Clinical trials: Therapeutic Procedural Complication
Therapeutic Procedural Complication
the Diameter of Double-lumen Tube Measured by Different Methods
The comparison of the diameter of double-lumen tube at the cuff of endotracheal and endobronchial during the cuff was collapse or inflated as a guide for the selection of the size of double-lumen tube.
- Trial name
- NCT05739318
- Testing
- The cuff of endotracheal and endobronchial is collapsed, The cuff of endotracheal and endobronchial is inflated
- Where
- China
- Volunteers
- 60 people
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Placement of the Double-Lumen Tube Without Fiberoptic Bronchoscope Assistance
laryngoscope combined with chest CT in double lumen endotracheal tube accurate positioning
- Trial name
- NCT02943928
- Testing
- laryngoscope and chest CT image, traditional method by experience
- Where
- China
- Volunteers
- 60 people
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Compare a New Method and Formula as a Guide for the Intubation of a Left-sided Double-lumen Tube
One-lung ventilation (OLV) is required for the most of thoracic surgery to facilitate surgical visualization by collapsing the lung. The double-lumen tube (DLT) is the commonly used device for OLV.
- Trial name
- NCT03545737
- Testing
- Measurement, Formula
- Where
- China
- Volunteers
- 60 people, healthy volunteers welcome
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
The Length of the Right Main Stem Bronchus as a Guide to Right-sided Double-lumen Tube Use
The Length of the Right Main Stem Bronchus Measured by Computerised Tomography as a Guide to Right-sided Double-lumen Tube Use
- Trial name
- NCT04127903
- Testing
- the Length of Right Main Stem Bronchus
- Where
- China
- Volunteers
- 60 people
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Comparing the "Snifing Position" , "Simple Head Extension" and "Neutral Position"
The simple head extension is recommended for optimization of glottic visualization during Nasotracheal intubation via fiberoptic bronchoscope (FOB) .
- Trial name
- NCT05331287
- Testing
- Head position
- Where
- China
- Volunteers
- 60 people
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Comparing the "sniffing Position" , "Simple Head Extension" and "Neutral Position"
The simple head extension is recommended for optimization of glottic visualization during awake orotracheal intubation whith fiberoptic bronchoscope (FOB) .
- Trial name
- NCT02792855
- Testing
- sniffing Position(place a 7-cm cushion under head ), Simple Head Extension(without cushion)
- Where
- China
- Volunteers
- 75 people, healthy volunteers welcome
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
A Comparison the Intubation of a Left Sided Double Lumen Tube and Uniblocker
One-lung ventilation (OLV) is required for the most thoracic surgery to facilitate surgical visualization by collapsing the lung.
- Trial name
- NCT03392922
- Testing
- Uniblocker, Left-sided Double-lumen Tube
- Where
- China
- Volunteers
- 60 people
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Chest CT for the Placement of the Uniblocker
Video laryngoscope and chest CT iminge for the placement of the Uniblocker
- Trial name
- NCT03008473
- Testing
- video laryngoscope and chest CT iminge, Conventional intubation of uniblocker
- Where
- China
- Volunteers
- 70 people
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
An Innovative Approach for Uniblocker Intubation
To measure the distance between the upper edge of the thyroid cartilage to the upper edge of the sternum add the distance from the upper edge of the sternum to the carina was calculated according to the chest CT scans as a guide…
- Trial name
- NCT03392818
- Testing
- The measured distance, formula, Fiberoptic bronchoscope
- Where
- China
- Volunteers
- 90 people
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Comparison of Disposcope Endoscope and Fiberoptic Bronchoscope
The fiberoptic bronchoscope (FOB) has been the preferred instrument for many years in the management of difficult tracheal intubation, and it is considered as a gold standard.
- Trial name
- NCT02669550
- Testing
- Fiberoptic bronchoscope, Disposcope endoscope
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Extraluminal Use of the Bronchial Blocker of Univent Tube
intends to evaluate the feasibility and security issues of univent bronchial blockers outside the single lumen endotracheal tube for one- lung ventilation in left thoracic surgery patients.
- Trial name
- NCT02816918
- Testing
- Extraluminal use of Univent bronchial Blocker, Innerluminal use Univent bronchial Blocker
- Where
- China
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- The First Hospital of Qinhuangdao
Therapeutic Procedural Complication
Outcome and Risk Factors For Mortality in Peritoneal Dialysis Patients: 20 Years Experience in a Single Turkish Center
INTRODUCTION AND AIMS: The aims of this study were to evaluate patient and technique survival rates, investigate peritonitis rates and evaluate factors affecting mortality in peritoneal dialysis (PD) patients over a period of 20…
- Trial name
- NCT02922270
- Testing
- Peritoneal dialysis patients at the Istanbul Medical Faculty
- Volunteers
- 277 people
- Sponsor
- Istanbul University