Clinical trials: Stent Obstruction
Renal Artery Obstruction, Hypertension, Renal
The HERCULES Trial - A Safety and Effectiveness Study of the Herculink Elite Renal Stent to Treat Renal Artery Stenosis
The purpose of this study is to determine whether the Herculink Elite Renal Stent System is safe and effective in the treatment of renal artery stenosis in patients with less than optimal angioplasty results and uncontrolled…
- Trial name
- HERCULES (NCT00490841)
- Testing
- Herculink Elite Renal Stent System
- Where
- United States
- Volunteers
- 202 people
- Sponsor
- Abbott Medical Devices
Pancreatic Cancer
Plastic vs. Covered Metal vs. Uncovered Metal Biliary Stents for the Management of Malignant Biliary Obstruction
This is a single center, randomized, unblinded study to compare the rate of occlusion of plastic, uncovered metal, or fully covered metal biliary stents in patient's with surgically resectable disease or those undergoing…
- Trial name
- NCT01038713
- Testing
- Biliary stent placement
- Where
- United States
- Volunteers
- 94 people
- Sponsor
- Dartmouth-Hitchcock Medical Center
Ureteral Obstruction
Treatment of Symptoms After Stent Placement for Urinary Tract Obstruction
The purpose of this study is to determine whether combination therapy with Tolterodine ER and Tamsulosin is more effective than monotherapy with tamsulosin alone in reducing stent symptoms.
- Trial name
- NCT01741454
- Testing
- Tamsulosin, Tolterodine ER
- Where
- United States
- Volunteers
- 181 people
- Sponsor
- University of Wisconsin, Madison
Coronary Artery Stenosis, Coronary Arteriosclerosis
XIENCE V: SPIRIT WOMEN Sub-study
The purpose of this Clinical Evaluation is the continued assessment of the XIENCE Everolimus Eluting Coronary Stent System (XIENCE V® and XIENCE PRIME™ EECSS) with the primary focus on clinical outcomes in the treatment of female…
- Conditions
- Coronary Artery Stenosis, Coronary Arteriosclerosis, Coronary Artery Disease, Coronary Artery Restenosis
- Trial name
- NCT01182428
- Testing
- XIENCE V®/ XIENCE PRIME™, CYPHER SELECT
- Where
- 25 sites in Argentina, Austria and 13 more
- Volunteers
- 455 people
- Sponsor
- Abbott Medical Devices
Angina, Chronic Coronary Occlusion
XIENCE V/PROMUS Everolimus-Eluting Stent System Post-marketing Surveillance Protocol for Japan
The objectives of this post-marketing surveillance, conducted in Japan, is to know the frequency, type and degree of device malfunction, to assure the safety of the medical device, and to collect information on evaluation of the…
- Conditions
- Angina, Chronic Coronary Occlusion, Stent Thrombosis, Vascular Disease
- Trial name
- NCT01086228
- Testing
- XIENCE V / PROMUS stent
- Where
- 47 sites in Japan
- Volunteers
- 2,010 people
- Sponsor
- Abbott Medical Devices
Biliary Strictures Caused by Malignant Neoplasms
Study of the WallFlex™ Biliary Partially-covered Stent for the Palliative Treatment of Malignant Bile Duct Obstruction
This is a a prospective study of the WallFlex™ Biliary Partially-covered Stent designed to collect data to support regulatory clearance by the FDA in the United States and to determine the functionality of the WallFlex™ Biliary…
- Trial name
- NCT00713427
- Testing
- WallFlex™ Biliary Partially-Covered Stent
- Where
- 6 sites in Belgium, France and 4 more
- Volunteers
- 70 people
- Sponsor
- Boston Scientific Corporation
Angina, Coronary Occlusion
XIENCE PRIME Japan Post-Marketing Surveillance (PMS)
The objectives of the PMS are to observe the frequency, type, and degree of device deficiency to assure the safety of the new medical device (XIENCE PRIME) as well as to collect information on evaluation of the efficacy and…
- Conditions
- Angina, Coronary Occlusion, Coronary Artery Disease, Coronary Artery Stenosis
- Trial name
- NCT01721096
- Testing
- XIENCE PRIME - Long Length (LL), XIENCE PRIME - Core Size
- Where
- Japan
- Volunteers
- 536 people
- Sponsor
- Abbott Medical Devices
Cholestasis, Extrahepatic
A Study of the WallFlex™ Biliary Fully-covered Stent for the Palliative Treatment of Malignant Bile Duct Obstruction
The overall objective of this study is to assess the functionality of the WallFlex™ Biliary Fully-covered stent as a palliative treatment for malignant bile duct obstruction.
- Trial name
- NCT00433771
- Testing
- WallFlex™ Biliary Fully Covered Metal Stent placement
- Where
- 10 sites in United States
- Volunteers
- 74 people
- Sponsor
- Boston Scientific Corporation
Femoral Artery Stenosis, Femoral Artery Occlusion
Lutonix® Drug Coated Balloon vs. Standard Balloon Angioplasty for Treatment of Femoropopliteal In-Stent Restenosis
To assess the safety and efficacy of the Lutonix Drug Coated Balloon for treatment of femoropopliteal artery (SFA) in-stent restenosis (ISR).
- Conditions
- Femoral Artery Stenosis, Femoral Artery Occlusion, Restenosis
- Trial name
- SFA ISR (NCT02063672)
- Testing
- Lutonix DCB, Standard Uncoated Balloon Angioplasty Catheter
- Where
- 20 sites in United States
- Volunteers
- 82 people
- Sponsor
- C. R. Bard
Coronary Artery Disease
SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V® Everolimus Eluting Coronary Stent System
The purpose of the SPIRIT IV Clinical Trial is to continue to evaluate the safety and efficacy of the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V®).
- Trial name
- NCT00307047
- Testing
- XIENCE V® Everolimus Eluting Coronary Stent, TAXUS™ EXPRESS2™ Paclitaxel Eluting Coronary Stent
- Where
- 65 sites in United States
- Volunteers
- 3,687 people
- Sponsor
- Abbott Medical Devices
Venous Stenosis, Venous Occlusion
The Merit WRAPSODY AV Access Efficacy Study (WAVE)
The purpose of the study is to demonstrate the safety and efficacy of the Merit WRAPSODY Endovascular Stent Graft for treatment of stenosis or occlusion within the dialysis access outflow circuit
- Trial name
- WAVE (NCT04540302)
- Testing
- Merit WRAPSODY Endovascular Stent Graft, PTA
- Where
- 43 sites in United States, Brazil and 2 more
- Volunteers
- 357 people
- Sponsor
- Merit Medical Systems, Inc.
Coronary Artery Disease
XIENCE V® Everolimus Eluting Coronary Stent System USA Post-Approval Study (XIENCE V® USA-Phase 1)
XIENCE V USA is a prospective, multi-center, multi-cohort post-approval study. The objectives of this study are To evaluate XIENCE V EECSS continued safety and effectiveness during commercial use in real world settings, and To…
- Trial name
- XVU-Phase 1 (NCT00676520)
- Testing
- XIENCE V® Everolimus Eluting Coronary Stent
- Where
- United States
- Volunteers
- 8,053 people
- Sponsor
- Abbott Medical Devices
Pancreatic Cancer, Unresectable Biliary-pancreatic Malignancies
Endoscopic Biliary Co-axial Stent Placement Plus/Minus Use of Radiofrequency Ablation (RFA) for Clearance of Occluded Self Expandable Metal Stents (SEMS) in Patients With Distal Biliary Obstruction From Unresectable Biliary-pancreatic Malignancies
The purpose of this study is to compare the effects good and/or bad of combining radiofrequency ablation with placement of a second stent, versus a second stent alone.
- Trial name
- NCT02340728
- Testing
- ERCP with SEMS plus radiofrequency ablation, ERCP with SEMS alone (standard of care)
- Where
- United States
- Volunteers
- 24 people
- Sponsor
- Memorial Sloan Kettering Cancer Center
Renal Artery Stenosis, Hypertension, Renovascular
Renal Stent Placement for the Treatment of Renal Artery Stenosis in Patients With Resistant Hypertension
The purpose of this trial is to test how well the iCAST™ RX Stent works in patients diagnosed with atherosclerotic renal artery stenosis and whether or not increased blood flow by the stent will help to control blood pressure.
- Trial name
- ARTISAN (NCT01673373)
- Testing
- iCAST™ Rx Stent System
- Where
- 12 sites in United States
- Volunteers
- 68 people
- Sponsor
- Atrium Medical Corporation
Gastric Outlet Obstruction
Magnetic Anastomosis Device Relief of Malignant Gastric Outlet Obstruction
The purpose of this study is to determine if the Cook Magnetic Anastomosis Device can be used to safely and successfully create a patent gastrojejunal anastomosis in subjects requiring treatment of gastric outlet obstruction…
- Trial name
- MAD (NCT00487552)
- Testing
- Cook Magnetic Anastomosis Device (MAD) with Stent
- Where
- 4 sites in Belgium, Italy and 1 more
- Volunteers
- 18 people
- Sponsor
- Cook Group Incorporated
Peripheral Arterial Disease
Multi-center Study for Stent Graft System for Peripheral Artery
The utility of GP1101 will be evaluated relative to that of surgical bypass in the treatment of Femoral/Popliteal Arterial Symptomatic Peripheral Arterial Disease.
- Trial name
- VJH11-01 (NCT01575808)
- Testing
- GP1101
- Where
- 15 sites in Japan
- Volunteers
- 133 people
- Sponsor
- W.L.Gore & Associates
Gastric Outlet Obstruction
Gastric Outlet Obstructions Tailored Covered Stents for GOO
gastric outlet obstruction tailored versus standard stents for malignant gastric outlet obstruction treatments
- Trial name
- NCT02299258
- Testing
- Standard stents MTN-CG-s-20/100, Tailored stents MTN-WE-20/100-A
- Where
- China
- Volunteers
- 63 people
- Sponsor
- The First People's Hospital of Yuhang District
Stents, Coronary Artery Disease
SPIRIT III Clinical Trial of the XIENCE V® Everolimus Eluting Coronary Stent System (EECSS)
This study is divided into 5 arms: 1. Randomized Clinical Trial (RCT): Prospective, randomized, active-controlled, single blind, parallel two-arm multi-center clinical trial in the United States (US) comparing XIENCE V®…
- Conditions
- Stents, Coronary Artery Disease, Total Coronary Occlusion, Coronary Artery Restenosis
- Trial name
- NCT00180479
- Testing
- XIENCE V® Everolimus Eluting Coronary Stent, TAXUS® EXPRESS2™ Paclitaxel Eluting Coronary Stent
- Where
- 65 sites in United States
- Volunteers
- 1,002 people
- Sponsor
- Abbott Medical Devices
Distal Bile Duct Obstruction
Covered vs Uncovered Metal Stents for Palliative Biliary Decompression in Inoperable Malignant Distal Bile Duct Obstruction
The purpose of this study is to compare the rate of long-term stent failure, defined as need for repeat biliary intervention following placement of C-SEMS vs U-SEMS for palliation of inoperable malignant distal bile duct…
- Trial name
- NCT01905384
- Testing
- Covered Self-expanding metal biliary stents (C-SEMS), Uncovered Self-expanding metal biliary stents (U-SEMS)
- Where
- 2 sites in United States
- Volunteers
- 6 people
- Sponsor
- Vanderbilt University Medical Center
Vascular Stent-Graft Stenosis
GORE® VIABAHN® Endoprosthesis Post-Marketing Surveillance Study
This study will confirm the efficacy and safety in the clinical setting after the launch of the GORE® VIABAHN® stent graft (hereafter referred to as "Viabahn") for the treatment of patients with stenosis or occlusion at the…
- Trial name
- NCT04429243
- Testing
- GORE® VIABAHN® Stent Graft
- Where
- 17 sites in Japan
- Volunteers
- 124 people
- Sponsor
- W.L.Gore & Associates