Clinical trials: Orthodontic Appliance Complication
Orthodontic Appliance Complication
Using Probiotics to Improve Oral Hygiene During Orthodontic Treatment
Fifty patients needing non-extraction-based metallic orthodontic treatment will be divided randomly into the probiotic group and the control group.
- Trial name
- NCT06641960
- Testing
- Probiotics, Traditional treatment
- Where
- Syria
- Volunteers
- 50 people
- Sponsor
- Damascus University
Basic Science, Orthodontic Appliance Complication
Clinical Effectiveness of the Calcium Chloride (CaCl2) Surface- Treated Orthodontic Mini Implant (OMI)
The goal of this split mouth, randomised control study was to compare the clinical effectiveness of surface treated Calcium Chloride orthodontic mini implant in orthodontic patients.
- Conditions
- Basic Science, Orthodontic Appliance Complication, Malocclusion
- Trial name
- NCT06607536
- Testing
- calcium chloride surface treatment in mini implant, Acid Etched
- Where
- Malaysia
- Volunteers
- 48 people, healthy volunteers welcome
- Sponsor
- Universiti Teknologi Mara
Orthodontic Appliance Complication
Efficiency of Rigid Versus Non-rigid Indirect Anchorage During Canine Retraction: A Split Mouth Randomized Study
Indirect anchorage (In-A) has been broadly used for anchorage reinforcement during anterior segment retraction. The study compared between the efficacy of rigid vs non-rigid connections of In-A i during upper canine retraction in…
- Trial name
- NCT06554769
- Testing
- non rigid indirect anchorage connection, rigid indirect anchorage connection
- Where
- Egypt
- Volunteers
- 15 people, healthy volunteers welcome
- Sponsor
- Cairo University
Orthodontic Appliance Complication
Orthodontic Treatment Impact on Life Experience of Adolescents With Fixed Orthodontic Appliances
This cross-sectional study aimed to investigate the impact of different fixed orthodontic appliances on the day-to-day life experience of adolescent patients at any stage of their orthodontic treatment.
- Trial name
- NCT06518733
- Testing
- appliance type
- Where
- Egypt
- Volunteers
- 364 people
- Sponsor
- Cairo University
Orthodontic Appliance Complication
Evaluation of The Stability of Orthodontic Treatment After First Premolar Extraction Using Combined Retention Protocol
The aim of this study is to compare between the stability of anterior and posterior segments in both arches using bonded lingual retainers versus a combined protocol of retention (bonded lingual retainer and vacuum formed…
- Trial name
- NCT06502886
- Testing
- combined protocol of retention (bonded lingual retainer and vacuum formed retainers), Bonded lingual retainer
- Where
- Egypt
- Volunteers
- 24 people, healthy volunteers welcome
- Sponsor
- Cairo University
Orthodontic Appliance Complication
Effectiveness of Methods to Remove Residual Orthodontic Adhevsie
The aim of this study is to compare the clinical efficacy of different residual orthodontic adhesive removing methods for rebonding debonded metal attachments.
- Trial name
- NCT05929391
- Testing
- Recycling orthodontic brackets
- Where
- Iraq
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- University of Baghdad
Orthodontic Appliance Complication, Malocclusion, Angle Class II, Division 1
Mini-implant-supported Twin-Block in Treating Patients With Class II Division 1 Malocclusion
Correcting the skeletal class II using functional appliances, whether removable or fixed, always leads to skeletal and alveolar effects.
- Trial name
- NCT06403033
- Testing
- Mini-implant-supported Twin-Block, Twin-Block
- Where
- Syria
- Volunteers
- 41 people
- Sponsor
- Damascus University
Orthodontic Appliance Complication
Evaluation of Two Mini-Implant Lengths in the Infra-Zygomatic Crest Region
Evaluation of two different lengths of mini-implants in the infrazygomatic area regarding primary stability, pain perception, sinus penetration, secondary stability and failure rate.
- Trial name
- NCT06293872
- Testing
- 12*2 mm length miniscrew
- Where
- Iraq
- Volunteers
- 24 people, healthy volunteers welcome
- Sponsor
- University of Baghdad
Orthodontic Appliance Complication
Assessment of Coated Orthodontic Miniscrews With Chlorhexidine Hexametaphosphate Antimicrobial Nanoparticles
Aim To compare between orthodontic miniscrews coated and uncoated with CHX- HMP NP nanoparticles.
- Trial name
- NCT06124235
- Testing
- Coated Orthodontic Miniscrews with Chlorhexidine Hexametaphosphate Nanoparticles, Uncoated Miniscrew with Chlorhexidine Hexametaphosphate Nanoparticles
- Where
- Iraq
- Volunteers
- 39 people, healthy volunteers welcome
- Sponsor
- University of Baghdad
Taste Perception, Orthodontic Appliance Complication
Alteration of Taste Among Orthodontic Patients Following Clear Aligners Treatment
The goal of this clinical trial is aimed to assess the gustatory perception and alteration in patients using either clear aligners or fix orthodontics treatment in orthodontic patient aged +18 years and not have any endocrine…
- Conditions
- Taste Perception, Orthodontic Appliance Complication, Fixed Orthodontic Appliances
- Trial name
- NCT06124742
- Testing
- clear aligners
- Where
- Saudi Arabia
- Volunteers
- 134 people, healthy volunteers welcome
- Sponsor
- Riyadh Elm University
Orthodontic Appliance Complication, Tooth Demineralization
Fluoride Delivery to Prevent White Spots During Orthodontic Treatment
The aim of this 2-armed, parallel, randomised, controlled trial is to assess the effect of different ways of applying fluoride to teeth on the formation of white spots (enamel demineralisation), during orthodontic treatment with…
- Trial name
- FL4OWS (NCT05005689)
- Testing
- Fluoride mouthwash (0.05%; 225ppm)., Tooth Mousse Plus
- Where
- United Kingdom
- Volunteers
- 130 people
- Sponsor
- Liverpool University Hospitals NHS Foundation Trust
Evaluations, Diagnostic Self, Antimicrobial
ZnO Nanoparticles Coated Orthodontic Molar Tube
Orthodontic treatment is an elective procedure to improve the patient's dentofacial appearance. The complex design of fixed appliances provides a platform that leads to increased plaque accumulation around orthodontic brackets.
- Conditions
- Evaluations, Diagnostic Self, Antimicrobial, Orthodontic Appliance Complication, Bacterial Overgrowth
- Trial name
- ZnONPs (NCT06089720)
- Testing
- Zinc oxide nanoparticle coated orthodontic molar tubes (experimental), orthodontic molar tubes (control)
- Where
- Iraq
- Volunteers
- 18 people, healthy volunteers welcome
- Sponsor
- University of Baghdad
Gingivitis, Orthodontic Appliance Complication
Photodynamic Therapy in Patients With Gingivitis
The hypothesis to be tested in this study is whether photodynamic therapy (PDT) could favor the decontamination of these areas, as the photosensitizer and light are capable of reaching areas that these instruments have difficulty…
- Conditions
- Gingivitis, Orthodontic Appliance Complication, Photodynamic Therapy
- Trial name
- NCT04037709
- Testing
- scaling and root planing (SRP) + PDT
- Where
- Brazil
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- University of Nove de Julho
Orthodontic Appliance Complication
The Effects of Different Storage Conditions on Removable Retainers
Orthodontic removable retainers are appliances that hold the position of the upper and lower teeth after fixed braces treatment and they can be removed from a patient's mouth.
- Trial name
- NCT05854953
- Testing
- Hawley retainers in dry storage condition, Hawley retainers in wet storage condition, VFRs in dry storage condition
- Where
- Malaysia
- Volunteers
- 24 people, healthy volunteers welcome
- Sponsor
- University of Malaya
White Spot Lesion, Orthodontic Appliance Complication
A Prospective, Randomized, Clinical Study on the Effects of CPP-ACP-paste, Fluoride and a Combination on the Evolution of White Spot Lesions in Orthodontic Patients After Debonding.
The goal of this randomized clinical trial is to compare the influence of casein phosphopeptide amorphous calcium phosphate (CPP-ACP), CPP-ACP in combination with fluoride (CPP-ACPF), high fluoride concentration, and conventional…
- Trial name
- NCT05710874
- Testing
- CPP-ACP paste, CPP-ACPF paste, 1.25% fluoride gel
- Where
- Belgium
- Volunteers
- 107 people, healthy volunteers welcome
- Sponsor
- University Hospital, Ghent
Orthodontic Appliance Complication
Effectiveness of Low Frequency Vibration on the Rate of Canine Retraction
The goal of this Randomized controlled clinical trial is To investigate the effectiveness of AcceleDent Aura vibrating device on rate of canine retraction in orthodontic treatment..
- Trial name
- NCT05818527
- Testing
- Acceledent vibrating device
- Volunteers
- 32 people, healthy volunteers welcome
- Sponsor
- mohamed abdelmotaleb
Orthodontic Appliance Complication, Dental Malocclusion
Changes in the Upper Airway Volume After Rapid Maxillary Expansion in Adults Using Pure Skeletal Anchorage
The objective of this study is to evaluate the effect of bone-anchored rapid maxillary expansion (RME) in the volume of the right maxillary sinus, left maxillary sinus and nasal and maxillary sinus airway complex, through bone…
- Conditions
- Orthodontic Appliance Complication, Dental Malocclusion, Bone Anchored Rapid Maxillary Expansion, Maxillary Hypoplasia
- Trial name
- NCT05831722
- Testing
- Rapid Maxillary Expansion
- Where
- 3 sites in Spain
- Volunteers
- 18 people, healthy volunteers welcome
- Sponsor
- University of Salamanca
Orthodontic Appliance Complication, Shear Strength
Comparison Between Shear Bond Strength of Different Commercial Metal Bracket Brands: an in Vitro Study
some orthodontic brands are more expensive than others, one of the primary outcomes of this study is to know if is it worth using expensive brands? will it provide better quality treatment, in particular, bond strength? The…
- Trial name
- NCT05812456
- Testing
- Estimation of Shear Bond Strength
- Where
- Egypt
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- Future University in Egypt
Orthodontic Appliance Complication
Bracket Failure With a Novel Etchant Paste. A Randomized Clinical Trial
To investigate metallic brackets failure rate bonded post enamel conditioning with a novel CaP etchant paste in comparison with those bonded following conventional enamel etching with PA gel over a period of 6 months.
- Trial name
- failurerate (NCT05766033)
- Testing
- Enamel conditioning with a novel etchant paste
- Where
- Iraq
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- University of Baghdad
Orthodontic Appliance Complication
Evaluation of Maxillary Canine Retraction Assisted With Two Different Methods of Low-Intensity Pulsed Ultrasound
The current clinical study will be done for evaluation of maxillary canine retraction assisted with application of two different methods of low-intensity pulsed ultrasound.
- Trial name
- NCT05692817
- Testing
- Low-Intensity Pulsed Ultrasound
- Where
- Egypt
- Volunteers
- 16 people, healthy volunteers welcome
- Sponsor
- Ammar Kasem Alzoubi