AzTrials
AzTrials

Depth of AnesthesiaNCT06604156

Anesthesia Induction Scheme for Painless Gastrointestinal Endoscopy Patients Based on Nociceptive Stimulation Monitoring

An observational study of Depth of Anesthesia and Nociception, run by Min Su at 1 site in China.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

Nociception is the encoding and processing of noxious stimulation and is considered an objective indicator for monitoring pain. Currently, a new clinically-applied medical-engineering integrated monitoring device for noxious stimulation response has emerged. Read more about this study

Who is it for?
Ages 18 to 60 years
What is being tested?
EEG monitoring
How many people
220 participants
Where
1 siteChina
Study dates
1 Sep 2024to 31 Oct 2025
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 60 years
  • All sexes
  • No healthy volunteers
  • Adult

Study population: Aged 18-60 years old;Individuals scheduled for elective gastroscopy and colonoscopy examinations

Who may be able to join

  • Aged 18-60 years old;
  • American Society of Anesthesiologists (ASA) Class I-III;
  • Body mass index (BMI): 18-30 kg/m^2;
  • Individuals scheduled for elective gastroscopy and colonoscopy examinations;
  • Willing to comply with the experimental procedures and voluntarily sign the informed consent form

Who cannot join

  • Pregnant or breastfeeding women;
  • Individuals with allergies to sedatives/anesthetic drugs or other severe anesthetic risks;
  • Patients with chronic preoperative pain or a history of substance abuse;
  • Individuals with severe neurological diseases, such as stroke, hemiplegia, seizures, epilepsy, etc.;
  • Patients with clearly difficult airways, such as those with limited mouth opening, neck or jaw mobility restrictions, rheumatoid arthritis, or temporomandibular joint disorders;
  • Individuals with respiratory diseases, such as bronchitis, asthma, chronic obstructive pulmonary disease, or acute respiratory infections, which may lead to increased airway sensitivity;
Show all 9Show fewer
  • Patients with chronic pharyngitis, laryngitis, laryngeal edema, or recurrent laryngeal nerve paralysis that may affect normal throat function;
  • Individuals with esophagitis, esophageal strictures, or esophageal motility disorders that may cause difficulty swallowing or reflux;
  • Patients with poorly controlled life-threatening cardiovascular diseases, such as uncontrolled severe hypertension, severe arrhythmias, or unstable angina; 10.10.Patients with liver dysfunction (Child-Pugh grade C or above), acute upper gastrointestinal bleeding with shock, severe anemia, or gastrointestinal obstruction with retained gastric contents.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Su Min contact

China1 site, 1 recruiting
  • China,Chongqing The First Affiliated Hospital of Chongqing Medical University

    Chongqing, Chongqing Municipality, 400016

    Qin Liu, MD, 17713733719, 17713733719@163.com

    Recruiting

Other trials in China

About this study

Official title: The Effect of the Nociception Index (qNOX) in Painless Gastrointestinal Endoscopy :a Clinical Study

Nociception is the encoding and processing of noxious stimulation and is considered an objective indicator for monitoring pain. Currently, a new clinically-applied medical-engineering integrated monitoring device for noxious stimulation response has emerged. Its fundamental principle is based on the monitoring of electroencephalographic (EEG) activity, incorporating two monitoring parameters: the quantitative consciousness (qCON) index and the quantitative nociceptive (qNOX) index. However, in the context of sedation for gastrointestinal endoscopy, how the dynamic changes of the quantitative consciousness index (qCON) and the quantitative nociception index (qNOX) reflect the depth of sedation and nociceptive response remains unclear. Safe and effective sedation monitoring includes both direct visual monitoring and physiological monitoring, that is, monitoring the patient's hemodynamics and depth of sedation. This study utilizes qCON and qNOX monitoring to assess the sedation and analgesic states of patients undergoing painless gastroenterological endoscopy. By combining visual assessment (cough reflex, respiratory depression, and limb movement) with clinical physiological monitoring (vital signs monitoring and pulse oximetry), the aim is to explore the optimal sedation range for gastrointestinal endoscopy under sedation, providing new anesthesia monitoring tools for clinical use.

Read the detailed description

This is a single-center, prospective, observational clinical study. Study Objective: To explore the optimal sedation quality for painless gastrointestinal endoscopy. Study Protocol: A total of 220 patients undergoing painless gastrointestinal endoscopy were selected, with 110 patients undergoing gastroscopy and 110 patients undergoing colonoscopy. The bispectral index monitor (Apollo-9000A) was used to monitor the qCON and qNOX values of patients during the painless gastrointestinal endoscopy. The changes in qCON, qNOX, SBP (systolic blood pressure), DBP (diastolic blood pressure), MAP (mean arterial pressure), HR (heart rate), SpO2 (peripheral capillary oxygen saturation), and MOAA/S (Modified Observer's Assessment of Alertness/Sedation) scores at different time points during gastroscopy and colonoscopy were observed and recorded. The occurrence of adverse events during and after the examinations was also documented.

Being tested
EEG monitoring
Keywords
Painless Gastrointestinal endoscopy, depth of anesthesia, nociception

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • EEG monitoringDevice

    During gastrointestinal endoscopy, electroencephalogram (EEG) monitoring will be conducted using qCON and qNOX technologies to assess patients\' sedation and analgesia status while they undergo painless gastrointestinal endoscopy. This will be combined with visual assessments (such as cough reflex, respiratory depression, and limb movement) and clinical physiological monitoring (including vital signs and pulse oximetry) to explore and establish a stable and optimal depth of sedation for anesthesia.

Study groups in NCT06604156
Study groupRoleWhat they receive
Gastroscopy groupThis study used an EEG bispectral index monitor (Apolo 9000A) to monitor quantitative consciousness (qCON) index and quantitative nociceptive (qNOX) index during gastroscopy. Anesthesia induction was performed using 1.5-2.5mg/kg propofol and 3-5 μ g sufentanil; The injection speed of propofol is between 120s and 180s. When the patient's consciousness disappears (the patient's eyelash reflex disappears, and there is no response to calls and external stimuli), and the Modified Alertness/Sedation (MOAAS) score is ≤ 1, gastroscopy examination will begin. During the examination, propofol 4-12mg/kg. h will be pumped to make MOAA/S ≤ 1, and there will be no body movement reaction.
Receives: Device: EEG monitoring
Colonoscopy groupThis study used an EEG bispectral index monitor (Apolo 9000A) to monitor quantitative consciousness (qCON) index and quantitative nociceptive (qNOX) index during Colonoscopy. Anesthesia induction was performed using 1.5-2.5mg/kg propofol and 3-5 μ g sufentanil; The injection speed of propofol is between 120s and 180s. When the patient's consciousness disappears (the patient's eyelash reflex disappears, and there is no response to calls and external stimuli), and the Modified Alertness/Sedation (MOAAS) score is ≤ 1, Colonoscopy examination will begin. During the examination, propofol 4-12mg/kg. h will be pumped to make MOAA/S ≤ 1, and there will be no body movement reaction.
Receives: Device: EEG monitoring

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Anesthesia quality

    The quality of anesthesia and sedation during gastroscopy through the throat or colonoscopy through the anus (criteria: HR and SBP fluctuations within 10%; no movement or coughing response)

    Measured: during the procedure

Secondary outcomes (4)
  1. The values of qCON 、 qNOX、MAP、HR、SPO2 、and MOAA/S at different time points

    The Values of qCON 、 qNOX、MAP、HR、SPO2 and MOAA/S at different time points during gastroscopy and enteroscopy ① Time points for gastroscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the gastroscope (T2), Passage of the gastroscope through the pharynx (T3), After insertion of the gastroscope (T4), Withdrawal of the gastroscope to the pharynx (T5), Examination completion (T6), Admission to recovery room (T7), Awakening (T8), Discharge from recovery room (T9).

    ② Time points for colonoscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the colonoscope (T2), After insertion of the colonoscope into the anus (S3), Descending colon (T4), Splenic flexure (T5), Hepatic flexure (T6), Examination completion (T7), Admission to recovery room (T8), Awakening (T9), Discharge from recovery room (T10).

    Measured: during the procedure

  2. The values of qCON 、 qNOX、MAP、HR、SPO2 under special events

    During gastroscopy and colonoscopy , the values of qCON 、 qNOX、MAP、HR、SPO2 are recorded when coughing, body movement, polypectomy, or biopsy occur.

    Measured: during the procedure

  3. Adverse event

    Adverse events during gastroscopy and enteroscopy were recorded, including hypotension, hypertension, tachycardia, bradycardia, respiratory depression, hypoxemia, cough, body movement, nausea, vomiting, hiccup, injection pain, abdominal pain, abdominal distension, reflux aspiration.

    Measured: during the procedure

  4. Adverse events and complications after examination

    Bleeding, dizziness, blurred vision, nausea, vomiting, abdominal pain, abdominal distension were followed up 24h after the examination

    Measured: 24 hours after procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Sep 2024
  2. Study start1 Sep 2024
  3. Primary completion31 Aug 2025 (estimated)
  4. Study completion31 Oct 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
220 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06604156
Sponsor's protocol ID
2024-239-01
Status last verified
Mar 2025
First submitted
11 Apr 2024
Last updated
6 Mar 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Liu Q, Wei D, Han X, Cheng W, Yang X, Min S. qCON and qNOX-Guided Sedation Monitoring During Gastrointestinal Endoscopy: A Prospective Observational Preliminary Study. Ther Clin Risk Manag. 2026 Apr 15;22:593667. doi: 10.2147/TCRM.S593667. eCollection 2026.

    PubMed 42016204

Questions about this trial

What is this clinical trial studying?

An observational study of Depth of Anesthesia and Nociception, run by Min Su at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 6 Mar 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Qin Liu (17713733719, 17713733719@163.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Anesthesia quality (time frame: during the procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06604156, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Mar 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in