Clinical trials: Stent Fracture
Mandibular Angle Fracture
Evaluation of Patient-specific Surgical Stents and Plates for Guided Reduction And Fixation of Mandibular Angle Fractures
This study will evaluate the patient specific surgical stent and plate for guided reduction and fixation of mandibular angle fractures.
- Trial name
- NCT07375030
- Testing
- Patient specific surgical stents and plates for guided reduction and fixation of mandibular angle fixation, fracture reduction performed using conventional intraoperative manual techniques without a reduction guide.
- Where
- Egypt
- Volunteers
- 14 people
- Sponsor
- Alexandria University
Vascular Complications
Retrospective Analysis of Balloon Expandable Covered Stenting in the Common Femoral Artery
The aim of this study is to evaluate the safety and efficacy of balloon expandable covered stenting of access complications, stenoses or pseudoaneurysms of the common femoral access.
- Trial name
- BEST-CFA (NCT05220540)
- Where
- 3 sites in Hungary
- Volunteers
- 24 people
- Sponsor
- Semmelweis University Heart and Vascular Center
BKP, Osteoporotic Vertebral Compression Fracture
Randomized Controlled Trial of Internal Fixation Reconstruction With Stent Screw in the Treatment of Kummell's Disease
This study is a multicenter, prospective, double-blind, randomized controlled trial using a parallel two-arm design to investigate whether the postoperative 6-month quality of life, vertebral stability, complication of patients…
- Conditions
- BKP, Osteoporotic Vertebral Compression Fracture, Kummell's Disease, Stent-screw-assisted Internal Fixation
- Trial name
- NCT06093087
- Testing
- SAIF, BKP
- Volunteers
- 70 people
- Sponsor
- Second Affiliated Hospital, Zhejiang University, School of Medicine
Mandibular Fractures
Precision of Patient Specific 3D Printed Occlusal Stent, Surgical Guide, and Patient Specific Titanium Plates in Management of Mandibular Fracture (Case Series)
This study evaluates the accuracy of preoperative fully computerized occlusal stents, surgical guide, and patient-specific titanium plates in guided mandibular fracture reduction and fixation.
- Trial name
- NCT07499726
- Testing
- Patient-Specific 3D Printed Occlusal Stent, Surgical Guide, and Titanium Plates
- Where
- Egypt
- Volunteers
- 6 people
- Sponsor
- Cairo University
Durability of Implanted Intravascular Stents, Hemodynamic Effect of Implanted Intravascular Stents
Intravascular Stents Fracture Effects
The goal of the study is to evaluate long term durability and hemodynamic effect of implanted stents in the aortic arch and in pulmonary artery branches.
- Trial name
- NCT01382381
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Rambam Health Care Campus
Peripheral Vascular Diseases
ASSESS Study: Evaluation of ABSOLUTE™ Stent System for Occluded Arteries
The purpose of this study is to investigate the performance of the ABSOLUTE™ .035 peripheral self-expanding stent system in preventing restenosis of occluded or stenotic superficial femoral or proximal popliteal arteries.
- Trial name
- NCT00180505
- Testing
- ABSOLUTE™: Self-Expandable Peripheral Nitinol Stent
- Where
- 13 sites in Austria, Belgium and 5 more
- Volunteers
- 120 people
- Sponsor
- Abbott Medical Devices
Fracture of Stent of Coronary Artery, External Causes of Morbidity and Mortality
Novara Registry of Platinum-Chromium Platform Stents
Recent reports have described cases of novel thin-strut coronary stent longitudinal deformation during or after deployment and a biomechanical analysis have suggested increased susceptibility for such a complication for the…
- Conditions
- Fracture of Stent of Coronary Artery, External Causes of Morbidity and Mortality, Myocardial Infarction, Coronary Vessel Disorders
- Trial name
- PROMETEUS (NCT01759719)
- Testing
- coronary angioplasty with PtCr stent implantation
- Where
- Italy
- Volunteers
- 500 people
- Sponsor
- Azienda Ospedaliero Universitaria Maggiore della Carita
In-stent Restenosis, Stent Fracture
Pilot Study of the α Prototype NIMBLE System: Feasibility, Safety, and Initial Performance in Non-Invasive Detection of Coronary In-Stent Restenosis
The NIMBLE-I study is a prospective, unicentric, single arm, feasibility clinical trial designed to evaluate a novel medical device for the non-invasive monitoring of coronary stents.
- Conditions
- In-stent Restenosis, Stent Fracture, Stent Complication
- Trial name
- NIMBLE-I (NCT06968858)
- Testing
- NIMBLE test
- Where
- Spain
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Nimble Diagnostics S.L.
Minimally Displaced Mandibular Angle Fracture
Fracture Gap After Herbert Screw Insertion by 3d Stents Vs Titanium Plate(Minimally Displaced Mandibular Angle Fracture)
interfragmentary gap measurement using Herbert cannulated headless screw using a 3D surgical customized template versus titanuim plate
- Trial name
- NCT03692260
- Testing
- 3D stent in Herbert screw insertion vs titanium plate
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Cairo University
Unstable Osteoporotic Vertebral Compression Fractures
RCT on the Efficacy and Safety of Minimally Invasive SAIF Technique vs Spinal Fixation in Unstable Osteoporotic Vertebral Fractures
Osteoporotic vertebral fractures (OVF) represent a significant cause of morbidity, mortality, decreased level of function and quality of life.
- Trial name
- SAIF (NCT07071870)
- Testing
- Stent-screw Assisted Internal Fixation (SAIF), Surgical stabilization
- Where
- Switzerland
- Volunteers
- 140 people
- Sponsor
- Eva Koetsier MD PhD
Vertebral Body Fractures
Study on the Treatment of Osteoporotic Vertebral Fractures Using Vertebral Body Stenting
This is a randomized, controlled study to document and evaluate the clinical performance of the Vertebral Body Stenting (VBS) System in osteoporotic fractures of the thoracic and lumbar spine.
- Trial name
- NCT01847898
- Testing
- Vertebral Body Stenting (VBS), Balloon Kyphoplasty
- Where
- 5 sites in Austria, Germany
- Volunteers
- 100 people
- Sponsor
- Synthes GmbH