Clinical trials: Aneurysm of Aortic Arch
Aortic Aneurysm, Thoracic, Aorta; Lesion
Evaluation of the GORE® TBE Device in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 2
The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta, requiring Zone 2 proximal implantation…
- Trial name
- SSB 11-02 (NCT02777593)
- Testing
- GORE® TAG® Thoracic Branch Endoprosthesis
- Where
- 35 sites in United States
- Volunteers
- 250 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm, Aortic Dissection
Thoraflex™ Hybrid IDE Study
The study will assess the effectiveness, safety and clinical outcomes of the Thoraflex™ Hybrid Device in the treatment of aortic disease affecting the aortic arch and the descending thoracic aorta, with or without involvement of…
- Conditions
- Aortic Aneurysm, Aortic Dissection, Aortic Rupture
- Trial name
- NCT02724072
- Testing
- Thoraflex™ Hybrid Device
- Where
- 12 sites in United States
- Volunteers
- 84 people
- Sponsor
- Bolton Medical
Aortic Aneurysm, Abdominal, Ascending Aorta Aneurysm
Evaluation of Visceral Function Following Endovascular Aortic Aneurysm Repair Using Branched Stent- Grafts
The purpose of this study is to evaluate visceral function, after endovascular repair of thoracoabdominal aneurysms or ascending/aortic arch aneurysms.
- Conditions
- Aortic Aneurysm, Abdominal, Ascending Aorta Aneurysm, Aortic Arch Aneurysm
- Trial name
- NCT01654133
- Testing
- Endovascular repair of thoracoabdominal aortic aneurysm (TAAA) using branched stent graft, Endovascular repair of ascending/arch aortic aneurysm using branched stent graft
- Where
- United States
- Volunteers
- 770 people
- Sponsor
- University of North Carolina, Chapel Hill
Aneurysms Aortic Arch
Evaluation of Supra-aortic Trunks Debranching Techniques in Open Arch Repair by Means of Frozen Elephant Trunk Procedure With Two Configurations of the Jotec E-Vita Hybrid Graft (FETOPT)
To evaluate two different supra-aortic trunks debranching techniques during open repair of aortic arch aneurysms by means of Frozen Elephant Trunk procedure with two configurations of the Jotec E-Vita hybrid graft.
- Trial name
- FETOPT (NCT03600077)
- Where
- Italy
- Volunteers
- 50 people
- Sponsor
- IRCCS San Raffaele
Cardio-pulmonary Bypass, AORTIC VALVE DISEASES
Clinical Validation of a Novel Handsfree Doppler Ultrasound Device, RescueDoppler, in Adult Cardiac Surgery Patients
The goal of this study is to evaluate a new device called RescueDoppler (RD), which measures continuous blood flow in the common carotid artery. The device is handsfree and operator- independent.
- Conditions
- Cardio-pulmonary Bypass, AORTIC VALVE DISEASES, Coronary Arterial Disease (CAD), Aortic Aneurysm of the Proximal Arch
- Trial name
- RD_CPB (NCT06637540)
- Testing
- RescueDoppler
- Where
- 3 sites in Norway
- Volunteers
- 42 people
- Sponsor
- St. Olavs Hospital
Aortic Diseases
Percutaneous Endovascular Arch Repair Trial (PEART) Study
This study is the feasible study on a new technique of ZIPPER aortic arch stentgraft system
- Trial name
- NCT05872282
- Testing
- ZIPPER aortic arch stentgraft system
- Where
- 3 sites in China
- Volunteers
- 24 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aneurysm of Aortic Arch
Early Feasibility of the Branched TAG® Device in the Treatment of Aortic Arch Aneurysms
The purpose of this study is to assess the early feasibility of the use of the GORE® TAG® Thoracic Branch Endoprosthesis to treat aneurysms involving the aortic arch
- Trial name
- NCT02264977
- Testing
- GORE® TAG® Thoracic Branch Endoprosthesis
- Where
- 6 sites in United States
- Volunteers
- 9 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm of the Proximal Arch
Branched Aortic Arch Study
This is a study to assess the safety and effectiveness of endovascular treatment of aortic aneurysms involving the proximal aortic arch. The investigational operation involves placing a stent-graft over the aortic aneurysm.
- Trial name
- NCT00488696
- Testing
- Endovascular Bifurcated Stent-Graft
- Where
- United States
- Sponsor
- Timothy Chuter, MD
Aortic Arch Aneurysm
Guo's Aortic Arch Reconstruction: A Multicenter, Prospective Study of the Novel WeFlow-Tribranch System (GENIUS Study)
A prospective ,Multiple Center Study About the Safety and Efficacy of WeFlow-Tribranch Embedded Aortic Triple-branch Arch Stent Graft System manufactured by EndoNom Medtech (Hangzhou) Co., Ltd.
- Trial name
- NCT06385379
- Testing
- WeFlow-Tribranch embedded aortic Triple-branch arch Stent Graft system
- Where
- 20 sites in China
- Volunteers
- 90 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aortic Dissection, Aortic Arch
Repair Versus Non-repair of the Aortic Arch in Type A Aortic Dissection
Acute Stanford type A aortic dissection (TAAD) is a life-threatening clinical status requiring surgery that is usually performed as a salvage procedure.We planned a multicenter study to evaluate the balance between the patient's…
- Conditions
- Aortic Dissection, Aortic Arch, Aortic Dissection Rupture, Aortic Dilatation
- Trial name
- AoArch (NCT05912634)
- Testing
- Conservative TAAD-R, Extensive TAAD- R
- Where
- France
- Volunteers
- 900 people, healthy volunteers welcome
- Sponsor
- Centre Cardiologique du Nord
Aortic Arch Aneurysm
Simulation of Stent-graft Deployment in Aortic Arch Aneurysms
Total endovascular repair of the aortic arch represents a promising option for patients ineligible to open surgery. Custom-made design of stent-grafts (SG), such as the Terumo Aortic® RelayBranch device (DB), requires complex…
- Trial name
- NCT04244188
- Testing
- Collection of datas
- Where
- 2 sites in France, Netherlands
- Volunteers
- 4 people
- Sponsor
- Centre Hospitalier Universitaire de Saint Etienne
Thoracic Aortic Arch Disease, Thoracic Aortic Aneurysm
NEXUS™ Aortic Arch Stent Graft System First In Man Study
A multicenter, prospective, open-label, non-randomized, interventional clinical study, sponsored by Endospan Ltd. Patients will be followed-up for five years.
- Trial name
- NCT02365454
- Testing
- Stent Graft Placement (Nexus)
- Where
- 4 sites in Czechia, Italy and 1 more
- Volunteers
- 18 people
- Sponsor
- Endospan Ltd.
Aortic Dissection
the Aorta Arch Stent Graft System Combined With the Endovascular Needle System in Situ Fenestration
A prospective, multi-center, single-group target value method to evaluate the safety and effectiveness of the Aorta Arch Stent Graft System combined with the Endovascular Needle System in situ fenestration technology in the…
- Trial name
- NCT05126446
- Testing
- the Aorta Arch Stent Graft System combined with the Endovascular Needle System
- Where
- China
- Volunteers
- 120 people
- Sponsor
- Lifetech Scientific (Shenzhen) Co., Ltd.
Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
CAAAs, TAAAs, Aortic Arch Aneurysms or Dissections With Fenestrated/Branched Stent Graft
The purpose of this study is to gather safety and effectiveness of the Zenith t-Branch and customized physician-specified stent-graft with a combination of fenestrations and/or branches to repair aortic aneurysm.
- Conditions
- Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm, Aortic Arch Aneurysm, Aortic Arch Dissection
- Trial name
- NCT02089607
- Testing
- CAAA and TAAA Arm, Aortic Arch Aneurysm Arm
- Where
- 3 sites in United States
- Volunteers
- 760 people
- Sponsor
- Gustavo S Oderich
Aortic Aneurysm, Aortic Dissection
A Novel Wire-Reinforced Fenestration of a Hybrid Frozen Elephant Trunk Device for Supra-Aortic Branch Vessel Stenting During Aortic Arch Replacement
The goal of this prospective, non-randomized trial is to determine the safety and technical success of a novel modification to a U.S.
- Conditions
- Aortic Aneurysm, Aortic Dissection, Penetrating Aortic Ulcer (PAU), Aortic Pseudoaneurysm
- Trial name
- SA-FET (NCT07885865)
- Testing
- Modified Supra-Aortic Frozen Elephant Trunk (SA-FET) Device
- Where
- United States
- Volunteers
- 100 people
- Sponsor
- University of Maryland, Baltimore
Aortic Arch Aneurysm, Aortic Arch Dissection
Clinical Study to Evaluate the Safety and Effectiveness of Arcevo LSA
The goal of this clinical trial is to learn if the Arcevo LSA stent graft can safely and effectively treat patients that have an acute or chronic aortic dissection and/or aneurysm that involves the aortic arch and the descending…
- Conditions
- Aortic Arch Aneurysm, Aortic Arch Dissection, Chronic Aortic Dissection, Acute Aortic Dissection
- Trial name
- ARTIZEN (NCT07089576)
- Testing
- Arcevo™ LSA Hybrid Stent Graft System
- Where
- 26 sites in United States, Germany and 1 more
- Volunteers
- 132 people
- Sponsor
- Artivion Inc.
Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
European Aortic Data Collection Project
The purpose of this study is to evaluate the safety and performance of Cook's various Custom-Made Stent-graft Devices (CMD) used for endovascular treatment of the aorta and related diseases by collecting information on the…
- Conditions
- Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm, Aortic Arch Aneurysm, Chronic Aortic Dissection
- Trial name
- EADC (NCT05896397)
- Testing
- Endovascular Aortic Treatments
- Where
- 18 sites in Denmark, France and 4 more
- Volunteers
- 600 people
- Sponsor
- Cook Research Incorporated
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Thoracic
Endovascular Treatment of TAAA and Aortic Arch Aneurysms Using Fenestrated and Branched Stent Grafts
Prospective, nonrandomized, single-center, two-arm study to assess the feasibility and safety and to evaluate clinical outcomes of endovascular repair of complex aortic aneurysms (thoracoabdominal aortic aneurysms and aortic arch…
- Conditions
- Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Thoracic, Aortic Dissection, Thoracoabdominal
- Trial name
- NCT02323581
- Testing
- Endovascular treatment of Thoracoabdominal Aortic Aneurysm, Endovascular treatment of Aortic Arch Aneurysms
- Where
- 2 sites in United States
- Volunteers
- 520 people
- Sponsor
- Darren Schneider, M.D.
Aortic Arch, Aortic Arch Aneurysm
Outcome of a Triple Inner Branched Aortic Arch Stentgraft. A Prospective, Multicenter Registry.
Outcome of a triple inner branched aortic arch stentgraft. A prospective, mulitcenter registry.
- Conditions
- Aortic Arch, Aortic Arch Aneurysm, Dissection of Aortic Arch, Triple Branch
- Trial name
- triple_branch (NCT05530304)
- Testing
- Triple inner branched arch stentgraft
- Where
- Germany
- Volunteers
- 30 people
- Sponsor
- University Hospital Muenster
Thoracic Aortic Dissection, Thoracic Aortic Aneurysm (true Aneurysm)
Quick Yielding Modified Short-Distance Fenestration Technique for the Treatment of Complex Aortic Arch Diseases: a Multicenter Single-Arm Objective Performance Criteria Trial(QYM-Tech Study)
Background: This study investigates the safety and efficacy of a novel surgical approach combining thoracic endovascular aortic repair (TEVAR) and in situ fenestration reconstruction of supra-aortic branches using the Quick…
- Conditions
- Thoracic Aortic Dissection, Thoracic Aortic Aneurysm (true Aneurysm), Thoracic Pseudoaneurysm, Penetrating Aortic Ulcer
- Trial name
- NCT06639243
- Testing
- QYM Technique
- Where
- China
- Volunteers
- 87 people
- Sponsor
- Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine