AzTrials
AzTrials

Coronary Artery DiseaseSPNDNCT07853261

Impact of Stepwise Pressure-Increasing NC Balloon Post-Dilation on Stent Expansion

A study testing Coronary stent + non-compliant post-dilation balloon in people with Coronary Artery Disease and Drug Eluting Stents, run by Jilin University at 1 site in China.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

This is a prospective, single-center, single-arm exploratory observational study aiming to evaluate the impact of stepwise pressure-increasing non-compliant (NC) balloon post-dilation on stent expansion rate in patients undergoing single-stent implantation for coronary artery stenosis, with stent sizing guided by… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease, Drug Eluting Stents
What is being tested?
Coronary stent + non-compliant post-dilation balloon
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
150 participants
Where
1 siteChina
Study dates
7 Jan 2026to 30 Dec 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥18 years regardless of gender;
  • Coronary angiography confirms single-vessel coronary artery stenosis ≥50%, meeting the indication for single-stent implantation;
  • Preoperative IVUS examination can clearly visualize the vessel EEM, allowing for stent size measurement and assessment of stent expansion-related parameters;
  • The patient voluntarily participates in this study and signs the informed consent form;
  • No contraindications related to IVUS examination, stent implantation, or balloon angioplasty.

Who cannot join

  • Hemodynamically unstable
  • Presence of anatomical or pathological factors preventing IVUS catheter crossing.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Mingyou Zhang, M.D. contact

8613689842200

zmy@jlu.edu.cn

China1 site, 1 recruiting
  • The First Hospital of Jilin University

    Changchun, Jilin, 130000

    Recruiting

Other trials in China

About this study

This is a prospective, single-center, single-arm exploratory observational study aiming to evaluate the impact of stepwise pressure-increasing non-compliant (NC) balloon post-dilation on stent expansion rate in patients undergoing single-stent implantation for coronary artery stenosis, with stent sizing guided by intravascular ultrasound-external elastic membrane (IVUS-EEM) measurement.

A total of 150 eligible patients will be enrolled at The First Hospital of Jilin University. All participants will receive standard single-stent implantation followed by multi-stage stepwise pressure-increasing NC balloon post-dilation under IVUS monitoring. The post-dilation protocol includes sequential inflation at nominal pressure, rated burst pressure, and 24 atm, with IVUS assessment performed after each stage. All treatment procedures are conducted in accordance with routine clinical practice; no additional randomization or mandatory intervention is applied beyond the standard of care. The study solely observes and records outcomes associated with this treatment strategy.

Read the detailed description

Coronary atherosclerotic heart disease remains one of the leading causes of mortality and disability worldwide. Coronary stent implantation is a principal therapeutic strategy for coronary artery stenosis. The adequacy of stent expansion is a critical determinant of treatment efficacy; inadequate stent expansion may lead to stent malapposition, in-stent restenosis, stent thrombosis, and other adverse events that significantly compromise patient prognosis.

Intravascular ultrasound (IVUS), as an invasive vascular imaging modality, enables clear visualization of vessel wall architecture, plaque characteristics, and immediate post-stent implantation outcomes. Among its measurements, the external elastic membrane (EEM) cross-sectional area serves as a key reference for stent sizing, effectively overcoming the inherent limitation of conventional coronary angiography, which relies solely on luminal imaging for stent diameter selection.

Non-compliant (NC) balloon post-dilation is an essential step in optimizing stent implantation outcomes. Gradual incremental increases in balloon pressure may further promote adequate stent expansion and improve stent-vessel wall apposition. However, the specific impact of NC balloon post-dilation at different pressures and durations on stent expansion rate has not been systematically validated. To date, there remains a paucity of dedicated studies investigating the dynamic changes in stent expansion rate under a stepwise pressure-increasing protocol.

This study utilizes IVUS-EEM measurements to guide stent sizing and adopts a single-stent implantation strategy combined with multi-stage stepwise pressure-increasing NC balloon post-dilation. after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation. IVUS measurement will be made after each step and stent expansion and Minimal stent area will be documented.

Primary Endpoint. Minimum Stent Area (MSA)

IVUS-measured minimum lumen cross-sectional area within the stented segment post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation)

Secondary endpoints:

Stent Expansion Rate

IVUS-measured stent expansion rate immediately post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation), calculated as: (minimum stent cross-sectional area [MSA] measured by IVUS / manufacturer's nominal MSA) × 100%.

rates of stent edge dissection, hematoma, perforation.

Being tested
Coronary stent + non-compliant post-dilation balloon
Keywords
coronary artery disease, stent, post dilation, stent expansion
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Coronary stent + non-compliant post-dilation balloonDevice

    Coronary stent implantation followed by serial pressure post-dilation using non-compliant balloon under IVUS guidance

Study groups in NCT07853261
Study groupRoleWhat they receive
Serial pressure dilationExperimentalAfter stent nominal pressure deployment stent will be postdilated at 12atm*10s, 18atm *10s, 24atm*10s.Final post-dilation will be attempted at 24 atm for up to 120 seconds, with the duration limited to the patient's maximum tolerated time if premature intolerance occurs.IVUS measurement will be done after each dilation for the MSA and stent expansion
Receives: Device: Coronary stent + non-compliant post-dilation balloon

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Minimum Stent Area (MSA)

    IVUS-measured minimum lumen cross-sectional area within the stented segment post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation), Final post-dilation will be attempted at 24 atm for up to 120 seconds, with the duration limited to the patient's maximum tolerated time if premature intolerance occurs.

    Measured: 3 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Oct 2026
  2. Study start7 Jan 2026
  3. Primary completion30 Dec 2026 (estimated)
  4. Study completion30 Dec 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
150 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07853261
Sponsor's protocol ID
stepwise stent postdilation
Acronym
SPND
Status last verified
Sep 2026
First submitted
23 Sep 2026
Last updated
1 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing Coronary stent + non-compliant post-dilation balloon in people with Coronary Artery Disease and Drug Eluting Stents, run by Jilin University at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 1 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Mingyou Zhang, M.D. (8613689842200, zmy@jlu.edu.cn), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Minimum Stent Area (MSA) (time frame: 3 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Oct 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in