Clinical trials: Denture Retention
Denture Retention, Complete Dentures
Retention of Maxillary Complete Dentures Modified With Titanium Dioxide Nanoparticles: A Randomized Crossover Clinical Trial.
This study investigates the effect of the addition of titanium dioxide nanoparticles to denture base materials on their retention compared to that of the unmodified denture base materials.
- Trial name
- NCT04991064
- Testing
- Complete denture base modified by Titanium dioxide nanoparticles.
- Where
- Egypt
- Volunteers
- 10 people, healthy volunteers welcome
- Sponsor
- Cairo University
Mouth, Edentulous
Influence of Implants and Locators for Improved Retention
The aim of this study is to assess the influence of this particular treatment method on the patients' quality of life and masticatory function.
- Trial name
- GC (NCT02551146)
- Testing
- A Locator with retention elements, B Locator without retention elements
- Where
- Germany
- Volunteers
- 14 people
- Sponsor
- Philipps University Marburg
Denture Retention
A Study to Assess the Effectiveness of a Marketed Denture Adhesive in Real-World Setting
The purpose of this decentralised study in a real-world setting is to assess the effectiveness of a marketed denture adhesive (Poligrip Power Max Hold + Seal) in preventing food entrapment under dentures (self-assessed).
- Trial name
- NCT07273149
- Testing
- Poligrip Power Max Hold + Seal
- Where
- United States
- Volunteers
- 375 people, healthy volunteers welcome
- Sponsor
- HALEON
Denture,Complete, Edentulous Alveolar Ridge
Conventional Versus 3D Printing Duplication Techniques of Complete Denture
Twenty completely edentulous patients with old, removable dentures with ill-fitting maxillary dentures, proper vertical dimension, and proper occlusion will be recruited for this trial.
- Trial name
- NCT06588140
- Testing
- Duplicated refitted complete denture made from conventionally heat-cured polymethyl methacrylate., Duplicated refitted complete denture made from 3D-printed CAD/CAM pink polymethylmethacrylate acrylic resin., Duplicated refitted complete denture made from 3D-printed CAD/CAM white polymethylmethacrylate acrylic resin.
- Where
- Egypt
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Ain Shams University
Denture Retention
A Clinical Study to Assess Force Required to Dislodge Upper Denture With and Without Use of a Novel Denture Adhesive
The purpose of this study is to investigate the hold properties of an investigational denture adhesive using an established methodology called the maximum incisal bite force (BF), and Kapur-Olshan (KO) index for denture retention…
- Trial name
- NCT04473521
- Testing
- Investigational denture adhesive cream, Super Poligrip Free
- Where
- United States
- Volunteers
- healthy volunteers welcome
- Sponsor
- GlaxoSmithKline
Denture Retention
Evaluation of a Experimental Denture Adhesive to Prevent Food Ingress
In this clinical study, an experimental denture adhesive with a precision tip nozzle was tested to evaluate the relative efficacy to reduce the ingress of food under the denture compared to use of no adhesive or a standard…
- Trial name
- NCT02928380
- Testing
- Experimental Denture Adhesive, Reference (Marketed) Denture Adhesive
- Where
- United States
- Volunteers
- 83 people, healthy volunteers welcome
- Sponsor
- GlaxoSmithKline
Edentulous Jaw
Intraoral Scanning v.s Desktop Scanning
The aim of this study was to evaluate the effect of intraoral scanning versus desktop scanning on the retention and adaptation of maxillary denture bases in completely edentulous patients.
- Trial name
- NCT06509269
- Testing
- intraoral scanning, Desktop scanning
- Where
- Egypt
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- British University In Egypt
Problem With Dentures
(PEEK) Housing Verses Metallic Housing of Ball and Socket Attachment on Retention of Mandibular Overdenture
The aim of this study is to compare the clinical effect of PEEK housing vs. metal housing in terms of retention and patient satisfaction
- Trial name
- NCT02950662
- Testing
- Overdenture
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Cairo University
Edentulous Mouth
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
Analyzing and comparing the retention, accuracy, EMG and patient satisfaction of maxillary complete denture base fabricated by conventional and rapid prototyping techniques.
- Trial name
- NCT05834530
- Testing
- 3D Printed Complete Dentures
- Where
- Egypt
- Volunteers
- 10 people, healthy volunteers welcome
- Sponsor
- Al-Azhar University
Dentures
Retention, Stability and Performance Assessment of Denture Fixatives Versus no Fixative Control
This clinical investigation will evaluate the effectiveness, tolerability and safety of two denture fixative creams versus no fixative control
- Trial name
- RESONATE (NCT05689814)
- Testing
- Paraffin based Denture Fixative
- Where
- United Kingdom
- Volunteers
- 71 people, healthy volunteers welcome
- Sponsor
- Reckitt Benckiser Healthcare (UK) Limited
Edentulous Mouth, Quality of Life
Impact of Retro-molar Pad Demarcation on Complete Denture Wearers' Satisfaction
the retromolar pad is a critical anatomical landmark in the lower edentulous arch marking the posterior end of any removable prosthesis.
- Conditions
- Edentulous Mouth, Quality of Life, Patient Satisfaction, Complete Edentulism
- Trial name
- RMP (NCT07246343)
- Testing
- carving of retromolar pad area (RMP), no carving of the retromolar pad area (RMP)
- Where
- Jordan
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- Samiha Sartawi
Implant Site Reaction, Implant Complication
Retention, Chewing Efficiency and Masticatory Performance of Partial Dentures Opposing Implant Retained Prosthesis.
This study aims to evaluate retention ,chewing efficiency and masticatory performance of flexible versus CAD/CAM partial dentures opposing to fixed implant retained restorations.
- Trial name
- NCT05999760
- Testing
- evaluation of retention of Versacryle and CAD/CAM partial dentures by force gauge, chewing efficiency by electromyograph(E.M.G), masticatory performance(questionnaire)
- Where
- Egypt
- Volunteers
- 22 people
- Sponsor
- National Research Centre, Egypt
Edentulous Mandible, Implant-Supported Overdentures
Mandibular Implant Overdenture With Bar vs OT Equator: A Randomized Controlled Trial
This clinical study will evaluate two types of attachment systems used to support lower dentures in patients who have lost all their lower teeth.
- Trial name
- NCT07121881
- Testing
- Bar Attachment, Bar with OT Equator Attachment
- Where
- Egypt
- Volunteers
- 22 people, healthy volunteers welcome
- Sponsor
- Hala Abdel salam Selim
Edentulous Mouth, Edentulous Jaw
Mandibular Overdentures Retained by Conventional or Mini Implants
This study aims to compare mandibular overdentures retained either by mini or standard size implants as a treatment for edentulous adults, in terms of patient-reported satisfaction and oral health-related quality of life.
- Trial name
- NCT01411683
- Testing
- Implant-retained mandibular overdenture
- Where
- Brazil
- Volunteers
- 120 people
- Sponsor
- University of Sao Paulo
Edentulous Mandible, Implant-Supported Overdentures
Mandibular Implant Overdenture With OT Cap Bar vs Bar Attachment
This clinical study is being conducted at Cairo University to evaluate two different types of attachments used with implant-supported dentures in the mandible.
- Trial name
- NCT07067190
- Testing
- Conventional Bar Attachment, Bar with OT Cap Attachment
- Where
- Egypt
- Volunteers
- 22 people, healthy volunteers welcome
- Sponsor
- Maisa Mohamed Farid Shaaban
Denture Retention
A Clinical Study to Evaluate the Maximum Maxillary Bite Force (BF) When Using Two Novel Denture Adhesives Compared to Using No-Adhesive
The purpose of this study is to investigate the hold properties of two experimental denture adhesives using established maximum incisal BF methodology.
- Trial name
- NCT05173974
- Testing
- Super Poligrip Free, Experimental Denture Adhesive 1, Experimental Denture Adhesive 2
- Where
- United States
- Volunteers
- 45 people, healthy volunteers welcome
- Sponsor
- HALEON
Complete Edentulism, Randomized Clinical Trial
Retention of Dome and Flat Magnetic Attachments in Mandibular Implant Overdentures Randomized Controlled Clinical Trial
Aim of the Study The aim of this study is to compare between two forms of magnetic attachments in implant retained mandibular over-dentures.
- Trial name
- NCT07642128
- Testing
- Flat Magnetic Attachment, Dome Magnetic Attachment
- Where
- Egypt
- Volunteers
- 14 people, healthy volunteers welcome
- Sponsor
- Ain Shams University
Implant Breakage
Retention and Wear Characteristic Assessment of OT Equator Smart Box Attachment
This research aimed to evaluate the retentive power and wear of the smart box attachment use with tilted two implant assisted mandibular overdenture
- Trial name
- NCT04718454
- Testing
- dental attachment
- Volunteers
- 10 people
- Sponsor
- Cairo University
Partial-edentulism, Temporary Partial Denture
Evaluation of Digital 3D Printed Temporary Removable Partial Denture.
This study aims to compare oral health-related quality of life and retention between digitally- fabricated temporary flexible RDPs and conventionally-fabricated temporary flexible RDPs.
- Conditions
- Partial-edentulism, Temporary Partial Denture, 3D Printing, Oral Health Related Quality of Life
- Trial name
- NCT06106243
- Testing
- The conventional heat pressing temporary flexible maxillary removable partial denture, 3D-printed and digitally designed temporary flexible maxillary removable partial denture
- Where
- Egypt
- Volunteers
- 13 people, healthy volunteers welcome
- Sponsor
- Cairo University
Mandibular Prosthesis User
Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework in Removable Partial Denture Regarding Retention
This study is aiming to evaluate the retentive forces in PEEK framework RPD compared to Cobalt-Chrome framework RPD during attachment/detachment cycles in mandibular kennedy class I edentulous cases
- Trial name
- NCT03777280
- Testing
- peek framework RPD, cobalt chromium framework RPD
- Where
- Egypt
- Volunteers
- 30 people
- Sponsor
- Cairo University