Clinical trials: Thoracoabdominal Aortic Aneurysm
Juxtarenal Aortic Aneurysm, Pararenal Aneurysm
Clinical Outcomes and Major Adverse Events in Patients Treated With Physician-Modified Fenestrated and Branched Stent Grafts
The purpose of this study is to evaluate safety and effectiveness of endovascular treatment of juxtarenal, pararenal and thoracoabdominal aortic aneurysms (with or without iliac artery involvement) using physician-modified stent…
- Conditions
- Juxtarenal Aortic Aneurysm, Pararenal Aneurysm, Thoracoabdominal Aortic Aneurysm
- Trial name
- NCT06526676
- Testing
- Cook Alpha TX2 Stent Graft, Cook Zenith TX2, and Cook Zenith Fenestrated Stent Graft
- Where
- United States
- Volunteers
- 50 people
- Sponsor
- University of California, Los Angeles
Aortic Aneurysm, Aortic Aneurysm Abdominal
Prophylactic Suture Line Sealing With NE'X Glue R-eco in Cardiac and Vascular Surgery
This clinical study aims to evaluate the effectiveness and safety of using NE'X Glue R-eco to seal suture lines. The adhesive will be applied to reduce the risk of suture line bleeding in cardiac or vascular repair surgeries, a…
- Conditions
- Aortic Aneurysm, Aortic Aneurysm Abdominal, Valve Stenoses, Aortic, Valve Regurgitation, Mitral
- Trial name
- CLOSURE (NCT06918496)
- Testing
- Surgical placement of a prosthetic or biologic graft (patch), or an allograft for cardiac and (cardio)vascular repair.
- Where
- 2 sites in Belgium, Poland
- Volunteers
- 60 people
- Sponsor
- Grena Biomed Limited
Complex Aortic Aneurysms, Thoracoabdominal Aneurysms
Complex Aortic Aneurysm Repair Using Physician Modified Endografts and Custom Made Devices
The purpose of this study is to evaluate the safety and efficacy of custom made devices, Zenith t-Branch devices and physician modification of FDA approved off-the-shelf endovascular grafts in the treatment of patients with…
- Conditions
- Complex Aortic Aneurysms, Thoracoabdominal Aneurysms, Pararenal Aneurysms, Juxtarenal Aneurysms
- Trial name
- CARPE-CMD (NCT02050113)
- Testing
- Custom Made Fenestrated or Branched Stent Graft
- Where
- United States
- Volunteers
- 600 people
- Sponsor
- Andres Schanzer
Aortic Aneurysm, Thoracoabdominal, Thoracoabdominal Aortic Aneurysm
Evaluation of the Safety and Efficacy of the Multilayer Stent
Evaluation of the Multilayer Flow Modulator (MFM) for Endovascular Thoracoabdominal Aneurysm Repair. The objectives of the study is to determine the efficacy, safety and performance of the MFM and its delivery system in patients…
- Conditions
- Aortic Aneurysm, Thoracoabdominal, Thoracoabdominal Aortic Aneurysm, Aortic Aneurysm, Thoracic
- Trial name
- STRATO (NCT01756911)
- Testing
- MFM
- Where
- 9 sites in France
- Volunteers
- 23 people
- Sponsor
- Cardiatis
Thoracoabdominal Aortic Aneurysms
CUstodiol Versus RInger: whaT Is the Best Agent?
Postoperative renal failure is the most significant risk factor for early mortality after elective surgical repair of thoracoabdominal aortic aneurysms (TAAAs).
- Trial name
- NCT02327611
- Testing
- Custodiol, Enriched Ringer's lactate solution
- Where
- Italy
- Volunteers
- 90 people
- Sponsor
- Scientific Institute San Raffaele
Juxtarenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
Modified Preloaded System for Renal Arteries in Fenestrated Endografting (MPSRA)
Advanced Endovascular repair of aneurysms and dissections involving thoraco-abdominal (type I-IV) and complex abdominal (juxta and para-renal) aorta is a ground-gaining procedure allowing favorable results in high surgical risk…
- Conditions
- Juxtarenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm, Pararenal Aortic Aneurysm, Aortic Aneurysm, Thoracoabdominal
- Trial name
- MPSRA (NCT05224219)
- Where
- Italy
- Volunteers
- 35 people
- Sponsor
- University of Bologna
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Thoracic
Endovascular Treatment of TAAA and Aortic Arch Aneurysms Using Fenestrated and Branched Stent Grafts
Prospective, nonrandomized, single-center, two-arm study to assess the feasibility and safety and to evaluate clinical outcomes of endovascular repair of complex aortic aneurysms (thoracoabdominal aortic aneurysms and aortic arch…
- Conditions
- Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Thoracic, Aortic Dissection, Thoracoabdominal
- Trial name
- NCT02323581
- Testing
- Endovascular treatment of Thoracoabdominal Aortic Aneurysm, Endovascular treatment of Aortic Arch Aneurysms
- Where
- 2 sites in United States
- Volunteers
- 520 people
- Sponsor
- Darren Schneider, M.D.
Thoracoabdominal Aortic Aneurysm
Thoracoabdominal Aortic Aneurysms
Evaluation of the effectiveness of the different modalities for treatment of thoracoabdominal aortic aneurysms. FEVAR and BEVAR devices are widely used now due to its feasability and wide range of use .
- Trial name
- NCT06267573
- Testing
- Fenestrated and branched endovascular devices for TAAA
- Volunteers
- 100 people
- Sponsor
- Assiut University
Aortic Aneurysm, Abdominal, Juxtarenal Aortic Aneurysm
Zenith® Fenestrated+ Clinical Study
The Zenith® Fenestrated+ Endovascular Graft Clinical Study will assess the safety and effectiveness of the Zenith® Fenestrated+ Endovascular Graft (ZFEN+) in combination with the BeGraft Balloon-Expandable FEVAR Bridging Stent…
- Conditions
- Aortic Aneurysm, Abdominal, Juxtarenal Aortic Aneurysm, Extent IV Thoracoabdominal, Pararenal Aneurysm
- Trial name
- NCT04875429
- Testing
- Zenith Fenestrated+ Endovascular Graft in combination with the BeGraft Balloon-Expandable FEVAR Bridging Stent Graft System and Unibody2
- Where
- 33 sites in United States, United Kingdom
- Volunteers
- 105 people
- Sponsor
- Cook Research Incorporated
Complex Aortic Aneurysms, Thoracoabdominal Aneurysm
Real-World Data Collection of GORE Devices Used In the Endovascular Treatment of Aortic Aneurysms Which Incorporate Visceral Arteries.
The registry population consists of patients presenting with complex aortic pathologies amenable to endovascular aortic repair that requires the incorporation of bridging stents to maintain visceral artery perfusion
- Conditions
- Complex Aortic Aneurysms, Thoracoabdominal Aneurysm, Fenestrated Endovascular Aortic Repair, Endovascular Aortic Repair
- Trial name
- ENVISION (NCT07480395)
- Where
- 26 sites in Austria, Denmark and 8 more
- Volunteers
- 400 people
- Sponsor
- W.L.Gore & Associates
Type B Acute Aortic Syndrome, Thoracic and Thoracoabdominal Aneurysms With Crawford Extent I, II, III, or IV
A Standard Carbon Dioxide Flushing Protocol to Reduce Air Embolization During Thoracic Endovascular Aortic Repair
FlushTEVAR is a non-profit, interventional, randomized, controlled, single-blind, national multicenter study promoted by the University of Bologna and coordinated by the Vascular Surgery Unit of IRCCS Azienda…
- Trial name
- FlushTEVAR (NCT07734584)
- Testing
- Carbon dioxide pre-implant endograft flushing followed by saline flushing, Saline endograft flushing
- Where
- 4 sites in Italy
- Volunteers
- 90 people
- Sponsor
- University of Bologna
Pararenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
PMEG for Repair of Pararenal and Thoracoabdominal Aortic Aneurysm
The primary objective is to evaluate the safety and effectiveness of surgeon modified endografts for the treatment of pararenal and thoracoabdominal aortic pathology in patients who are not candidate for traditional open repair…
- Trial name
- NCT05195905
- Testing
- PMEG
- Where
- United States
- Volunteers
- 300 people
- Sponsor
- Konstantinos Arnaoutakis, MD
Thoracoabdominal Aortic Aneurysm, Pararenal Aortic Aneurysm
TAMBE Japan Post-Marketing Surveillance
To evaluate the safety and efficacy of multi component system (TAMBE device) including GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis (Aortic Component; AC) under post-marketing use.
- Trial name
- NCT07147569
- Testing
- GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis
- Where
- 5 sites in Japan
- Volunteers
- 100 people
- Sponsor
- W.L.Gore & Associates
Thoracoabdominal Aortic Aneurysm, Paravisceral Abdominal Aortic Aneurysm
Endovascular Exclusion of Thoracoabdominal and/or Paravisceral Abdominal Aortic Aneurysm
This is a study to assess the safety and effectiveness of endovascular treatment of thoracoabdominal (TAAA) and paravisceral abdominal (PVAAA) aortic aneurysms.
- Trial name
- NCT00483249
- Testing
- Endovascular Branched Stent-Graft
- Where
- 2 sites in United States
- Volunteers
- 250 people
- Sponsor
- Warren J. Gasper, MD
Toraco Abdominal Aneurysm
Clinical Study on the Prevention of Surgical Wound Complications for Aneurysmal Thoracic-abdominal Aortic Pathology Using the "PREVENA" System
The patients will be randomized into two groups of 100 subjects each one. One arm will be randomized to treatment with a negative topical pressure system (Sistema Prevena ™); while the other arm ("control group") will be…
- Trial name
- TVAC (NCT03512470)
- Testing
- Sistema Prevena ™(TVAC), Standard medication
- Where
- Italy
- Volunteers
- 100 people
- Sponsor
- IRCCS San Raffaele
Complex Abdominal Aortic Aneurysm, Juxtarenal Aortic Aneurysm
Physician Modified Endograft For Complex Aortic Aneurysm Repair
The physician modified endograft is intended for treating complex, pararenal, juxtarenal and thoracoabdominal aortic aneurysms requiring coverage of renal arteries, the superior mesenteric artery or the celiac trunk in high-risk…
- Conditions
- Complex Abdominal Aortic Aneurysm, Juxtarenal Aortic Aneurysm, Pararenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
- Trial name
- NCT05339061
- Testing
- Endovascular Treatment of Complex abdominal or Thorocoabdominal aneurysms (TAAA).
- Where
- United States
- Volunteers
- 40 people
- Sponsor
- University of California, Davis
Aortic Aneurysm, Thoracoabdominal, Aortic Diseases
Standardized Physician-modified Fenestrated Endograft Registry
Multicenter retrospective study including all consecutive patients treated by PMEG using a standard modification technique of Valiant Captivia (Medtronic, Minneapolis, MN-USA).
- Trial name
- SPHERE (NCT06358248)
- Testing
- Physician-modification of Valiant Captivia Endograft (Medtronic, Minneapolis, MN-USA).
- Where
- Italy
- Volunteers
- 50 people
- Sponsor
- University Hospital Padova
Thoracoabdominal Aortic Aneurysm, Aortic Arch Aneurysm
Evaluation of Branch Endografts in the Treatment of Aortic Aneurysms
Zenith t-Branch Study Cohort: The purpose of this study is to collect information on the Cook Zenith t-Branch endovascular stent-graft system and the Terumo Arch Branch for the treatment of aortic aneurysms.
- Trial name
- NCT01524211
- Testing
- Zenith® t-Branch, Terumo Arch Branch
- Where
- United States
- Volunteers
- 235 people
- Sponsor
- Baptist Health South Florida
Abdominal Aortic Aneurysm, Pararenal Aortic Aneurysm
GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis Post-Approval Study
This study aims to confirm that the benefit-risk assessment of the GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis (TAMBE Device) remains positive in real-world use and to ensure the adequacy of the TAMBE Device training…
- Conditions
- Abdominal Aortic Aneurysm, Pararenal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
- Trial name
- NCT06578741
- Testing
- GORE® EXCLUDER® Thoracoabdominal Branch Endoprosthesis (TAMBE Device)
- Where
- United States
- Volunteers
- 310 people
- Sponsor
- W.L.Gore & Associates
Sedation, Respiration, Artificial
Dexmedetomidine for Postoperative Sedation in Patients Undergoing Repair of Thoracoabdominal Aortic Aneurysms
The primary objective of this study is to test the hypothesis that time on the ventilator and ICU length of stay will be shorter in TAA patients given postoperative sedation with dexmedetomidine compared to those given standard…
- Conditions
- Sedation, Respiration, Artificial, Length of Stay
- Trial name
- NCT00409344
- Testing
- Dexmedetomidine, Normal Saline
- Where
- United States
- Volunteers
- healthy volunteers welcome
- Sponsor
- Massachusetts General Hospital