Sick Sinus SyndromeNCT07078487

Effect of Paced HR on Central BP

A study testing Pacemaker and defibrillator in people with Sick Sinus Syndrome and Hypertension, run by University of Tartu at 1 site in Estonia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Central (aortic) blood pressure predicts heart, brain and kidney complications more reliably than the usual peripherally measured blood pressure. Heart rate has a strong and sometimes counter-intuitive influence on central blood pressure. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Sick Sinus Syndrome, Hypertension
What is being tested?
Pacemaker and defibrillator
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
22 participants
Where
1 siteEstonia
Study dates
21 Sep 2020to 10 Sep 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age 18-80 years.
  • Dual-chamber pacemaker implanted ≥3 months for SSS.
  • Sinus rhythm; atrial pacing >80%, ventricular pacing <3% since last device check.
  • Medication-treated primary hypertension with clinic BP < 140/90 mmHg and home BP < 135/85 mmHg.
  • Able to provide informed consent and comply with procedures.

Who cannot join

  • Significant AV block, paced QRS ≥ 130 ms, >3 antihypertensives, digoxin or class Ic/III/IV antiarrhythmics, frequent atrial tachyarrhythmia (>3% AMS episodes), coronary intervention on >1 vessel, LVEF ≤ 40%, CRT or ICD, significant valvular disease, congenital heart disease, BMI ≥ 35 kg/m², diabetes with complications or on insulin, advanced renal, hepatic or pulmonary disease, systemic inflammatory disease, malignancy under recent active therapy, pregnancy or lactation, substance misuse, or inability to complete follow-up.

Trial locations and contacts

1 site in 1 country.

Estonia1 site
  • North Estonia Medical Centre

    Tallinn, Harju, 13419

Other trials in Estonia

About this study

Official title: Implications of Paced Heart Rate on Central Blood Pressure in Sick Sinus Syndrome Patients With Hypertension: a Randomised Crossover Study

Central (aortic) blood pressure predicts heart, brain and kidney complications more reliably than the usual peripherally measured blood pressure. Heart rate has a strong and sometimes counter-intuitive influence on central blood pressure. Pacemakers implanted due to sick sinus syndrome (SSS) are typically programmed anywhere between 55-75 beats per minute (bpm), yet it is unclear which rate gives hypertensive pacemaker recipients the most favourable central hemodynamics.

This single-center, randomized, single-blind, two-period cross-over trial will enrol 20 adults (18-80 years) who already carry a dual-chamber pacemaker for SSS, are in sinus rhythm, and have medication-controlled arterial hypertension. Each participant will complete two eight-week pacing periods in random order:

Read more
  • "Slow" period - pacemaker lower-rate set to 55 bpm.
  • "Fast" period - pacemaker lower-rate set to 75 bpm.

A two-week wash-out at the device's usual settings separates the periods. At baseline and after each intervention the team will perform non-invasive pulse-wave analysis (SphygmoCor XCEL) to obtain central systolic blood pressure (primary endpoint) and arterial stiffness indices such as augmentation index and pulse-wave velocity (secondary endpoints). Pacemaker function, symptoms and safety events are reviewed at every visit; settings can be adjusted by ±5 bpm if troublesome symptoms occur.

The study will provide the first long-term evidence on how fixed pacing rates modulate central blood pressure in real-world SSS patients with hypertension, potentially guiding clinicians toward the optimal programming strategy.

Read the detailed description

Scientific background and rationale Arterial hypertension remains the leading modifiable contributor to cardiovascular morbidity. Unlike brachial pressure, central (aortic) systolic pressure directly loads the left ventricle and cerebral and renal arteries. Epidemiological data show that central pressure is more closely associated with left-ventricular hypertrophy, carotid atherosclerosis and clinical events than peripheral pressure. Heart rate (HR) alters the timing of pulse-wave reflections and can therefore change central pressure in ways that are not apparent from arm-cuff readings.

Pharmacological HR reduction (e.g., ivabradine) has been shown to raise central systolic pressure even while lowering brachial pressure, whereas β-blockers exert mixed HR-dependent and HR-independent effects. In acute pacing studies, lowering HR from 80 bpm to ~60 bpm reduced brachial pressure but left central pressure unchanged; allowing HR to fall to ~50 bpm sometimes lowered or sometimes raised central pressure depending on study design. No prospective trial has tested whether a chronically lower versus higher pacemaker rate produces a durable difference in central hemodynamics in patients who require pacing for SSS.

Objectives Primary: Compare clinic-measured central systolic blood pressure after 8 weeks of pacing at 55 bpm versus 75 bpm.

Secondary: Compare additional central hemodynamic indices (augmentation index, pulse pressure amplification, carotid-femoral pulse-wave velocity), brachial blood pressure, and frequency of pacing-related symptoms and atrial arrhythmias between the two settings.

Study design

  • Single-center, randomized, single-blind, cross-over.
  • Two 8-week intervention periods separated by a 2-week wash-out.
  • Allocation ratio 1:1, block randomization, concealed in sequentially numbered opaque envelopes prepared by an independent statistician.

Visit schedule

T-2 (pre-screen) → T-1 (final screen + baseline PWA) → T0 (randomization) → T1 (programming of first rate) → 8 weeks → F1 (end-of-period assessments, device reset) → 2-week wash-out → T2 (second baseline) → program second rate → 8 weeks → F2 (final assessments, device returned to pre-study settings). Total participation ≈20 weeks.

Participants Inclusion

  1. Age 18-80 years.
  2. Dual-chamber pacemaker implanted ≥3 months for SSS.
  3. Sinus rhythm; atrial pacing >80%, ventricular pacing <3% since last device check.
  4. Medication-treated primary hypertension with clinic BP < 140/90 mmHg and home BP < 135/85 mmHg.
  5. Able to provide informed consent and comply with procedures. Exclusion (abridged)
  • Significant AV block, paced QRS ≥ 130 ms, >3 antihypertensives, digoxin or class Ic/III/IV antiarrhythmics, frequent atrial tachyarrhythmia (>3% AMS episodes), coronary intervention on >1 vessel, LVEF ≤ 40%, CRT or ICD, significant valvular disease, congenital heart disease, BMI ≥ 35 kg/m², diabetes with complications or on insulin, advanced renal, hepatic or pulmonary disease, systemic inflammatory disease, malignancy under recent active therapy, pregnancy or lactation, substance misuse, or inability to complete follow-up.

Interventions Pacemaker lower-rate limit is set to either 55 bpm or 75 bpm using a Merlin™ Patient Care programmer (Abbott/St Jude Medical). All other device parameters remain unchanged unless clinically indicated. If intolerable palpitations, dizziness or dyspnoea occur, HR may be adjusted by ±5 bpm within protocol limits; the participant may continue.

Sample size and statistics The initial 20-patient cohort (2020-2022) showed a within-person SD of 5 mmHg for central systolic BP. Detecting a 3 mmHg difference with 80% power at α = 0.05 in a cross-over design requires 38 completed participants; 20 additional individuals will therefore be recruited (total = 40) to allow for 5% attrition. Analysis will follow an intention-to-treat principle.

Data collection methods

Pulse-wave analysis: SphygmoCor XCEL (AtCor Medical) brachial cuff acquisition with generalized transfer function yields central waveforms. Carotid-femoral pulse-wave velocity is obtained by simultaneous carotid tonometry and femoral cuff recording with surface tape measurement of path length. Standardized seated brachial BP is averaged from triplicate readings. Home BP is logged using a validated oscillometric device. Device diagnostics supply pacing percentages and arrhythmia burden.

Safety, monitoring and ethics All procedures mirror routine pacemaker follow-up except for deliberate lower-rate reprogramming, which falls within the accepted clinical range (55-75 bpm). The prior 20-participant phase recorded two episodes of atrial fibrillation requiring treatment and no serious device malfunctions. Adverse events will be reported to the ethics committee within 15 days. The study complies with the Declaration of Helsinki, EU GDPR and ICH-GCP. Data are pseudonymised; records are stored on secure servers for 10 years, after which they are destroyed. The University of Tartu Human Research Ethics Committee has approved the protocol (initial approval 299/T-22, renewed 2025).

Dissemination Results will be submitted to a peer-reviewed cardiovascular journal, presented at international cardiology conferences.

Being tested
Pacemaker and defibrillator
Keywords
heart rate, hypertension, sick sinus syndrome, arterial pressure, pulse wave analysis
Medical subject headings
Sick Sinus Syndrome, Hypertension

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Pacemaker and defibrillatorDevice

    Setting the pacemaker base rate at a pre-defined base rate

Study groups in NCT07078487
Study groupRoleWhat they receive
"Slow" armExperimentalPacemaker base rate set at 55 bpm
Receives: Device: Pacemaker and defibrillator
"Fast" armExperimentalPacemaker base rate set at 75 bpm
Receives: Device: Pacemaker and defibrillator

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Central systolic blood pressure

    Central (aortic) systolic blood pressure measured non-invasively using pulse wave analysis (SphygmoCor XCEL) with brachial cuff acquisition and generalized transfer function to derive central waveforms. Measurements taken in standardized seated position in clinical setting.

    Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)

Secondary outcomes (5)
  1. Central diastolic blood pressure

    Central (aortic) diastolic blood pressure measured non-invasively using pulse wave analysis (SphygmoCor XCEL) with brachial cuff acquisition and generalized transfer function to derive central waveforms.

    Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)

  2. Augmentation index

    Augmentation index derived from central pulse wave analysis measuring the contribution of reflected waves to central systolic pressure, expressed as percentage increase in central systolic pressure due to wave reflection.

    Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)

  3. Pulse wave velocity

    Carotid-femoral pulse wave velocity measured using simultaneous carotid tonometry and femoral cuff recording with surface measurement of path length, indicating arterial stiffness.

    Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)

  4. Brachial blood pressure

    Peripheral (brachial) systolic and diastolic blood pressure measured using standardized seated position with triplicate readings averaged, measured using validated oscillometric device.

    Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)

  5. Pulse pressure amplification

    Ratio of peripheral to central pulse pressure derived from non-invasive pulse wave analysis (SphygmoCor XCEL), reflecting amplification of the pressure wave between the aorta and brachial artery.

    Measured: After each 8-week intervention period (at week 8 and week 18 of study participation)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Jul 2025
  2. Study start21 Sep 2020
  3. Primary completion10 Sep 2024
  4. Study completion10 Sep 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Who is masked
Participant
Enrolment
22 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07078487
Sponsor's protocol ID
299/T-22
Status last verified
Jul 2025
First submitted
11 Jul 2025
Last updated
22 Jul 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Hashimoto J. Pulse pressure amplification as a hemodynamic predictor of cardiovascular disease. Hypertens Res. 2024 Nov;47(11):3270-3272. doi: 10.1038/s41440-024-01880-8. Epub 2024 Sep 11. No abstract available.

    PubMed 39261706
  • Fong DT, Yam KY, Chu VW, Cheung RT, Chan KM. Upper limb muscle fatigue during prolonged Boccia games with underarm throwing technique. Sports Biomech. 2012 Nov;11(4):441-51. doi: 10.1080/14763141.2012.699977.

    PubMed 23259234
  • Ikeda S, Shinohara K, Enzan N, Matsushima S, Tohyama T, Funakoshi K, Kishimoto J, Itoh H, Komuro I, Tsutsui H. A higher resting heart rate is associated with cardiovascular event risk in patients with type 2 diabetes mellitus without known cardiovascular disease. Hypertens Res. 2023 May;46(5):1090-1099. doi: 10.1038/s41440-023-01178-1. Epub 2023 Jan 27.

    PubMed 36707715
  • Fox K, Borer JS, Camm AJ, Danchin N, Ferrari R, Lopez Sendon JL, Steg PG, Tardif JC, Tavazzi L, Tendera M; Heart Rate Working Group. Resting heart rate in cardiovascular disease. J Am Coll Cardiol. 2007 Aug 28;50(9):823-30. doi: 10.1016/j.jacc.2007.04.079. Epub 2007 Aug 13.

    PubMed 17719466

Questions about this trial

What is this clinical trial studying?

A study testing Pacemaker and defibrillator in people with Sick Sinus Syndrome and Hypertension, run by University of Tartu at 1 site in Estonia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Jul 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Estonia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Central systolic blood pressure (time frame: After each 8-week intervention period (at week 8 and week 18 of study participation)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07078487, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Jul 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in