Clinical trials: Bracket Bonding
Orthodontics, Bracket Bonding
Indirect Bonding Accuracy of 3D Printed Digital Transfer Trays
The goal of this study is to compare the bracket transfer accuracy of two frequently used 3D printed indirect bonding trays. This is an interventional study. Participants have 3-6mm crowding without tooth loss and deformity.
- Conditions
- Orthodontics, Bracket Bonding, Indirect Bonding, Digital Indirect Bonding Transfer Tray
- Trial name
- NCT06167278
- Testing
- Indirect bonding with two different digital bracket bonding transfer tray
- Where
- Turkey (Türkiye)
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Marmara University
Orthodontics, Bracket Bonding
Comparison of Bond Failure with Resin-modified Glass Ionomer Cement and Visible Light-cure Composite Bonding Material in Adult Orthodontic Patients - a Split-Mouth, Randomized Controlled Trial
In this split mouth study design, 34 orthodontic patients coming for fixed appliance treatment will be bonded with standard light-cure composite bonding material and intervention of Resin Modified Glass Ionomer Cement (RMGIC).
- Conditions
- Orthodontics, Bracket Bonding, Malocclusion; Displaced or Missing Teeth
- Trial name
- RMGIC (NCT06602154)
- Testing
- Resin modified glass ionomer
- Where
- 2 sites in Pakistan
- Volunteers
- 37 people, healthy volunteers welcome
- Sponsor
- Aga Khan University Hospital, Pakistan
Bracket Bonding, Digital Application
ACCURATE ORTHODONTIC BRACKETS POSITIONING WITH OR WITHOUT DENTAL MAGNIFYING LOUPES
The goal of this clinical trial is to assess the accuracy of bracket positioning on tooth facial axis of clinical crown with dental loupes (L) or without dental loupes (NL) on orthodontic patients.
- Conditions
- Bracket Bonding, Digital Application, Technology-enhanced Learning
- Trial name
- NCT07134803
- Testing
- Bonding of the orthodontic brackets with dental loupe with Zumax Dental loupes DFK Angled Loupe with a magnification of x3.0 and focus depth of 42cm
- Where
- Malaysia
- Volunteers
- 18 people, healthy volunteers welcome
- Sponsor
- University of Malaya
Orthodontic Appliance Complication, Malocclusion
Comparison of Precision in Brackets Position in Two Indirect Bonding Materials
Objective: To compare the cementation precision of self-ligating brackets between two indirect bonding materials: polyvinylsiloxane and thermal glue. Methods: Split-mouth randomized clinical trial study, with 15 participants.
- Trial name
- IDBmaterials (NCT05483114)
- Testing
- Accuracy of indirect bonding of self-ligating brackets made with polyvinylsiloxane transfers, Accuracy of indirect bonding of self-ligating brackets made with thermal glue transfers
- Volunteers
- 15 people, healthy volunteers welcome
- Sponsor
- Fundación Universitaria CIEO
Dental Bonding, Orthodontic Brackets
Segmented Indirect Versus Direct Bracket Bonding
This randomized clinical trial compared two methods of attaching orthodontic brackets to teeth: conventional direct bonding, in which each bracket is placed and bonded individually in the mouth, and a segmented modified indirect…
- Trial name
- NCT07861178
- Testing
- Direct bonding, Segmented modified indirect bonding
- Where
- Saudi Arabia
- Volunteers
- 18 people, healthy volunteers welcome
- Sponsor
- Riyadh Elm University
Malocclusion
A Comparison of the Alignment Achieved Using Computer-guided Indirect Bonding of Orthodontic Brackets to Conventional Appliance Placement
Technological advances have made computer aided orthodontic treatment planning possible. 3D dental scanners and software make it possible to design and approve the outcome before treatment begins.
- Trial name
- NCT02221856
- Testing
- Motion View, Conventional Orthodontic Treatment
- Where
- United States
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Harvard School of Dental Medicine
Bracket Failure, Bracket Bonding
Comparison of Bond Failure Rate of Orthodontic Brackets Bonded With V-Prep and Resin-Modified Glass Ionomer Cement Versus Conventional Acid-Etch Composite Resin
Ethical approval will be obtained by the FUSH and informed consent will be obtained from individual patients/guardians in writing.
- Conditions
- Bracket Failure, Bracket Bonding, RMGIC, Conventional Bracket Bonding
- Trial name
- NCT07828431
- Testing
- V-Prep and Resin-Modified Glass Ionomer Cement, Conventional Acid-Etch Composite Resin
- Where
- Pakistan
- Volunteers
- 80 people, healthy volunteers welcome
- Sponsor
- Foundation University Islamabad
Augmented Reality
Augmented Reality-Assisted Bonding Versus Digitally-Assisted Indirect Bonding in Orthodontic Patients
Comparing two indirect bonding techniques. Augmented Reality-assisted bonding and Digital 3D printed indirect bonding trays in regards to patient convenience, accuracy of bracket placement and time consumption of each technique…
- Trial name
- NCT04658446
- Testing
- Augmented Reality-Assisted Indirect Bonding, Digitally-Asssited Indirect Bonding
- Volunteers
- 8 people, healthy volunteers welcome
- Sponsor
- Seif El-Din Amr Hussein Hegab
Orthodontic Brackets
Digital Bonding vs. Direct Bonding Study
This is a prospective, 2-armed, randomized, multi-site clinical study to demonstrate that digital bonding is a more efficient treatment method than direct placement of brackets.
- Trial name
- NCT06266130
- Testing
- Treatment Group Digital Bonding Tray, Control Group Direct Bonding
- Where
- 5 sites in United States
- Volunteers
- 138 people, healthy volunteers welcome
- Sponsor
- Solventum Orthodontics Corporation
Malocclusion
Evaluation of a "Flash-free" Adhesive Resin for Orthodontic Bracket Bonding
The purpose of this study is to compare bonding time, bond survival, amount of adhesive remaining on the tooth surface after bracket debonding, and time required for adhesive remnant cleanup between a new "flash-free" and a…
- Trial name
- NCT02030002
- Testing
- APC Flash-Free Adhesive Coated Appliance System, APC II Adhesive Coated Appliance System
- Where
- United States
- Volunteers
- 49 people, healthy volunteers welcome
- Sponsor
- University of Minnesota
Dental Etching, Dental Bonding
Comparison of Orthodontic Bracket Bond Failure Using Acid Etching With or Without Sandblasting
The goal of this clinical trial is to assess if sandblasting before acid etching reduce orthodontic bracket bond failure in fixed orthodontic treatment.
- Conditions
- Dental Etching, Dental Bonding, Acid Etching, Acid Etching, Dental
- Trial name
- AE SBE BF BB (NCT07617480)
- Testing
- Sandblasting with acid etching vs Acid etching alone, Acid Etching only
- Where
- Bangladesh
- Volunteers
- 15 people, healthy volunteers welcome
- Sponsor
- Tanzila Rafique
Orthodontic Appliance Complication
The Validity of Customized Orthodontic Bracket Set up
CAD/CAM systems have assisted orthodontists in planning and positioning brackets to minimize errors and improve the excellence of treatment.
- Trial name
- NCT05549089
- Testing
- Insignia™ twin brackets, Maestro® 3D Ortho Studio software (Discovery, Dentaurum®, Ispringen, Germany), Ray set® device (Discovery, Dentaurum®, Ispringen, Germany)
- Where
- Iraq
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Ammar Alubaydi
Dental Malocclusion
Eighteen-month Orthodontic Bracket Survival Rate With the Conventional Bonding Technique Versus RMGIC and V-prep
The aim of this study was to evaluate over eighteen months the clinical bonding failure and survival rates of the conventional bonding technique using the Transbond XT (3M Unitek, Monrovia, California, USA) and the RMGIC Fuji…
- Trial name
- NCT05939102
- Testing
- v-prep combined with RMGIC for bracket bonding, Conventional bracket bonding technique
- Where
- Lebanon
- Volunteers
- 25 people, healthy volunteers welcome
- Sponsor
- Saint-Joseph University
Orthodontic Appliances, Fixed
Computer-aided Indirect Bonding Versus Traditional Direct Bonding of Brackets in Orthodontic Patients
Accurate bracket positioning is one of the keys for effective orthodontic treatment. Traditionally, orthodontic brackets are positioned one-by-one on the teeth of the patient, with the so-called direct bonding method.
- Trial name
- NCT04395625
- Testing
- Direct bonding of Orthodontic brackets, Indirect bonding of Orthodontic brackets
- Volunteers
- 37 people, healthy volunteers welcome
- Sponsor
- University of Aarhus
Bracket Failure Rate, Bonding Time Per Bracket
Is a Primer Needed for Orthodontic Bonding? A Multi-centre Trial
Orthodontic treatment is carried out by placing fixed attachments(brackets)on teeth with wires which run through them and create tooth movement.
- Conditions
- Bracket Failure Rate, Bonding Time Per Bracket, Adhesive Remnant Index for Type of Bond Failure, Length of Treatment
- Trial name
- NCT01782521
- Testing
- No primer
- Volunteers
- 156 people, healthy volunteers welcome
- Sponsor
- Bradford Teaching Hospitals NHS Foundation Trust
White Spot Lesions, Enamel Demineralization
A Novel Remineralizing Self-Etch Primer for Orthodontic Bracket Bonding
This randomized clinical trial aims to evaluate the clinical effectiveness of a remineralizing self-etch primer used for orthodontic bracket bonding.
- Trial name
- NCT07291830
- Testing
- Remineralizing self-etch primer (M-SEP, SEP 1), Standard self-etch primer (P-SEP, SEP 2)
- Where
- Iraq
- Volunteers
- 45 people, healthy volunteers welcome
- Sponsor
- University of Baghdad
Bracket Bonding, Orthodontic Treatment
A Split-Mouth Clinical Trial Evaluating the Bond Failure Rate of a New Etch-Free Orthodontic Adhesive
This randomized, split-mouth clinical trial will evaluate a new orthodontic adhesive that eliminates the need for acid etching before bracket bonding.
- Conditions
- Bracket Bonding, Orthodontic Treatment, Dental Adhesives/Restorations Performance, White Spot Lesion of Tooth
- Trial name
- NCT07091422
- Testing
- Etch-Free Adhesive, Conventional Etch-and-Bond Adhesive
- Where
- United States
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- University of Maryland, Baltimore
Bracket Bonding
Orthodontic Bracket Bonding
Accurate bracket positioning is crucial for effective fixed orthodontic treatment and a core component of orthodontic specialist training. Clinically, two main bonding techniques exist: direct and indirect.
- Trial name
- OBB (NCT06685614)
- Testing
- orthodontic bracket bonding
- Volunteers
- 220 people, healthy volunteers welcome
- Sponsor
- National Taiwan University Hospital
Orthodontic Treatment, Bracket Failure
Comparison of One-Step and Two-Step Light Curing of Bonding Agents and Composite in Orthodontics
Effectiveness of One-Step Versus Two-Step Light Curing of Bonding Agent and Composite in Orthodontic Bracket Bonding: Study Design: A Randomized Controlled Trial (RCT) Study Type: Interventional Allocation: Randomized…
- Trial name
- 1STEP-2STEP-LC (NCT07491796)
- Testing
- One step light curing of bonding agent and composite, Two step light curing of bonding agent and composite
- Where
- Pakistan
- Volunteers
- 64 people, healthy volunteers welcome
- Sponsor
- Shaheed Zulfiqar Ali Bhutto Medical University