Clinical trials: Descending Aortic Aneurysm
Aortic Aneurysm, Thoracic, Penetrating Aortic Ulcers (PAUs)
Evaluation of Thoraflex in the Treatment of Aneurysm or Penetrating Ulcer of the Descending Thoracic Aorta
ThoraflexTM is designed for the treatment of aneurysm or penetrating ulcer of the descending thoracic aorta. Each system is advanced from a transfemoral or transiliac approach over a 0.035" guidewire and positioned under…
- Trial name
- NCT01357590
- Testing
- Thoracic Endovascular Stent Graft System (ThoraflexTM)
- Where
- 28 sites in Belgium, Canada and 5 more
- Sponsor
- Vascutek Ltd.
Thoracic Aortic Aneurysms
Post-Approval Clinical Study of the Talent Thoracic Stent Graft to Treat Thoracic Aortic Aneurysms (THRIVE)
The purpose of this study is to evaluate the long-term safety and effectiveness of the Talent Thoracic Stent Graft System for treatment of descending thoracic aneurysms (DTA)following U.S. market approval.
- Trial name
- THRIVE (NCT00805948)
- Testing
- Talent Thoracic Stent Graft System
- Where
- 26 sites in United States
- Volunteers
- 349 people
- Sponsor
- Medtronic Cardiovascular
Aortic Dissection, Distal Entry Tear
Guo&Amp;'s Distal Entry Tear Repair With WeFlow-EndoPatch System (Gallant Study)
A Multicenter, Randomized Controlled Study About the Safety and Efficacy of WeFlow-EndoPatch Aortic Endovascular Patch System manufactured by EndoNom Medtech (Hangzhou) Co., Ltd. for Chronic Aortic Dissection . (GALLANT Study)
- Trial name
- Gallant (NCT06945809)
- Testing
- WeFlow-EndoPatch Aortic Endovascular Patch System, Conventional Treatment group
- Where
- China
- Volunteers
- 216 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aortic Aneurysm, Thoracic
GORE TAG® Thoracic Endoprosthesis - 45 mm for the Treatment of Aneurysms of the Descending Thoracic Aorta
The objective of this study is to assess the safety and efficacy of the 45 mm TAG device in subjects with aneurysms of the descending thoracic aorta.
- Trial name
- NCT00608829
- Testing
- GORE TAG® Thoracic Endoprosthesis
- Where
- United States
- Volunteers
- 23 people
- Sponsor
- W.L.Gore & Associates
Dissection of Thoracic Aorta, Dissection of Thoracic Descending Aorta
European Multi-Centre Post-Market Registry on Thoracic Endovascular Arch Repair Using Castor™ and Cratos™
The Castor™ and Cratos™ Branched Aortic Stent Graft Systems are medical devices designed for the minimally invasive endovascular treatment of thoracic aortic pathologies in the descending aorta.
- Conditions
- Dissection of Thoracic Aorta, Dissection of Thoracic Descending Aorta, Aneurysm of Aorta, Thoracic, Penetrating Aortic Ulcers (PAUs)
- Trial name
- CEDAR (NCT07668687)
- Testing
- Implantation with Castor™ stent graft, Implantation with Cratos™ stent graft
- Where
- 4 sites in Germany, Switzerland
- Volunteers
- 100 people
- Sponsor
- Shanghai MicroPort Endovascular MedTech(Group)Co., Ltd
Aortic Dissection
The VIRTUE Post Marketing Surveillance Registry
The purpose of this post-market release registry is to collect additional information concerning safety, performance and health economic data with respect to the Medtronic VALIANT Thoracic Stent Graft with the Xcelerant Delivery…
- Trial name
- VIRTUE (NCT01213589)
- Volunteers
- 100 people
- Sponsor
- Medtronic Endovascular
Thoracic Aortic Aneurysm, Penetrating Aortic Ulcer
Zenith Thoracic Alpha (ZTA) Post-Market Data Collection
This study aims to gather real-world clinical data demonstrating the continued safety and performance of the a marketed stent graft (Zenith® Alpha Thoracic Endovascular Graft [ZTA]) and collect longer term follow-up to better…
- Trial name
- NCT06094127
- Testing
- Endovascular aortic treatment
- Where
- 10 sites in France, Germany and 2 more
- Volunteers
- 300 people
- Sponsor
- Cook Research Incorporated
Aortic Arch; Aneurysm, Dissecting
Study of the Thoraflex™ Hybrid Device for the Treatment of Aneurysm/Dissection of the Descending Thoracic Aorta
The purpose of this national observational study is to evaluate the Thoraflex™ Hybrid vascular prosthesis in the replacement of the aortic arch and the treatment of aneurysm/dissection of the descending thoracic aorta in relation…
- Trial name
- NCT03735472
- Testing
- Thoraflex™ Hybrid
- Where
- 37 sites in France
- Volunteers
- 351 people
- Sponsor
- Vascutek Ltd.
Aortic Aneurysm, Aortic Dissection
Thoraflex™ Hybrid IDE Study
The study will assess the effectiveness, safety and clinical outcomes of the Thoraflex™ Hybrid Device in the treatment of aortic disease affecting the aortic arch and the descending thoracic aorta, with or without involvement of…
- Conditions
- Aortic Aneurysm, Aortic Dissection, Aortic Rupture
- Trial name
- NCT02724072
- Testing
- Thoraflex™ Hybrid Device
- Where
- 12 sites in United States
- Volunteers
- 84 people
- Sponsor
- Bolton Medical
Aortic Aneurysm, Thoracic
Evaluation of the GORE TAG Thoracic Endoprosthesis in the Treatment of Aneurysms
The purpose of this post-approval study is to evaluate the long-term performance of the GORE TAG® Thoracic Endoprosthesis (TAG device) in the primary treatment of descending thoracic aortic (DTA) aneurysms
- Trial name
- NCT00590759
- Testing
- GORE TAG® Thoracic Endoprosthesis
- Where
- 25 sites in United States
- Volunteers
- 150 people
- Sponsor
- W.L.Gore & Associates
Descending Thoracic Aortic Aneurysm
Zenith TX2® Post-market Approval Study
The Zenith TX2® Post-market Approval Study is a clinical trial approved by US FDA to further study the safety and effectiveness of the Zenith TX2® TAA Endovascular Graft in the treatment of thoracic aortic aneurysms.
- Trial name
- TX2 2PAS (NCT00813358)
- Testing
- Zenith TX2® TAA Endovascular Graft
- Where
- 25 sites in United States, Canada
- Volunteers
- 115 people
- Sponsor
- Cook Research Incorporated
Thoracic Aortic Aneurysm
Valor II: The Valiant Thoracic Stent Graft System Clinical Study
This study was designed to study safety and effectiveness of the Valiant Thoracic Stent Graft to treat thoracic aortic aneurysms.
- Trial name
- NCT00413231
- Testing
- Valiant Thoracic Stent Graft System
- Where
- 26 sites in United States
- Volunteers
- 160 people
- Sponsor
- Medtronic Cardiovascular
Thoracic Aortic Aneurysm
STARZ-TX2 Clinical Study: Study of Thoracic Aortic Aneurysm Repair With the Zenith TX2 Endovascular Graft
The STARZ-TX2 trial (Study of Thoracic Aortic Aneurysm Repair with the Zenith TX2(R) TAA [Thoracic Aortic Aneurysm] Endovascular Graft) is a clinical trial approved by the United States Food and Drug Administration (FDA) to study…
- Trial name
- STARZ-TX2 (NCT00111176)
- Testing
- Endovascular repair, Surgical
- Where
- 41 sites in United States, Canada and 1 more
- Volunteers
- 260 people
- Sponsor
- Cook Group Incorporated
Aortic Aneurysm, Thoracic, Aorta; Lesion
Evaluation of the GORE® TBE Device in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 2
The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta, requiring Zone 2 proximal implantation…
- Trial name
- SSB 11-02 (NCT02777593)
- Testing
- GORE® TAG® Thoracic Branch Endoprosthesis
- Where
- 35 sites in United States
- Volunteers
- 250 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm, Thoracic, Descending Thoracic Aortic Dissection
GORE® TAG® Thoracic Endoprosthesis French Mandatory Registry
This is a French Registry mandated by the French National Health Authority assessing long-term (5-years) safety of the GORE® TAG® Thoracic Endoprosthesis treating diseases of the thoracic aorta.
- Conditions
- Aortic Aneurysm, Thoracic, Descending Thoracic Aortic Dissection, Aortic Diseases, Aorta Thoracic; Traumatic Rupture
- Trial name
- NCT02266342
- Testing
- GORE® TAG® Thoracic Endoprostheses
- Where
- France
- Volunteers
- 154 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm, Thoracic, Descending Thoracic Aortic Dissection
Valiant Thoracic Stent Graft With the Captivia Delivery System in the Treatment of Descending Thoracic Aortic Diseases (VALIANT CAPTIVIA France)
The objective of this study is to assess the benefits of endovascular technique in terms of efficacy and safety of Valiant Thoracic Stent Graft with the Captivia Delivery System in the treatment of thoracic aortic disease, in a…
- Conditions
- Aortic Aneurysm, Thoracic, Descending Thoracic Aortic Dissection, Penetrating Ulcer, Aorta Thoracic; Traumatic Rupture
- Trial name
- NCT01775046
- Testing
- DTA patients (Valiant)
- Where
- 17 sites in France
- Volunteers
- 160 people
- Sponsor
- Medtronic Cardiovascular
Thoracic Aortic Aneurysm
ENTRUST - TAArget® Thoracic Stent Graft Clinical Trial
Evaluate the safety and effectiveness of endovascular repair with the LeMaitre TAArget thoracic stent graft as an alternative to open surgical repair.
- Trial name
- NCT01033214
- Testing
- Endovascular repair of TAA in the descending Thoracic Aorta
- Where
- 2 sites in United States
- Volunteers
- 30 people
- Sponsor
- Duke Vascular, Inc.
Aortic Aneurysm, Thoracic
Feasibility Study for GORE® TAG® Thoracic Branch Endoprosthesis to Treat Proximal Descending Thoracic Aortic Aneurysms
The purpose of this study is to assess the feasibility of the use of the GORE® TAG® Thoracic Branch Endoprosthesis to treat aneurysms involving the proximal Descending Thoracic Aorta (DTA)
- Trial name
- NCT02021812
- Testing
- GORE® TAG® Thoracic Branch Endoprosthesis
- Where
- 6 sites in United States
- Volunteers
- 31 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm, Thoracic, Aorta, Lesion
Evaluation of the GORE® TBE Device in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 0/1
The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta.
- Trial name
- SSB 11-02 (NCT02777528)
- Testing
- GORE® TAG® Thoracic Branch Endoprosthesis, Revascularization Procedure
- Where
- 39 sites in United States, Japan
- Volunteers
- 79 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm, Aortic Aneurysm Abdominal
Prophylactic Suture Line Sealing With NE'X Glue R-eco in Cardiac and Vascular Surgery
This clinical study aims to evaluate the effectiveness and safety of using NE'X Glue R-eco to seal suture lines. The adhesive will be applied to reduce the risk of suture line bleeding in cardiac or vascular repair surgeries, a…
- Conditions
- Aortic Aneurysm, Aortic Aneurysm Abdominal, Valve Stenoses, Aortic, Valve Regurgitation, Mitral
- Trial name
- CLOSURE (NCT06918496)
- Testing
- Surgical placement of a prosthetic or biologic graft (patch), or an allograft for cardiac and (cardio)vascular repair.
- Where
- 2 sites in Belgium, Poland
- Volunteers
- 60 people
- Sponsor
- Grena Biomed Limited