Heart FailurePhase 1NMT-CTNCT00491777
Correlation Research Study: IQ2, NcIQ and IQ101
A Phase 1 study testing Noninvasive Hemodynamic Patient Monitor in people with Heart Failure and Dyspnea, run by Noninvasive Medical Technologies, Inc..
Trial summary
The new NcIQ thoracic impedance monitor is based on the predicate device, the IQ101. The new model uses the same 3-dimensional signal averaging as the original device, but also include second radio frequency signal to permit the device to work "wirelessly", i.e., without electrode lead attachments to the patient. Read more about this study
- Who is it for?
- Ages 18 to 85 yearsHealthy volunteers can take part
- Conditions the study is for
- Heart Failure, Dyspnea, Hypertension
- What is being tested?
- Noninvasive Hemodynamic Patient Monitor
- Type of treatment
- Medical device
- How many people
- 25 participants
- Where
- No sites listed yet
- Study dates
- Jun 2007to Jun 2007
- Phase
- Phase 1
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Age - 18-80 years
- Weight - 80-300 pounds
- Height - 5.0 feet - 6feet 4 inches Exclusion Criteria
- Ongoing medical emergency or acute medical illness
- NcIQ or ECG electrode adhesive allergy or sensitivity
Who cannot join
None listed.
About this study
Official title: Correlation Study of NMT's IQ2, NcIQ and Its' Predicate Technology, IQ101.
The new NcIQ thoracic impedance monitor is based on the predicate device, the IQ101. The new model uses the same 3-dimensional signal averaging as the original device, but also include second radio frequency signal to permit the device to work "wirelessly", i.e., without electrode lead attachments to the patient. This study seeks to 1) validate the use of the new device and confirm the correlation of the IQ101 and NcIQ. 2) Evaluate the ease of the new device.
The new IQ2 thoracic impedance monitor is based on the predicate device, the IQ101. The new model uses the same 3-dimensional signal averaging as the original device, but with smaller housing and updated operating software. This study seeks to 1) Validate the use of the new device and confirm the correlation of the IQ101 and IQ2. 2) Compare the ease of the devices.
Read the detailed description
The IQ101 is the first generation of the non invasive cardiograph. This device uses impedance to a micro-electric field passing from the electrodes. The NcIQ uses Radio frequencies and the same 3 dimensional signal averaging algorithm used in the IQ101 to generate hemodynamic data. The radio waves enables the device to work without the contact lead arrays used in the IQ2 and can take measurements without even contacting the patient, hence can be applied through clothing and is simple to apply. This makes the potential use by first responders a possibility. The device measures the change in the radio wave reflection during the cardiac cycle to estimate ardiac function. Specifically, it measures cardiac output, the amount of blood pumped per minute, and other hemodynamic parameters previously only measurable with invasive catheters. The data us used to generate a LIFESCORE and can measure and report dangerous trends to the caretaker. The device has a companion device to download the data for the hospital providers to create a seamless transfer of care. The new device uses technology similar to the previous generation machine but has been miniaturized, given updated operating system, and newer computer technology that helped make the device smaller, and faster. The underlying patented algorithm was not changed. Therefore, it is expected to provide the same degree of accuracy and precision as the predicate device.
The IQ101 is the first generation of the non invasive cardiograph. This device uses impedance to a micro-electric field passing from the electrodes. The device can use the impedance and the change in the impedance during the cardiac cycle to estimate thoracic fluid volumes and cardiac function. Specifically, it measures cardiac output, the amount of blood pumped per minute, and other hemodynamic parameters previously only measurable with invasive catheters. There are many studies documenting the device's performance. The new device uses the same technology but has been modernized with updated operating system, and newer computer technology that helped make the device smaller, and faster. The device has also been redesigned to make operator use simpler and reduce the number wires involved. The underlying patented algorithm was not changed. Therefore, it is expected to provide the same degree of accuracy and precision as the predicate device with simplified user interface and lighter, smaller, more portable housing to improve ease of use.
- Conditions
- Heart Failure, Dyspnea, Hypertension, Pacemaker, Trauma
- Being tested
- Noninvasive Hemodynamic Patient Monitor
- Keywords
- Noninvasive, Hemodynamic, Monitoring, Critical Care, Swan-Ganz
- Medical subject headings
- Heart Failure, Dyspnea, Hypertension, Wounds and Injuries
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Noninvasive Hemodynamic Patient MonitorDevice
What is being measured
The primary outcome is the main question the study is designed to answer.
A direct correlation between output parameters of IQ2/NcIQ to IQ101
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Jun 2007 (estimated)
- Study startJun 2007
- Study completionJun 2007
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Heart FailureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 1
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 25 participants (actual)
Sponsor and investigators
- Lead sponsor
- Noninvasive Medical Technologies, Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- University of Florida, Shand's Medical Center
- Investigators
- Kevin Ferguson, MD, Study chair, Shand's HospitalJoseph A Tyndall, MD, Principal investigator, Shand's HospitalDavid Seaberg, MD, Study director, Shand's Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00491777
- Sponsor's protocol ID
- NMT-IQ2/NcIQ
- Acronym
- NMT-CT
- Status last verified
- Jun 2007
- First submitted
- 22 Jun 2007
- Last updated
- 26 Jun 2007
- Results posted
- No
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 26 Jun 2007. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Correlation Study of NMT's IQ2, NcIQ and Its' Predicate Technology, IQ101.
- ClinicalTrials.gov ID
- NCT00491777
- Acronym / sponsor ID
- NMT-CT / NMT-IQ2/NcIQ
- Conditions
- Heart Failure, Dyspnea, Hypertension, Pacemaker, Trauma
- Keywords
- Noninvasive, Hemodynamic, Monitoring, Critical Care, Swan-Ganz
- Phase
- Phase 1
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 25 participants (actual)
- Lead sponsor
- Noninvasive Medical Technologies, Inc.Industry (pharma, biotech, devices)
- Collaborators
- University of Florida, Shand's Medical Center
- Study start
- Jun 2007
- Study completion
- Jun 2007 (actual)
- First posted
- 26 Jun 2007 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The new NcIQ thoracic impedance monitor is based on the predicate device, the IQ101. The new model uses the same 3-dimensional signal averaging as the original device, but also include second radio frequency signal to permit the device to work "wirelessly", i.e., without electrode lead attachments to the patient. This study seeks to 1) validate the use of the new device and confirm the correlation of the IQ101 and NcIQ. 2) Evaluate the ease of the new device.
The new IQ2 thoracic impedance monitor is based on the predicate device, the IQ101. The new model uses the same 3-dimensional signal averaging as the original device, but with smaller housing and updated operating software. This study seeks to 1) Validate the use of the new device and confirm the correlation of the IQ101 and IQ2. 2) Compare the ease of the devices.
Detailed description
The IQ101 is the first generation of the non invasive cardiograph. This device uses impedance to a micro-electric field passing from the electrodes. The NcIQ uses Radio frequencies and the same 3 dimensional signal averaging algorithm used in the IQ101 to generate hemodynamic data. The radio waves enables the device to work without the contact lead arrays used in the IQ2 and can take measurements without even contacting the patient, hence can be applied through clothing and is simple to apply. This makes the potential use by first responders a possibility. The device measures the change in the radio wave reflection during the cardiac cycle to estimate ardiac function. Specifically, it measures cardiac output, the amount of blood pumped per minute, and other hemodynamic parameters previously only measurable with invasive catheters. The data us used to generate a LIFESCORE and can measure and report dangerous trends to the caretaker. The device has a companion device to download the data for the hospital providers to create a seamless transfer of care. The new device uses technology similar to the previous generation machine but has been miniaturized, given updated operating system, and newer computer technology that helped make the device smaller, and faster. The underlying patented algorithm was not changed. Therefore, it is expected to provide the same degree of accuracy and precision as the predicate device.
The IQ101 is the first generation of the non invasive cardiograph. This device uses impedance to a micro-electric field passing from the electrodes. The device can use the impedance and the change in the impedance during the cardiac cycle to estimate thoracic fluid volumes and cardiac function. Specifically, it measures cardiac output, the amount of blood pumped per minute, and other hemodynamic parameters previously only measurable with invasive catheters. There are many studies documenting the device's performance. The new device uses the same technology but has been modernized with updated operating system, and newer computer technology that helped make the device smaller, and faster. The device has also been redesigned to make operator use simpler and reduce the number wires involved. The underlying patented algorithm was not changed. Therefore, it is expected to provide the same degree of accuracy and precision as the predicate device with simplified user interface and lighter, smaller, more portable housing to improve ease of use.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- None (open label)
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Age - 18-80 years
- Weight - 80-300 pounds
- Height - 5.0 feet - 6feet 4 inches Exclusion Criteria
- Ongoing medical emergency or acute medical illness
- NcIQ or ECG electrode adhesive allergy or sensitivity
Key exclusion criteria (0 listed)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Noninvasive Hemodynamic Patient Monitor | Device | – |
Primary outcome
A direct correlation between output parameters of IQ2/NcIQ to IQ101
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 26 Jun 2007.
Related trials for Heart Failure
RecruitingPhase 2/3
Efficacy, Safety, and Pharmacokinetics of Vericiguat in Pediatric Participants With Heart Failure Due to Left Ventricular Systolic Dysfunction (MK-1242-036)
Heart Failure, Left Ventricular Systolic Dysfunction
RecruitingPhase 1/2
HS235 Study in Overweight and Obese Participants With Combined Pre and Post-Capillary Pulmonary Hypertension Due to Heart Failure With Preserved Ejection Fraction
Pulmonary Hypertension, Heart Failure With Preserved Ejection Fraction
Active, not recruiting
Heart Failure Patient Management and Interventions Using Continuous Patient Monitoring Outside Hospitals and Real-world Data
Chronic Heart Failure, Heart Transplant Recipient
Enrolling by invitationObservational study
Multi-Scale Analysis of Phenotypes in Heart Failure (MAP-HEART)
Heart Failure
Not yet recruitingObservational study
Real-world Effectiveness and Safety of Savagen (Sacubitril/Valsartan) in Malaysian HFrEF Patients
Heart Failure With Reduced Ejection Fraction (HFrEF), Heart Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Kevin Ferguson, MD study chair
Shand's Hospital
Joseph A Tyndall, MD principal investigator
Shand's Hospital
David Seaberg, MD study director
Shand's Hospital
Questions about this trial
What is this clinical trial studying?
A Phase 1 study testing Noninvasive Hemodynamic Patient Monitor in people with Heart Failure and Dyspnea, run by Noninvasive Medical Technologies, Inc..
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 0 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 26 Jun 2007. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 1 studies test a treatment in a small group of people for the first time or in a new way, mainly to check safety and find the right dose.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
A direct correlation between output parameters of IQ2/NcIQ to IQ101. It is what the study was designed to measure, not a finding.