Clinical trials: Radial Artery Hemostasis
Arterial Occlusion, Angina Pectoris
Comparing TR Band to Statseal in Conjunction With TR Band
The primary objectives of this study are to evaluate the performance of StatSeal Advanced used in conjunction with the TR Band (SSA) as compared to the TR Band without SSA (TRB) relative to: the incidence of peri-procedural…
- Conditions
- Arterial Occlusion, Angina Pectoris, Cardiovascular Diseases, Atherosclerosis
- Trial name
- NCT03028025
- Testing
- StatSeal, TR Band
- Where
- United States
- Volunteers
- 184 people
- Sponsor
- VA Long Beach Healthcare System
Radial Artery Hemostasis
Radial Artery Puncture Hemostasis Study
RAPHE is an open label randomized clinical trial to assess physical, biological and chemical methods of radial artery puncture hemostasis following coronary catheterization.
- Trial name
- RAPHE (NCT04857385)
- Testing
- Radial artery hemostasis
- Where
- 3 sites in Hungary
- Volunteers
- 600 people
- Sponsor
- Semmelweis University Heart and Vascular Center
Injury; Blood Vessel, Wrist, Radial Artery
Assessment of Radial Artery Complications Whilst Achieving Rapid Haemostasis
The purpose of this study is to compare different protocols aimed at achieving haemostasis (i.e. stop the bleeding) in patients undergoing heart procedures with access through the wrist.
- Trial name
- ARCH (NCT04457219)
- Testing
- Haemostatic Dressing, Conventional Dressing, 120 Minutes External Compression
- Where
- United Kingdom
- Volunteers
- 2,114 people
- Sponsor
- Liverpool Heart and Chest Hospital NHS Foundation Trust
Radial Artery Injury, Hematoma
Ankaferd Blood Stopper for Hemostasis After Transradial Coronary Angiography
In 2008 Goker et al, introduced Ankaferd Blood Stopper (ABS) as a new hemostatic drug. Recently, ABS has been shown to produce local hemostasis by implementing topically after major arterial vessel injury.
- Conditions
- Radial Artery Injury, Hematoma, Bleed
- Trial name
- NCT02982733
- Testing
- ABS, TR Band, CS
- Where
- Turkey (Türkiye)
- Volunteers
- 600 people
- Sponsor
- Acibadem University
Coronary Artery Disease, Myocardial Infarction
Compressive Elastic Dressing Versus TR Band
Radial approach is widely established in cardiac diagnostic and therapeutic treatments. It has been shown to decrease bleeding, vascular problems, and mortality rates when compared to the femoral approach.
- Conditions
- Coronary Artery Disease, Myocardial Infarction, Angina, Unstable, Angina, Stable
- Trial name
- Band Vs Gauze (NCT05409716)
- Testing
- Compressive Elastic dressing for hemostasis in cardiac procedure using radial approach, Wristband TR band for hemostasis in cardiac procedure using radial approach
- Where
- 2 sites in Palestinian Territories
- Volunteers
- 400 people
- Sponsor
- An-Najah National University
Angiogram, Percutaneous Coronary Intervention
RAVE: Radial Artery Vascular Complication and Resource Utilization
The primary objective of this study is to determine if there is a reduction in time to hemostasis in subjects treated with SoftSeal®-STF hemostatic pad when used in conjunction with a vascular compression device after radial…
- Trial name
- NCT03522077
- Testing
- RadAR EasyCLik plus ®-STF hemostatic pad, TR BAND® Compression device plus ®-STF hemostatic pad, SoftSeal®-STF hemostatic pad
- Where
- United States
- Volunteers
- 300 people
- Sponsor
- Wake Forest University Health Sciences
Radial Artery Injury
Dual Artery Compression vs. Radial Artery-Only Hemostasis: Impact on Radial Artery Occlusion (EASY-RAO)
This study aims to demonstrate the superiority in clinical performances of a dual artery compression device (Terry-2 band) compared to a standard radial artery-only hemostasis device (HemoSTOP).
- Trial name
- EASY-RAO (NCT04439513)
- Testing
- Hemostasis
- Where
- Canada
- Volunteers
- 100 people
- Sponsor
- Olivier F. Bertrand
Hemostasis of Arterial Punctures
Flow Dynamics During Simulated Hemostasis at the Proximal and Distal Radial Arteries
Transradial access (TRA) has been widely adopted for coronary angiography and percutaneous coronary intervention, as it has been shown to significantly reduce bleeding complications, vascular complications, and mortality compared…
- Trial name
- FLOW-PRADA (NCT07686003)
- Testing
- Air-filled hemostatic band
- Where
- South Korea
- Volunteers
- 220 people, healthy volunteers welcome
- Sponsor
- Wonju Severance Christian Hospital
Injury of Radial Artery
Nitroglycerin Prevents Radial Artery Occlusion
Trans-radial approach (TRA) has becoming popular and widely adopted over the last decade. However, radial artery occlusion (RAO) continues to be one of the limitation of trans-radial access and potentially limits the radial…
- Trial name
- NORAO (NCT02105493)
- Testing
- 500 microgram of Nitroglycerin, Saline 5 mL
- Where
- Indonesia
- Volunteers
- 1,706 people
- Sponsor
- National Cardiovascular Center Harapan Kita Hospital Indonesia
Coronary Intervention, Transradial Approach
Efficacy and Safety of Hemostatic Methods in Distal Radial Artery Approach for Cardiac Catheterization
Comparison of PreludeSYNC distal and Modified Terumo Radial Band in patients with distal radial approach.
- Trial name
- HEMOSTAD-INC (NCT05966376)
- Testing
- Hemostatic device for distal radial approach.
- Where
- Mexico
- Volunteers
- 482 people
- Sponsor
- Instituto Nacional de Cardiologia Ignacio Chavez
Coronary Catheterization
Comparing Advanced Hemostasis and Ultrasound-Guided Puncture to Conventional Approaches in Distal Radial Access
Meta-analysis results show that distal radial access (DRA) is associated with a significant reduction in the risk of radial artery occlusion compared to conventional transradial access (TRA).
- Trial name
- ALPHA&OMEGA (NCT06835829)
- Testing
- Transradial potassium ferrate hemostatic patch, Distal radial potassium ferrate hemostatic patch, Ultrasound-guidance
- Where
- 6 sites in Belgium, Italy
- Volunteers
- 480 people
- Sponsor
- Associazione per lo Studio delle Malattie Cardiovascolari Cardiva ONLUS
Coronary Artery Disease
Hemostasis With QuikClot® Radial® Pad Versus TR Band® After Transradial Artery Access
To evaluate the efficacy and safety of the QuikClot® Radial® pad on hemostasis after transradial access (TRA), compared to the standard of care TR Band®, to hopefully develop a safe and efficacious technique to achieve more rapid…
- Trial name
- NCT03535597
- Testing
- Quikclot Radial (QC) Pad
- Where
- United States
- Volunteers
- 355 people
- Sponsor
- Memorial Healthcare System
Cardiovascular Diseases, Bleeding
Safe and Fast Radial Hemostasis Using Synergistic Strategies: SAFE & FAST Trial
The Safe and Fast Radial Hemostasis using Synergistic Strategies (SAFE \& FAST) trial is an interventional study aimed at reducing the incidence of radial artery occlusion (RAO) rebound bleeding, and the required compression…
- Conditions
- Cardiovascular Diseases, Bleeding, Arterial Puncture, Catheter Complications
- Trial name
- NCT06549842
- Testing
- Heparin, Terumo Radial Band, Vaosband
- Where
- 2 sites in United States, India
- Volunteers
- 451 people
- Sponsor
- Regional Hospital of Scranton
Radial Artery Injury at Wrist and Hand Level
Patent Hemostasis With Vasoband Versus TR Band
In patients referred for cardiac catheterization to be performed using transradial access, a randomized comparison will be performed with the primary endpoint of patency of radial artery at the time of application of hemostatic…
- Trial name
- OPEN-Radial (NCT04002791)
- Testing
- VasoBand
- Where
- India
- Volunteers
- 253 people
- Sponsor
- Total Cardiovascular Solutions
Radial Artery Occlusion, Cardiac Catheterization
Manual vs Pneumatic Compression to Prevent Radial Artery Occlusion After Transradial Procedures
This study evaluates two commonly used methods of achieving hemostasis after transradial cardiac catheterization: manual compression and pneumatic compression with gradual deflation.
- Trial name
- RADIAL-HEMO (NCT07621185)
- Testing
- Manual Radial Compression, Pneumatic Radial Compression Device
- Where
- Spain
- Volunteers
- 1,168 people
- Sponsor
- Hospital Clinic of Barcelona
Radial Artery Occlusion, Hematoma
Combination of InnoSEAL Plus TR Band Compared to TR Band Alone
Angiography or angioplasty are commonly now done through inserting the device through radial artery in hand i.e. trans-radial procedures.
- Trial name
- NCT04380883
- Testing
- InnoSEAL+TRB, TRB alone
- Where
- Pakistan
- Volunteers
- 714 people
- Sponsor
- Tabba Heart Institute
Percutaneous Coronary Intervention, Angiography
Studying Hemostatic Effect of Axiostat® Dressing on Radial Access After Percutaneous Procedure
To evaluate Safety and Efficacy of Axiostat® hemostatic dressing in terms of time to achieve hemostasis, post application complication and comfort levels of patients.
- Conditions
- Percutaneous Coronary Intervention, Angiography, Angioplasty
- Trial name
- AHD (NCT02837744)
- Testing
- Axiostat®
- Where
- India
- Volunteers
- 70 people, healthy volunteers welcome
- Sponsor
- Axio Biosolutions Pvt. Ltd.
Radial Artery Occlusion
Low Dose Heparin Factorial Trial
An open label 2x2 factorial randomized trial is planned to determine the difference in mean hemostasis time between low dose heparin (LD) i.e between 2000-3000 IU and standard dose heparin (SD) i.e.
- Trial name
- NCT05591872
- Testing
- LD+I+TRB
- Where
- Pakistan
- Volunteers
- 800 people
- Sponsor
- Tabba Heart Institute
Radial Artery Occlusion
Radial Artery Occlusion and Dual Artery Hemostasis After Transradial Approach.
Improving patient comfort and implementing the protocols required to minimize the risk of RAO must be part of quality control. Several procedural parameters are related to the risk of RAO but hemostasis is a critical period.
- Trial name
- NCT04933136
- Testing
- Terry2 Band
- Where
- 5 sites in Canada
- Volunteers
- 500 people
- Sponsor
- Laval University
Radial Artery
Oximetry Guided Versus Traditional Rapid Deflation Technique for Achieving Hemostasis After Radial Procedures
After performing a radial angiography/percutaneous coronary intervention (CAG/PCI), the sheath is removed and a compression device is used to achieve hemostasis.
- Trial name
- ACCESS-III (NCT03626129)
- Testing
- Oximetry guided deflation
- Where
- Denmark
- Volunteers
- 3,600 people, healthy volunteers welcome
- Sponsor
- Aarhus University Hospital Skejby