Clinical trials: Oxymetry
Oxygen Titration in Preterm Infants to Manage Lung Disease
IntellO2 vs Manual Control for Optimizing Oxygenation in Infants
The overall objective of this study is to demonstrate that the IntellO2 device providing automated control of fraction of inspired oxygen (FiO2) adjustments in spontaneously breathing infants with fluctuating arterial blood…
- Trial name
- NCT02074774
- Testing
- IntellO2, Manual control
- Where
- 2 sites in United Kingdom
- Volunteers
- 36 people
- Sponsor
- Vapotherm, Inc.
Healthy
Accuracy Evaluation of the Owlet OSS 3.0-M1 Sensor in Toddlers and Preschoolers
The purpose of the study is to collect information from the Owlet OSS 3.0-M1 Sensor in toddlers and preschoolers to evaluate accuracy.
- Trial name
- TOPS (NCT07321938)
- Testing
- Application and monitoring with an Owlet OSS 3.0-M1 Sensor, Reference Pulse Oximeter
- Where
- United States
- Volunteers
- 90 people, healthy volunteers welcome
- Sponsor
- Owlet Baby Care, Inc.
SpO2, Peripheral Oxygen Saturation Measurement
Wireless Disposable SpO2 Sensor Hypoxia Testing
The purpose of the study is to collect SpO2 data with simultaneous transfer standard SpO2 measurements data on human participants.
- Trial name
- SpO2 Dispo (NCT06211530)
- Testing
- SpO2 Sensor Testing
- Where
- United States
- Volunteers
- 32 people, healthy volunteers welcome
- Sponsor
- GE Healthcare
Healthy
Pulse Oximetry_Performance During Severe Signal Interference - PCBA-1 (Printed Circuit Board Assembly)
Determine accuracy specifications and labeling claims of a pulse oximeter in a diverse subject population during severe signal interference over a specified saturation range.
- Trial name
- NCT01747473
- Where
- United States
- Volunteers
- 17 people, healthy volunteers welcome
- Sponsor
- Medtronic - MITG
Hypoxia, Desaturation of Blood
SpO2 Accuracy Validation of the OxySoft Sensor Via Reference CO-Oximetry Motion Study
SpO2 (oxygen saturation) and pulse rate accuracy of pulse oximetry equipment, OxySoft Sensor/N-600x and OxySoft Sensor/N-395, continuous measure of arterial oxygen saturation during hypoxic state throughout motion and non-motion…
- Trial name
- NCT04559763
- Testing
- Non-Invasive Controlled Hypoxia, Introduction of Motion conditions: tapping or rubbing
- Where
- United States
- Volunteers
- 16 people, healthy volunteers welcome
- Sponsor
- Medtronic - MITG
Cardiogenic Shock, Acute Myocardial Infarction
Clinical Evaluation of NIRSense Tissue Oximetry Sensor Monitoring to Early Detect Cardiogenic Shock
This is a prospective, single-center, observational pilot study of the investigational NIRSense Tissue Oximetry Sensor System (Envello Core), a noninvasive wearable sensor patch that uses near-infrared spectroscopy (NIRS) and…
- Conditions
- Cardiogenic Shock, Acute Myocardial Infarction, Acute Decompensated Heart Failure
- Trial name
- NCT07825363
- Testing
- NIRSense Tissue Oximetry Sensor System
- Where
- United States
- Volunteers
- 20 people
- Sponsor
- NIRSense Inc.
Cerebral Oxygenation, Pediatric ALL
Accuracy Performance Verification of the INVOS™ System in Pediatrics
Prospective, observational, multi-center trial designed to capture calibration and performance evaluation data with the INVOS™ system.
- Trial name
- INCATH (NCT05962905)
- Testing
- Blood sample, INVOS monitoring
- Where
- 5 sites in United States
- Volunteers
- 110 people
- Sponsor
- Medtronic - MITG
Fetal Hypoxia
Trans-abdominal Fetal Pulse Oximetry; Tissue Light Scattering and Signal Integrity
The overall purpose of this study is to evaluate maternal-fetal tissue light scattering properties. The objectives of the study are: (i) integrate established mathematical principles of oxygen saturation to model with increasing…
- Trial name
- NCT04876846
- Testing
- GEN 3 Monitoring of Fetus
- Where
- United States
- Volunteers
- 9 people, healthy volunteers welcome
- Sponsor
- Raydiant Oximetry, Inc.
Pulse Oximetry
SpO2 Accuracy In Vivo Testing for Neonates & Infants
The purpose of this clinical study is to validate the oxygen saturation (SpO2) accuracy of various pulse oximetry systems and sensors (new designs and/or reprocessed) during non-motion conditions as compared to arterial blood…
- Trial name
- NCT03843489
- Testing
- MEDLINE RENEWAL PULSE OXIMETRY SENSORS, Reference CO-oximetry sensor
- Where
- United States
- Volunteers
- healthy volunteers welcome
- Sponsor
- Medline Industries
Pulse Oximetry
SpO2 System Accuracy Testing With Different Sensors
A study to test the accuracy of SpO2 sensors with various patient monitors, co-oximeters, and modules.
- Trial name
- NCT01613222
- Testing
- Pulse oximetry
- Where
- United States
- Volunteers
- 63 people, healthy volunteers welcome
- Sponsor
- GE Healthcare
Obstructive Sleep Apnea (OSA)
INFORMing Patients With Oximetry Data to Improve MAD Engagement
Obstructive sleep apnea (OSA) is common and associated with impaired daytime functioning, reduced quality of life and increased cardiovascular, metabolic and perioperative risk.
- Trial name
- INFORM (NCT07564310)
- Testing
- Narval MRD device, MyNarval intervention (Narval CC MAD + O2 ring + MyNarval smartphone application),
- Volunteers
- 120 people
- Sponsor
- ResMed
Obstructive Sleep Apnea
Oxygen Saturation Patterns in Post-Op Patients at Risk for Obstructive Sleep Apnea
This study will include patients who have major surgery and are at risk for or have been diagnosed with sleep apnea. The patients will be monitored the night after surgery for repeating episodes of reduced breathing and oxygen…
- Trial name
- NCT01078207
- Where
- 2 sites in Canada
- Volunteers
- 100 people
- Sponsor
- Medtronic - MITG
Skin Types, Pulse Oximetry
Skin Tone Measurement Method Investigation for Pulse Oximetry
The primary objective is to gather missing information in order to form a well-founded recommendation on which is the preferred skin pigmentation measurement (PPM) methods in the context of pulse-oximetry.
- Trial name
- NCT05657665
- Testing
- Observational measurements of skin tone
- Where
- Netherlands
- Volunteers
- 12 people
- Sponsor
- Philips Clinical & Medical Affairs Global
Post Surgical Respiratory Failure, Respiratory Complication
Advanced Prediction of Respiratory Depression Episode With the Linshom Continuous Predictive Respiratory Sensor
Investigators will enroll 320 patients who will undergo non-cardiac surgery, receive supplemental oxygen via face mask, and will be on a continuous pulse oximetry monitor in the Post Anesthesia Care Unit (PACU).
- Trial name
- NCT05804175
- Testing
- Linshom Continuous Predictive Respiratory Monitoring
- Where
- 2 sites in United States
- Volunteers
- 600 people
- Sponsor
- Linshom Medical, Inc.
Fetal Hypoxia, Fetal Distress
Trans-abdominal Fetal Pulse Oximetry
The Raydiant Oximetry Sensing System (Lumerah) is a non-invasive fetal pulse oximeter that measures fetal arterial oxygen saturation using safe, non-invasive, transabdominal near-infrared spectroscopy.
- Conditions
- Fetal Hypoxia, Fetal Distress, Fetal Acidemia, Fetal or Neonatal Effect of Complication of Labor
- Trial name
- NCT05147584
- Testing
- Dual fetal oxygen sensors
- Where
- United States
- Volunteers
- 31 people, healthy volunteers welcome
- Sponsor
- Raydiant Oximetry, Inc.
Hypoxia, Hemodilution
Hypoxia and Hemodilution Testing in Healthy Adult Volunteers
This study will collect physiological measurements in healthy adult volunteers under controlled hypoxia and hemodilution conditions.
- Trial name
- NCT07503171
- Testing
- Noninvasive Physiological Monitoring Device
- Where
- United States
- Volunteers
- 7 people, healthy volunteers welcome
- Sponsor
- Nihon Kohden
Pulse Oximetry
SpO2 Verification Study - Philips Nasal Alar With Nellcor OxiMax SpO2 Board (453564624031)
The primary purpose of the clinical investigation is to verify the SpO2 accuracy of the Philips AlarX5 SpO2 sensor with Nellcor OxiMax SpO2 Board.
- Trial name
- NCT07680530
- Testing
- Evaluation of Oxygen Sensors
- Where
- United States
- Volunteers
- 43 people, healthy volunteers welcome
- Sponsor
- Philips Clinical & Medical Affairs Global
Pulse Oximetry
PULSE OXIMETRY Performance Test for a Software Medical Device 'Vitacam'
This clinical investigation aims to collect data for algorithm development and testing of Vitacam as well as to later validate the system using a simultaneously collected, but segregated, hold-out validation dataset.
- Trial name
- NCT06912516
- Testing
- Controlled desaturation
- Where
- Finland
- Volunteers
- 24 people, healthy volunteers welcome
- Sponsor
- Evondos Oy
Surgery
Calibration and Validation of Masimo's O3 Regional Oximetry Device in Neonates, Infants and Children
The study will collect cerebral oximetry data from pediatric and neonatal subjects using the Masimo O3 regional oximetry device, for the purposes of device calibration and validation.
- Trial name
- NCT03123354
- Testing
- O3 regional oximeter sensor
- Where
- United States
- Volunteers
- 44 people
- Sponsor
- Masimo Corporation
Pulse Oximetry
SpO2 Validation Study - Philips FAST 2024
Validation study to compare the accuracy of non-invasive Philips SpO2 sensors in detecting blood oxygen levels compared to invasive methods requiring a blood draw and lab analysis.
- Trial name
- FAST 2024 (NCT06484452)
- Testing
- No Intervention
- Where
- United States
- Volunteers
- 113 people, healthy volunteers welcome
- Sponsor
- Philips Clinical & Medical Affairs Global