Sick Sinus SyndromeNCT07078487
Effect of Paced HR on Central BP
A study testing Pacemaker and defibrillator in people with Sick Sinus Syndrome and Hypertension, run by University of Tartu at 1 site in Estonia.
Trial summary
Central (aortic) blood pressure predicts heart, brain and kidney complications more reliably than the usual peripherally measured blood pressure. Heart rate has a strong and sometimes counter-intuitive influence on central blood pressure. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Sick Sinus Syndrome, Hypertension
- What is being tested?
- Pacemaker and defibrillator
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 22 participants
- Where
- 1 siteEstonia
- Study dates
- 21 Sep 2020to 10 Sep 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age 18-80 years.
- Dual-chamber pacemaker implanted ≥3 months for SSS.
- Sinus rhythm; atrial pacing >80%, ventricular pacing <3% since last device check.
- Medication-treated primary hypertension with clinic BP < 140/90 mmHg and home BP < 135/85 mmHg.
- Able to provide informed consent and comply with procedures.
Who cannot join
- Significant AV block, paced QRS ≥ 130 ms, >3 antihypertensives, digoxin or class Ic/III/IV antiarrhythmics, frequent atrial tachyarrhythmia (>3% AMS episodes), coronary intervention on >1 vessel, LVEF ≤ 40%, CRT or ICD, significant valvular disease, congenital heart disease, BMI ≥ 35 kg/m², diabetes with complications or on insulin, advanced renal, hepatic or pulmonary disease, systemic inflammatory disease, malignancy under recent active therapy, pregnancy or lactation, substance misuse, or inability to complete follow-up.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Implications of Paced Heart Rate on Central Blood Pressure in Sick Sinus Syndrome Patients With Hypertension: a Randomised Crossover Study
Central (aortic) blood pressure predicts heart, brain and kidney complications more reliably than the usual peripherally measured blood pressure. Heart rate has a strong and sometimes counter-intuitive influence on central blood pressure. Pacemakers implanted due to sick sinus syndrome (SSS) are typically programmed anywhere between 55-75 beats per minute (bpm), yet it is unclear which rate gives hypertensive pacemaker recipients the most favourable central hemodynamics.
This single-center, randomized, single-blind, two-period cross-over trial will enrol 20 adults (18-80 years) who already carry a dual-chamber pacemaker for SSS, are in sinus rhythm, and have medication-controlled arterial hypertension. Each participant will complete two eight-week pacing periods in random order:
Read more
- "Slow" period - pacemaker lower-rate set to 55 bpm.
- "Fast" period - pacemaker lower-rate set to 75 bpm.
A two-week wash-out at the device's usual settings separates the periods. At baseline and after each intervention the team will perform non-invasive pulse-wave analysis (SphygmoCor XCEL) to obtain central systolic blood pressure (primary endpoint) and arterial stiffness indices such as augmentation index and pulse-wave velocity (secondary endpoints). Pacemaker function, symptoms and safety events are reviewed at every visit; settings can be adjusted by ±5 bpm if troublesome symptoms occur.
The study will provide the first long-term evidence on how fixed pacing rates modulate central blood pressure in real-world SSS patients with hypertension, potentially guiding clinicians toward the optimal programming strategy.
Read the detailed description
Scientific background and rationale Arterial hypertension remains the leading modifiable contributor to cardiovascular morbidity. Unlike brachial pressure, central (aortic) systolic pressure directly loads the left ventricle and cerebral and renal arteries. Epidemiological data show that central pressure is more closely associated with left-ventricular hypertrophy, carotid atherosclerosis and clinical events than peripheral pressure. Heart rate (HR) alters the timing of pulse-wave reflections and can therefore change central pressure in ways that are not apparent from arm-cuff readings.
Pharmacological HR reduction (e.g., ivabradine) has been shown to raise central systolic pressure even while lowering brachial pressure, whereas β-blockers exert mixed HR-dependent and HR-independent effects. In acute pacing studies, lowering HR from 80 bpm to ~60 bpm reduced brachial pressure but left central pressure unchanged; allowing HR to fall to ~50 bpm sometimes lowered or sometimes raised central pressure depending on study design. No prospective trial has tested whether a chronically lower versus higher pacemaker rate produces a durable difference in central hemodynamics in patients who require pacing for SSS.
Objectives Primary: Compare clinic-measured central systolic blood pressure after 8 weeks of pacing at 55 bpm versus 75 bpm.
Secondary: Compare additional central hemodynamic indices (augmentation index, pulse pressure amplification, carotid-femoral pulse-wave velocity), brachial blood pressure, and frequency of pacing-related symptoms and atrial arrhythmias between the two settings.
Study design
- Single-center, randomized, single-blind, cross-over.
- Two 8-week intervention periods separated by a 2-week wash-out.
- Allocation ratio 1:1, block randomization, concealed in sequentially numbered opaque envelopes prepared by an independent statistician.
Visit schedule
T-2 (pre-screen) → T-1 (final screen + baseline PWA) → T0 (randomization) → T1 (programming of first rate) → 8 weeks → F1 (end-of-period assessments, device reset) → 2-week wash-out → T2 (second baseline) → program second rate → 8 weeks → F2 (final assessments, device returned to pre-study settings). Total participation ≈20 weeks.
Participants Inclusion
- Age 18-80 years.
- Dual-chamber pacemaker implanted ≥3 months for SSS.
- Sinus rhythm; atrial pacing >80%, ventricular pacing <3% since last device check.
- Medication-treated primary hypertension with clinic BP < 140/90 mmHg and home BP < 135/85 mmHg.
- Able to provide informed consent and comply with procedures. Exclusion (abridged)
- Significant AV block, paced QRS ≥ 130 ms, >3 antihypertensives, digoxin or class Ic/III/IV antiarrhythmics, frequent atrial tachyarrhythmia (>3% AMS episodes), coronary intervention on >1 vessel, LVEF ≤ 40%, CRT or ICD, significant valvular disease, congenital heart disease, BMI ≥ 35 kg/m², diabetes with complications or on insulin, advanced renal, hepatic or pulmonary disease, systemic inflammatory disease, malignancy under recent active therapy, pregnancy or lactation, substance misuse, or inability to complete follow-up.
Interventions Pacemaker lower-rate limit is set to either 55 bpm or 75 bpm using a Merlin™ Patient Care programmer (Abbott/St Jude Medical). All other device parameters remain unchanged unless clinically indicated. If intolerable palpitations, dizziness or dyspnoea occur, HR may be adjusted by ±5 bpm within protocol limits; the participant may continue.
Sample size and statistics The initial 20-patient cohort (2020-2022) showed a within-person SD of 5 mmHg for central systolic BP. Detecting a 3 mmHg difference with 80% power at α = 0.05 in a cross-over design requires 38 completed participants; 20 additional individuals will therefore be recruited (total = 40) to allow for 5% attrition. Analysis will follow an intention-to-treat principle.
Data collection methods
Pulse-wave analysis: SphygmoCor XCEL (AtCor Medical) brachial cuff acquisition with generalized transfer function yields central waveforms. Carotid-femoral pulse-wave velocity is obtained by simultaneous carotid tonometry and femoral cuff recording with surface tape measurement of path length. Standardized seated brachial BP is averaged from triplicate readings. Home BP is logged using a validated oscillometric device. Device diagnostics supply pacing percentages and arrhythmia burden.
Safety, monitoring and ethics All procedures mirror routine pacemaker follow-up except for deliberate lower-rate reprogramming, which falls within the accepted clinical range (55-75 bpm). The prior 20-participant phase recorded two episodes of atrial fibrillation requiring treatment and no serious device malfunctions. Adverse events will be reported to the ethics committee within 15 days. The study complies with the Declaration of Helsinki, EU GDPR and ICH-GCP. Data are pseudonymised; records are stored on secure servers for 10 years, after which they are destroyed. The University of Tartu Human Research Ethics Committee has approved the protocol (initial approval 299/T-22, renewed 2025).
Dissemination Results will be submitted to a peer-reviewed cardiovascular journal, presented at international cardiology conferences.
- Conditions
- Sick Sinus Syndrome, Hypertension
- Being tested
- Pacemaker and defibrillator
- Keywords
- heart rate, hypertension, sick sinus syndrome, arterial pressure, pulse wave analysis
- Medical subject headings
- Sick Sinus Syndrome, Hypertension
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Pacemaker and defibrillatorDevice
Setting the pacemaker base rate at a pre-defined base rate
| Study group | Role | What they receive |
|---|---|---|
| "Slow" arm | Experimental | Pacemaker base rate set at 55 bpm Receives: Device: Pacemaker and defibrillator |
| "Fast" arm | Experimental | Pacemaker base rate set at 75 bpm Receives: Device: Pacemaker and defibrillator |
What is being measured
The primary outcome is the main question the study is designed to answer.
Central systolic blood pressure
Central (aortic) systolic blood pressure measured non-invasively using pulse wave analysis (SphygmoCor XCEL) with brachial cuff acquisition and generalized transfer function to derive central waveforms. Measurements taken in standardized seated position in clinical setting.
Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)
Secondary outcomes (5)
Central diastolic blood pressure
Central (aortic) diastolic blood pressure measured non-invasively using pulse wave analysis (SphygmoCor XCEL) with brachial cuff acquisition and generalized transfer function to derive central waveforms.
Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)
Augmentation index
Augmentation index derived from central pulse wave analysis measuring the contribution of reflected waves to central systolic pressure, expressed as percentage increase in central systolic pressure due to wave reflection.
Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)
Pulse wave velocity
Carotid-femoral pulse wave velocity measured using simultaneous carotid tonometry and femoral cuff recording with surface measurement of path length, indicating arterial stiffness.
Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)
Brachial blood pressure
Peripheral (brachial) systolic and diastolic blood pressure measured using standardized seated position with triplicate readings averaged, measured using validated oscillometric device.
Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)
Pulse pressure amplification
Ratio of peripheral to central pulse pressure derived from non-invasive pulse wave analysis (SphygmoCor XCEL), reflecting amplification of the pressure wave between the aorta and brachial artery.
Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted22 Jul 2025
- Study start21 Sep 2020
- Primary completion10 Sep 2024
- Study completion10 Sep 2024
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for Sick Sinus SyndromeStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 22 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Tartu
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Priit Kampus, University of Tartu
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07078487
- Sponsor's protocol ID
- 299/T-22
- Status last verified
- Jul 2025
- First submitted
- 11 Jul 2025
- Last updated
- 22 Jul 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Publications
Hashimoto J. Pulse pressure amplification as a hemodynamic predictor of cardiovascular disease. Hypertens Res. 2024 Nov;47(11):3270-3272. doi: 10.1038/s41440-024-01880-8. Epub 2024 Sep 11. No abstract available.
PubMed 39261706Fong DT, Yam KY, Chu VW, Cheung RT, Chan KM. Upper limb muscle fatigue during prolonged Boccia games with underarm throwing technique. Sports Biomech. 2012 Nov;11(4):441-51. doi: 10.1080/14763141.2012.699977.
PubMed 23259234Ikeda S, Shinohara K, Enzan N, Matsushima S, Tohyama T, Funakoshi K, Kishimoto J, Itoh H, Komuro I, Tsutsui H. A higher resting heart rate is associated with cardiovascular event risk in patients with type 2 diabetes mellitus without known cardiovascular disease. Hypertens Res. 2023 May;46(5):1090-1099. doi: 10.1038/s41440-023-01178-1. Epub 2023 Jan 27.
PubMed 36707715Fox K, Borer JS, Camm AJ, Danchin N, Ferrari R, Lopez Sendon JL, Steg PG, Tardif JC, Tavazzi L, Tendera M; Heart Rate Working Group. Resting heart rate in cardiovascular disease. J Am Coll Cardiol. 2007 Aug 28;50(9):823-30. doi: 10.1016/j.jacc.2007.04.079. Epub 2007 Aug 13.
PubMed 17719466
Study at a glance
From the registry record, last updated by the sponsor on 22 Jul 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Implications of Paced Heart Rate on Central Blood Pressure in Sick Sinus Syndrome Patients With Hypertension: a Randomised Crossover Study
- ClinicalTrials.gov ID
- NCT07078487
- Acronym / sponsor ID
- 299/T-22
- Conditions
- Sick Sinus Syndrome, Hypertension
- Keywords
- heart rate, hypertension, sick sinus syndrome, arterial pressure, pulse wave analysis
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 22 participants (actual)
- Lead sponsor
- University of TartuUniversity, hospital or other
- Study start
- 21 Sep 2020 (actual)
- Primary completion
- 10 Sep 2024 (actual)
- Study completion
- 10 Sep 2024 (actual)
- First posted
- 22 Jul 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Central (aortic) blood pressure predicts heart, brain and kidney complications more reliably than the usual peripherally measured blood pressure. Heart rate has a strong and sometimes counter-intuitive influence on central blood pressure. Pacemakers implanted due to sick sinus syndrome (SSS) are typically programmed anywhere between 55-75 beats per minute (bpm), yet it is unclear which rate gives hypertensive pacemaker recipients the most favourable central hemodynamics.
This single-center, randomized, single-blind, two-period cross-over trial will enrol 20 adults (18-80 years) who already carry a dual-chamber pacemaker for SSS, are in sinus rhythm, and have medication-controlled arterial hypertension. Each participant will complete two eight-week pacing periods in random order:
- "Slow" period - pacemaker lower-rate set to 55 bpm.
- "Fast" period - pacemaker lower-rate set to 75 bpm.
A two-week wash-out at the device's usual settings separates the periods. At baseline and after each intervention the team will perform non-invasive pulse-wave analysis (SphygmoCor XCEL) to obtain central systolic blood pressure (primary endpoint) and arterial stiffness indices such as augmentation index and pulse-wave velocity (secondary endpoints). Pacemaker function, symptoms and safety events are reviewed at every visit; settings can be adjusted by ±5 bpm if troublesome symptoms occur.
The study will provide the first long-term evidence on how fixed pacing rates modulate central blood pressure in real-world SSS patients with hypertension, potentially guiding clinicians toward the optimal programming strategy.
Detailed description
Scientific background and rationale Arterial hypertension remains the leading modifiable contributor to cardiovascular morbidity. Unlike brachial pressure, central (aortic) systolic pressure directly loads the left ventricle and cerebral and renal arteries. Epidemiological data show that central pressure is more closely associated with left-ventricular hypertrophy, carotid atherosclerosis and clinical events than peripheral pressure. Heart rate (HR) alters the timing of pulse-wave reflections and can therefore change central pressure in ways that are not apparent from arm-cuff readings.
Pharmacological HR reduction (e.g., ivabradine) has been shown to raise central systolic pressure even while lowering brachial pressure, whereas β-blockers exert mixed HR-dependent and HR-independent effects. In acute pacing studies, lowering HR from 80 bpm to ~60 bpm reduced brachial pressure but left central pressure unchanged; allowing HR to fall to ~50 bpm sometimes lowered or sometimes raised central pressure depending on study design. No prospective trial has tested whether a chronically lower versus higher pacemaker rate produces a durable difference in central hemodynamics in patients who require pacing for SSS.
Objectives Primary: Compare clinic-measured central systolic blood pressure after 8 weeks of pacing at 55 bpm versus 75 bpm.
Secondary: Compare additional central hemodynamic indices (augmentation index, pulse pressure amplification, carotid-femoral pulse-wave velocity), brachial blood pressure, and frequency of pacing-related symptoms and atrial arrhythmias between the two settings.
Study design
- Single-center, randomized, single-blind, cross-over.
- Two 8-week intervention periods separated by a 2-week wash-out.
- Allocation ratio 1:1, block randomization, concealed in sequentially numbered opaque envelopes prepared by an independent statistician.
Visit schedule
T-2 (pre-screen) → T-1 (final screen + baseline PWA) → T0 (randomization) → T1 (programming of first rate) → 8 weeks → F1 (end-of-period assessments, device reset) → 2-week wash-out → T2 (second baseline) → program second rate → 8 weeks → F2 (final assessments, device returned to pre-study settings). Total participation ≈20 weeks.
Participants Inclusion
- Age 18-80 years.
- Dual-chamber pacemaker implanted ≥3 months for SSS.
- Sinus rhythm; atrial pacing >80%, ventricular pacing <3% since last device check.
- Medication-treated primary hypertension with clinic BP < 140/90 mmHg and home BP < 135/85 mmHg.
- Able to provide informed consent and comply with procedures. Exclusion (abridged)
- Significant AV block, paced QRS ≥ 130 ms, >3 antihypertensives, digoxin or class Ic/III/IV antiarrhythmics, frequent atrial tachyarrhythmia (>3% AMS episodes), coronary intervention on >1 vessel, LVEF ≤ 40%, CRT or ICD, significant valvular disease, congenital heart disease, BMI ≥ 35 kg/m², diabetes with complications or on insulin, advanced renal, hepatic or pulmonary disease, systemic inflammatory disease, malignancy under recent active therapy, pregnancy or lactation, substance misuse, or inability to complete follow-up.
Interventions Pacemaker lower-rate limit is set to either 55 bpm or 75 bpm using a Merlin™ Patient Care programmer (Abbott/St Jude Medical). All other device parameters remain unchanged unless clinically indicated. If intolerable palpitations, dizziness or dyspnoea occur, HR may be adjusted by ±5 bpm within protocol limits; the participant may continue.
Sample size and statistics The initial 20-patient cohort (2020-2022) showed a within-person SD of 5 mmHg for central systolic BP. Detecting a 3 mmHg difference with 80% power at α = 0.05 in a cross-over design requires 38 completed participants; 20 additional individuals will therefore be recruited (total = 40) to allow for 5% attrition. Analysis will follow an intention-to-treat principle.
Data collection methods
Pulse-wave analysis: SphygmoCor XCEL (AtCor Medical) brachial cuff acquisition with generalized transfer function yields central waveforms. Carotid-femoral pulse-wave velocity is obtained by simultaneous carotid tonometry and femoral cuff recording with surface tape measurement of path length. Standardized seated brachial BP is averaged from triplicate readings. Home BP is logged using a validated oscillometric device. Device diagnostics supply pacing percentages and arrhythmia burden.
Safety, monitoring and ethics All procedures mirror routine pacemaker follow-up except for deliberate lower-rate reprogramming, which falls within the accepted clinical range (55-75 bpm). The prior 20-participant phase recorded two episodes of atrial fibrillation requiring treatment and no serious device malfunctions. Adverse events will be reported to the ethics committee within 15 days. The study complies with the Declaration of Helsinki, EU GDPR and ICH-GCP. Data are pseudonymised; records are stored on secure servers for 10 years, after which they are destroyed. The University of Tartu Human Research Ethics Committee has approved the protocol (initial approval 299/T-22, renewed 2025).
Dissemination Results will be submitted to a peer-reviewed cardiovascular journal, presented at international cardiology conferences.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| "Slow" arm | Experimental | Device: Pacemaker and defibrillatorPacemaker base rate set at 55 bpm |
| "Fast" arm | Experimental | Device: Pacemaker and defibrillatorPacemaker base rate set at 75 bpm |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Age 18-80 years.
- Dual-chamber pacemaker implanted ≥3 months for SSS.
- Sinus rhythm; atrial pacing >80%, ventricular pacing <3% since last device check.
- Medication-treated primary hypertension with clinic BP < 140/90 mmHg and home BP < 135/85 mmHg.
- Able to provide informed consent and comply with procedures.
Key exclusion criteria (1 listed)
- Significant AV block, paced QRS ≥ 130 ms, >3 antihypertensives, digoxin or class Ic/III/IV antiarrhythmics, frequent atrial tachyarrhythmia (>3% AMS episodes), coronary intervention on >1 vessel, LVEF ≤ 40%, CRT or ICD, significant valvular disease, congenital heart disease, BMI ≥ 35 kg/m², diabetes with complications or on insulin, advanced renal, hepatic or pulmonary disease, systemic inflammatory disease, malignancy under recent active therapy, pregnancy or lactation, substance misuse, or inability to complete follow-up.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Pacemaker and defibrillatorSetting the pacemaker base rate at a pre-defined base rate | Device | "Fast" arm, "Slow" arm |
Primary outcome
Central systolic blood pressure
Time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)
Central (aortic) systolic blood pressure measured non-invasively using pulse wave analysis (SphygmoCor XCEL) with brachial cuff acquisition and generalized transfer function to derive central waveforms. Measurements taken in standardized seated position in clinical setting.
5 secondary outcomes
Central diastolic blood pressure
Time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)
Augmentation index
Time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)
Pulse wave velocity
Time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)
Brachial blood pressure
Time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)
Pulse pressure amplification
Time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 22 Jul 2025.
- Background: PubMed 39261706Hashimoto J. Pulse pressure amplification as a hemodynamic predictor of cardiovascular disease. Hypertens Res. 2024 Nov;47(11):3270-3272. doi: 10.1038/s41440-024-01880-8. Epub 2024 Sep 11. No abstract available.
- Background: PubMed 23259234Fong DT, Yam KY, Chu VW, Cheung RT, Chan KM. Upper limb muscle fatigue during prolonged Boccia games with underarm throwing technique. Sports Biomech. 2012 Nov;11(4):441-51. doi: 10.1080/14763141.2012.699977.
- Background: PubMed 36707715Ikeda S, Shinohara K, Enzan N, Matsushima S, Tohyama T, Funakoshi K, Kishimoto J, Itoh H, Komuro I, Tsutsui H. A higher resting heart rate is associated with cardiovascular event risk in patients with type 2 diabetes mellitus without known cardiovascular disease. Hypertens Res. 2023 May;46(5):1090-1099. doi: 10.1038/s41440-023-01178-1. Epub 2023 Jan 27.
- Background: PubMed 17719466Fox K, Borer JS, Camm AJ, Danchin N, Ferrari R, Lopez Sendon JL, Steg PG, Tardif JC, Tavazzi L, Tendera M; Heart Rate Working Group. Resting heart rate in cardiovascular disease. J Am Coll Cardiol. 2007 Aug 28;50(9):823-30. doi: 10.1016/j.jacc.2007.04.079. Epub 2007 Aug 13.
- Individual participant dataSharing planned: Undecided
Related trials for Sick Sinus Syndrome
Recruiting
Multimodality Location Prediction Accuracy of Leadless Pacemaker Positioning
Sinus Pause, Sinus Sick Syndrome
Active, not recruitingObservational study
Safety, Performance, and Clinical Benefit of Pacing the Left Bundle Branch Area - Post-Market Clinical Follow-up
Bradycardia, Atrioventricular Block
Not yet recruiting
Belgo-Luxembourg Leadless PM Registry
Bradyarrhythmias, AV Block Complete
Recruiting
LEAP 2 Chronic EFS
Cardiac Pacemaker, Cardiac Rhythm Disorder
RecruitingObservational study
Biospecimen Repository for Cardiac Arrhythmias at the Cleveland Clinic
Arrhythmias, Cardiac
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Pacemaker and defibrillator in people with Sick Sinus Syndrome and Hypertension, run by University of Tartu at 1 site in Estonia.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 22 Jul 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Estonia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Central systolic blood pressure (time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07078487, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Jul 2025.