Clinical trials: Manikin
Cardiopulmonary Resuscitation (CPR), Electrical Shock
Effect of Electrically Insulated Gloves on ROSC Time, End-tidal CO₂ Response, Survival and Morbidity in Uninterrupted CPR
Cardiopulmonary arrest is the sudden cessation of spontaneous breathing and circulation due to various causes. Cardiopulmonary resuscitation (CPR) is the set of decisions and procedures encompassing all efforts aimed at restoring…
- Conditions
- Cardiopulmonary Resuscitation (CPR), Electrical Shock, Defibrillation
- Trial name
- IG-CPR (NCT07299188)
- Testing
- HANDS ON BUT OFF DEFIBRILLATION
- Where
- Turkey (Türkiye)
- Volunteers
- 32 people
- Sponsor
- Izmir Katip Celebi University
Intubation;Difficult
Long Endotracheal Tube vs. Aintree Intubating Catheter for Fiberoptic-guided Intubation in Manikin
In difficult airway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option. Aintree catheter is a device to help change LMA to endotracheal tube, but it needs complex and multiple…
- Trial name
- NCT03645174
- Testing
- Using long tube, Aintree catheter
- Where
- South Korea
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Ajou University School of Medicine
Medical Education, Simulation-based Methodology
MIxed ReAlity Versus Manikin Simulation in Basic Life Support Training for Medical Students: a Noninferiority Randomized Controlled Trial (MIRA).
Purpose: To compare the effectiveness of mixed reality and traditional manikin-based simulation in basic life support (BLS) training, making the hypothesis that mixed reality was non-inferior to manikin-based simulation.
- Conditions
- Medical Education, Simulation-based Methodology, Virtual Reality, Cardiac Arrest (CA)
- Trial name
- MIRA (NCT06832072)
- Testing
- MR-BLS
- Where
- France
- Volunteers
- 225 people
- Sponsor
- Sorbonne University
Cardiac Arrest
Endotracheal Intubation Using Three Laryngoscopes in Maternal Cardiac Arrest: a Manikin Simulation Study
European Resuscitation Council (ERC) Guidelines for Resuscitation 2010 emphasize high quality chest compressions .They propose minor changes for pregnant women: manual left deviation of the uterus or a left-lateral incline of…
- Trial name
- NCT02074072
- Testing
- 15 degree left-lateral tilt wedges, 30 degree left-lateral tilt wedges
- Where
- South Korea
- Volunteers
- 19 people, healthy volunteers welcome
- Sponsor
- Hanyang University Seoul Hospital
Healthy Participants
Effectiveness of CPR Pillow
Pillows can be used to facilitate safe and effective learning and as a cheaper and more accessible alternative to manikins or computer-based methods for CPR training by non-healthcare professionals.
- Trial name
- NCT07160881
- Testing
- Pillow maniquin training
- Where
- Turkey (Türkiye)
- Volunteers
- 128 people, healthy volunteers welcome
- Sponsor
- University of Beykent
Tracheal Intubation
Assessment of Provider Position for Prehospital Tracheal Intubation
Endotracheal intubation may be needed in critically ill patients in the prehospital setting, where difficult conditions may be encountered.
- Trial name
- NCT07165314
- Testing
- Free positioning, Sitting cross-legged ("Lotus" position)
- Where
- Switzerland
- Volunteers
- 72 people, healthy volunteers welcome
- Sponsor
- University Hospital, Geneva
Computer Simulator and Mannequin Simulator
The Comparison of the Two Simulators for ACLS Training
Compared two different training simulators(the computer screen-based simulator versus the full-scale mannequin-based simulator) with respect to training effectiveness in ACLS training.At the same time,evaluate the effectiveness…
- Trial name
- NCT05001659
- Testing
- computer simulator and mannequin simulator
- Where
- 2 sites in China
- Volunteers
- 10 people
- Sponsor
- Tianjin Medical University General Hospital
Airway Morbidity, Emergencies
Supraglottic Airway Devices in Pediatric Difficult Airway Situations
The purpose of the study is to compare three supraglottic airway devices (Combitube, Easytube, laryngeal mask airway) to endotracheal intubation in a simulated difficult airway scenario in a pediatric manikin.
- Trial name
- NCT02572232
- Testing
- Combitube, Easytube, Laryngeal masks
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- Medical University of Vienna
Cardiac Arrest
The Manikin Study of Chest Compression With One Accelerometer Feedback Device
Chest compression (CC) feedback devices are used to perform CC measurements effectively and accurately on patients in hospital beds.
- Trial name
- NCT02073539
- Testing
- Stryker ST104-747, Shinchang SB-34p
- Where
- South Korea
- Volunteers
- 19 people, healthy volunteers welcome
- Sponsor
- Hanyang University Seoul Hospital
Simulation Training
Optimal Training Frequency for Attainment and Maintenance of High-quality CPR on a High-fidelity Manikin
Objectives: The primary objective is to determine the least frequent CPR training interval associated with continued performance of guideline-compliant CPR.
- Trial name
- NCT02998307
- Testing
- CPR Training
- Where
- Canada
- Volunteers
- 244 people, healthy volunteers welcome
- Sponsor
- Health Sciences North
Improvement of BLS/AED Training Methods
Retention and Retrieval for Three Different Training Methods
The hypotheses that will be studied are: H0: Providers trained by a web based application for skill competency in basic life support (BLS) and automated external defibrillation (AED) are as competent as those who were trained by…
- Trial name
- NCT00933660
- Testing
- ERC-training by instructor, Web-based training only, Web-based training with a personal training manikin
- Volunteers
- 280 people, healthy volunteers welcome
- Sponsor
- Doczero
Time Until Identification of Defined Parameter
Evaluating Different Pediatric Emergency Rulers in a Manikin Study - How Fast and Correct Are They
Comparison of three different pediatric emergency rulers for length-based body weight estimation in pediatric emergencies. Primary outcome is the time needed to identify four defined parameters from the pediatric emergency rulers…
- Trial name
- NCT03650296
- Testing
- ePER vs PS vs PaedER
- Where
- Switzerland
- Volunteers
- 33 people, healthy volunteers welcome
- Sponsor
- University Children's Hospital, Zurich