Clinical trials: Pulmonary Vein Isolation
- Condition Pulmonary Vein Isolation
- Funder type Industry (pharma, biotech, devices)
- Has posted results yes
Paroxysmal Atrial Fibrillation
REVOLUTION (WFCC-133) - Treatment of Paroxysmal Atrial Fibrillation
The purpose of this study is to assess the safety and effectiveness of the Circular and Crescent Mapping and Ablation catheters and the workflow of the Multi-Electrode Irrigated Pulmonary Vein Isolation System when used for the…
- Trial name
- REVOLUTION (NCT01353586)
- Testing
- nMARQ™ System
- Where
- 8 sites in Belgium, Czechia and 4 more
- Volunteers
- 186 people
- Sponsor
- Biosense Webster, Inc.
Paroxysmal Atrial Fibrillation
Multi-electrode Radiofrequency Balloon Catheter Use for the Isolation of the Pulmonary Veins.
This clinical investigation is a prospective, multicenter, single arm clinical evaluation utilizing the multi-electrode radiofrequency balloon catheter and the multi-electrode circular diagnostic catheter.
- Trial name
- SHINE (NCT03437733)
- Testing
- Radiofrequency Ablation
- Where
- 5 sites in Czechia, Italy and 1 more
- Volunteers
- 98 people
- Sponsor
- Biosense Webster, Inc.
Paroxysmal Atrial Fibrillation
A Single Arm Pilot Study of Pulsed Field Ablation in the Treatment of Paroxysmal Atrial Fibrillation
The objective of this pilot study is to confirm that endocardial ablation using the FARAPULSE Ablation System Plus with commercial design devices is both safe and effective for treating drug-resistant paroxysmal atrial…
- Trial name
- FARA-Free (NCT04474054)
- Testing
- Catheter ablation to treat paroxysmal atrial fibrillation
- Where
- Croatia
- Volunteers
- 15 people
- Sponsor
- Boston Scientific Corporation
Paroxysmal Atrial Fibrillation
TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation
The TOCCASTAR Study will assess the safety and effectiveness of a contact force sensing catheter used for ablation in patients with paroxysmal atrial fibrillation.
- Trial name
- TOCCASTAR (NCT01278953)
- Testing
- Catheter ablation to treat paroxysmal atrial fibrillation
- Where
- United States
- Volunteers
- 300 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation
Postmarket Evaluation of the Phased Radio Frequency Ablation System (GOLD AF Registry)
Prospective, multi-center, single-arm, non-interventional and open-label registry. The purpose of the registry is to document use of Phased Radio Frequency Ablation (RFA) (hereafter "Phased RFA") System in a real world patient…
- Trial name
- NCT02433613
- Where
- 41 sites in France, Georgia and 12 more
- Volunteers
- 1,071 people
- Sponsor
- Medtronic Cardiac Ablation Solutions
Paroxysmal Atrial Fibrillation
Post-Market Randomized Trial: Endoscopically- Guided Ablation vs. Radiofrequency Ablation
To compare the safety and chronic Pulmonary Vein isolation of 2 ablation types. 1. visually guided ablation (VGA) using the EAS-AC and 2. radiofrequency ablation
- Trial name
- En-GARDE (NCT01057394)
- Testing
- Endoscopically guided PVI Ablation, RF PVI Ablation
- Where
- 2 sites in Czechia, Italy
- Volunteers
- 21 people
- Sponsor
- CardioFocus
Atrial Fibrillation
SMART China, A Multi-center Clinical Registry Study
This is a prospective effectiveness and safety assessment of the study device during radiofrequency (RF) ablation treatment of patients with drug refractory symptomatic atrial fibrillation.
- Trial name
- NCT02485925
- Testing
- THERMOCOOL® SMARTTOUCH™
- Volunteers
- 200 people
- Sponsor
- Biosense Webster, Inc.
Atrial Fibrillation
nMARQ™ Pulmonary Vein Isolation System for the Treatment of Paroxysmal Atrial Fibrillation
To demonstrate safety and effectiveness of nMARQ Catheter System [nMARQ] compared with THERMOCOOL® Navigational Family of catheters in treating subjects with drug-refractory symptomatic paroxysmal atrial fibrillation (PAF).
- Trial name
- NCT01824394
- Testing
- nMARQ Navigation Catheters, NaviStar ThermoCool Catheters
- Volunteers
- 481 people
- Sponsor
- Biosense Webster, Inc.
Paroxysmal Atrial Fibrillation
The FARAPULSE FARA-Freedom Trial
The Post-Market Clinical Follow-Up trial is a prospective, multi-center, open-label, single-arm clinical follow-up study designed to provide long-term safety feasibility, effectiveness and performance of the FARAPULSE Pulsed…
- Trial name
- FARA-Freedom (NCT05072964)
- Testing
- FARAPULSE Pulsed Field Ablation System
- Where
- 13 sites in Belgium, Czechia and 4 more
- Volunteers
- 180 people
- Sponsor
- Boston Scientific Corporation
Paroxysmal Atrial Fibrillation
Evaluation of VISITAG SURPOINT™ Module With External Processing Unit (EPU)
Prospective, non-randomized, post market clinical evaluation of the VISITAG SURPOINT™ Module with External Processing Unit (EPU) when used with STSF catheter and ST catheter compared to an historical control performance goal.
- Trial name
- NCT03624881
- Testing
- Catheter ablation with EPU
- Where
- 41 sites in United States
- Volunteers
- 333 people
- Sponsor
- Biosense Webster, Inc.
Paroxysmal Atrial Fibrillation
HeartLight Ablation in Patients With Paroxysmal Atrial Fibrillation (PAF)
The purpose of this study is to demonstrate the safety and effectiveness of the CardioFocus Endoscopic Ablation System with Adaptive Contact (HeartLight) in the treatment of atrial fibrillation by creating electrical isolation of…
- Trial name
- HeartLight (NCT01456000)
- Testing
- EAS-AC (HeartLight), Control Arm Ablation
- Where
- 21 sites in United States
- Volunteers
- 405 people
- Sponsor
- CardioFocus
Paroxysmal Atrial Fibrillation
FIRM Ablation Versus Pulmonary Vein Isolation for the Treatment of Paroxysmal Atrial Fibrillation (PAF)
The study is designed as a prospective, multicenter, single-blind, randomized study to assess the safety and effectiveness of FIRM-guided radiofrequency (RF) ablation procedures for the treatment of symptomatic paroxysmal atrial…
- Trial name
- FIRMAP-AF (NCT02703454)
- Testing
- FIRM-guided RF ablation, Conventional RF ablation
- Where
- Germany
- Volunteers
- 51 people
- Sponsor
- Abbott Medical Devices
Paroxysmal Atrial Fibrillation, Persistent Atrial Fibrillation
Automated Assessment of PVI Using a Novel EP Recording System
A prospective, multi-center study with the CathVision Cube® system and the PVI Analyzer software in radiofrequency (RF), cryo-balloon (CB), and Pulse Field Ablation (PFA) procedures.
- Trial name
- PVISION (NCT05043883)
- Testing
- CathVision Cube® system
- Where
- 4 sites in Belgium, France
- Volunteers
- 101 people
- Sponsor
- CathVision ApS
Paroxysmal Atrial Fibrillation
Evaluation of QDOT MICRO™ Catheter for Pulmonary Vein Isolation in Subjects With Paroxysmal Atrial Fibrillation
Prospective, non-randomized, pre-market clinical evaluation of the QDOT MICRO™ Catheter to demonstrate the safety and effectiveness when compared to an historical control performance goal.
- Trial name
- Q-FFICIENCY (NCT03775512)
- Testing
- RF Ablation with QDOT Micro
- Where
- 22 sites in United States
- Volunteers
- 283 people
- Sponsor
- Biosense Webster, Inc.
Atrial Fibrillation, Tachycardia, Supraventricular
TOCCATA - Touch+™ for Catheter Ablation
The main objective of this study is to demonstrate the clinical safety of a contact force sensing RF ablation catheter when used for the treatment of supraventricular tachycardia and atrial fibrillation.
- Trial name
- TOCCATA (NCT01223469)
- Testing
- Contact force assisted irrigated RF ablation
- Volunteers
- 77 people
- Sponsor
- Abbott Medical Devices