In-stent RestenosisPhase 1/2NIMBLE-INCT06968858
Pilot Study of the α Prototype NIMBLE System: Feasibility, Safety, and Initial Performance in Non-Invasive Detection of Coronary In-Stent Restenosis
A Phase 1/2 study testing NIMBLE test in people with In-stent Restenosis and Stent Fracture, run by Nimble Diagnostics S.L. at 1 site in Spain.
Trial summary
The NIMBLE-I study is a prospective, unicentric, single arm, feasibility clinical trial designed to evaluate a novel medical device for the non-invasive monitoring of coronary stents. The study is being conducted at the Hospital Germans Trias i Pujol in Badalona, Spain, under the supervision of Dr. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- In-stent Restenosis, Stent Fracture, Stent Complication
- What is being tested?
- NIMBLE test
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 30 participants
- Where
- 1 siteSpain
- Study dates
- 12 Sep 2024to Oct 2025
- Phase
- Phase 1/2
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Prior implantation of one or more coronary stents
- Clinical symptoms suggestive of stent failure (e.g., chest pain, ischemic ECG changes)
- Undergoing scheduled coronary angiography
- Informed consent provided
Who cannot join
- Pregnancy
- Implanted electronic devices (e.g., pacemakers) that may interfere with MWI
- Inability to provide consent
- Chest conditions preventing correct positioning of the device
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Spain1 site, 1 recruiting
- Recruiting
Hospital Universitari Germans Trias i Pujol
Badalona, Catalonia, 08916
Oriol Rodriguez Leor, MD, PhD, 93 465 12 00, cardiologia.germanstrias@gencat.cat
Oriol Dr. Rodriguez-Leor, MD, PhD
About this study
Official title: First-in-human Study to Assess the Clinical Feasibility, Safety, and Performance of the α Prototype of the NIMBLE System for Diagnosing Complications in Intracoronary Stents. NIMBLE-I Study.
The NIMBLE-I study is a prospective, unicentric, single arm, feasibility clinical trial designed to evaluate a novel medical device for the non-invasive monitoring of coronary stents. The study is being conducted at the Hospital Germans Trias i Pujol in Badalona, Spain, under the supervision of Dr. Oriol Rodríguez Leor, an experienced interventional cardiologist. It is sponsored by NIMBLE Diagnostics, a company developing the NIMBLE system-a non-ionizing, non-invasive prototype based on microwave interferometry (MWI).
The motivation behind the study stems from the clinical challenge of detecting in-stent restenosis (ISR), a common complication following stent implantation that affects up to 10% of patients. Current diagnostic methods typically rely on invasive procedures such as coronary angiography or intravascular imaging, which are resource-intensive and carry procedural risks. The NIMBLE system has the potential to address this need by providing a safe, fast, and non-invasive alternative capable of detecting structural changes around coronary stents.
Read more
The primary objective of the NIMBLE-I study is to assess the technical feasibility of the NIMBLE device in a real-world clinical setting. Secondary objectives include evaluating the safety of the device, generating preliminary data on its effectiveness by comparing its measurements with those obtained from invasive coronary angiography-the reference standard for diagnosing ISR-and collecting usability data to inform improvements in future versions of the device.
The study is designed to enroll up to 120 patients of whom 30 will undergo an OCT examination to evaluate the ability of the α prototype to measure ISR. Participants must be adults with previously implanted coronary stents who present with symptoms suggestive of ISR-such as chest pain or ischemic changes on an electrocardiogram-and are already scheduled for diagnostic angiography. Patients with contraindications such as pregnancy, implanted electronic devices (like pacemakers), or anatomical limitations that preclude correct device positioning will be excluded.
The procedure begins with obtaining informed consent from eligible patients. Prior to the scheduled angiographic procedure, the NIMBLE system is used to perform a non-invasive scan. The device, which includes biocompatible transducers, is placed externally over the patient's chest at the level of the coronary stent. Data acquisition does not interfere with standard clinical care. After the NIMBLE scan, patients proceed with their routine coronary angiography as per standard of care. Importantly, operators performing the angiography remain blinded to the results of the NIMBLE device.
Data analysis will focus on two main areas. The primary endpoint is the successful completion of NIMBLE measurements without device-related adverse events. Secondary endpoints include the agreement between NIMBLE output-specifically, a calculated metric called %RIS (percent restenosis intrastent)-and angiographic findings. Statistical methods will be applied to assess sensitivity, specificity, correlation, and agreement between modalities. Usability feedback from clinical operators will also be collected to inform future device iterations.
The study complies with all applicable regulatory and ethical guidelines, including ISO 14155 and the European Medical Device Regulation (MDR 2017/745). It has been approved by the relevant ethics committee and competent authority before its launch. Each patient's data will be anonymized and handled according to Good Clinical Practice (GCP) standards.
Expected outcomes from the NIMBLE-I study include confirmation that the device can be safely and effectively used in a clinical context and that its diagnostic output correlates with invasive imaging findings. Positive results will lay the groundwork for a pivotal clinical trial and advance the development of a tool that could significantly improve the follow-up of patients with coronary stents. Ultimately, this technology could reduce the need for invasive procedures and enable earlier detection of stent-related complications in an outpatient setting.
Read the detailed description
The NIMBLE-I study is a prospective, single-center, single-arm pilot clinical trial designed to assess the feasibility, safety, usability, and preliminary diagnostic performance of the NIMBLE prototype system. This study represents a significant step forward in the development of non-invasive tools for the detection of complications associated with coronary stents. It is sponsored by NIMBLE Diagnostics and takes place at the Hospital Germans Trias i Pujol in Badalona, Spain, under the leadership of Dr. Oriol Rodríguez Leor, an expert in interventional cardiology.
The rationale behind this study lies in the persistent clinical challenge of in-stent restenosis (ISR)-the re-narrowing of a coronary artery segment within a previously implanted stent. ISR continues to affect 5-10% of all percutaneous coronary intervention (PCI) cases despite advances in stent design and pharmacological therapy. Typically, ISR is diagnosed through invasive procedures such as coronary angiography or intravascular imaging (e.g., IVUS or OCT), which involve patient risk, high cost, and hospital-based infrastructure. The NIMBLE system, which employs microwave interferometry (MWI), offers a novel, non-invasive, and non-ionizing approach aimed at detecting tissue-level changes and structural anomalies suggestive of ISR. The system functions through external thoracic placement of signal transducers, which detect signal interactions with implanted metallic stents.
The primary objective of the NIMBLE-I trial is to demonstrate the technical feasibility and safety of using the NIMBLE prototype in real clinical settings. A secondary objective is to explore the potential of the device in identifying patients with significant ISR by comparing its diagnostic outputs with those of conventional invasive coronary angiography, the current standrd of care. Also, the study will alow to identify potential areas for improvement of the device.
The study plans to include up to 120 patients, of whom 30 will undergo an OCT examination to evaluate the ability of the α prototype to measure ISR. All participants must be adults with a previously implanted coronary stent and present with clinical symptoms suggestive of stent-related complications, such as chest pain or ischemic changes on an ECG. Only patients already scheduled to undergo a diagnostic coronary angiogram as part of their routine care will be eligible. Key exclusion criteria include pregnancy, the presence of implanted electronic medical devices that could interfere with microwave signals (such as pacemakers or defibrillators), or any anatomical constraints that would make transducer placement ineffective.
The clinical procedure begins with the acquisition of written informed consent. Prior to undergoing coronary angiography, each patient is evaluated with the NIMBLE device. The transducers are positioned externally on the patient's chest, over the region of the implanted stent. The measurement session is brief and completely non-invasive, with no interference in the patient's scheduled care. The system captures signal patterns and calculates a parameter which reflects potential stent obstruction. Once the NIMBLE scan is complete, the patient proceeds to undergo standard invasive angiography. Importantly, the interventional team conducting the angiography is blinded to the NIMBLE results to maintain the objectivity of comparative data.
The study's primary endpoint is the successful acquisition of data using the NIMBLE system and without the occurrence of any adverse event. The secondary endpoints include the comparison of RIS values with angiographic findings, the determination of diagnostic performance metrics such as sensitivity and specificity, and the collection of usability data from clinicians interacting with the device. The evaluation will include both descriptive and comparative statistics, and an interim analysis may be conducted following the initial patient roll-in phase.
The NIMBLE-I study follows all relevant ethical and regulatory standards, including the principles of the Declaration of Helsinki, ISO 14155 for clinical investigation of medical devices, and the EU Medical Device Regulation (MDR 2017/745). All procedures have been reviewed and approved by the local ethics committee and competent health authority. Patient confidentiality and data protection are ensured in accordance with Good Clinical Practice (GCP) guidelines.
The anticipated outcome of this study is the validation of the NIMBLE prototype as a safe and technically reliable tool that can be integrated into the clinical workflow for evaluating coronary stents. A successful pilot study will not only support the technical claims of the system but also provide essential data for the design of a larger pivotal clinical trial. Ultimately, the NIMBLE system could transform the monitoring paradigm of coronary stents by allowing non-invasive, outpatient follow-up, potentially reducing healthcare costs and procedural risks while improving patient comfort and diagnostic accuracy.
- Conditions
- In-stent Restenosis, Stent Fracture, Stent Complication
- Being tested
- NIMBLE test
- Keywords
- non-invasive, microwave, prototype, nimble, in-stent restenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
NIMBLE testDiagnostic test
Non-invasive assessment of ISR with the NIMBLE System (Microwave Interferometry)
| Study group | Role | What they receive |
|---|---|---|
| Experimental | Experimental | Patients undergoing NIMBLE System measurement prior to coronary angiography Receives: Diagnostic Test: NIMBLE test |
What is being measured
The primary outcome is the main question the study is designed to answer.
Feasibility
Feasibility will be assessed by the proportion of enrolled patients in whom the NIMBLE System measurement can be successfully completed and a usable diagnostic output is obtained.
Measured: prior angiography
Safety
Absence of device-related adverse events
Measured: 7 days after Nimble test
Secondary outcomes (2)
Performance
The performance of the α prototype of the NIMBLE System will be evaluated by comparing its diagnostic measurements to those obtained through invasive coronary angiography, which is considered the clinical reference standard for identifying ISR.
Measured: DWithin 24 hours before invasive coronary angiography (single time point assessment)
Usability
Usability will be assessed through a structured questionnaire completed by the clinical operator. Additional qualitative feedback from operators may also be collected to evaluate ease of use, setup time, and integration into the clinical workflow. The patient usability component is also evaluated through a brief post-procedure questionnaire assessing perceived comfort, clarity of instructions, and overall acceptability of the NIMBLE System.
Measured: User (operator) questionnaire will be administered immediately after the NIMBLE System measurement in the first and last enrolled patients. Patient questionnaire will be administered to every participant immediately after their NIMBLE measurement, on the
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 May 2025
- Study start12 Sep 2024
- Primary completionSep 2025 (estimated)
- Study completionOct 2025 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for In-stent RestenosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 1/2
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- All enrolled participants will undergo a single, non-invasive measurement with the NIMBLE System prior to their scheduled invasive coronary angiography. No randomization or comparison groups are included. A subset of 30 participants will also undergo optical coherence tomography (OCT) to provide additional reference data. Usability and safety assessments will be conducted based on operator and patient feedback.
- Masking
- None (open label)
- Enrolment
- 30 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Nimble Diagnostics S.L.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Oriol Rodriguez-Leor, MD, PhD, Principal investigator, Germans Trias i Pujol Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06968858
- Sponsor's protocol ID
- NDX-0001
- Acronym
- NIMBLE-I
- Status last verified
- May 2025
- First submitted
- 24 Apr 2025
- Last updated
- 13 May 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 13 May 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- First-in-human Study to Assess the Clinical Feasibility, Safety, and Performance of the α Prototype of the NIMBLE System for Diagnosing Complications in Intracoronary Stents. NIMBLE-I Study.
- ClinicalTrials.gov ID
- NCT06968858
- Acronym / sponsor ID
- NIMBLE-I / NDX-0001
- Conditions
- In-stent Restenosis, Stent Fracture, Stent Complication
- Keywords
- non-invasive, microwave, prototype, nimble, in-stent restenosis
- Phase
- Phase 1/2
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 30 participants (estimated)
- Lead sponsor
- Nimble Diagnostics S.L.Industry (pharma, biotech, devices)
- Study start
- 12 Sep 2024 (actual)
- Primary completion
- Sep 2025 (estimated)
- Study completion
- Oct 2025 (estimated)
- First posted
- 13 May 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The NIMBLE-I study is a prospective, unicentric, single arm, feasibility clinical trial designed to evaluate a novel medical device for the non-invasive monitoring of coronary stents. The study is being conducted at the Hospital Germans Trias i Pujol in Badalona, Spain, under the supervision of Dr. Oriol Rodríguez Leor, an experienced interventional cardiologist. It is sponsored by NIMBLE Diagnostics, a company developing the NIMBLE system-a non-ionizing, non-invasive prototype based on microwave interferometry (MWI).
The motivation behind the study stems from the clinical challenge of detecting in-stent restenosis (ISR), a common complication following stent implantation that affects up to 10% of patients. Current diagnostic methods typically rely on invasive procedures such as coronary angiography or intravascular imaging, which are resource-intensive and carry procedural risks. The NIMBLE system has the potential to address this need by providing a safe, fast, and non-invasive alternative capable of detecting structural changes around coronary stents.
The primary objective of the NIMBLE-I study is to assess the technical feasibility of the NIMBLE device in a real-world clinical setting. Secondary objectives include evaluating the safety of the device, generating preliminary data on its effectiveness by comparing its measurements with those obtained from invasive coronary angiography-the reference standard for diagnosing ISR-and collecting usability data to inform improvements in future versions of the device.
The study is designed to enroll up to 120 patients of whom 30 will undergo an OCT examination to evaluate the ability of the α prototype to measure ISR. Participants must be adults with previously implanted coronary stents who present with symptoms suggestive of ISR-such as chest pain or ischemic changes on an electrocardiogram-and are already scheduled for diagnostic angiography. Patients with contraindications such as pregnancy, implanted electronic devices (like pacemakers), or anatomical limitations that preclude correct device positioning will be excluded.
The procedure begins with obtaining informed consent from eligible patients. Prior to the scheduled angiographic procedure, the NIMBLE system is used to perform a non-invasive scan. The device, which includes biocompatible transducers, is placed externally over the patient's chest at the level of the coronary stent. Data acquisition does not interfere with standard clinical care. After the NIMBLE scan, patients proceed with their routine coronary angiography as per standard of care. Importantly, operators performing the angiography remain blinded to the results of the NIMBLE device.
Data analysis will focus on two main areas. The primary endpoint is the successful completion of NIMBLE measurements without device-related adverse events. Secondary endpoints include the agreement between NIMBLE output-specifically, a calculated metric called %RIS (percent restenosis intrastent)-and angiographic findings. Statistical methods will be applied to assess sensitivity, specificity, correlation, and agreement between modalities. Usability feedback from clinical operators will also be collected to inform future device iterations.
The study complies with all applicable regulatory and ethical guidelines, including ISO 14155 and the European Medical Device Regulation (MDR 2017/745). It has been approved by the relevant ethics committee and competent authority before its launch. Each patient's data will be anonymized and handled according to Good Clinical Practice (GCP) standards.
Expected outcomes from the NIMBLE-I study include confirmation that the device can be safely and effectively used in a clinical context and that its diagnostic output correlates with invasive imaging findings. Positive results will lay the groundwork for a pivotal clinical trial and advance the development of a tool that could significantly improve the follow-up of patients with coronary stents. Ultimately, this technology could reduce the need for invasive procedures and enable earlier detection of stent-related complications in an outpatient setting.
Detailed description
The NIMBLE-I study is a prospective, single-center, single-arm pilot clinical trial designed to assess the feasibility, safety, usability, and preliminary diagnostic performance of the NIMBLE prototype system. This study represents a significant step forward in the development of non-invasive tools for the detection of complications associated with coronary stents. It is sponsored by NIMBLE Diagnostics and takes place at the Hospital Germans Trias i Pujol in Badalona, Spain, under the leadership of Dr. Oriol Rodríguez Leor, an expert in interventional cardiology.
The rationale behind this study lies in the persistent clinical challenge of in-stent restenosis (ISR)-the re-narrowing of a coronary artery segment within a previously implanted stent. ISR continues to affect 5-10% of all percutaneous coronary intervention (PCI) cases despite advances in stent design and pharmacological therapy. Typically, ISR is diagnosed through invasive procedures such as coronary angiography or intravascular imaging (e.g., IVUS or OCT), which involve patient risk, high cost, and hospital-based infrastructure. The NIMBLE system, which employs microwave interferometry (MWI), offers a novel, non-invasive, and non-ionizing approach aimed at detecting tissue-level changes and structural anomalies suggestive of ISR. The system functions through external thoracic placement of signal transducers, which detect signal interactions with implanted metallic stents.
The primary objective of the NIMBLE-I trial is to demonstrate the technical feasibility and safety of using the NIMBLE prototype in real clinical settings. A secondary objective is to explore the potential of the device in identifying patients with significant ISR by comparing its diagnostic outputs with those of conventional invasive coronary angiography, the current standrd of care. Also, the study will alow to identify potential areas for improvement of the device.
The study plans to include up to 120 patients, of whom 30 will undergo an OCT examination to evaluate the ability of the α prototype to measure ISR. All participants must be adults with a previously implanted coronary stent and present with clinical symptoms suggestive of stent-related complications, such as chest pain or ischemic changes on an ECG. Only patients already scheduled to undergo a diagnostic coronary angiogram as part of their routine care will be eligible. Key exclusion criteria include pregnancy, the presence of implanted electronic medical devices that could interfere with microwave signals (such as pacemakers or defibrillators), or any anatomical constraints that would make transducer placement ineffective.
The clinical procedure begins with the acquisition of written informed consent. Prior to undergoing coronary angiography, each patient is evaluated with the NIMBLE device. The transducers are positioned externally on the patient's chest, over the region of the implanted stent. The measurement session is brief and completely non-invasive, with no interference in the patient's scheduled care. The system captures signal patterns and calculates a parameter which reflects potential stent obstruction. Once the NIMBLE scan is complete, the patient proceeds to undergo standard invasive angiography. Importantly, the interventional team conducting the angiography is blinded to the NIMBLE results to maintain the objectivity of comparative data.
The study's primary endpoint is the successful acquisition of data using the NIMBLE system and without the occurrence of any adverse event. The secondary endpoints include the comparison of RIS values with angiographic findings, the determination of diagnostic performance metrics such as sensitivity and specificity, and the collection of usability data from clinicians interacting with the device. The evaluation will include both descriptive and comparative statistics, and an interim analysis may be conducted following the initial patient roll-in phase.
The NIMBLE-I study follows all relevant ethical and regulatory standards, including the principles of the Declaration of Helsinki, ISO 14155 for clinical investigation of medical devices, and the EU Medical Device Regulation (MDR 2017/745). All procedures have been reviewed and approved by the local ethics committee and competent health authority. Patient confidentiality and data protection are ensured in accordance with Good Clinical Practice (GCP) guidelines.
The anticipated outcome of this study is the validation of the NIMBLE prototype as a safe and technically reliable tool that can be integrated into the clinical workflow for evaluating coronary stents. A successful pilot study will not only support the technical claims of the system but also provide essential data for the design of a larger pivotal clinical trial. Ultimately, the NIMBLE system could transform the monitoring paradigm of coronary stents by allowing non-invasive, outpatient follow-up, potentially reducing healthcare costs and procedural risks while improving patient comfort and diagnostic accuracy.
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- All enrolled participants will undergo a single, non-invasive measurement with the NIMBLE System prior to their scheduled invasive coronary angiography. No randomization or comparison groups are included. A subset of 30 participants will also undergo optical coherence tomography (OCT) to provide additional reference data. Usability and safety assessments will be conducted based on operator and patient feedback.
| Arm | Type | Receives |
|---|---|---|
| Experimental | Experimental | Diagnostic Test: NIMBLE testPatients undergoing NIMBLE System measurement prior to coronary angiography |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Prior implantation of one or more coronary stents
- Clinical symptoms suggestive of stent failure (e.g., chest pain, ischemic ECG changes)
- Undergoing scheduled coronary angiography
- Informed consent provided
Key exclusion criteria (4 listed)
- Pregnancy
- Implanted electronic devices (e.g., pacemakers) that may interfere with MWI
- Inability to provide consent
- Chest conditions preventing correct positioning of the device
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| NIMBLE testNon-invasive assessment of ISR with the NIMBLE System (Microwave Interferometry) | Diagnostic test | Experimental |
Primary outcome
Feasibility
Time frame: prior angiography
Feasibility will be assessed by the proportion of enrolled patients in whom the NIMBLE System measurement can be successfully completed and a usable diagnostic output is obtained.
Safety
Time frame: 7 days after Nimble test
Absence of device-related adverse events
2 secondary outcomes
Performance
Time frame: DWithin 24 hours before invasive coronary angiography (single time point assessment)
Usability
Time frame: User (operator) questionnaire will be administered immediately after the NIMBLE System measurement in the first and last enrolled patients. Patient questionnaire will be administered to every participant immediately after their NIMBLE measurement, on the
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 13 May 2025.
- NIMBLE Diagnostics webpageLink provided by the sponsor.
- Individual participant dataSharing planned: No
Related trials for In-stent Restenosis
Active, not recruitingPhase 3
A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis (ISR) - Long Lesion Cohort
In-Stent Restenosis
Active, not recruitingPhase 3
A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis (ISR)
In-Stent Restenosis
Not yet recruitingObservational study
Drug-coated Balloons Versus Drug-eluting Stents for the Treatment of Femoropopliteal In-Stent Restenosis
Femoropopliteal In-Stent Restenosis (ISR)
Not yet recruitingObservational study
The ReCAna for Lower ExtremIty Venous OBstructions and In-StEnt Restenosis Registry
Chronic Venous Disease, Chronic Venous Insufficiency, CVI
Recruiting
Virtue® SAB in the Treatment of Coronary ISR Trial
Coronary Artery Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Hospital Universitari Germans Trias i Pujol
Badalona, Spain
Oriol Rodriguez-Leor, MD, PhD principal investigator
Germans Trias i Pujol Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 1/2 study testing NIMBLE test in people with In-stent Restenosis and Stent Fracture, run by Nimble Diagnostics S.L. at 1 site in Spain.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 13 May 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this combined phase mean?
Phase 1 studies test a treatment in a small group of people for the first time or in a new way, mainly to check safety and find the right dose.
Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Each site lists its own contact: choose the nearest one under Trial locations. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Feasibility (time frame: prior angiography). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 May 2025.