Clinical trials: Juxtarenal Aneurysms, active
Abdominal Aortic Aneurysms
Physician Modified Endovascular Grafts
The primary objectives of this study are to determine whether physician modified endovascular grafts (PMEG) and specified company manufactured investigational devices are a safe and effective method of treating patients with…
- Trial name
- PMEG (NCT01538056)
- Testing
- Fenestrated Endovascular Graft or Company Manufactured Terumo Aortic Fenestrated TREO Endovascular Graft
- Where
- United States
- Volunteers
- 500 people
- Sponsor
- University of Washington
Abdominal Aortic Aneurysm, Juxtarenal Abdominal Aortic Aneurysm
Evaluation of Clinical Efficacy and Safety of Aortal Stent-Graft Created Using 3D Printing Technology
the comparison of physician-modified stent-graft created in 3D models versus custom-made devices in the treatment of complex abdominal aortic aneurysm
- Conditions
- Abdominal Aortic Aneurysm, Juxtarenal Abdominal Aortic Aneurysm, Pararenal Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
- Trial name
- NCT06969729
- Testing
- Physician-Modified Fenestrated Stent-Graft (3D-Printed Template-Guided)
- Where
- Poland
- Volunteers
- 100 people
- Sponsor
- Samodzielny Publiczny Szpital Kliniczny nr 2 PUM
Complex Abdominal Aortic Aneurysm, Juxtarenal Aortic Aneurysm
Physician Modified Endograft For Complex Aortic Aneurysm Repair
The physician modified endograft is intended for treating complex, pararenal, juxtarenal and thoracoabdominal aortic aneurysms requiring coverage of renal arteries, the superior mesenteric artery or the celiac trunk in high-risk…
- Conditions
- Complex Abdominal Aortic Aneurysm, Juxtarenal Aortic Aneurysm, Pararenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
- Trial name
- NCT05339061
- Testing
- Endovascular Treatment of Complex abdominal or Thorocoabdominal aneurysms (TAAA).
- Where
- United States
- Volunteers
- 40 people
- Sponsor
- University of California, Davis
Juxtarenal Aortic Aneurysm, Pararenal Aneurysm
Clinical Outcomes and Major Adverse Events in Patients Treated With Physician-Modified Fenestrated and Branched Stent Grafts
The purpose of this study is to evaluate safety and effectiveness of endovascular treatment of juxtarenal, pararenal and thoracoabdominal aortic aneurysms (with or without iliac artery involvement) using physician-modified stent…
- Conditions
- Juxtarenal Aortic Aneurysm, Pararenal Aneurysm, Thoracoabdominal Aortic Aneurysm
- Trial name
- NCT06526676
- Testing
- Cook Alpha TX2 Stent Graft, Cook Zenith TX2, and Cook Zenith Fenestrated Stent Graft
- Where
- United States
- Volunteers
- 50 people
- Sponsor
- University of California, Los Angeles
Juxtarenal Abdominal Aortic Aneurysm
University of Utah PS-IDE: Physician Modified Endovascular Grafts for the Treatment of Elective, Symptomatic or Ruptured Juxtarenal Aortic Aneurysms
The purpose of this study is to assess the effects of a physician-modified endovascular graft (PMEG) for juxtarenal aortic aneurysms by collecting data on its performance.
- Trial name
- NCT07065760
- Testing
- Endovascular Aneurysm Repair with Physician Modified Endograft
- Where
- United States
- Volunteers
- 15 people
- Sponsor
- Cali Johnson
Juxtarenal Aortic Aneurysms, Suprarenal Aortic Aneurysms
Complex Abdominal Aortic Aneurysm Repair With Fenestrated Stent Grafts
The purpose of this study is to evaluate clinical outcomes and quality of life measures in treated by endovascular aortic repair of juxtarenal, suprarenal, and type IV thoracoabdominal aortic aneurysms using custom-made Cook…
- Conditions
- Juxtarenal Aortic Aneurysms, Suprarenal Aortic Aneurysms, Type IV Thoracoabdominal Aortic Aneurysms
- Trial name
- NCT01937949
- Testing
- Custom-made Zenith® Fenestrated AAA Endovascular Graft:
- Where
- 2 sites in United States
- Volunteers
- 200 people
- Sponsor
- Gustavo S Oderich
Complex Aortic Aneurysms, Thoracoabdominal Aneurysms
Complex Aortic Aneurysm Repair Using Physician Modified Endografts and Custom Made Devices
The purpose of this study is to evaluate the safety and efficacy of custom made devices, Zenith t-Branch devices and physician modification of FDA approved off-the-shelf endovascular grafts in the treatment of patients with…
- Conditions
- Complex Aortic Aneurysms, Thoracoabdominal Aneurysms, Pararenal Aneurysms, Juxtarenal Aneurysms
- Trial name
- CARPE-CMD (NCT02050113)
- Testing
- Custom Made Fenestrated or Branched Stent Graft
- Where
- United States
- Volunteers
- 600 people
- Sponsor
- Andres Schanzer
Thoracoabdominal Aneurysms
Visceral Manifold and Unitary Device Study for the Repair of Thoracoabdominal Aortic Aneurysms
The primary objective of the Visceral Manifold and Unitary Device Study is to assess the use of the thoracic bifurcation and the visceral manifold or the unitary device to repair thoracoabdominal aortic aneurysms in patients…
- Trial name
- NCT02294435
- Testing
- Visceral Manifold and Thoracic Bifurcation, Unitary Manifold
- Where
- United States
- Volunteers
- 250 people
- Sponsor
- Sanford Health
Juxtarenal Aneurysms, Open Repair
Juxtarenal Aortic Aneurysm
All patients with a juxtarenal abdominal aortic aneurysm who underwent open aneurysm therapy between January 2010 and July 2020 were included retrospectively.
- Trial name
- NCT06988345
- Volunteers
- 200 people
- Sponsor
- University Hospital Muenster
1 Paravisceral Abdominal Aortic Aneurysm, 2 Juxtarenal Abdominal Aortic Aneurysm
Chimney EndoVascular Aneurysm Sealing Of New Expanded Indication
Prospective, multi-center, non-randomized study with consecutive, eligible subject enrollment at each site, for the evaluation of the ChEVAS System for Endovascular Repair of Complex Abdominal Aortic Aneurysms.
- Conditions
- 1 Paravisceral Abdominal Aortic Aneurysm, 2 Juxtarenal Abdominal Aortic Aneurysm, 3 Pararenal Abdominal Aortic Aneurysm, 4 Complex Abdominal Aortic Aneurysms
- Trial name
- ChEVAS One (NCT04252573)
- Testing
- Chimney Endovascular Aortic Sealing (ChEVAS) System
- Where
- 8 sites in United States
- Volunteers
- 13 people
- Sponsor
- Endologix
Juxtarenal Aortic Aneurysm, Suprarenal Aortic Aneurysm
Evaluation of the Cook Custom Aortic Endograft, the Zenith t-Branch Endovascular Graft, and Surgeon-Modified Endograft in Treating Aortic Pathologies
This is a single-center study to evaluate the safety and effectiveness of three investigational devices, the Cook Custom Aortic Endograft, the Zenith t-Branch Endovascular Graft, and the Surgeon-Modified Endografts in the…
- Conditions
- Juxtarenal Aortic Aneurysm, Suprarenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm, Penetrating Aortic Ulcer
- Trial name
- NCT02043691
- Testing
- Cook Custom Aortic Endograft, Zenith t-Branch Endovascular Graft, Surgeon-Modified Endograft
- Where
- United States
- Volunteers
- 410 people
- Sponsor
- University of Alabama at Birmingham
Thoracoabdominal Aneurysm, Juxtarenal Aortic Aneurysm
Safety and Effectiveness of Surgeon-Modified Stent Grafts forTreatment of Complex Aortic Aneurysms
The primary objective of the present study is to evaluate the safety, effectiveness, and clinical outcomes of surgeon-modified fenestrated stent grafts used to treat patients with failed previous infrarenal repairs (failed EVAR)…
- Conditions
- Thoracoabdominal Aneurysm, Juxtarenal Aortic Aneurysm, Pararenal Aneurysm, Aortic Aneurysm
- Trial name
- Assets (NCT05531084)
- Testing
- Surgeon-Modified fenestrated stent grafts using Cook Zenith Platform (Zfen, TX2, Alpha Thoracic Endovascular Graft and Zenith Flex)
- Where
- United States
- Volunteers
- 25 people
- Sponsor
- Jesse Manunga, MD
Aortic Aneurysm, Abdominal, Juxtarenal Aortic Aneurysm
Zenith® Fenestrated+ Clinical Study
The Zenith® Fenestrated+ Endovascular Graft Clinical Study will assess the safety and effectiveness of the Zenith® Fenestrated+ Endovascular Graft (ZFEN+) in combination with the BeGraft Balloon-Expandable FEVAR Bridging Stent…
- Conditions
- Aortic Aneurysm, Abdominal, Juxtarenal Aortic Aneurysm, Extent IV Thoracoabdominal, Pararenal Aneurysm
- Trial name
- NCT04875429
- Testing
- Zenith Fenestrated+ Endovascular Graft in combination with the BeGraft Balloon-Expandable FEVAR Bridging Stent Graft System and Unibody2
- Where
- 33 sites in United States, United Kingdom
- Volunteers
- 105 people
- Sponsor
- Cook Research Incorporated
AAA - Abdominal Aortic Aneurysm
Endurant CHevAr New Indication Trial: ENCHANT
The purpose of the post-market study is to assess the clinical outcomes, safety, and performance of the Endurant Chimney Graft Technique (Endurant Stent Graft Systems used with a balloon-expandable covered stent graft) for…
- Trial name
- ENCHANT (NCT03320252)
- Testing
- Endurant Chimney Graft Technique
- Where
- 26 sites in Austria, France and 11 more
- Volunteers
- 150 people
- Sponsor
- Medtronic Cardiovascular
Aneurysm Aortic
Evaluation of the Efficacy of Ischemic Preconditioning to Protect Against Acute Kidney Injury After Open Surgery for Juxtarenal Abdominal Aortic Aneurysm
Juxta-renal abdominal aortic aneurysms (AAA) are challenging to treat with standard endovascular techniques (EVAR) due to their proximity to the renal arteries.
- Trial name
- EPAKI (NCT07441564)
- Testing
- patients with aortic clamping with preconditioning, patients with aortic clamping without preconditioning
- Where
- 7 sites in France
- Volunteers
- 206 people
- Sponsor
- University Hospital, Rouen
Technical Sucess, Freedom From Type I and III Endoleaks at 12 Months
Physician Modified Endovascular Grafts for the Treatment of Elective, Symptomatic or Ruptured Juxtarenal Aortic Aneurysms
Patients who are found to have an aneurysm (bulge) in the abdominal aorta, which is the blood vessel in your abdomen (belly) that supplies blood to most of your lower body, including major organs and your legs.
- Conditions
- Technical Sucess, Freedom From Type I and III Endoleaks at 12 Months, Freedom From Stent Graft Migration at 12 Months, Freedom From Aortic Aneurysm Enlargement at 12 Months
- Trial name
- NCT07019454
- Testing
- Physician Modified Endografting
- Where
- United States
- Volunteers
- 15 people
- Sponsor
- Baystate Medical Center