AzTrials
AzTrials

MyopiaSRMRNCT06059521

Software Refraction With Mobilerone Versus Retinoscopy

A study testing Software refraction with Eye Test Technology in a mobilerone and Retinoscopy in people with Myopia and Myopia, Moderate, run by Beijing Airdoc Technology Co., Ltd. at 3 sites in China.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

Software refraction in the mobilerone for myopia and astigmatism is a novel medical device for myopia adults and elder children with or without astigmatism. And the investigators would like to test its accuracy and efficacy as well as safety. Read more about this study

Who is it for?
Ages 10 to 46 yearsHealthy volunteers can take part
Conditions the study is for
Myopia, Myopia, Moderate, Astigmatism
What is being tested?
Software refraction with Eye Test Technology in a mobilerone and Retinoscopy
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
120 participants
Where
3 sitesChina
Study dates
15 Jul 2023to 30 Dec 2030
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 10 to 46 years
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult

Who may be able to join

  • • subject with ametropia on each eye ≤-12.00D
  • subject with best corrected visual acuity ≥ 20/25, no amblyopia
  • subject with normal transparency of eyes
  • subject with a healthy fundus that does not reveal major abnormalities that may affect vision due to the fluctuate situations
  • subject able to cooperate with the screen and the operator
  • subject without heavy drug treatment that may affect vision as synthetic antimalarials, corticosteroids
Show all 10Show fewer
  • non-diabetic subject
  • non nystagmus subject
  • non-strabismus subject
  • subject who has not had eye surgery less than 1 year old

Who cannot join

  • • subject with a topography showing an anomaly (keratoconus type or other)
  • subject with hyperopia or presbyopia
  • subject with mild myopia ≥ -1.00D
  • subject who cannot speak with the operator including those staff of local optometrists or ophthalmologists

Trial locations and contacts

3 sites in 1 country. Contact the study team or a site near you to ask about taking part.

China3 sites, 3 recruiting
  • Airdoc MPC Opthalmology Clinics

    Beijing, Beijing Municipality, 100089

    David, OD, +8618510386815, davidcoveney69@gmail.com

    Not yet recruiting
  • Jenny QIU

    Beijing, Beijing Municipality, 100089

    Jenny QIU, MD, +8618510386815, qiukaikai0620@airdoc.com

    Recruiting
  • Qiu Jenny

    Beijing, Haidian District, 100089

    QIU JENNY, MD, +8618510386815, qiukaikai0620@airdoc.com

    Recruiting

Other trials in China

About this study

Official title: Randomized Controlled Study on Subjective Refraction by Software Eye Test Technology Versus Retinoscopy

Software refraction in the mobilerone for myopia and astigmatism is a novel medical device for myopia adults and elder children with or without astigmatism. And the investigators would like to test its accuracy and efficacy as well as safety.

Read the detailed description

It's a software installed in a mobilerone with subjective guide on screen for testing myopic refractive error with or without astigmatism for adults or elder children. The investigators would like to compare its refraction results with retinoscopy.

Being tested
Software refraction with Eye Test Technology in a mobilerone, Retinoscopy
Keywords
software, refraction, subjective refraction, mobilerone, myopia, astigmatism
Medical subject headings
Myopia, Lymphoma, Follicular, Astigmatism

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Software refraction with Eye Test Technology in a mobileroneDevice

    Also called Online refraction or App refraction with Eye Test Technology

    Refraction is done by software App by a mobilerone software installed.

  • RetinoscopyDevice

    Also called Refraction by retinoscopy

    Retinoscopy is an objective refraction method with retinoscope.

Study groups in NCT06059521
Study groupRoleWhat they receive
Software RefractionExperimentalRefraction is done by software with subjective refraction through a mobilerone.
Receives: Device: Software refraction with Eye Test Technology in a mobilerone
Refraction by retinoscopyActive comparatorRefraction is done objectively by retinoscopy.
Receives: Device: Retinoscopy

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Spherical Equivalence(D)

    Spherical is myopic equivalence with total spherical plus half the cylinder diopter.

    Measured: 1-day and within 2 weeks

  2. Astigmatism Power(D)

    Cylinder value of each total astigmatism power

    Measured: 1-day and within 2 weeks

  3. Astigmatism axial

    Cylinder axis of astigmatism

    Measured: 1-day and within 2 weeks

  4. pupil distance (mm)

    pupil distance measurement with software or autorefractor

    Measured: 1-day and within 2 weeks

Secondary outcomes (1)
  1. Efficacy of test time (minutes)

    How long for each test

    Measured: 1-day and within 2 eeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Sep 2023
  2. Study start15 Jul 2023
  3. Primary completion30 Dec 2025 (estimated)
  4. Study completion30 Dec 2030 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
120 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06059521
Sponsor's protocol ID
AirdocSoftwareEyeTest
Acronym
SRMR
Status last verified
Sep 2023
First submitted
24 Jul 2023
Last updated
28 Sep 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Software refraction with Eye Test Technology in a mobilerone and Retinoscopy in people with Myopia and Myopia, Moderate, run by Beijing Airdoc Technology Co., Ltd. at 3 sites in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 10 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 28 Sep 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Each site lists its own contact: choose the nearest one under Trial locations. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Spherical Equivalence(D) (time frame: 1-day and within 2 weeks). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Sep 2023.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in