AzTrials
AzTrials

DefibrillatorMCV3930 EFSNCT07811609

Early Feasibility Study of 3930M Defibrillation Lead Implantation Via the Middle Cardiac Vein in Patients With Tricuspid Valve Regurgitation

A study testing Defibrillator in people with Defibrillator and Tricuspid Valve Regurgitation, run by Minneapolis Heart Institute Foundation at 1 site in United States.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record

Search all trials

Trial summary

Prospective, single center, early feasibility study designed to evaluate the initial safety and device performance of the Medtronic 3930M Lead when implanted via the Middle Cardiac Vein in patients with Tricuspid Valve Regurgitation Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Defibrillator, Tricuspid Valve Regurgitation
What is being tested?
Defibrillator
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
5 participants
Where
1 siteUnited States
Study dates
Nov 2026to Jan 2028
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Subject meets current clinical practice guidelines for implantation of ICD or CRT-D and will undergo one of the following:
  • Medtronic CRT-D system implant
  • Medtronic ICD system implant (single or dual chamber)
  • Anatomical suitability for middle cardiac vein lead placement based on pre procedural imaging.
  • Subject meets both of the following:
  • At least Moderate Tricuspid Valve Regurgitation documented by cardiac imaging
Show all 10Show fewer
  • A clinical goal to avoid worsening tricuspid valve regurgitation as determined by the treating physician and/or the patient
  • Age 18 years or older.
  • Subject is willing to undergo implant defibrillation testing
  • Signed Patient Informed Consent Form (ICF).

Who cannot join

  • Life expectancy < 6 months due to non-cardiac comorbidities or advanced frailty where the procedure is not aligned with goals of care
  • Contraindication to transvenous lead implantation, including:
  • Severe or occlusive disease of the axillary/subclavian venous system
  • Coronary sinus or middle cardiac vein occlusion, severe stenosis, or anatomy prohibiting safe lead delivery
  • Known hypercoagulable state or bleeding disorder is not manageable with standard therapy.
  • Subject is contraindicated for ≤1 mg dexamethasone acetate
Show all 26Show fewer
  • Patients with a medical condition that precludes them from undergoing defibrillation testing:
  • Pre-existing or suspected pneumothorax
  • Severe aortic stenosis
  • Current Intracardiac LA or LV thrombus
  • Severe proximal three-vessel or left main coronary artery disease without revascularization
  • Hemodynamic instability
  • Unstable angina
  • Recent stroke or transient ischemic attack (within the last 6 months)
  • Known inadequate external defibrillation
  • LVEDD >70 mm
  • Any other known medical condition not listed that precludes their participation in the opinion of the Investigator.
  • Patient with evidence of active infection or undergoing treatment for an infection.
  • Inability to provide informed consent, including:
  • Cognitive impairment without a legally authorized representative
  • Language or communication barriers that prevent adequate understanding of the study
  • Unable to follow through study protocol for any reasons (social support, distance from research center, insurance denial, mental illness etc.) in the investigator's judgement
  • Pregnant women or breastfeeding women, or women of childbearing potential and who are not on a reliable form of birth regulation method or abstinence
  • End-Stage Renal Disease (ESRD) on dialysis
  • NYHA IV
  • Patient participation in another study that precludes concomitant study participation

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Efrah M Hussein, BS contact

612-863-0666

efrah.hussein@allina.com

Dawn R Witt, PhD contact

612-385-8299

Dawn.Witt@allina.com

United States1 site
  • Minneapolis Heart Institute Foundation

    Minneapolis, Minnesota, 55407

    Efrah M Hussein, BS, 612-863-0666, efrah.hussein@allina.com

    Dawn R Witt, PhD, 612-385-8299, dawn.witt@allina.com

Other trials in United States

About this study

Official title: Early Feasibility Study of Medtronic OmniaSecure Model 3930M Defibrillation Lead Implantation Via the Middle Cardiac Vein in Patients With Tricuspid Valve Regurgitation: MCV3930 EFS

Prospective, single center, early feasibility study designed to evaluate the initial safety and device performance of the Medtronic 3930M Lead when implanted via the Middle Cardiac Vein in patients with Tricuspid Valve Regurgitation

Being tested
Defibrillator
Medical subject headings
Tricuspid Valve Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • DefibrillatorDevice

    Required electrical testing for pacing, sensing, impedance, and defibrillation will be completed

Study groups in NCT07811609
Study groupRoleWhat they receive
InterventionalExperimentalPatients will undergo implant of the Medtronic 3930M Defibrillation lead via the Middle Cardiac Vein and undergo required electrical testing
Receives: Device: Defibrillator

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Acute Procedural Success

    Acute Procedural Success, defined as successful implantation of the investigational lead with all the following:

    1. Successful lead delivery and deployment at the intended MCV location within 4 deployment attempts
    2. Stable lead position at completion of the procedure
    3. Acceptable electrical performance:
    • Capture threshold: ≤ 2.0 V at 0.4 ms
    • Sensing amplitude: ≥ 4.0 mV
    • Impedance: 200-1500 Ω
    1. No device- or procedure-related Major Adverse Cardiovascular Events (MACE) through hospital discharge
    2. Absence of T-wave Oversensing (TWOS)
    3. Absence of P-wave Oversensing (PWOS)
    4. Absence of Myopotential Oversensing
    5. Successful Defibrillation Test (DFT) with 10J safety margin
    6. Absence of any serious adverse events related to the MCV implantation site.

    Measured: Index Procedure

Secondary outcomes (3)
  1. Lead Electrical Performance and Stability through 90 Days

    Evaluation of MCV lead electrical performance and stability through 90 days following implantation, including:

    • Stability of electrical performance (e.g., pacing threshold, sensing, impedance)
    • Lead stability (e.g., no dislodgement or migration)
    • Need for lead revision or system modification

    Measured: Up to 90 days following implant

  2. Incidence of Device- or Procedure-Related Complications

    Number of participants experiencing device- or procedure-related complications through 90 days following implantation:

    1. Incidence of device- or procedure-related major adverse events including, but not limited to:
    • Death (all-cause or procedure-related)
    • Cardiac perforation, pericardial effusion, or cardiac tamponade
    • Clinically significant arrhythmia requiring intervention
    • Device-related infection requiring intervention
    • Lead dislodgement requiring intervention
    • Coronary sinus or venous injury
    • Clinically significant phrenic nerve stimulation
    • System revision or extraction

    Measured: Up to 90 days following implant

  3. Freedom from Device-or Procedure-Related Serious Adverse Events

    Proportion of participants free from device-or procedure-related serious adverse events through 90 days following implantation.

    Measured: Up to 90 days following implant

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Sep 2026
  2. Study startNov 2026 (estimated)
  3. Primary completionJan 2028 (estimated)
  4. Study completionJan 2028 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
5 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07811609
Sponsor's protocol ID
MCV 3930
Acronym
MCV3930 EFS
Status last verified
Sep 2026
First submitted
27 Aug 2026
Last updated
10 Sep 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in