Clinical trials: Myocardial Perfusion
Coronary Artery Disease
A Phase I Study to Evaluate BFPET as a Potential Myocardial Perfusion Imaging(MPI) Agent for PET
Safety and dosimetry of BFPET™ will be evaluated in healthy volunteers and Coronary Artery Disease (CAD) patients , male or female and of age ranging between 20-80 years old.
- Trial name
- NCT00733460
- Testing
- BFPET
- Where
- United States
- Volunteers
- 12 people, healthy volunteers welcome
- Sponsor
- Fluoropharma, Inc.
Coronary Artery Disease
Perfusion Imaging and CT -Understanding Relative Efficacy
To determine the relative efficacy of Cardiac Computed Tomography Angiography (CCTA) and Single Positron Emission Computed Tomography (SPECT) in patients with an intermediate risk of CAD.
- Trial name
- PICTURE (NCT00486447)
- Testing
- 64 Channel VCT
- Where
- United States
- Volunteers
- 249 people
- Sponsor
- GE Healthcare
Myocardial Perfusion Imaging, Myocardial Ischemia
Effect of Ranolazine on Myocardial Perfusion Assessed by Serial Quantitative Exercise SPECT Imaging
This study enrolled participants with documented exercise-induced myocardial ischemia in order to evaluate whether ranolazine, when taken prior to exercise, can improve blood flow to the heart (myocardial perfusion), as assessed…
- Trial name
- NCT01221272
- Testing
- Ranolazine, SPECT MPI, Exercise
- Where
- 43 sites in United States, Canada and 6 more
- Volunteers
- 81 people
- Sponsor
- Gilead Sciences
Coronary Artery Disease (CAD)
Evaluation of XTR004 as a Novel 18F-labeled PET MPI Tracer in Diagnosis of Known or Suspected CAD
The diagnostic efficacy and safety of the XTR004 myocardial perfusion PET imaging tracer are evaluated for known or suspected CAD with the use of invasive coronary angiography as the reference standard for the diagnosis of CAD…
- Trial name
- NCT05885841
- Testing
- XTR004
- Where
- 2 sites in China
- Volunteers
- 83 people
- Sponsor
- Sinotau Pharmaceutical Group
Coronary Artery Disease
Gadobutrol/Gadavist-enhanced Cardiac Magnetic Resonance Imaging (CMRI) to Detect Coronary Artery Disease (CAD)
Participants being evaluated for suspected or known Coronary artery Disease (CAD) based on signs and/or symptoms, will be invited to participate in the study.
- Trial name
- GadaCAD 1 (NCT01890421)
- Testing
- Gadobutrol (Gadovist, Gadavist, BAY86-4875)
- Where
- 23 sites in United States, France and 5 more
- Volunteers
- 426 people
- Sponsor
- Bayer
Stable Angina, Non-ST-elevation Acute Coronary Syndrome
Japanese Coronary Intervention Using Drug Eluting and Perfusion Therapy for Left Main Disease (JDEPTH-LM Registry)
JDEPTH-LM Registry is a prospective, observational, multi-center study designed for the efficacy and safety of Double-effect kissing balloon technique (W-KBT) in left main (LM) bifurcation percutaneous coronary intervention (PCI)…
- Conditions
- Stable Angina, Non-ST-elevation Acute Coronary Syndrome, Unstable Angina
- Trial name
- NCT06436092
- Where
- 32 sites in Japan
- Volunteers
- 280 people
- Sponsor
- TCROSS Co., Ltd.
Coronary Artery Disease
Multislice Computed Tomography Assessment of PCSK9 Inhibition on Coronary Perfusion
The MARKOV study is an investigator-sponsored single arm, prospective study to assess the effect of evolocumab on the improvement in coronary flow (FFRCT) after 18 and 36 months of treatment in patients with coronary…
- Trial name
- MARKOV (NCT03851263)
- Testing
- Evolocumab
- Sponsor
- ECRI bv
Coronary Artery Disease
Familiarization and Safety Study of PB127 Ultrasound Contrast Agent
The purpose of this study is to evaluate preparation and administration of PB127, echocardiographic images obtained during PB127 administration, and evaluate the safety of PB127.
- Trial name
- NCT00594698
- Testing
- PB127 for injectable suspension
- Where
- 34 sites in United States
- Volunteers
- 150 people
- Sponsor
- Point Biomedical
Coronary Artery Disease (CAD)
A Study to Assess Regadenoson Administration Following an Inadequate Exercise Stress Test as Compared to Regadenoson Alone for Myocardial Perfusion Imaging (MPI) Using Single Photon Emission Computed Tomography (SPECT)
The purpose of this study is to demonstrate that the strength of agreement between single photon emission computed tomography (SPECT) imaging with regadenoson following inadequate exercise stress testing and SPECT imaging with…
- Trial name
- EXERRT (NCT01618669)
- Testing
- Regadenoson, Single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI)
- Where
- 69 sites in United States, Argentina and 2 more
- Volunteers
- 1,147 people
- Sponsor
- Astellas Pharma Global Development, Inc.
Coronary Artery Disease
Study of the Safety and Efficacy of Apadenoson for Detection of Myocardial Perfusion Defects Using SPECT MPI
The purpose of this study is to see whether apadenoson is as effective as adenosine when used as a pharmacological stress agent in myocardial SPECT-imaging (SPECT-MPI)to detect defects in the supply of blood to the heart muscle…
- Trial name
- ASPECT2 (NCT01313572)
- Testing
- Apadenoson SPECT-MPI, Adenosine SPECT-MPI
- Where
- 86 sites in United States, Argentina and 3 more
- Volunteers
- 197 people
- Sponsor
- Forest Laboratories
Coronary Artery Disease
Efficacy and Safety Study of Binodenoson in Assessing Cardiac Ischemia
Binodenoson (an experimental drug) and adenosine (an FDA-approved drug that is currently used by doctors) are used to increase blood flow to the heart just like when a person exercises on a treadmill.
- Trial name
- VISION-305 (NCT00944970)
- Testing
- binodenoson, adenosine
- Volunteers
- 578 people
- Sponsor
- Pfizer
Coronary Artery Disease
Rubidium-82 PET and Tc-99m-MIBI SPET: A Head to Head Comparison
The main purpose of this study is to compare myocardial perfusion imaging using Rubidium-82 PET with Tc-99m-MIBI SPET, in the evaluation of significant Coronary Artery Disease (CAD).
- Trial name
- NCT01379677
- Testing
- Rubidium-82, Sestamibi. reconstitution with sodium pertechnetate (99mTc)
- Where
- United Kingdom
- Volunteers
- 135 people
- Sponsor
- Advanced Accelerator Applications
Angina, Stable
Efficacy and Safety of Ad5FGF-4 for Myocardial Ischemia in Patients With Stable Angina Due to Coronary Artery Disease
The purpose of this study is to determine whether a single intracoronary infusion of Ad5FGF-4, delivered during induced transient ischemia, is effective in improving myocardial perfusion, angina functional class, patient…
- Trial name
- ASPIRE (NCT01550614)
- Testing
- Alferminogene tadenovec
- Where
- Russia
- Volunteers
- 11 people
- Sponsor
- Cardium Therapeutics
Coronary Artery Disease
ADVANCE MPI 1: Study of Regadenoson Versus Adenoscan® in Patients Undergoing Myocardial Perfusion Imaging (MPI)
Adenoscan® (adenosine) is an approved pharmacological stress agent indicated as an adjunct to thallium-201 myocardial perfusion scintigraphy in patients unable to exercise adequately.
- Trial name
- NCT00208299
- Testing
- Regadenoson, Adenosine
- Where
- United States
- Volunteers
- 1,231 people
- Sponsor
- Gilead Sciences
Coronary Artery Disease
CardioPET as PET Imaging Agent to Assess Myocardial Perfusion and Fatty Acid Uptake in Known or Suspected CAD Subjects
The study is designed to evaluate how safe and how well an investigational imaging product CardioPET™ performs as compared to standard approved imaging products in assessing the function of heart muscle in coronary artery disease…
- Trial name
- NCT01826773
- Testing
- CardioPET™
- Where
- 5 sites in Belgium
- Volunteers
- 34 people
- Sponsor
- Fluoropharma, Inc.
Coronary Artery Disease
RAdiolabeled Perfusion to Identify Coronary Artery Disease Using WAter To Evaluate Responses of Myocardial FLOW (RAPID-WATER-FLOW)
This a Phase 3, prospective, open-label, multicenter study of [15-O]-H2O injection for PET imaging of subjects with suspected CAD.
- Trial name
- NCT05134012
- Testing
- [O-15]-Water PET Myocardial Perfusion Imaging (MPI)
- Where
- 13 sites in United States, Canada and 4 more
- Volunteers
- 232 people
- Sponsor
- MedTrace Pharma A/S
Cardiogenic Shock, Acute Myocardial Infarction
Clinical Evaluation of NIRSense Tissue Oximetry Sensor Monitoring to Early Detect Cardiogenic Shock
This is a prospective, single-center, observational pilot study of the investigational NIRSense Tissue Oximetry Sensor System (Envello Core), a noninvasive wearable sensor patch that uses near-infrared spectroscopy (NIRS) and…
- Conditions
- Cardiogenic Shock, Acute Myocardial Infarction, Acute Decompensated Heart Failure
- Trial name
- NCT07825363
- Testing
- NIRSense Tissue Oximetry Sensor System
- Where
- United States
- Volunteers
- 20 people
- Sponsor
- NIRSense Inc.
Coronary Artery Disease
Registry for CARDIAC PERFUSION CT
This protocol describes a study whose goal is to collect de-identified Cardiac CT Perfusion (CTP) acquisition parameters and clinical findings from approximately 20 qualified medical facilities.
- Trial name
- RECRUIT (NCT01346605)
- Where
- United States
- Sponsor
- MDDX LLC
Diabetes Mellitus, Type 2
Lantus Effect on Myocardial Glucose Metabolism in T2
The primary objective of the present study is to assess changes of myocardial glucose uptake (MGU) during clamp studies using positron emission tomography (PET) scanning in patients with type 2 diabetes and idiopathic left…
- Trial name
- NCT00335465
- Testing
- Insulin glargine
- Where
- Italy
- Volunteers
- 15 people
- Sponsor
- Sanofi
Coronary Artery Disease (CAD), Myocardial Ischemia
A Study of XTR004 Radiotracer in Healthy Volunteers
XTR004 is a 18F-labeled myocardial perfusion positron emission tomography tracer use to measure myocardial perfusion and myocardial blood flow.
- Trial name
- NCT05195879
- Testing
- XTR004
- Where
- China
- Volunteers
- 10 people, healthy volunteers welcome
- Sponsor
- Sinotau Pharmaceutical Group