Clinical trials: Cardiac Pacemaker Artificial
Heart Failure, Congestive, Cardiac Pacemaker, Artificial
Optivol Diagnostic Data for Discharge in Heart Failure
The objective of this study is to evaluate whether the heart rate variability, daily heart rate, and/or intrathoracic impedance recorded by implantable cardiac devices can be used in conjunction with other traditional clinical…
- Trial name
- 3DHF (NCT00420108)
- Where
- 5 sites in United States
- Volunteers
- 23 people
- Sponsor
- Thomas Jefferson University
Cardiac Rhythm Disorder, Bradycardia
Patient Preferences for Leadless Pacemakers
Prospective, non-randomized, multi-center study designed to quantify patient preferences pertaining to risks and features of conventional transvenous pacemakers and leadless pacemakers
- Conditions
- Cardiac Rhythm Disorder, Bradycardia, Cardiac Pacemaker Artificial
- Trial name
- NCT05327101
- Testing
- Patient Preference Survey
- Where
- 11 sites in United States
- Volunteers
- 117 people
- Sponsor
- Abbott Medical Devices
Cardiac Pacemaker, Artificial
Imaging Study of Lead Implant for His Bundle Pacing
The purpose of this research study is to assess the implant success proportion of the Medtronic SelectSecure MRI SureScan Model 3830 pacing lead at the bundle of His for His bundle pacing.
- Trial name
- (IMAGE-HBP) (NCT03294317)
- Testing
- His bundle pacing
- Where
- 3 sites in United States
- Volunteers
- 70 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Bradyarrhythmias, Arrhythmias
Thromboembolic Complications After Pacemaker or Implantable Cardioverter-Defibrillator Procedures
This is a large prospective registry of patients submitted to cardiac electronic devices implantation designed to investigate the incidence, risk factors and prognostic of thromboembolic complications associated with transvenous…
- Conditions
- Bradyarrhythmias, Arrhythmias, Cardiovascular Disease, Venous Thrombosis
- Trial name
- NCT01717495
- Where
- Brazil
- Volunteers
- 1 people
- Sponsor
- University of Sao Paulo
Pacemaker, Artificial
A Pilot Study on Pacemaker Interference From Peripheral Nerve Stimulator for Regional Anesthesia
In this prospective pilot study, we proposed to evaluate the effects of left interscalene stimulation on cardiac pacemaker function.
- Trial name
- NCT00586248
- Where
- United States
- Volunteers
- 14 people, healthy volunteers welcome
- Sponsor
- Mayo Clinic
Cardiac Pacing, Artificial, Cardiac Pacemaker, Artificial
Optimize RV Selective Site Pacing Clinical Trial
The purpose of the Optimize RV study is to determine the long-term effect of selective site pacing. Selective site pacing refers to which area of the right ventricle the lead is placed.
- Trial name
- NCT00422669
- Testing
- Medtronic Dual-Chamber Pacemaker, Medtronic SelectSecure 3830 Lead
- Where
- 22 sites in United States, Canada and 4 more
- Volunteers
- 205 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Arrhythmia, Bradycardia
CAPTURE - Complete Automatic Pacing Threshold Utilization Recorded by EnPulse
This study compares the pacemaker's automatic pacing threshold measurements to the manual measurements conducted by a health care provider.
- Trial name
- NCT00275769
- Testing
- Pacemaker
- Where
- 57 sites in United States, Canada
- Volunteers
- 860 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Pacemaker, Artificial
Comparison Between Early and Late Mobilization After Cardiac Device Implantation
Mobilization after cardiac implantable electronic devices (CIED) implantation is highly variable between centers, some discharging home after 3-4 hours while others request bed restriction for 24 hours.
- Trial name
- NCT03530904
- Testing
- mobilization
- Volunteers
- 400 people
- Sponsor
- Carmel Medical Center
Device Related Infection, Device Malfunction
Project My Heart Your Heart: Pacemaker Reuse
Lack of access to pacemakers is a major challenge to the provision of cardiovascular health care in Low and Middle Income Countries (LMIC).
- Conditions
- Device Related Infection, Device Malfunction, Bradycardia
- Trial name
- MHYH (NCT04016870)
- Testing
- Reconditioned Pacemaker, New Pacemaker
- Where
- 8 sites in Kenya, Mexico and 5 more
- Volunteers
- 370 people
- Sponsor
- University of Michigan
Pain Measurement, Chronic Pain
Evaluation of Chronic Postsurgical Pain Risk in Patients Undergoing CIED Implantation Using an AID Support System
Chronic postsurgical pain (CPSP) remains a significant clinical and public health challenge despite major advances in surgical and anesthetic techniques.
- Conditions
- Pain Measurement, Chronic Pain, Cardiac Implantable Electrical Devices, Neuropathic Pain
- Trial name
- PAIN-AID (NCT07322900)
- Volunteers
- 180 people
- Sponsor
- Istanbul University - Cerrahpasa
Atrial Fibrillation, Stroke
Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation
This study aims to determine if treatment with apixaban, compared with aspirin, will reduce the risk of ischemic stroke and systemic embolism in patients with device-detected sub-clinical atrial fibrillation and additional risk…
- Trial name
- ARTESiA (NCT01938248)
- Testing
- Apixaban, aspirin
- Where
- 130 sites in United States, Belgium and 11 more
- Volunteers
- 4,012 people
- Sponsor
- Population Health Research Institute
Cardiac Pacing, Artificial
Closed Loop Stimulation, Cognitive Performance, and Quality of Life in Pacemaker Patients
The purpose of this study is to compare the influence of accelerometer-based rate adaptation and Closed Loop Stimulation on cognitive performance and quality of life in pacemaker patients.
- Trial name
- COGNITION (NCT00323661)
- Testing
- Rate-adaptive pacemaker: accelerometer, Rate-adaptive pacemaker: Closed Loop Stimulation
- Where
- 55 sites in Australia, Austria and 8 more
- Volunteers
- 405 people
- Sponsor
- Biotronik SE & Co. KG
Cardiac Pacemaker, Artificial
The Potential Interference of Magnets From a Surgical Magnetic Drape With Cardiac Pacemakers
Magnetic fields may interfere with the function of cardiac pacemakers. A magnetic drape to hold surgical instruments is widely used in surgery. The use of this drape on pacemaker patients has not yet been tested.
- Trial name
- NCT01009320
- Where
- Canada
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- Maisonneuve-Rosemont Hospital
Defibrillators, Implantable, Follow-Up Studies
Remote Programming of Cardiac Implantable Electronic Device
Cardiac Implantable Electronic Devices (CIEDs) such as pacemakers and implantable cardioverter defibrillators, need to be regularly interrogated and reprogrammed to ensure proper functioning.
- Conditions
- Defibrillators, Implantable, Follow-Up Studies, Pacemaker, Artificial, Telemedicine
- Trial name
- REACT (NCT05366660)
- Testing
- Interrogation/programming
- Where
- France
- Volunteers
- 110 people
- Sponsor
- University Hospital, Bordeaux
Disorder of Cardiac Pacemaker System
Evaluation Of Pacemakers in Children
Pacemakers were introduced into clinical practice several decades ago and currently are used in a growing number of patients. Since insertion of the first cardiac Pacemaker in 1958, vast changes have occurred in both the…
- Trial name
- NCT04163770
- Testing
- caliberation of pacemaker
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- Assiut University
Sick Sinus Syndrome
Mode Evaluation in Sick Sinus Syndrome Trial (MODEST)
The purpose of this study is to determine the incidence of atrial fibrillation and heart failure in patients with pacemaker therapy with different pacing modes (AAI, DDD, and a novel algorithm to minimize ventricular pacing).
- Trial name
- NCT00161551
- Testing
- Vitatron T70 DR
- Where
- 5 sites in Germany
- Volunteers
- 402 people
- Sponsor
- Medtronic BRC
Pacemaker, Artificial, Cardiomyopathies
Genetic Basis of Pacing-induced Cardiomyopathy
The purpose of this study is to collect a saliva sample from patients with a pacemaker to study genes involved in cardiomyopathy, a condition where the heart muscle is abnormal.
- Trial name
- NCT03317964
- Testing
- Saliva sample
- Where
- United States
- Volunteers
- 153 people
- Sponsor
- The Guthrie Clinic
Disorder of Cardiac Pacemaker System, Disorder of Implantable Defibrillator
Examination of Implant´s Safety in an Electronic and Magnetic Field Environment
The number of active electrical cardiac implants such as internal cardioverter defibrillators (ICDs), pacemakers or cardiac contractility modules (CCM) has significantly risen over the last two decades.
- Conditions
- Disorder of Cardiac Pacemaker System, Disorder of Implantable Defibrillator, Cardiac Arrhythmia
- Trial name
- FEMU (NCT01626261)
- Testing
- Magnetic and electric field´s impact on the implant
- Where
- Germany
- Volunteers
- 281 people
- Sponsor
- RWTH Aachen University
Heart Failure, Pacemaker
OPTimising a Screening Program to Detect Pacemaker-associated Heart Failure Using Artificial Intelligence
Pacemakers are an effective treatment for slow heart rates which improve symptoms and save lives. However, for some people pacemakers can cause heart failure (HF) because of the unnatural way in which they stimulate heart beats.
- Trial name
- OPT-AI (NCT07372651)
- Where
- United Kingdom
- Volunteers
- 150 people
- Sponsor
- University of Leeds
Cardiac Pacemaker, Artificial, Cardiac Rhythm Disorder
Aveir DR i2i Study
Prospective, non-randomized, multi-center, international study designed to evaluate the safety and effectiveness of the Aveir™ Dual-Chamber (DR) Leadless Pacemaker system.
- Conditions
- Cardiac Pacemaker, Artificial, Cardiac Rhythm Disorder, Bradycardia
- Trial name
- NCT05252702
- Testing
- Aveir DR Leadless Pacemaker System
- Where
- 78 sites in United States, Austria and 11 more
- Volunteers
- 464 people
- Sponsor
- Abbott Medical Devices