Meniscal TearsNCT06899659
Evaluation on Safety and Effectiveness of the An All-inside, All-suture Meniscal Repair Device
A study testing JuggerStitch™ Meniscal Repair Device and Fast-Fix 360 Meniscal Repair System in people with Meniscal Tears, run by Zimmer Biomet at 2 sites in China.
Trial summary
This study is a prospective, multi-center, randomized controlled pre-market clinical trial in China to evaluate the safety and efficacy of the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair. Read more about this study
- Who is it for?
- Ages 18 to 60 years
- Conditions the study is for
- Meniscal Tears
- What is being tested?
- JuggerStitch™ Meniscal Repair Device and Fast-Fix 360 Meniscal Repair System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 94 participants
- Where
- 2 sitesChina
- Study dates
- 14 Feb 2022to 29 Apr 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 60 years
- All sexes
- No healthy volunteers
- Adult
Who may be able to join
- Age between 18 and 60 years
- Scheduled for meniscal repair with a vertical longitudinal full-thickness tear (e.g., bucket-handle) in the red-red and red-white zones
- Able to understand all risks and benefits described in the informed consent form and willing to comply with the rehabilitation and follow-up visits specified in the clinical trial protocol
Who cannot join
- Meniscal tears in the avascular zone of the meniscus
- Meniscal tears not suitable for repair due to the degree of damage (marked irregularity and complex tearing) to the meniscus body, including degenerative, radial, horizontal cleavage, flap, and root tears
- Multiple ligament injuries of the affected knee joint
- Adhesion of the affected knee joint
- Planned intraoperative or postoperative intra-articular injection
- Articular surface cartilage injury of the targeted knee assessed by the - International Cartilage Repair Society (ICRS) is grade 3-4 Kellgren-Lawrence grades of documented radiographic evidence of osteoarthritis (OA) in the affected knee is ≥III
Show all 16Show fewer
- Instability or valgus/varus deformity (>5°) of the affected knee
- Acute or chronic, local or systemic infections
- Metabolic diseases
- Abnormal liver and kidney function (creatinine 3 times higher than the upper limit of normal value or alanine aminotransferase or aspartate aminotransferase 3 times higher than the upper limit of normal value) before operation
- History of operation in the affected knee
- Acute myocardial infarction or stroke occurred within 6 months before operation
- Known allergy to any material (polyethylene, polypropylene, polyester, polyetheretherketone) of the implants
- Pregnant or known to be pregnant
- Other circumstances that the researchers believe may affect the efficacy and safety evaluation of the investigated medical devices
- Currently participating in other clinical trials
Trial locations and contacts
2 sites in 1 country.
China2 sites
Huashan Hospital Affiliated to Fudan University
Shanghai, Shanghai Municipality, 200040
Huashan Hospital Affiliated to Fudan University
Shanghai, 200040
About this study
Official title: A Prospective Multi-Center, Randomized Controlled Pre-Market Clinical Trial to Assess the Safety and Effectiveness of the JuggerStitch™ Meniscal Repair Device for Arthroscopic Meniscal Repair
This study is a prospective, multi-center, randomized controlled pre-market clinical trial in China to evaluate the safety and efficacy of the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair. The study aims to compare the clinical outcomes of the JuggerStitch™ device with the Fast-Fix 360 Meniscal Repair System in patients with meniscal tears. The primary endpoint is the Lysholm Knee Score at 6 months postoperatively, and secondary endpoints include immediate device success rate, Tegner Activity Score, Visual Analogue Scale (VAS) score for pain, meniscal healing evaluated by MRI, and device-related adverse event rate. The study will enroll 94 subjects across 5 clinical sites.
Read the detailed description
- Purpose of the Study The purpose of this study is to evaluate the safety and efficacy of the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair in patients with meniscal tears. The study will compare the clinical outcomes of the JuggerStitch™ device with the Fast-Fix 360 Meniscal Repair System, a well-established device for meniscal repair.
- Study Design and Methodology This is a prospective, multi-center, randomized controlled pre-market clinical trial. The study will involve 5 clinical sites and will enroll a total of 94 subjects. Subjects will be randomly assigned to either the investigational group (JuggerStitch™ device) or the control group (Fast-Fix 360 device). The primary endpoint is the Lysholm Knee Score at 6 months postoperatively, and secondary endpoints include immediate device success rate, Tegner Activity Score, VAS score for pain, meniscal healing evaluated by MRI, and device-related adverse event rate.
- Inclusion and Exclusion Criteria 1) Inclusion Criteria: Age between 18 and 60 years; Scheduled for meniscal repair with a vertical longitudinal full-thickness tear (e.g., bucket-handle) in the red-red and red-white zones; Able to understand all risks and benefits described in the informed consent form and willing to comply with the rehabilitation and follow-up visits specified in the clinical trial protocol.
- Exclusion Criteria: Meniscal tears in the avascular zone of the meniscus; Meniscal tears not suitable for repair due to the degree of damage (marked irregularity and complex tearing) to the meniscus body, including degenerative, radial, horizontal cleavage, flap, and root tears; Multiple ligament injuries of the affected knee joint; Adhesion of the affected knee joint; Planned intraoperative or postoperative intra-articular injection; Articular surface cartilage injury of the targeted knee assessed by the International Cartilage Repair Society (ICRS) is grade 3-4; Kellgren-Lawrence grades of documented radiographic evidence of osteoarthritis (OA) in the affected knee is ≥III; Instability or valgus/varus deformity (>5°) of the affected knee; Acute or chronic, local or systemic infections; Metabolic diseases; Abnormal liver and kidney function (creatinine 3 times higher than the upper limit of normal value or alanine aminotransferase or aspartate aminotransferase 3 times higher than the upper limit of normal value) before operation; History of operation in the affected knee; Acute myocardial infarction or stroke occurred within 6 months before operation; Known allergy to any material (polyethylene, polypropylene, polyester, polyetheretherketone) of the implants; Pregnant or known to be pregnant; Other circumstances that the researchers believe may affect the efficacy and safety evaluation of the investigated medical devices; Currently participating in other clinical trials;
- Surgical Procedure The surgical procedure will involve arthroscopic exploration and repair of the meniscal tear using either the JuggerStitch™ device or the Fast-Fix 360 device. The specific steps for each device will be followed according to the manufacturer's instructions and the surgeon's standard operating procedures.
Postoperative Rehabilitation and Follow-up: Postoperative rehabilitation will include the use of an elastic bandage, appropriate massage to prevent blood clots, and guidance on quadriceps isometric contraction and straight leg-raising training. Subjects will be followed up at 3 months, 6 months, and 12 months postoperatively. At each follow-up visit, the Lysholm Knee Score, Tegner Activity Score, and VAS score for pain will be recorded. MRI of the knee joint will be performed at 6 months and 12 months postoperatively to evaluate meniscal healing.
Assessment of Efficacy and Safety: Efficacy will be assessed using the Lysholm Knee Score, Tegner Activity Score, and VAS score for pain. Safety will be assessed by monitoring and recording adverse events, including device-related adverse events, during the follow-up period.
Statistical Considerations: The sample size calculation is based on the difference in Lysholm Knee Score at 6 months postoperatively. A total of 94 subjects will be enrolled, with 47 subjects in each group. The primary endpoint will be analyzed using a covariance analysis model, and the secondary endpoints will be analyzed using appropriate statistical methods.
- Conditions
- Meniscal Tears
- Being tested
- JuggerStitch™ Meniscal Repair Device, Fast-Fix 360 Meniscal Repair System
- Keywords
- Meniscal Repair, Arthroscopic Surgery, JuggerStitch™ Meniscal Repair Device
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
JuggerStitch™ Meniscal Repair DeviceDevice
Participants assigned to investigational group undergoing arthroscopy meniscal repair with JuggerStitch™ Meniscal Repair Device.
Fast-Fix 360 Meniscal Repair SystemDevice
Participants assigned to control group undergoing arthroscopy meniscal repair with the Fast-Fix 360 Meniscal Repair System.
| Study group | Role | What they receive |
|---|---|---|
| Investigational Group | Experimental | Participants in this group will receive the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair. The JuggerStitch™ device is a new all-inside meniscal repair system that consists of a suture device and various auxiliary tools. It is designed to repair vertical longitudinal full-thickness tears (e.g., bucket-handle) in the red-red and red-white zones of the meniscus. Receives: Device: JuggerStitch™ Meniscal Repair Device |
| Control Group | Experimental | Participants in this group will receive the Fast-Fix 360 Meniscal Repair System for arthroscopic meniscal repair. The Fast-Fix 360 is a well-established all-inside meniscal repair device that consists of a suture and two fixed rods. It is designed to repair meniscal tears in a similar manner to the JuggerStitch™ device. Receives: Device: Fast-Fix 360 Meniscal Repair System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Lysholm Knee Score
The Lysholm Knee Score is a widely used and validated tool for assessing knee function, particularly in patients with meniscal injuries. It evaluates eight aspects of knee function: limp, use of cane or crutches, locking sensation, giving way sensation, pain, swelling, climbing stairs, and squatting. Each aspect is scored on a scale, and the total score ranges from 0 to 100, with higher scores indicating better knee function.
Measured: Post-op 6 months
Secondary outcomes (4)
Immediate Device Success Rate
The immediate device success rate is defined as the proportion of successful sutures of the injured site without any additional instruments (except matching surgical tools) during the operation. It is calculated as the number of successfully implanted anchors divided by the total number of implanted anchors, multiplied by 100%.
Measured: Intraoperatively
Tegner Activity Score
The Tegner Activity Score is a validated tool for assessing the level of physical activity in patients with knee injuries. It ranges from 0 (sick leave or disability pension because of knee problems) to 10 (competitive sports at a national elite level). The score is based on the highest level of activity the patient can participate in before and after the injury.
Measured: Post-op 3, 6, and 12 months
Visual Analogue Scale (VAS) Score for Pain
The VAS is a validated tool for assessing pain intensity. It is a 10 cm horizontal line, where 0 represents no pain and 10 represents the worst possible pain. Patients mark the point on the line that corresponds to their pain level.
Measured: Post-op 3, 6, and 12 months
Meniscal Healing Evaluated by Magnetic Resonance Imaging (MRI)
MRI will be used to evaluate the healing of the meniscus at 6 and 12 months postoperatively. The MRI results will be classified according to the MRI classification for meniscal tear after arthroscopy repair, which ranges from Grade 0 (normal) to Grade III (high signal in the meniscus reaches the articular surface of the meniscus).
Measured: Post-op 6 and 12 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Mar 2025
- Study start14 Feb 2022
- Primary completion30 Oct 2023
- Study completion29 Apr 2024
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Meniscal TearsStudies of the same condition, open and under way.
- More trials run by Zimmer BiometThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Participants will be randomly assigned to one of two parallel groups: the investigational group (JuggerStitch™ Meniscal Repair Device) or the control group (Fast-Fix 360 Meniscal Repair System).
- Masking
- None (open label)
- Enrolment
- 94 participants (actual)
Sponsor and investigators
- Lead sponsor
- Zimmer Biomet
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Huashan Hospital, Hunan Provincial People's Hospital, Wuhan TongJi Hospital, First Affiliated Hospital of Jinan University
- Responsible party
- Sponsor
- Investigators
- Shiyi Chen, MD, Principal investigator, Huashan Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06899659
- Sponsor's protocol ID
- CEA2020-26SM
- Status last verified
- Mar 2025
- First submitted
- 19 Feb 2025
- Last updated
- 28 Mar 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No: The study does not currently have a plan to share individual participant data due to privacy and confidentiality concerns. The data may contain sensitive information that could potentially identify participants, and sharing it could compromise their privacy. Additionally, the study is subject to regulatory and ethical requirements that limit the sharing of individual participant data.
Study at a glance
From the registry record, last updated by the sponsor on 28 Mar 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective Multi-Center, Randomized Controlled Pre-Market Clinical Trial to Assess the Safety and Effectiveness of the JuggerStitch™ Meniscal Repair Device for Arthroscopic Meniscal Repair
- ClinicalTrials.gov ID
- NCT06899659
- Acronym / sponsor ID
- CEA2020-26SM
- Conditions
- Meniscal Tears
- Keywords
- Meniscal Repair, Arthroscopic Surgery, JuggerStitch™ Meniscal Repair Device
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 94 participants (actual)
- Lead sponsor
- Zimmer BiometIndustry (pharma, biotech, devices)
- Collaborators
- Huashan Hospital, Hunan Provincial People's Hospital, Wuhan TongJi Hospital, First Affiliated Hospital of Jinan University
- Study start
- 14 Feb 2022 (actual)
- Primary completion
- 30 Oct 2023 (actual)
- Study completion
- 29 Apr 2024 (actual)
- First posted
- 28 Mar 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is a prospective, multi-center, randomized controlled pre-market clinical trial in China to evaluate the safety and efficacy of the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair. The study aims to compare the clinical outcomes of the JuggerStitch™ device with the Fast-Fix 360 Meniscal Repair System in patients with meniscal tears. The primary endpoint is the Lysholm Knee Score at 6 months postoperatively, and secondary endpoints include immediate device success rate, Tegner Activity Score, Visual Analogue Scale (VAS) score for pain, meniscal healing evaluated by MRI, and device-related adverse event rate. The study will enroll 94 subjects across 5 clinical sites.
Detailed description
- Purpose of the Study The purpose of this study is to evaluate the safety and efficacy of the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair in patients with meniscal tears. The study will compare the clinical outcomes of the JuggerStitch™ device with the Fast-Fix 360 Meniscal Repair System, a well-established device for meniscal repair.
- Study Design and Methodology This is a prospective, multi-center, randomized controlled pre-market clinical trial. The study will involve 5 clinical sites and will enroll a total of 94 subjects. Subjects will be randomly assigned to either the investigational group (JuggerStitch™ device) or the control group (Fast-Fix 360 device). The primary endpoint is the Lysholm Knee Score at 6 months postoperatively, and secondary endpoints include immediate device success rate, Tegner Activity Score, VAS score for pain, meniscal healing evaluated by MRI, and device-related adverse event rate.
- Inclusion and Exclusion Criteria 1) Inclusion Criteria: Age between 18 and 60 years; Scheduled for meniscal repair with a vertical longitudinal full-thickness tear (e.g., bucket-handle) in the red-red and red-white zones; Able to understand all risks and benefits described in the informed consent form and willing to comply with the rehabilitation and follow-up visits specified in the clinical trial protocol.
- Exclusion Criteria: Meniscal tears in the avascular zone of the meniscus; Meniscal tears not suitable for repair due to the degree of damage (marked irregularity and complex tearing) to the meniscus body, including degenerative, radial, horizontal cleavage, flap, and root tears; Multiple ligament injuries of the affected knee joint; Adhesion of the affected knee joint; Planned intraoperative or postoperative intra-articular injection; Articular surface cartilage injury of the targeted knee assessed by the International Cartilage Repair Society (ICRS) is grade 3-4; Kellgren-Lawrence grades of documented radiographic evidence of osteoarthritis (OA) in the affected knee is ≥III; Instability or valgus/varus deformity (>5°) of the affected knee; Acute or chronic, local or systemic infections; Metabolic diseases; Abnormal liver and kidney function (creatinine 3 times higher than the upper limit of normal value or alanine aminotransferase or aspartate aminotransferase 3 times higher than the upper limit of normal value) before operation; History of operation in the affected knee; Acute myocardial infarction or stroke occurred within 6 months before operation; Known allergy to any material (polyethylene, polypropylene, polyester, polyetheretherketone) of the implants; Pregnant or known to be pregnant; Other circumstances that the researchers believe may affect the efficacy and safety evaluation of the investigated medical devices; Currently participating in other clinical trials;
- Surgical Procedure The surgical procedure will involve arthroscopic exploration and repair of the meniscal tear using either the JuggerStitch™ device or the Fast-Fix 360 device. The specific steps for each device will be followed according to the manufacturer's instructions and the surgeon's standard operating procedures.
Postoperative Rehabilitation and Follow-up: Postoperative rehabilitation will include the use of an elastic bandage, appropriate massage to prevent blood clots, and guidance on quadriceps isometric contraction and straight leg-raising training. Subjects will be followed up at 3 months, 6 months, and 12 months postoperatively. At each follow-up visit, the Lysholm Knee Score, Tegner Activity Score, and VAS score for pain will be recorded. MRI of the knee joint will be performed at 6 months and 12 months postoperatively to evaluate meniscal healing.
Assessment of Efficacy and Safety: Efficacy will be assessed using the Lysholm Knee Score, Tegner Activity Score, and VAS score for pain. Safety will be assessed by monitoring and recording adverse events, including device-related adverse events, during the follow-up period.
Statistical Considerations: The sample size calculation is based on the difference in Lysholm Knee Score at 6 months postoperatively. A total of 94 subjects will be enrolled, with 47 subjects in each group. The primary endpoint will be analyzed using a covariance analysis model, and the secondary endpoints will be analyzed using appropriate statistical methods.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- Participants will be randomly assigned to one of two parallel groups: the investigational group (JuggerStitch™ Meniscal Repair Device) or the control group (Fast-Fix 360 Meniscal Repair System).
| Arm | Type | Receives |
|---|---|---|
| Investigational Group | Experimental | Device: JuggerStitch™ Meniscal Repair DeviceParticipants in this group will receive the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair. The JuggerStitch™ device is a new all-inside meniscal repair system that consists of a suture device and various auxiliary tools. It is designed to repair vertical longitudinal full-thickness tears (e.g., bucket-handle) in the red-red and red-white zones of the meniscus. |
| Control Group | Experimental | Device: Fast-Fix 360 Meniscal Repair SystemParticipants in this group will receive the Fast-Fix 360 Meniscal Repair System for arthroscopic meniscal repair. The Fast-Fix 360 is a well-established all-inside meniscal repair device that consists of a suture and two fixed rods. It is designed to repair meniscal tears in a similar manner to the JuggerStitch™ device. |
Who may qualify
- Ages
- 18 to 60 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult
Key inclusion criteria (3 listed)
- Age between 18 and 60 years
- Scheduled for meniscal repair with a vertical longitudinal full-thickness tear (e.g., bucket-handle) in the red-red and red-white zones
- Able to understand all risks and benefits described in the informed consent form and willing to comply with the rehabilitation and follow-up visits specified in the clinical trial protocol
Key exclusion criteria (16 listed)
- Meniscal tears in the avascular zone of the meniscus
- Meniscal tears not suitable for repair due to the degree of damage (marked irregularity and complex tearing) to the meniscus body, including degenerative, radial, horizontal cleavage, flap, and root tears
- Multiple ligament injuries of the affected knee joint
- Adhesion of the affected knee joint
- Planned intraoperative or postoperative intra-articular injection
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| JuggerStitch™ Meniscal Repair DeviceParticipants assigned to investigational group undergoing arthroscopy meniscal repair with JuggerStitch™ Meniscal Repair Device. | Device | Investigational Group |
| Fast-Fix 360 Meniscal Repair SystemParticipants assigned to control group undergoing arthroscopy meniscal repair with the Fast-Fix 360 Meniscal Repair System. | Device | Control Group |
Primary outcome
Lysholm Knee Score
Time frame: Post-op 6 months
The Lysholm Knee Score is a widely used and validated tool for assessing knee function, particularly in patients with meniscal injuries. It evaluates eight aspects of knee function: limp, use of cane or crutches, locking sensation, giving way sensation, pain, swelling, climbing stairs, and squatting. Each aspect is scored on a scale, and the total score ranges from 0 to 100, with higher scores indicating better knee function.
4 secondary outcomes
Immediate Device Success Rate
Time frame: Intraoperatively
Tegner Activity Score
Time frame: Post-op 3, 6, and 12 months
Visual Analogue Scale (VAS) Score for Pain
Time frame: Post-op 3, 6, and 12 months
Meniscal Healing Evaluated by Magnetic Resonance Imaging (MRI)
Time frame: Post-op 6 and 12 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 28 Mar 2025.
- Individual participant dataSharing planned: No. The study does not currently have a plan to share individual participant data due to privacy and confidentiality concerns. The data may contain sensitive information that could potentially identify participants, and sharing it could compromise their privacy. Additionally, the study is subject to regulatory and ethical requirements that limit the sharing of individual participant data.
Related trials for Meniscal Tears
Recruiting
Effects of Pulsed Electromagnetic Field Therapy on Meniscal Healing, Symptom Relief, and Knee Function
Meniscal Tears
Recruiting
Novel Bioactive Sleeve on Pain and PROMs
Meniscus Tear
Active, not recruitingPhase 3
Dronabinol After Arthroscopic Surgery
Knee Osteoarthritis, Knee Injuries
Not yet recruiting
Needle Arthroscopy vs Conventional Arthroscopy in Knees
Meniscectomy, Meniscal Tears
Recruiting
This is a Study to Verify if Marrow Venting Procedure Can Improve Meniscal Suture Healing
Meniscal Tear
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Shiyi Chen, MD principal investigator
Huashan Hospital
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing JuggerStitch™ Meniscal Repair Device and Fast-Fix 360 Meniscal Repair System in people with Meniscal Tears, run by Zimmer Biomet at 2 sites in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 28 Mar 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Lysholm Knee Score (time frame: Post-op 6 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Mar 2025.