine Interface: What the HeartMate 3 ® Device Tells Us About the Future
An observational study of LVAD and Frailty, run by International Consortium of Circulatory Assist Clinicians at 7 sites in United States.
Trial summary
Durable left ventricular assist devices (dLVAD) have been increasingly utilized since the mid to late 1990s, with an uptick of utility starting in 2010 following expanded indications for therapy to not only include a bridge to transplantation strategy, but also for those individuals who suffer from advanced heart… Read more about this study
- Who is it for?
- Ages 18 to 100 years
- What is being tested?
- HeartMate 3 (R) left ventricular assist device
- Type of treatment
- Medical device
- How many people
- 150 participants
- Where
- 7 sitesUnited States
- Study dates
- 27 Oct 2023to 30 Dec 2026
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 100 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: The sample for this prospective study will derive of a goal of 15 individuals recruited at each of the 10 different dLVAD implanting centers, recognizing that not all sites may be able to recruit 15 participants. Participants will be selected through sequential convenience sampling, meaning each center will recruit participants in a sequential fashion in each of the centers based upon availability.
Who may be able to join
- 18 years of age or older
- Scheduled Heartmate 3 ® dLVAD implantation
Who cannot join
- <18 years of age
- Scheduled for dLVAD that is NOT a Heartmate 3 (R) device
Trial locations and contacts
7 sites in 1 country. Contact the study team or a site near you to ask about taking part.
7 sites in 1 country
United States7 sites, 4 recruiting
- Active, not recruiting
MUSC
Charleston, South Carolina, 29425
- Recruiting
University of Chicago
Chicago, Illinois, 60637
Krystina Chickerillo
- Recruiting
University of Florida
Gainesville, Florida, 32611
Sara Geiger
- Active, not recruiting
University of Kansas Medical Center
Kansas City, Kansas, 66103
- Recruiting
Mayo Clinic-Rochester
Rochester, Minnesota, 55902
Sarah Schettle, PA
- Active, not recruiting
University of Utah
Salt Lake City, Utah, 84112
- Recruiting
UCSF
San Francisco, California, 94143
Sylvie Baudart
About this study
Durable left ventricular assist devices (dLVAD) have been increasingly utilized since the mid to late 1990s, with an uptick of utility starting in 2010 following expanded indications for therapy to not only include a bridge to transplantation strategy, but also for those individuals who suffer from advanced heart failure (HF) and do not qualify for cardiac transplantation. Despite the decreasing size of the newest generation devices leading to a lessened occurrence of adverse events, bleeding and infection still remain a concern for clinicians, as well as a general lack of predictability towards adverse events in individuals with a dLVAD in place. There is a lack of description in the literature currently, regarding the interface between what the pump data provides and what is seen in clinical practice. There also is little known about the effects of what is provided in the pump data, in correlation to quality-of-life following dLVAD implantation.
Therefore, the purpose of this study is to prospectively analyze normal and abnormal pump data through pump operations such as suction events, low flow alarms as well as other adventitious alarms, PI events and power cable disconnects greater than 20 seconds, from the HeartMate 3 ® dLVAD in order to clinically correlate this data to quality of life, frailty and other various medical conditions and adverse events as defined by the Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs). This will be achieved through two aims: 1) Evaluate the effectiveness of dLVAD pump operations data on clinical practice application (quality of life, frailty and various medical conditions, and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke); and 2) Evaluate correlations and relationships of longitudinal normal and abnormal dLVAD pump operations data, to demographic and clinical variables. This study is the first study to evaluate HeartMate 3 ® dLVAD pump operations data over time for effectiveness in the clinical practice.
Read the detailed description
Specific Aims The prevalence of heart failure (HF), a chronic medical condition, continues to grow exponentially, affecting more than 26 million globally. There are more than 6.5 million in the United States alone with HF. Roughly 600,000 individuals suffer from end-stage HF, defined as advanced structural changes to the heart, significantly worsening HF symptoms despite medical therapy, and generally more than 50% 1-year mortality risk.There are limited treatment options once traditional guideline driven medical therapy fails in those advancing to end-stage HF. Limited treatment options at this point have included consideration of cardiac transplantation or implantation of a durable left ventricular assist device (dLVAD), or proceeding down the path of palliative care and hospice. One-year mortality risk without a dLVAD is nearing now 80%, as opposed to one-year survival with a dLVAD approaching 75-80%. Once a dLVAD is placed, concern continues of predicting adverse events. Multiple groups have utilized different strategies to predict the risk of bleeding, stroke and infection, yet not one strategy alone is all-encompassing of these three adverse events. Bleeding risk following dLVAD implantation ranges between 15-68%, while the risk of infection is estimated between 19-39%. The risk of stroke with dLVADs is as high as 10%. Prior to market removal, researchers utilizing the HeartWare ® (or HVAD) have analyzed waveform and pump data to predict or determine sequencing of adverse events. This study through machine learning, found that bleeding and right heart failure (RHF) were the most commonly found adverse events with the earliest onset, while infection and bleeding were the most common adverse events overall after three months on device. While additional pump data analyses exist for other centrifugal flow pumps, there is a significant gap in the literature where little information is known of how the HeartMate 3 ® dLVAD pump operations data (such as suction events, low flow alarms and other adventitious alarms, PI events and incidence of power cable disconnects greater than 20 seconds) interfaces with quality of life (QOL), frailty and other various medical conditions, as well as how additional pump data may predict future adverse events such as gastrointestinal bleeding (GIB), RHF, infection, hypertension, arrhythmias or stroke. Clinicians caring for individuals with a HeartMate 3 ® devices are not aware at this time how pump operations data correlates to the clinical component of care, thus demonstrating the importance of this study.
To address the gap of how the HeartMate 3 ® dLVAD pump data interfaces with clinical care, this prospective, multi-center trial will analyze the normal and abnormal pump operations data (such as suction events, low flow alarms and other adventitious alarms, PI events or incidence of power cable disconnects) from HeartMate 3 ® dLVADs for clinical correlations to QOL, severity of frailty, various medical conditions, and adverse events at ten different centers worldwide. Currently there are no mandatory guidelines for pump operations data downloads in the instructions-for-use manual, only recommendations from each individual company. Researchers have been challenged to think outside the box of what information has yet to be divulged from normal and abnormal pump operations in order to assist clinicians in better care as the evolution of smaller and smarter to devices occur. In this study, the investigators hypothesize the following: 1.) there will be correlations between abnormal hemodynamic pump operations (e.g. suction events, low flow alarms and other adventitious alarms, "PI" events, and power cable disconnects greater than 20 seconds), and worsening quality of life; 2.) worsening severity of frailty will demonstrate increased power cable disconnects and/or increased use of the power module "A/C" power, due to handling mistakes or less mobility; 3.) early stages of gastrointestinal bleeding will be seen with abnormal hemodynamic pump operations (such as suction events) 3-7 days prior to the actual event of being symptomatic; and 4.) patients with GIB or RHF will have lower PI values in comparison to those that do not have adverse events, when having comparable set speeds. In order to meet the objectives with the purpose of this study, two aims have been established:
Aim #1: Evaluate the effectiveness of HeartMate 3 ® dLVAD normal and abnormal pump operations data on clinical practice applications when utilizing downloadable pump data analyses at several time points following implantation: discharge from the intensive care unit (ICU), discharge from the hospital (minimum over a week post implant and +/- 3 days from discharge), 3-months post dLVAD, 6-months post dLVAD, and 12-months post dLVAD. Data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned Emergency Room (ER) visits related to equipment problems or any serious adverse event related ER visits. Clinical practice applications include: QOL, severity of frailty and other various medical conditions, and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke.
Aim #2: Evaluate correlations and relationships between longitudinal normal and abnormal dLVAD pump operations data, to demographic and clinical variables (e.g. age, gender, length of stay, Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs) score, co-morbidities, eyeball frailty test, laboratory values, EQ-5D and Visual Analog Scale, Mini-Cog ©, physical frailty measurements through 6-Minute Walk Test and Sit-to-Stand Chair rise test, anticoagulation strategies, cardiopulmonary bypass time, intubation to extubation time, temporary support prior to and following dLVAD implantation, concomitant surgeries, post-surgical complications, and echocardiography results).
Significance Individuals caring for HeartMate 3 ® dLVAD recipients oftentimes rely on industry interpretation of waveforms and pump data in urgent clinical situations. However, there may be limitations in how quick this information is provided to the clinicians to piece the puzzle together. There is limited pump operations data research directly available to the clinician to demonstrate the interface connection towards clinical practical applications, or relationships with other co-morbid conditions and adverse events as previously mentioned. With persistent adverse events in the dLVAD population, more information pertaining to the clinical situation is always helpful. There has only been data reported on the Heartware ® system with regards to real time data. For example, HeartWare ® log files and pump operations data have been analyzed to identify ingestion of pump thrombosis, while suggestions have begun to start using patient monitoring through the HeartMate 3 ® dLVAD system. To date, there is scarce literature to describe the HeartMate 3 ® dLVAD pump operations data within the clinical interface. More importantly, clinicians are not aware of added benefits from dLVADs unless shared from industry partners.
When a HeartMate 3 ® dLVAD patient presents with a problem or suspected adverse event, current practice and recommendations from industry is to download the log files and pump operations data, and submit directly to the Abbott ® team to further provide insight from industry of any potential problems occurring directly with the device. This download is quick and can be done by ventricular assist device (VAD) coordinators or other staff in the hospital or clinic, however the analysis results themselves can at times, take up to a few hours to learn mostly what is already being seen by the clinician performing the download. The Medical University of Vienna team has the ability to interpret routine and available downloadable pump operations data through file analyses when downloading files using the Abbott ® display screens or HeartMate Touch ® systems. This advancement from the Medical University of Vienna will provide additional analysis efforts in this study following pump operations data retrieval.
Despite attempts of medical care being guided towards prevention, health care often times resorts to reactionary care instead, by no fault of our own. If clinicians had the capability of predicting adverse events, what affects QOL and what may lessen the severity of frailty or other affects towards medical conditions based upon the downloadable pump operations data alone, the health care pendulum would swing back towards the efforts of prevention, lessening cost and improving overall QOL. There have been speculations of utilizing dLVADs as a means for patient monitoring, leading clinicians to consider recommendations of needing wireless transmission of real time dLVAD pump operations data at any point throughout the life of a dLVAD, including while at home, at routine care appointments and when things arise or symptoms occur. This would be a similar process in how an automated internal cardiac defibrillator patient sends in a manual transmission download for the clinician to further evaluate any rhythm disturbances. This is a major gap in the functional reporting of a dLVAD and can actually hinder the care provided by the clinician seeing the patient. This has led to the development of this study.
Previous reports have discussed analyzing pump data on the HeartWare ® device. This pump has now been removed from the market for implantation purposes, but this research paved the way for future needs of clinicians when it comes down to the care of a dLVAD patient. One thing learned through the recent SARS-CoV-19 pandemic is the benefit and utility of remote monitoring for ongoing patient care across the spectrum of healthcare, in order to assist in resource allocation. Clinicians caring for dLVAD patients need to further investigate predictive models and causal relationships of pump operations data to QOL, the severity of frailty, advancement of other medical conditions and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke. The study's primary end point is 12-month survival post-LVAD implantation stratified by percentage of abnormal pump data. Secondary end point is to evaluate correlations and relationships between normal and abnormal dLVAD pump data, to demographic and clinical variables, including longitudinal pump data analyses.
Preliminary Study Work Pilot work regarding HeartMate 3 ® dLVAD pump data analyses began in 2020, where retrospective data was compiled to begin understanding the effects of downloaded log files to adverse events. This pivotal start of research demonstrated there is utility in HeartMate 3 ® dLVAD log files to determine potential suction events leading to ischemic strokes. After further discussion between VAD coordinators across the globe, members of the International Consortium of Circulatory Assist Clinicians (ICCAC) society suggested to proceed with further investigation into what further log file interpretation is needed to provide assistance in clinical care.
This study does not involve any devices being attached to the driveline or other alterations to the pump or external components. This study is strictly looking at analyses of routinely available and "downloadable" log files at prospective time points. This grant moves the science forward in attempts to identify relationships between HeartMate 3 ® dLVAD pump operations data (both normal and abnormal) regarding QOL, severity of frailty, advancement of medical conditions and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke. Currently, standard of practice does not mandatorily dictate when pump data should be downloaded, with current recommendations being at all of the Intermacs follow-up appointments.
- Conditions
- LVAD, Frailty, GI Bleed, Right Heart Failure, Infections, Hypertension
- Being tested
- HeartMate 3 (R) left ventricular assist device
- Medical subject headings
- Frailty, Gastrointestinal Hemorrhage, Heart Failure, Infections, Hypertension, Arrhythmias, Cardiac, Stroke
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
HeartMate 3 (R) left ventricular assist deviceDevice
No direct intervention; this is prospective study analysis of pump data from the HeartMate 3 (R) left ventricular assist device with clinical correlation to a multitude of variables and conditions we see clinically
| Study group | Role | What they receive |
|---|---|---|
| Mayo Clinic | Obtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. Receives: Device: HeartMate 3 (R) left ventricular assist device | |
| University of Florida | Obtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. Receives: Device: HeartMate 3 (R) left ventricular assist device | |
| University of Utah | Obtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. Receives: Device: HeartMate 3 (R) left ventricular assist device | |
| University of California, San Francisco | Obtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. Receives: Device: HeartMate 3 (R) left ventricular assist device | |
| University of Chicago | Obtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. Receives: Device: HeartMate 3 (R) left ventricular assist device | |
| University of Kansas Medical System | Obtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. Receives: Device: HeartMate 3 (R) left ventricular assist device | |
| Medical University of South Carolina | Obtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. Receives: Device: HeartMate 3 (R) left ventricular assist device |
What is being measured
The primary outcome is the main question the study is designed to answer.
Survival
12-month survival post LVAD implantation stratified by percentage of abnormal pump data
Measured: 12-months
Secondary outcomes (1)
Variable Correlations
Evaluate correlations and relationships between LVAD pump data (Pump parameters-Speed, Flow, PI and power; along with suction events, low flow alarms and other adventitious alarms, "PI" events, and power cable disconnects greater than 20 seconds), to demographic and clinical variables (age, gender, race, marital status, device indication, blood type, type of cardiomyopathy, height, weight, intermacs profile score, co-morbidities, vital signs, swan ganz catheter values, LVAD number values, frailty test, labs, Quality of Life testing, Cognitive, Anticoagulation Strategies, Cardiopulmonary Bypass Time, length of stay, intubation to extubation time, concommittant surgeries at implant, Temporary Support prior to implantation or following implantation, Post-surgical complications, Echocardiography results), including longitudinal pump data analyses
Measured: 12-months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Sep 2023
- Study start27 Oct 2023
- Primary completion30 Dec 2026 (estimated)
- Study completion30 Dec 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (14)Papers the sponsor has linked to this study.
- Other trials for LVADStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 150 participants (estimated)
Sponsor and investigators
- Lead sponsor
- International Consortium of Circulatory Assist Clinicians
- Sponsor type
- University, hospital or other
- Collaborators
- Abbott, Medical University of Vienna, Mayo Clinic, University of Florida, University of Utah, University of Kansas Medical Center, Medical University of South Carolina, University of Chicago, University of California, San Francisco
- Responsible party
- Sponsor
- Investigators
- Sarah E Schroeder, PhD MSN RN, Principal investigator, International Consortium of Circulatory Assist Clinicians
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06039176
- Sponsor's protocol ID
- ICCAC
- Status last verified
- Dec 2025
- First submitted
- 8 Sep 2023
- Last updated
- 16 Dec 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Undecided: All individual centers will hold their own data specific to their participants. No individualized identified data will be shared with any center directly or with the funding company. With that being said, Abbott will receive de-identified data in the form of already analyzed data, after initial analyses are done, for their review.
Publications
Benjamin EJ, Muntner P, Alonso A, Bittencourt MS, Callaway CW, Carson AP, Chamberlain AM, Chang AR, Cheng S, Das SR, Delling FN, Djousse L, Elkind MSV, Ferguson JF, Fornage M, Jordan LC, Khan SS, Kissela BM, Knutson KL, Kwan TW, Lackland DT, Lewis TT, Lichtman JH, Longenecker CT, Loop MS, Lutsey PL, Martin SS, Matsushita K, Moran AE, Mussolino ME, O'Flaherty M, Pandey A, Perak AM, Rosamond WD, Roth GA, Sampson UKA, Satou GM, Schroeder EB, Shah SH, Spartano NL, Stokes A, Tirschwell DL, Tsao CW, Turakhia MP, VanWagner LB, Wilkins JT, Wong SS, Virani SS; American Heart Association Council on Epidemiology and Prevention Statistics Committee and Stroke Statistics Subcommittee. Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association. Circulation. 2019 Mar 5;139(10):e56-e528. doi: 10.1161/CIR.0000000000000659. No abstract available.
PubMed 30700139Shahim B, Kapelios CJ, Savarese G, Lund LH. Global Public Health Burden of Heart Failure: An Updated Review. Card Fail Rev. 2023 Jul 27;9:e11. doi: 10.15420/cfr.2023.05. eCollection 2023.
PubMed 37547123Friedrich EB, Bohm M. Management of end stage heart failure. Heart. 2007 May;93(5):626-31. doi: 10.1136/hrt.2006.098814. No abstract available.
PubMed 17435073Gosev I, Kiernan MS, Eckman P, Soleimani B, Kilic A, Uriel N, Rich JD, Katz JN, Cowger J, Lima B, McGurk S, Brisco-Bacik MA, Lee S, Joseph SM, Patel CB; Evolving Mechanical Support Research Group (EMERG) Investigators. Long-Term Survival in Patients Receiving a Continuous-Flow Left Ventricular Assist Device. Ann Thorac Surg. 2018 Mar;105(3):696-701. doi: 10.1016/j.athoracsur.2017.08.057. Epub 2017 Dec 2.
PubMed 29198630Mancini D, Colombo PC. Left Ventricular Assist Devices: A Rapidly Evolving Alternative to Transplant. J Am Coll Cardiol. 2015 Jun 16;65(23):2542-55. doi: 10.1016/j.jacc.2015.04.039.
PubMed 26065994Mehra MR, Goldstein DJ, Uriel N, Cleveland JC Jr, Yuzefpolskaya M, Salerno C, Walsh MN, Milano CA, Patel CB, Ewald GA, Itoh A, Dean D, Krishnamoorthy A, Cotts WG, Tatooles AJ, Jorde UP, Bruckner BA, Estep JD, Jeevanandam V, Sayer G, Horstmanshof D, Long JW, Gulati S, Skipper ER, O'Connell JB, Heatley G, Sood P, Naka Y; MOMENTUM 3 Investigators. Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure. N Engl J Med. 2018 Apr 12;378(15):1386-1395. doi: 10.1056/NEJMoa1800866. Epub 2018 Mar 11.
PubMed 29526139Milano CA, Rogers JG, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, Mokadam NA, Mahr C, Miller JS, Markham DW, Jeevanandam V, Uriel N, Aaronson KD, Vassiliades TA, Pagani FD; ENDURANCE Investigators. HVAD: The ENDURANCE Supplemental Trial. JACC Heart Fail. 2018 Sep;6(9):792-802. doi: 10.1016/j.jchf.2018.05.012. Epub 2018 Jul 11.
PubMed 30007559Birks EJ. Stopping LVAD Bleeding: A Piece of the Puzzle. Circ Res. 2017 Sep 29;121(8):902-904. doi: 10.1161/CIRCRESAHA.117.311759. No abstract available.
PubMed 28963184Zinoviev R, Lippincott CK, Keller SC, Gilotra NA. In Full Flow: Left Ventricular Assist Device Infections in the Modern Era. Open Forum Infect Dis. 2020 Apr 17;7(5):ofaa124. doi: 10.1093/ofid/ofaa124. eCollection 2020 May.
PubMed 32405511Cornwell WK 3rd, Ambardekar AV, Tran T, Pal JD, Cava L, Lawley J, Tarumi T, Cornwell CL, Aaronson K. Stroke Incidence and Impact of Continuous-Flow Left Ventricular Assist Devices on Cerebrovascular Physiology. Stroke. 2019 Feb;50(2):542-548. doi: 10.1161/STROKEAHA.118.022967. No abstract available.
PubMed 30602359Kilic A, Macickova J, Duan L, Movahedi F, Seese L, Zhang Y, Jacoski MV, Padman R. Machine Learning Approaches to Analyzing Adverse Events Following Durable LVAD Implantation. Ann Thorac Surg. 2021 Sep;112(3):770-777. doi: 10.1016/j.athoracsur.2020.09.040. Epub 2020 Nov 20.
PubMed 33221198Han JJ, Acker MA, Atluri P. Left Ventricular Assist Devices. Circulation. 2018 Dec 11;138(24):2841-2851. doi: 10.1161/CIRCULATIONAHA.118.035566.
PubMed 30565993Moscato F, Gross C, Maw M, Schloglhofer T, Granegger M, Zimpfer D, Schima H. The left ventricular assist device as a patient monitoring system. Ann Cardiothorac Surg. 2021 Mar;10(2):221-232. doi: 10.21037/acs-2020-cfmcs-218.
PubMed 33842216Watson AR, Wah R, Thamman R. The Value of Remote Monitoring for the COVID-19 Pandemic. Telemed J E Health. 2020 Sep;26(9):1110-1112. doi: 10.1089/tmj.2020.0134. Epub 2020 May 7.
PubMed 32384251
Study at a glance
From the registry record, last updated by the sponsor on 16 Dec 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Human/Machine Interface: What the HeartMate 3 ® Device Tells Us About the Future
- ClinicalTrials.gov ID
- NCT06039176
- Acronym / sponsor ID
- ICCAC
- Conditions
- LVAD, Frailty, GI Bleed, Right Heart Failure, Infections, Hypertension
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 150 participants (estimated)
- Lead sponsor
- International Consortium of Circulatory Assist CliniciansUniversity, hospital or other
- Collaborators
- Abbott, Medical University of Vienna, Mayo Clinic, University of Florida, University of Utah, University of Kansas Medical Center, Medical University of South Carolina, University of Chicago, University of California, San Francisco
- Study start
- 27 Oct 2023 (actual)
- Primary completion
- 30 Dec 2026 (estimated)
- Study completion
- 30 Dec 2026 (estimated)
- First posted
- 15 Sep 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Durable left ventricular assist devices (dLVAD) have been increasingly utilized since the mid to late 1990s, with an uptick of utility starting in 2010 following expanded indications for therapy to not only include a bridge to transplantation strategy, but also for those individuals who suffer from advanced heart failure (HF) and do not qualify for cardiac transplantation. Despite the decreasing size of the newest generation devices leading to a lessened occurrence of adverse events, bleeding and infection still remain a concern for clinicians, as well as a general lack of predictability towards adverse events in individuals with a dLVAD in place. There is a lack of description in the literature currently, regarding the interface between what the pump data provides and what is seen in clinical practice. There also is little known about the effects of what is provided in the pump data, in correlation to quality-of-life following dLVAD implantation.
Therefore, the purpose of this study is to prospectively analyze normal and abnormal pump data through pump operations such as suction events, low flow alarms as well as other adventitious alarms, PI events and power cable disconnects greater than 20 seconds, from the HeartMate 3 ® dLVAD in order to clinically correlate this data to quality of life, frailty and other various medical conditions and adverse events as defined by the Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs). This will be achieved through two aims: 1) Evaluate the effectiveness of dLVAD pump operations data on clinical practice application (quality of life, frailty and various medical conditions, and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke); and 2) Evaluate correlations and relationships of longitudinal normal and abnormal dLVAD pump operations data, to demographic and clinical variables. This study is the first study to evaluate HeartMate 3 ® dLVAD pump operations data over time for effectiveness in the clinical practice.
Detailed description
Specific Aims The prevalence of heart failure (HF), a chronic medical condition, continues to grow exponentially, affecting more than 26 million globally. There are more than 6.5 million in the United States alone with HF. Roughly 600,000 individuals suffer from end-stage HF, defined as advanced structural changes to the heart, significantly worsening HF symptoms despite medical therapy, and generally more than 50% 1-year mortality risk.There are limited treatment options once traditional guideline driven medical therapy fails in those advancing to end-stage HF. Limited treatment options at this point have included consideration of cardiac transplantation or implantation of a durable left ventricular assist device (dLVAD), or proceeding down the path of palliative care and hospice. One-year mortality risk without a dLVAD is nearing now 80%, as opposed to one-year survival with a dLVAD approaching 75-80%. Once a dLVAD is placed, concern continues of predicting adverse events. Multiple groups have utilized different strategies to predict the risk of bleeding, stroke and infection, yet not one strategy alone is all-encompassing of these three adverse events. Bleeding risk following dLVAD implantation ranges between 15-68%, while the risk of infection is estimated between 19-39%. The risk of stroke with dLVADs is as high as 10%. Prior to market removal, researchers utilizing the HeartWare ® (or HVAD) have analyzed waveform and pump data to predict or determine sequencing of adverse events. This study through machine learning, found that bleeding and right heart failure (RHF) were the most commonly found adverse events with the earliest onset, while infection and bleeding were the most common adverse events overall after three months on device. While additional pump data analyses exist for other centrifugal flow pumps, there is a significant gap in the literature where little information is known of how the HeartMate 3 ® dLVAD pump operations data (such as suction events, low flow alarms and other adventitious alarms, PI events and incidence of power cable disconnects greater than 20 seconds) interfaces with quality of life (QOL), frailty and other various medical conditions, as well as how additional pump data may predict future adverse events such as gastrointestinal bleeding (GIB), RHF, infection, hypertension, arrhythmias or stroke. Clinicians caring for individuals with a HeartMate 3 ® devices are not aware at this time how pump operations data correlates to the clinical component of care, thus demonstrating the importance of this study.
To address the gap of how the HeartMate 3 ® dLVAD pump data interfaces with clinical care, this prospective, multi-center trial will analyze the normal and abnormal pump operations data (such as suction events, low flow alarms and other adventitious alarms, PI events or incidence of power cable disconnects) from HeartMate 3 ® dLVADs for clinical correlations to QOL, severity of frailty, various medical conditions, and adverse events at ten different centers worldwide. Currently there are no mandatory guidelines for pump operations data downloads in the instructions-for-use manual, only recommendations from each individual company. Researchers have been challenged to think outside the box of what information has yet to be divulged from normal and abnormal pump operations in order to assist clinicians in better care as the evolution of smaller and smarter to devices occur. In this study, the investigators hypothesize the following: 1.) there will be correlations between abnormal hemodynamic pump operations (e.g. suction events, low flow alarms and other adventitious alarms, "PI" events, and power cable disconnects greater than 20 seconds), and worsening quality of life; 2.) worsening severity of frailty will demonstrate increased power cable disconnects and/or increased use of the power module "A/C" power, due to handling mistakes or less mobility; 3.) early stages of gastrointestinal bleeding will be seen with abnormal hemodynamic pump operations (such as suction events) 3-7 days prior to the actual event of being symptomatic; and 4.) patients with GIB or RHF will have lower PI values in comparison to those that do not have adverse events, when having comparable set speeds. In order to meet the objectives with the purpose of this study, two aims have been established:
Aim #1: Evaluate the effectiveness of HeartMate 3 ® dLVAD normal and abnormal pump operations data on clinical practice applications when utilizing downloadable pump data analyses at several time points following implantation: discharge from the intensive care unit (ICU), discharge from the hospital (minimum over a week post implant and +/- 3 days from discharge), 3-months post dLVAD, 6-months post dLVAD, and 12-months post dLVAD. Data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned Emergency Room (ER) visits related to equipment problems or any serious adverse event related ER visits. Clinical practice applications include: QOL, severity of frailty and other various medical conditions, and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke.
Aim #2: Evaluate correlations and relationships between longitudinal normal and abnormal dLVAD pump operations data, to demographic and clinical variables (e.g. age, gender, length of stay, Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs) score, co-morbidities, eyeball frailty test, laboratory values, EQ-5D and Visual Analog Scale, Mini-Cog ©, physical frailty measurements through 6-Minute Walk Test and Sit-to-Stand Chair rise test, anticoagulation strategies, cardiopulmonary bypass time, intubation to extubation time, temporary support prior to and following dLVAD implantation, concomitant surgeries, post-surgical complications, and echocardiography results).
Significance Individuals caring for HeartMate 3 ® dLVAD recipients oftentimes rely on industry interpretation of waveforms and pump data in urgent clinical situations. However, there may be limitations in how quick this information is provided to the clinicians to piece the puzzle together. There is limited pump operations data research directly available to the clinician to demonstrate the interface connection towards clinical practical applications, or relationships with other co-morbid conditions and adverse events as previously mentioned. With persistent adverse events in the dLVAD population, more information pertaining to the clinical situation is always helpful. There has only been data reported on the Heartware ® system with regards to real time data. For example, HeartWare ® log files and pump operations data have been analyzed to identify ingestion of pump thrombosis, while suggestions have begun to start using patient monitoring through the HeartMate 3 ® dLVAD system. To date, there is scarce literature to describe the HeartMate 3 ® dLVAD pump operations data within the clinical interface. More importantly, clinicians are not aware of added benefits from dLVADs unless shared from industry partners.
When a HeartMate 3 ® dLVAD patient presents with a problem or suspected adverse event, current practice and recommendations from industry is to download the log files and pump operations data, and submit directly to the Abbott ® team to further provide insight from industry of any potential problems occurring directly with the device. This download is quick and can be done by ventricular assist device (VAD) coordinators or other staff in the hospital or clinic, however the analysis results themselves can at times, take up to a few hours to learn mostly what is already being seen by the clinician performing the download. The Medical University of Vienna team has the ability to interpret routine and available downloadable pump operations data through file analyses when downloading files using the Abbott ® display screens or HeartMate Touch ® systems. This advancement from the Medical University of Vienna will provide additional analysis efforts in this study following pump operations data retrieval.
Despite attempts of medical care being guided towards prevention, health care often times resorts to reactionary care instead, by no fault of our own. If clinicians had the capability of predicting adverse events, what affects QOL and what may lessen the severity of frailty or other affects towards medical conditions based upon the downloadable pump operations data alone, the health care pendulum would swing back towards the efforts of prevention, lessening cost and improving overall QOL. There have been speculations of utilizing dLVADs as a means for patient monitoring, leading clinicians to consider recommendations of needing wireless transmission of real time dLVAD pump operations data at any point throughout the life of a dLVAD, including while at home, at routine care appointments and when things arise or symptoms occur. This would be a similar process in how an automated internal cardiac defibrillator patient sends in a manual transmission download for the clinician to further evaluate any rhythm disturbances. This is a major gap in the functional reporting of a dLVAD and can actually hinder the care provided by the clinician seeing the patient. This has led to the development of this study.
Previous reports have discussed analyzing pump data on the HeartWare ® device. This pump has now been removed from the market for implantation purposes, but this research paved the way for future needs of clinicians when it comes down to the care of a dLVAD patient. One thing learned through the recent SARS-CoV-19 pandemic is the benefit and utility of remote monitoring for ongoing patient care across the spectrum of healthcare, in order to assist in resource allocation. Clinicians caring for dLVAD patients need to further investigate predictive models and causal relationships of pump operations data to QOL, the severity of frailty, advancement of other medical conditions and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke. The study's primary end point is 12-month survival post-LVAD implantation stratified by percentage of abnormal pump data. Secondary end point is to evaluate correlations and relationships between normal and abnormal dLVAD pump data, to demographic and clinical variables, including longitudinal pump data analyses.
Preliminary Study Work Pilot work regarding HeartMate 3 ® dLVAD pump data analyses began in 2020, where retrospective data was compiled to begin understanding the effects of downloaded log files to adverse events. This pivotal start of research demonstrated there is utility in HeartMate 3 ® dLVAD log files to determine potential suction events leading to ischemic strokes. After further discussion between VAD coordinators across the globe, members of the International Consortium of Circulatory Assist Clinicians (ICCAC) society suggested to proceed with further investigation into what further log file interpretation is needed to provide assistance in clinical care.
This study does not involve any devices being attached to the driveline or other alterations to the pump or external components. This study is strictly looking at analyses of routinely available and "downloadable" log files at prospective time points. This grant moves the science forward in attempts to identify relationships between HeartMate 3 ® dLVAD pump operations data (both normal and abnormal) regarding QOL, severity of frailty, advancement of medical conditions and adverse events such as GIB, RHF, infection, hypertension, arrhythmias and stroke. Currently, standard of practice does not mandatorily dictate when pump data should be downloaded, with current recommendations being at all of the Intermacs follow-up appointments.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 7
| Arm | Type | Receives |
|---|---|---|
| Mayo Clinic | – | Device: HeartMate 3 (R) left ventricular assist deviceObtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. |
| University of Florida | – | Device: HeartMate 3 (R) left ventricular assist deviceObtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. |
| University of Utah | – | Device: HeartMate 3 (R) left ventricular assist deviceObtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. |
| University of California, San Francisco | – | Device: HeartMate 3 (R) left ventricular assist deviceObtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. |
| University of Chicago | – | Device: HeartMate 3 (R) left ventricular assist deviceObtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. |
| University of Kansas Medical System | – | Device: HeartMate 3 (R) left ventricular assist deviceObtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. |
| Medical University of South Carolina | – | Device: HeartMate 3 (R) left ventricular assist deviceObtain demographic and clinical data prior to and following implantation of a HeartMate 3 ® device. HeartMate 3® downloaded pump operations data will be obtained at the following scheduled intervals: discharge from the ICU, at the time of discharge from the hospital (or ± 3 days from discharge), 3-months post-implant, 6-months post-implant, and lastly at 12-months post-implant. Downloadable pump operations data will include evaluation of suction events, low flow and other adventitious alarms, PI events and incidence of power cable disconnects beyond 20 seconds. The previously mentioned data will also be collected during any unplanned office visits, any admission regardless of the reason, unplanned ER visits related to equipment problems or any serious adverse event-related ER visits. |
Who may qualify
- Ages
- 18 to 100 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- The sample for this prospective study will derive of a goal of 15 individuals recruited at each of the 10 different dLVAD implanting centers, recognizing that not all sites may be able to recruit 15 participants. Participants will be selected through sequential convenience sampling, meaning each center will recruit participants in a sequential fashion in each of the centers based upon availability.
Key inclusion criteria (2 listed)
- 18 years of age or older
- Scheduled Heartmate 3 ® dLVAD implantation
Key exclusion criteria (2 listed)
- <18 years of age
- Scheduled for dLVAD that is NOT a Heartmate 3 (R) device
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| HeartMate 3 (R) left ventricular assist deviceNo direct intervention; this is prospective study analysis of pump data from the HeartMate 3 (R) left ventricular assist device with clinical correlation to a multitude of variables and conditions we see clinically | Device | Mayo Clinic, Medical University of South Carolina, University of California, San Francisco, University of Chicago, University of Florida, University of Kansas Medical System, University of Utah |
Primary outcome
Survival
Time frame: 12-months
12-month survival post LVAD implantation stratified by percentage of abnormal pump data
1 secondary outcome
Variable Correlations
Time frame: 12-months
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 16 Dec 2025.
- Results publication: PubMed 30700139Benjamin EJ, Muntner P, Alonso A, Bittencourt MS, Callaway CW, Carson AP, Chamberlain AM, Chang AR, Cheng S, Das SR, Delling FN, Djousse L, Elkind MSV, Ferguson JF, Fornage M, Jordan LC, Khan SS, Kissela BM, Knutson KL, Kwan TW, Lackland DT, Lewis TT, Lichtman JH, Longenecker CT, Loop MS, Lutsey PL, Martin SS, Matsushita K, Moran AE, Mussolino ME, O'Flaherty M, Pandey A, Perak AM, Rosamond WD, Roth GA, Sampson UKA, Satou GM, Schroeder EB, Shah SH, Spartano NL, Stokes A, Tirschwell DL, Tsao CW, Turakhia MP, VanWagner LB, Wilkins JT, Wong SS, Virani SS; American Heart Association Council on Epidemiology and Prevention Statistics Committee and Stroke Statistics Subcommittee. Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association. Circulation. 2019 Mar 5;139(10):e56-e528. doi: 10.1161/CIR.0000000000000659. No abstract available.
- Results publication: PubMed 37547123Shahim B, Kapelios CJ, Savarese G, Lund LH. Global Public Health Burden of Heart Failure: An Updated Review. Card Fail Rev. 2023 Jul 27;9:e11. doi: 10.15420/cfr.2023.05. eCollection 2023.
- Results publication: PubMed 17435073Friedrich EB, Bohm M. Management of end stage heart failure. Heart. 2007 May;93(5):626-31. doi: 10.1136/hrt.2006.098814. No abstract available.
- Results publication: PubMed 29198630Gosev I, Kiernan MS, Eckman P, Soleimani B, Kilic A, Uriel N, Rich JD, Katz JN, Cowger J, Lima B, McGurk S, Brisco-Bacik MA, Lee S, Joseph SM, Patel CB; Evolving Mechanical Support Research Group (EMERG) Investigators. Long-Term Survival in Patients Receiving a Continuous-Flow Left Ventricular Assist Device. Ann Thorac Surg. 2018 Mar;105(3):696-701. doi: 10.1016/j.athoracsur.2017.08.057. Epub 2017 Dec 2.
- Results publication: PubMed 26065994Mancini D, Colombo PC. Left Ventricular Assist Devices: A Rapidly Evolving Alternative to Transplant. J Am Coll Cardiol. 2015 Jun 16;65(23):2542-55. doi: 10.1016/j.jacc.2015.04.039.
- Results publication: PubMed 29526139Mehra MR, Goldstein DJ, Uriel N, Cleveland JC Jr, Yuzefpolskaya M, Salerno C, Walsh MN, Milano CA, Patel CB, Ewald GA, Itoh A, Dean D, Krishnamoorthy A, Cotts WG, Tatooles AJ, Jorde UP, Bruckner BA, Estep JD, Jeevanandam V, Sayer G, Horstmanshof D, Long JW, Gulati S, Skipper ER, O'Connell JB, Heatley G, Sood P, Naka Y; MOMENTUM 3 Investigators. Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure. N Engl J Med. 2018 Apr 12;378(15):1386-1395. doi: 10.1056/NEJMoa1800866. Epub 2018 Mar 11.
- Results publication: PubMed 30007559Milano CA, Rogers JG, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, Mokadam NA, Mahr C, Miller JS, Markham DW, Jeevanandam V, Uriel N, Aaronson KD, Vassiliades TA, Pagani FD; ENDURANCE Investigators. HVAD: The ENDURANCE Supplemental Trial. JACC Heart Fail. 2018 Sep;6(9):792-802. doi: 10.1016/j.jchf.2018.05.012. Epub 2018 Jul 11.
- Results publication: PubMed 28963184Birks EJ. Stopping LVAD Bleeding: A Piece of the Puzzle. Circ Res. 2017 Sep 29;121(8):902-904. doi: 10.1161/CIRCRESAHA.117.311759. No abstract available.
- Results publication: PubMed 32405511Zinoviev R, Lippincott CK, Keller SC, Gilotra NA. In Full Flow: Left Ventricular Assist Device Infections in the Modern Era. Open Forum Infect Dis. 2020 Apr 17;7(5):ofaa124. doi: 10.1093/ofid/ofaa124. eCollection 2020 May.
- Results publication: PubMed 30602359Cornwell WK 3rd, Ambardekar AV, Tran T, Pal JD, Cava L, Lawley J, Tarumi T, Cornwell CL, Aaronson K. Stroke Incidence and Impact of Continuous-Flow Left Ventricular Assist Devices on Cerebrovascular Physiology. Stroke. 2019 Feb;50(2):542-548. doi: 10.1161/STROKEAHA.118.022967. No abstract available.
- Results publication: PubMed 33221198Kilic A, Macickova J, Duan L, Movahedi F, Seese L, Zhang Y, Jacoski MV, Padman R. Machine Learning Approaches to Analyzing Adverse Events Following Durable LVAD Implantation. Ann Thorac Surg. 2021 Sep;112(3):770-777. doi: 10.1016/j.athoracsur.2020.09.040. Epub 2020 Nov 20.
- Results publication: PubMed 30565993Han JJ, Acker MA, Atluri P. Left Ventricular Assist Devices. Circulation. 2018 Dec 11;138(24):2841-2851. doi: 10.1161/CIRCULATIONAHA.118.035566.
- AHA: Advanced Heart FailureLink provided by the sponsor.
- G\*Power Statistical Power Analyses for Mac and WindowLink provided by the sponsor.
- Individual participant dataSharing planned: Undecided. All individual centers will hold their own data specific to their participants. No individualized identified data will be shared with any center directly or with the funding company. With that being said, Abbott will receive de-identified data in the form of already analyzed data, after initial analyses are done, for their review.
Related trials for LVAD
Active, not recruiting
JOURNEY LVAD: JOURNEY Left Ventricular Assist Device
Aortic Valve Regurgitation, Aortic Valve Disease Mixed
Active, not recruiting
The JenaValve ALIGN-AR LVAD Registry
Aortic Regurgitation, Aortic Valve Insufficiency
RecruitingObservational study
Cardiac REhabilitation COhort at the Medicine Campus DaVos to invEstigate Recovery
Cardiac Rehabilitation, Heart Failure
RecruitingPhase 1/2
A Study of Metformin to Improve Cardiac Function After LVAD Implantation
Heart Failure, Left Ventricular Assist Device
Not yet recruitingPhase 3
SWITCH: Apixaban vs Vitamin K in HM3
LVAD (Left Ventricular Assist Device) Thrombosis, Heart Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Sarah E Schroeder, PhD MSN RN principal investigator
International Consortium of Circulatory Assist Clinicians
7 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of LVAD and Frailty, run by International Consortium of Circulatory Assist Clinicians at 7 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 16 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 7 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Sarah E Schroeder, PhD MSN RN (402-937-3595, sarah.schroeder@vadcoordinator.org), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Survival (time frame: 12-months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06039176, which also lists 14 linked publications.