A study testing Non-Electric Infant Warmer in people with Hypothermia Neonatal, run by Boston Children's Hospital at 1 site in Rwanda.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

Hypothermia contributes to a significant portion of neonatal deaths. Kangaroo mother care (KMC) is a safe and effective method of warming; however, it is not always feasible, and not possible in settings such as resuscitation or clinical instability. Read more about this study

Who is it for?
Ages Up to 3 months
Conditions the study is for
Hypothermia Neonatal
What is being tested?
Non-Electric Infant Warmer
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
130 participants
Where
1 siteRwanda
Study dates
Jul 2016to Jul 2019
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 3 months
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Any infant with the following criteria for whom caregiver is not available for Kangaroo Mother Care, or Kangaroo Mother Care is not adequate (less than ½ degree Celsius per hour rise in temperature).
  • axillary temperature < 36 degrees C and ≥35 degrees C 1a) If an electric warmer is available and the infant's temperature is < 35 degrees C, then the infant would start by being warmed on the electric warmer until the infant's temperature reaches 36 degrees C, then can start non-electric infant warmer use
  • Infants at-risk for hypothermia (criteria: estimated post-menstrual age of < 35 weeks or current body weight of < 2.5 kg)

Who cannot join

  • Any infant whose family is unwilling to consent to study.
  • Mothers who are critically ill at the time of infant eligibility or deemed not medically stable by nursing staff to be approached for consent.
  • Any infant with a contraindication to Kangaroo Mother Care (medical instability) and electrical heating source available.
  • Any infant with initial temperature < 35 degrees C and electrical heating source available.
  • Infants within the first hour of admission to neonatal unit or first hour of life in maternity.
  • Infants requiring phototherapy
Show all 16Show fewer
  • Infants with significant skin condition
  • Infants with Hypoxic Ischemic Encephalopathy (HIE)
  • Stopping Criteria:
  • If an electric heating source is available, the infant will be taken off the study and warmed with an appropriate source of electric heat if the infant:
  • Is hypothermic and temperature decreases on any measurement
  • Is hypothermic and temperature does not begin to rise within 30 minutes
  • Is hypothermic and not heating at a rate of > ½ degree C per hour until temperature is >36.5 degrees C
  • Has a temperature that falls below 36 degrees C despite maximum exposure to the heat source
  • Is ever considered to be too severely ill by the medical team to be safely cared for in the non-electric infant warmer.
  • The warmer will be removed once its temperature drops below 36 degrees, and/or the phase change material begins to harden.

Trial locations and contacts

1 site in 1 country.

Rwanda1 site
  • Dr Evrard Nahimana

    Rwinkwavu

Other trials in Rwanda

About this study

Hypothermia contributes to a significant portion of neonatal deaths. Kangaroo mother care (KMC) is a safe and effective method of warming; however, it is not always feasible, and not possible in settings such as resuscitation or clinical instability. Electric warmers are the standard of care in developed countries, but are extremely costly, complicated with risk of causing both hypo and hyperthermia with misuse, and often not feasible in settings without stable electricity. Through a multi-institutional collaboration, the investigators have developed an electricity-free infant warmer. After laboratory based prototype testing for safety and efficacy, the investigators aim to study the supervised use of the warmer under routine implementation conditions in a resource-limited setting.

Read the detailed description

Hypothermia contributes to a significant portion of neonatal deaths. Kangaroo mother care (KMC) is a safe and effective method of warming; however, it is not always feasible, and not possible in settings such as resuscitation or clinical instability. Electric warmers are the standard of care in developed countries, but are extremely costly, complicated with risk of causing both hypo and hyperthermia with misuse, and often not feasible in settings without stable electricity. Through a multi-institutional collaboration, the investigators have developed an electricity-free infant warmer. After laboratory based prototype testing for safety and efficacy, the investigators aim to study the supervised use of the warmer under routine implementation conditions in a resource-limited setting. The primary aim of Phase 1 is to determine if the infant warmer is a safe, effective, usable and functional addition to KMC. This is planned in a convenience sample of patients in two district hospitals, one in a relatively warm environment, and one in a colder setting using quantitative methods and observer audits of usability and functionality. After determination of safety and effectiveness and making any necessary modifications to the warmer, Phase 2 aims to study the warmer in rural health centers and transport, as this is where we ultimately aim to use the electricity free devices due to the limited access to functioning and stable electricity in these settings. The overall goal of the project is dissemination of the study results, and ultimately the infant warmer to the district and national level for key policy makers and stakeholders, as well as globally via publication.

Being tested
Non-Electric Infant Warmer
Keywords
Hypothermia, Infant Warmer
Medical subject headings
Hypothermia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Non-Electric Infant WarmerDevice

    Electric warmers are the standard of care in developed countries, but are extremely costly, complicated with risk of causing both hypo and hyperthermia with misuse, and often not feasible in settings without stable electricity. Through a multi-institutional collaboration, the investigators have developed an electricity-free infant warmer.

Study groups in NCT03031431
Study groupRoleWhat they receive
Non-Electric Infant WarmerExperimentalIn line with current recommended practice, mothers will be encouraged to provide Kangaroo Mother Care (KMC) whenever possible. If an infant's temp is not rising by ½ degree C per hour with KMC alone, the infant warmer will be offered as an addition by the study team. If the mother is not available for KMC at any time, the infant will be warmed exclusively with the warmer. Bundling in clothes will only be used in addition to the warmer per carer preference. Temp measurement of the infant, warmer, and ambient air will be measured every 15 mins for the first hr, then hrly and as needed for the remainder of use or until warmer endpoint is reached (warmer temp below 36 degrees or phase-change material hardens [soft, semisoft, or hardened]).
Receives: Device: Non-Electric Infant Warmer

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Temperature/Effectiveness

    The infant warmer will be evaluated on the number of time is able to successfully achieve and maintain a normal body temperature for patients who are hypothermic and those patients at risk of hypothermia because of a < 2.5 kg birth weight or < 35 week gestational age.

    Measured: Up to 6 months

Secondary outcomes (3)
  1. Usability

    The investigators will use observation to evaluate the usability of the warmer by assessing whether or not the infant warmer was used in a way that deviated from its recommended use.

    Measured: Up to 6 months

  2. Functionality

    The functionality will be assessed by whether or not there appeared to be wear and tear on the infant warmer based on repeated use.

    Measured: Up to 6 months

  3. Qualitative Survey

    The same as primary outcome and secondary outcome as described above with the setting being clinic and transport based rather than in a hospital, and with the addition of qualitative questions for mother and nurse regarding infant warmer use.

    Measured: Up to 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Jan 2017 (estimated)
  2. Study startJul 2016
  3. Primary completionDec 2018
  4. Study completionJul 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
130 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03031431
Sponsor's protocol ID
IRB-P00016205
Status last verified
Jan 2020
First submitted
13 Dec 2016
Last updated
13 Jan 2020
Data monitoring committee
Yes
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in