AzTrials
AzTrials

Bilateral Vestibular HypofunctionNCT06500975

Long Term Outcomes After Vestibular Implantation

A study testing Labyrinth Devices MVI™ Multichannel Vestibular Implant System in people with Bilateral Vestibular Hypofunction and Bilateral Vestibular Deficiency, run by Johns Hopkins University at 1 site in United States.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

Although cochlear implants can restore hearing to individuals who have lost cochlear hair cell function, there is no widely available, adequately effective treatment for individuals suffering chronic imbalance, postural instability and unsteady vision due to bilateral vestibular hypofunction. Read more about this study

Who is it for?
Ages 22 to 90 years
What is being tested?
Labyrinth Devices MVI™ Multichannel Vestibular Implant System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
32 participants
Where
1 siteUnited States
Study dates
1 Dec 2024to Dec 2029
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 22 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adults older than 22 years old who
  • have previously been enrolled in Johns Hopkins University Institutional Review Board protocol NA_00051349, IRB00335294 or IRB00346924 and
  • have previously been implanted with a vestibular implant under FDA IDE G150198

Who cannot join

None listed.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Charles C Della Santina, MDPhD contact

410-502-8047

cds@jhmi.edu

United States1 site, 1 recruiting
  • Johns Hopkins School of Medicine

    Baltimore, Maryland, 21287

    Lauren N Trainer, BS, 410-502-5129, vestibularimplant@jhmi.edu

    Charles C Della Santina, MDPhD, 410-502-8047, vestibularimplant@jhmi.edu

    Recruiting

Other trials in United States

About this study

Although cochlear implants can restore hearing to individuals who have lost cochlear hair cell function, there is no widely available, adequately effective treatment for individuals suffering chronic imbalance, postural instability and unsteady vision due to bilateral vestibular hypofunction. Prior research focused on ototoxic cases has demonstrated that electrical stimulation of the vestibular nerve via a chronically implanted multichannel vestibular implant can partially restore vestibular reflexes that normally maintain steady posture and vision; improve performance on objective measures of postural stability and gait; and improve patient-reported disability and health-related quality of life. This single-arm open-label study extends that research to evaluate outcomes for up to 8 individuals with non-ototoxic bilateral vestibular hypofunction, yielding a total of fifteen adults (age 22-90 years at time of enrollment) divided as equally as possible between ototoxic and non-ototoxic cases.

Read the detailed description

There is no widely available, adequately effective treatment for individuals suffering chronic imbalance, postural instability and unsteady vision due to loss of semicircular canal function despite vestibular rehabilitation exercises. The experience of 15 adults with bilateral vestibular hypofunction who underwent unilateral surgical placement of a vestibular implant and have received continuously motion-modulated electrical stimulation of the vestibular nerve for >6 months revealed vestibular implantation (VI) and motion-modulated stimulation can partially restore vestibular sensation and reflexes that normally maintain steady posture and vision. This study will examine long-term outcomes after vestibular implantation. Within constraints on power and/or minimum detectable effect size due to limits on the number of study participants permitted under IDE G150198, the study will test the following hypotheses regarding unilateral vestibular implantation, activation and long-term (≥3 years) continuous/daily use:

  1. It is safe, as determined by incidence of serious unanticipated adverse device-related events and as further quantified by proportions of:
  2. implanted ears with preservation of 4-frequency pure tone average for 0.5,1,2,4 kHz air-conducted audiometric detection thresholds ≤ 50 decibel (dB) HL and ear-specific speech discrimination ≥50% (consistent with Class A or B per American Academy of Otolaryngology-Head and Neck Surgery 1995 guidelines 13 ) or ≤ 30 dB change from preoperative baseline (if preoperative baseline is ≥20 dBHL) and ear-specific speech discrimination ≤30% worse than preoperative baseline (if preoperative baseline is ≤80%)
  3. participants with preservation of useful sound-field hearing by the above criteria, and
  4. implanted ears with preservation of otolith endorgan function, if present pre-operatively
  5. It is tolerable, as quantified by duration of compliance with use.
  6. It is efficacious, as defined by nonzero improvement with respect to preoperative baseline gait stability as quantified by Dynamic Gait Index (DGI) and vestibulo-ocular reflex gain during passive head impulse rotation (VHITG) .
Being tested
Labyrinth Devices MVI™ Multichannel Vestibular Implant System
Keywords
Vestibular, Implant, Prosthesis, Labyrinth, Ototoxicity, Gentamicin, Oscillopsia, Disequilibrium, Dizziness, Vestibulopathy, Inner Ear
Medical subject headings
Bilateral Vestibulopathy, Vestibular Diseases, Sensation Disorders, Labyrinth Diseases, Ototoxicity, Dysequilibrium syndrome, Dizziness

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Labyrinth Devices MVI™ Multichannel Vestibular Implant SystemDevice

    Also called Motion-modulated stimulation delivered by a vestibular implant already implanted under a prior study protocol

    Continuously motion-modulated stimulation delivered by a vestibular implant already implanted under a prior study protocol (Labyrinth Devices MVI™ Multichannel Vestibular Implant System)

Study groups in NCT06500975
Study groupRoleWhat they receive
Vestibular ImplantExperimentalUp to 32 participants will undergo implantation, activation and deactivation of a Labyrinth Devices MVI™ Multichannel Vestibular Implant System (MVI)
Receives: Device: Labyrinth Devices MVI™ Multichannel Vestibular Implant System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. PM1.1: Dynamic Gait Index (DGI)18 during motion-modulated implant stimulation at 4 years post-implantation, relative to pre-operative baseline, aggregated across all implant users.

    DGI comprises 8 gait tasks scored by an examiner: walking on a level surface, changing gait speed, walking during horizontal head turns, walking during vertical head turns, pivoting, stepping over an obstacle, stepping around obstacles, and waling up and down stairs. Each task is scored (0-3 points, 3 is best). Raw DGI score is the sum of the eight subtest scores and ranges from 0 to 24, with higher scores meaning better outcome and minimally important difference 3.2 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  2. PM1.2: Gain (VHITG) of the vestibulo-ocular reflex (VOR), as measured using the video head impulse test (vHIT)

    During video head impulse testing (vHIT), rotational eye and head movement are measured by a goggle-mounted camera and motion sensor during brief, fast ~10 degree head rotations about the axis of a semicircular canal being tested. Performance is quantified by vestibulo-ocular reflex (VOR) gain, which a ratio of eye movement to head movement (in this case the integral of eye velocity relative to the head and the additive inverse of the integral of head velocity, respectively). VHITG, the average vHIT VOR gain for each of the three semicircular canals of the implanted ear, typically ranges from 0 to 1, with higher numbers indicating better performance.

    Measured: 4 years post-implantation up to 5 years post-enrollment

Secondary outcomes (35)
  1. EM1.1: Vestibular Implant Composite Outcome (VICO) score

    Vestibular Implant Composite Outcome (VICO) score incorporates changes in vestibulo-ocular reflex gain during video head impulse testing, postural stability, gait, dizziness handicap, and health-related quality of life at 4 years post-implantation, relative to pre-operative baseline. VICO (t=6months post-op) score is the sum of changes, from preoperative baseline to 4 years post-implantation, in vestibulo-ocular reflex gain during passive head impulse rotation (VHITG); postural stability as quantified by the Bruininks-Oseretsky Test of Motor Proficiency, 2nd Edition Balance Subtest 5 (BOT); gait stability as quantified by Dynamic Gait Index (DGI); Dizziness Handicap Inventory (DHI); and SF6D health utility (SF6DU); with each component's contribution scaled to the corresponding test's minimally important difference (MID). Score 0-100, higher scores indicate better outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  2. EM1.2: Bruininks-Oseretsky Test of Motor Proficiency 2nd Edition Balance Subtest 5 (BOT) score.

    BOT comprises 9 postural tasks scored by an examiner: standing with both feet on a line, standing on one leg, tandem walking, walking on a line with eyes open and eyes closed, and standing on a balance beam. Each task is performed twice and scored (0-4 points, 4 is best). The BOT score is the sum of the best scores for each task. It ranges from 0 to 36 points, with higher scores meaning better outcome and minimally important difference 4.5 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  3. EM1.3: Dizziness Handicap Inventory (DHI)

    Dizziness Handicap Inventory (DHI) is a 25-question survey designed to quantify self-rated disability due to dizziness and unsteadiness, with scores ranging from 0 (least disabled, best outcome) to 100 (worst outcome). The minimally important difference is 18 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  4. EM1.4: SF6D utility (SF6DU) score

    SF6DU is a unitless health utility score computed from patient-reported replies to the SF6 health-related quality of life survey and ranging from 0 to 1, with higher scores meaning better outcome and minimally important difference 0.03 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  5. EM2.1: Vestibular Implant Composite Outcome (VICO) score

    Vestibular Implant Composite Outcome (VICO) score incorporates changes in vestibulo-ocular reflex gain during video head impulse testing, postural stability, gait, dizziness handicap, and health-related quality of life at 4 years post-implantation, relative to pre-operative baseline. VICO (t=6months post-op) score is the sum of changes, from preoperative baseline to 4 years post-implantation, in vestibulo-ocular reflex gain during passive head impulse rotation (VHITG); postural stability as quantified by the Bruininks-Oseretsky Test of Motor Proficiency, 2nd Edition Balance Subtest 5 (BOT); gait stability as quantified by Dynamic Gait Index (DGI); Dizziness Handicap Inventory (DHI); and SF6D health utility (SF6DU); with each component's contribution scaled to the corresponding test's minimally important difference (MID). Score 0-100, higher scores indicate better outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  6. EM2.2: Bruininks-Oseretsky Test of Motor Proficiency 2nd Edition Balance Subtest 5 (BOT)

    BOT includes 9 postural tasks scored by an examiner: standing with both feet on a line, standing on one leg, tandem walking, walking on a line with eyes open and eyes closed, and standing on a balance beam. Each task is performed twice and scored (0-4 points). The BOT score is the sum of the best scores for each task. It ranges from 0 to 36 points, with higher scores meaning better outcome and minimally important difference 4.5 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  7. EM2.3: Dizziness Handicap Inventory (DHI)

    Dizziness Handicap Inventory (DHI) is a 25-question survey designed to quantify self-rated disability due to dizziness and unsteadiness, with scores ranging from 0 (least disabled, best outcome) to 100 (worst outcome). The minimally important difference is 18 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  8. EM2.4: SF6D utility (SF6DU) score

    SF6DU is a unitless health utility score computed from patient-reported replies to the SF6 health-related quality of life survey and ranging from 0 to 1, with higher scores meaning better outcome and minimally important difference 0.03 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  9. EM2.5: Dynamic Gait Index (DGI)

    DGI comprises 8 gait tasks scored by an examiner: walking on a level surface, changing gait speed, walking during horizontal head turns, walking during vertical head turns, pivoting, stepping over an obstacle, stepping around obstacles, and waling up and down stairs. Each task is scored (0-3 points, 3 is best). Raw DGI score is the sum of the eight subtest scores and ranges from 0 to 24, with higher scores meaning better outcome and minimally important difference 3.2 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  10. EM2.6: Gain (VHITG) of the vestibulo-ocular reflex (VOR), as measured using the video head impulse test (vHIT) and averaged for the three implanted semicircular canals

    During video head impulse testing (vHIT), rotational eye and head movement are measured by a goggle-mounted camera and motion sensor during brief, fast ~10 degree head rotations about the axis of a semicircular canal being tested. Performance is quantified by vestibulo-ocular reflex (VOR) gain, which a ratio of eye movement to head movement (in this case the integral of eye velocity relative to the head and the additive inverse of the integral of head velocity, respectively). VHITG, the average vHIT VOR gain for each of the three semicircular canals of the implanted ear, typically ranges from 0 to 1, with higher numbers indicating better performance.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  11. EM3.1: Vestibular Implant Composite Outcome (VICO) score at 4 years post-implantation, relative to pre-operative baseline, for the subgroup of participants who have ototoxic adult-onset BVH.

    Vestibular Implant Composite Outcome (VICO) score incorporates changes in vestibulo-ocular reflex gain during video head impulse testing, postural stability, gait, dizziness handicap, and health-related quality of life at 4 years post-implantation, relative to pre-operative baseline. VICO (t=6months post-op) score is the sum of changes, from preoperative baseline to 4 years post-implantation, in vestibulo-ocular reflex gain during passive head impulse rotation (VHITG); postural stability as quantified by the Bruininks-Oseretsky Test of Motor Proficiency, 2nd Edition Balance Subtest 5 (BOT); gait stability as quantified by Dynamic Gait Index (DGI); Dizziness Handicap Inventory (DHI); and SF6D health utility (SF6DU); with each component's contribution scaled to the corresponding test's minimally important difference (MID). Score 0-100, higher scores indicate better outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  12. EM3.2: Bruininks-Oseretsky Test of Motor Proficiency 2nd Edition Balance Subtest 5 (BOT) score 4 years post-implantation, relative to pre-operative baseline, for the subgroup of participants who have ototoxic adult-onset BVH.

    BOT includes 9 postural tasks scored by an examiner: standing with both feet on a line, standing on one leg, tandem walking, walking on a line with eyes open and eyes closed, and standing on a balance beam. Each task is performed twice and scored (0-4 points). The BOT score is the sum of the best scores for each task. It ranges from 0 to 36 points, with higher scores meaning better outcome and minimally important difference 4.5 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  13. EM3.3: Dizziness Handicap Inventory (DHI) score at 4 years post-implantation, relative to pre-operative baseline, for the subgroup of participants who have ototoxic adult-onset BVH.

    Dizziness Handicap Inventory (DHI) is a 25-question survey designed to quantify self-rated disability due to dizziness and unsteadiness, with scores ranging from 0 (least disabled, best outcome) to 100 (worst outcome). The minimally important difference is 18 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  14. EM3.4: SF6D utility (SF6DU) score at 4 years post-implantation, relative to pre-operative baseline, for the subgroup of participants who have ototoxic adult-onset BVH.

    SF6DU is a unitless health utility score computed from patient-reported replies to the SF6 health-related quality of life survey and ranging from 0 to 1, with higher scores meaning better outcome and minimally important difference 0.03 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  15. EM3.5: Dynamic Gait Index (DGI) score at 4 years post-implantation, relative to pre-operative.baseline, for the subgroup of participants who have ototoxic adult-onset BVH.

    DGI comprises 8 gait tasks scored by an examiner: walking on a level surface, changing gait speed, walking during horizontal head turns, walking during vertical head turns, pivoting, stepping over an obstacle, stepping around obstacles, and waling up and down stairs. Each task is scored (0-3 points, 3 is best). Raw DGI score is the sum of the eight subtest scores and ranges from 0 to 24, with higher scores meaning better outcome and minimally important difference 3.2 points.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  16. EM3.6: Gain (VHITG) of the vestibulo-ocular reflex, measured using the video head impulse test.averaged for the three implanted semicircular canals, relative to pre-operative baseline, for the subgroup of participants who have ototoxic adult-onset BVH.

    During video head impulse testing (vHIT), rotational eye and head movement are measured by a goggle-mounted camera and motion sensor during brief, fast ~10 degree head rotations about the axis of a semicircular canal being tested. Performance is quantified by vestibulo-ocular reflex (VOR) gain, which a ratio of eye movement to head movement (in this case the integral of eye velocity relative to the head and the additive inverse of the integral of head velocity, respectively). VHITG, the average vHIT VOR gain for each of the three semicircular canals of the implanted ear, typically ranges from 0 to 1, with higher numbers indicating better performance.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  17. SM0: Type, incidence and severity of unanticipated adverse device effects as of 4 years post-implantation

    Assess safety of the intervention, aggregating data across all implanted participants (diversified across ototoxic and non-ototoxic/non-central adult-onset BVH), as determined by incidence of adverse device-related events from pre-intervention to 4 years post-implantation.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  18. SM1.1: implant-side bone-conduction 4-frequency (0.5, 1, 2, 4 kHz) pure tone average detection threshold (BonePTAi)

    BonePTAi is the 4-frequency average of pure tone detection thresholds, in dBHL, for implant-side bone-conduction presentation of pure tones at 0.5, 1, 2 and 4 kHz. Range is -10 to 80 dBHL, with change toward smaller absolute values representing better (closer to normal) outcome.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  19. SM1.2: implant-side air-conduction 4-frequency pure tone average detection threshold (AirPTAi)

    AirPTAi is the 4-frequency average of pure tone detection thresholds, in dBHL, for implant-side air-conduction presentation of pure tones at 0.5, 1, 2 and 4 kHz. Range is -10 to 120 dBHL, with change toward smaller absolute values representing better (closer to normal) outcome.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  20. SM1.3: implant-side consonant-nucleus-consonant word discrimination score (CNCWi)

    CNCWi is the percentage of monosyllabic consonant-nucleus-consonant words correctly repeated when presented via an earphone speaker on the implanted side in a sound-isolation booth while a masking noise is played to the contralateral ear at 40 dB above its bone-conduction 4-frequency pure tone detection threshold if that threshold is at least 10 dB better than that of the ear being tested. CNCWi ranges from 0-100% correct, with higher score meaning better outcome.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  21. SM1.4: sound-field Arizona Biology (AzBios)27 sentences-in-noise discrimination score

    AzBios is the percentage of words correctly repeated when a set of 20 Arizona Biology sentences (randomly chosen without repeats from 15 sets) is presented at a moderate level (60 dB SPL) along with masking noise (simultaneous presentation of ten sentences from another set at aggregate sound level 55 dBSPL) to both ears via a sound field speaker in a sound-isolation booth. Scores range from 0-100% correct, with higher score meaning better outcome.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  22. SM1.5: Proportion of implanted ears that maintain American Academy of Otolaryngology - Head & Neck Surgery (AAO-HNS) 1995 Class A or B hearing13 or ≤ 30 dB change from preoperative baseline (if preoperative baseline is ≥20 dBHL) and ear-specific speech

    For ClassABCNCW, AAO-HNS (American Academy of Otolaryngology - Head \& Neck Surgery) 1995 Class A or B hearing is defined as AirPTAi not worse than 50 dBHL and CNCWi not worse than 50%. ClassABCNCW proportion ranges from 0-100%, with higher values meaning better outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  23. SM1.6: Proportion of implanted participants who maintain AAO-HNS 1995 Class A or B hearing or ≤ 30 dB change from preoperative baseline (if preoperative baseline is ≥20 dBHL) and ear-specific speech discrimination ≤30% worse than preoperative baseline

    For ClassABAzBio, AAO-HNS (American Academy of Otolaryngology - Head \& Neck Surgery) 1995 Class A or B hearing is defined as AirPTAi not worse than 50 dBHL and sound-field-presentation Arizona Biology sentences-in-noise discrimination score (AzBios) not worse than 50%. ClassABAzBio proportion ranges from 0-100%, with higher values meaning better outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  24. SM1.7: implant-side distortion-product otoacoustic emissions

    Distortion-product otoacoustic emissions (DPOAE) are sounds generated by a normal cochlea and detectable using a microphone in the ear canal when pairs of pure tones (centered on 0.75, 1, 1.5, 2, 3, 4, 6 and 8 kHz) are presented to the ear. DPOAE signals (and 8-valued vector for responses to stimuli centered on 0.75, 1, 1.5, 2, 3, 4, 6 and 8 kHz) are quantified in dB relative to the frequency-specific noise floor recorded by the same microphone before onset of stimulation. Response range is 0-15 dB, with higher values meaning better outcome.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  25. SM1.8: Ear canal acoustic admittance as assessed by implant-side tympanometry

    Tympanometry involves using an ear canal microphone to measure ear canal acoustic admittance (conventionally reported in units of mL) and volume (in mL) by sensing reflection of a 226 Hz tone presented via a speaker in the ear canal while ear canal pressure is slowly varied from -400 to 200 decaPascals. Negative bias pressures pull the ear drum outward, positive bias pressures push the ear drum inward, and acoustic admittance is greatest when the ear drum is in a neutral anatomic position, neither retracted inward nor ballooned outward. Results are conventionally represented graphically then summarized by a three-valued vector comprising peak compliance (range 0-2 milliliters (mL), values closer to normal range of 0.3-1.4 mL meaning more normal outcome), pressure at which compliance peaks (range -400 to 200 decaPascal, values closer to 0 meaning more normal outcome), and ear canal volume (range 0-3 mL, values closer to normal adult range of 0.6-1.4 meaning more normal outcome).

    Measured: 4 years post-implantation up to 5 years post-enrollment

  26. SM1.9: Tinnitus Handicap Inventory (THI)

    The Tinnitus Handicap Inventory (THI) survey is set of questions designed to quantify self-perceived handicap due to tinnitus. THI score ranges from 0-100. Higher scores mean worse outcome.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  27. SM1.10: Autophony Index (AI)

    The Autophony Index (AI) survey is set of questions designed to quantify self-perceived autophony (hearing one's voice or other internally-generated body sounds). AI score ranges from 0-104. Higher scores mean worse outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  28. SM1.11: cervical vestibular-evoked myogenic potential (cVEMP) response amplitude

    Cervical vestibular-evoked myogenic potentials (cVEMPs) are a measure of saccule-mediated inhibition of sternocleidomastoid muscle electromyographic (EMG) activity during presentation of loud tones to the ipsilateral ear. After normalizing to average rectified EMG activity (in microvolts) prior to sound stimulation, cVEMP amplitudes (in microvolts) are unitless. Values range from 0 to ~10, with larger values suggesting increased saccule activity and generally indicating better outcomes, except that values above 3.0 suggest abnormally high saccule sensitivity to sound.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  29. SM1.12: ocular vestibular-evoked myogenic potential (oVEMP) response amplitude

    Ocular vestibular-evoked myogenic potentials (oVEMPs) are a measure of utricle-mediated electromyographic (EMG) activity of inferior oblique and inferior rectus extraocular muscles during presentation of loud tones to the contralateral ear. Amplitude ranges from 0 to ~50 microvolts, with larger values generally suggesting increased utricle activity and better outcomes but values above 17 microvolts suggesting abnormally high utricle sensitivity to sound.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  30. SM1.13: subjective visual vertical (SVV) as assessed using the Bucket Test

    A participant's vision is occluded by a bucket oriented so that its axis aligns with the participant's nasooccipital axis. The examiner rotates the bucket about the axis to a new orientation, the participant reorients it until a line drawn on the floor of the bucket is judges by the participant to be Earth-vertical and deviation of that line from true vertical is recorded. Values range over -15 to 15 degrees, with smaller absolute values meaning more normal outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  31. SM1.14: scalp thickness at the location of implanted magnets (Tscalp)

    Scalp thickness at the location of implanted magnets (Tscalp) is measured in mm using a magnetic sensor. Range is 0 to 10 mm, with values closer to the range 3-7mm indicating better outcomes.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  32. SM1.15: all adverse events, including but not limited to events related to the surgical procedure, device and device systems

    Assess safety of the intervention, aggregating data across all implanted participants (diversified across ototoxic and non-ototoxic/non-central adult-onset BVH), as determined by changes in hearing and otolith endorgan function indicated by changes in all adverse events, including but not limited to events related to the surgical procedure, device and device systems.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  33. TM1: Proportion of all implanted participants who continue to use the MVI system daily at 4 years post-implantation

    Assess tolerance of the intervention, aggregating data across all implanted participants, as determined by the proportion of all implant recipients who continue to use the MVI system daily at 4 years post-implantation.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  34. TM2: Proportion of implanted participants with non-ototoxic/non-central adult-onset BVH who continue to use the MVI system daily at 4 years post-implantation

    Assess tolerance of the intervention, for the subgroup of participants who have non-ototoxic/non-central adult-onset BVH, as determined by the proportion of implanted participants with non-ototoxic/non-central adult-onset BVH who continue to use the MVI system daily at 4 years post-implantation.

    Measured: 4 years post-implantation up to 5 years post-enrollment

  35. TM3: Proportion of implanted participants with ototoxic adult-onset BVH who continue to use the MVI system daily at 4 years post-implantation

    Assess tolerance of the intervention, for the subgroup of participants who have ototoxic adult-onset BVH, as determined by the proportion of implanted participants with ototoxic adult-onset BVH who continue to use the MVI system daily at 4 years post-implantation.

    Measured: 4 years post-implantation up to 5 years post-enrollment

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Jul 2024
  2. Study start1 Dec 2024
  3. Primary completionDec 2029 (estimated)
  4. Study completionDec 2029 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
32 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06500975
Sponsor's protocol ID
IRB00434328
Status last verified
Mar 2026
First submitted
8 Jul 2024
Last updated
9 Mar 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Yes: Publication of de-identified data via peer-reviewed journals.

Publications

  • Sun DQ, Lehar M, Dai C, Swarthout L, Lauer AM, Carey JP, Mitchell DE, Cullen KE, Della Santina CC. Histopathologic Changes of the Inner ear in Rhesus Monkeys After Intratympanic Gentamicin Injection and Vestibular Prosthesis Electrode Array Implantation. J Assoc Res Otolaryngol. 2015 Jun;16(3):373-87. doi: 10.1007/s10162-015-0515-y. Epub 2015 Mar 20.

    PubMed 25790951
  • Sun DQ, Ward BK, Semenov YR, Carey JP, Della Santina CC. Bilateral Vestibular Deficiency: Quality of Life and Economic Implications. JAMA Otolaryngol Head Neck Surg. 2014 Jun;140(6):527-34. doi: 10.1001/jamaoto.2014.490.

    PubMed 24763518
  • Mitchell DE, Dai C, Rahman MA, Ahn JH, Della Santina CC, Cullen KE. Head movements evoked in alert rhesus monkey by vestibular prosthesis stimulation: implications for postural and gaze stabilization. PLoS One. 2013 Oct 17;8(10):e78767. doi: 10.1371/journal.pone.0078767. eCollection 2013.

    PubMed 24147142
  • Dai C, Fridman GY, Chiang B, Rahman MA, Ahn JH, Davidovics NS, Della Santina CC. Directional plasticity rapidly improves 3D vestibulo-ocular reflex alignment in monkeys using a multichannel vestibular prosthesis. J Assoc Res Otolaryngol. 2013 Dec;14(6):863-77. doi: 10.1007/s10162-013-0413-0. Epub 2013 Sep 8.

    PubMed 24013822
  • Ward BK, Agrawal Y, Hoffman HJ, Carey JP, Della Santina CC. Prevalence and impact of bilateral vestibular hypofunction: results from the 2008 US National Health Interview Survey. JAMA Otolaryngol Head Neck Surg. 2013 Aug 1;139(8):803-10. doi: 10.1001/jamaoto.2013.3913.

    PubMed 23949355
  • Valentin NS, Hageman KN, Dai C, Della Santina CC, Fridman GY. Development of a multichannel vestibular prosthesis prototype by modification of a commercially available cochlear implant. IEEE Trans Neural Syst Rehabil Eng. 2013 Sep;21(5):830-9. doi: 10.1109/TNSRE.2013.2259261. Epub 2013 May 1.

    PubMed 23649285
  • Davidovics NS, Rahman MA, Dai C, Ahn J, Fridman GY, Della Santina CC. Multichannel vestibular prosthesis employing modulation of pulse rate and current with alignment precompensation elicits improved VOR performance in monkeys. J Assoc Res Otolaryngol. 2013 Apr;14(2):233-48. doi: 10.1007/s10162-013-0370-7. Epub 2013 Jan 26.

    PubMed 23355001
  • Fridman GY, Della Santina CC. Progress toward development of a multichannel vestibular prosthesis for treatment of bilateral vestibular deficiency. Anat Rec (Hoboken). 2012 Nov;295(11):2010-29. doi: 10.1002/ar.22581. Epub 2012 Oct 8.

    PubMed 23044664
  • Rahman MA, Dai C, Fridman GY, Davidovics NS, Chiang B, Ahn J, Hayden R, Melvin TA, Sun DQ, Hedjoudje A, Della Santina CC. Restoring the 3D vestibulo-ocular reflex via electrical stimulation: the Johns Hopkins multichannel vestibular prosthesis project. Annu Int Conf IEEE Eng Med Biol Soc. 2011;2011:3142-5. doi: 10.1109/IEMBS.2011.6090857.

    PubMed 22255006
  • Dai C, Fridman GY, Davidovics NS, Chiang B, Ahn JH, Della Santina CC. Restoration of 3D vestibular sensation in rhesus monkeys using a multichannel vestibular prosthesis. Hear Res. 2011 Nov;281(1-2):74-83. doi: 10.1016/j.heares.2011.08.008. Epub 2011 Aug 26.

    PubMed 21888961
  • Dai C, Fridman GY, Chiang B, Davidovics NS, Melvin TA, Cullen KE, Della Santina CC. Cross-axis adaptation improves 3D vestibulo-ocular reflex alignment during chronic stimulation via a head-mounted multichannel vestibular prosthesis. Exp Brain Res. 2011 May;210(3-4):595-606. doi: 10.1007/s00221-011-2591-5. Epub 2011 Mar 4.

    PubMed 21374081
  • Dai C, Fridman GY, Della Santina CC. Effects of vestibular prosthesis electrode implantation and stimulation on hearing in rhesus monkeys. Hear Res. 2011 Jul;277(1-2):204-10. doi: 10.1016/j.heares.2010.12.021. Epub 2010 Dec 31.

    PubMed 21195755
  • Della Santina CC. Regaining balance with bionic ears. Sci Am. 2010 Apr;302(4):68-71. doi: 10.1038/scientificamerican0410-68. No abstract available.

    PubMed 20349578
  • Fridman GY, Davidovics NS, Dai C, Migliaccio AA, Della Santina CC. Vestibulo-ocular reflex responses to a multichannel vestibular prosthesis incorporating a 3D coordinate transformation for correction of misalignment. J Assoc Res Otolaryngol. 2010 Sep;11(3):367-81. doi: 10.1007/s10162-010-0208-5. Epub 2010 Feb 23.

    PubMed 20177732
  • Della Santina CC, Migliaccio AA, Patel AH. A multichannel semicircular canal neural prosthesis using electrical stimulation to restore 3-d vestibular sensation. IEEE Trans Biomed Eng. 2007 Jun;54(6 Pt 1):1016-30. doi: 10.1109/TBME.2007.894629.

    PubMed 17554821

Questions about this trial

What is this clinical trial studying?

A study testing Labyrinth Devices MVI™ Multichannel Vestibular Implant System in people with Bilateral Vestibular Hypofunction and Bilateral Vestibular Deficiency, run by Johns Hopkins University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 0 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 9 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Kelly Lane (410-502-8047, vestibularimplant@jhmi.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

PM1.1: Dynamic Gait Index (DGI)18 during motion-modulated implant stimulation at 4 years post-implantation, relative to pre-operative baseline, aggregated across all implant users. (time frame: 4 years post-implantation up to 5 years post-enrollment). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06500975, which also lists 18 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Mar 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in