AzTrials
AzTrials

Fluid ResponsivenessPPI-FRNCT06313671

Plethysmographic Perfusion Index and Fluid Responsiveness

An observational study of Fluid Responsiveness, run by Avicenna Military Hospital at 1 site in Morocco.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The objective of this study is to assess the reliability of the perfusion index to predict fluid responsiveness in patients with acute circulatory failure in intensive care. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Fluid Responsiveness
What is being tested?
Perfusion index
How many people
50 participants
Where
1 siteMorocco
Study dates
10 Feb 2024to 10 Sep 2024
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients aged 18 and older with acute circulatory failure (ACF). ACF is defined by the presence of signs of tissue hypoperfusion: capillary refill time>5 seconds, mottling, oliguria <0.5 mL/kg/h for more than an hour), altered mental status), blood lactate >2 mmol/L or metabolic acidosis (pH <7.35 or base excess >-5). Arterial hypotension is not necessary for the diagnosis of ACF. It is defined by a systolic blood pressure (SBP) <90 mmHg, a mean arterial pressure (MAP) <65 mmHg, or a drop in SBP ≥40 mmHg. Shock is defined by the combination of ACF and arterial hypotension.

Who may be able to join

  • Patients aged 18 and older with acute circulatory failure (ACF).

Who cannot join

  • Low echogenicity: the inability to perform echocardiographic measurements according to established recommendations.
  • Absence of the plethysmographic signal.

Trial locations and contacts

1 site in 1 country.

Morocco1 site
  • Avicenna Military Hospital

    Marrakesh, Marrakesh Tensift El Haouz, 40000

Other trials in Morocco

About this study

Official title: Reliability of Plethysmographic Perfusion Index to Predict Fluid Responsiveness in Acute Circulatory Failure.

The objective of this study is to assess the reliability of the perfusion index to predict fluid responsiveness in patients with acute circulatory failure in intensive care.

Read the detailed description

In patients with acute circulatory failure, it is recommended to assess fluid responsiveness. Fluid responsiveness is defined by an increase in cardiac output of 10 to 15% after fluid loading. The assessment of fluid responsiveness usually needs cardiac output monitoring (or stroke volume). However, in limited resource settings or during the initial management of patients with acute circulatory failure, cardiac output measurement is usually unavailable. The perfusion index (PI) is derived from the plethysmographic signal of the pulse oximeter and represents the ratio between the ratio of pulsatile on non-pulsatile light absorbance of the plethysmography signal. The PI is influenced by vascular and stroke volume. The investigators hypothesized that the peripheral index could track the changes in cardiac output induced by fluid loading and therefore detect fluid responsiveness.

Adult patients with acute circulatory failure in whom physicians want to test the fluid responsiveness will be included. At baseline, the PI will be recorded. An initial echocardiography will be performed to measure the left ventricular outflow tract velocity time integral (a surrogate of stroke volume). A fluid loading with 500 ml of 0.9% Saline or Ringer Lactate will be performed. After fluid administration, the velocity time integral and the PI will be collected. Fluid-responsive patients are defined by a 15% increase in velocity time integral. The investigators will analyze the ability of the PI to detect fluid responsiveness.

Being tested
Perfusion index
Keywords
acute circulatory failure, fluid responsiveness, perfusion index, left ventricular outflow velocity time-integral, echocardiography
Medical subject headings
Shock

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Perfusion indexDiagnostic test

    The perfusion index (PI) is derived from the plethysmography signal and represents the ratio of pulsatile to non-pulsatile light absorbance of the plethysmography signal.

    PPG signal.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Reliability and accuracy of the perfusion index to discriminate fluid-responsiveness.

    Reliability and accuracy of the change in perfusion index to discriminate fluid-responsive patients. Fluid responsiveness is defined by an increase in the left ventricular outflow tract velocity time integral by 15% after fluid loading.

    Measured: through study completion, an average of 9 months.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Mar 2024
  2. Study start10 Feb 2024
  3. Primary completion10 Sep 2024
  4. Study completion10 Sep 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06313671
Sponsor's protocol ID
Perfusion Index - FR study
Acronym
PPI-FR
Status last verified
Mar 2025
First submitted
7 Jan 2024
Last updated
11 Mar 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: The data that support the findings of this study will be available from the principal investigator upon reasonable request.

Publications

  • Aissaoui Y, Belhadj A, Eddakya W, Bencharfa B, Bouchama A, Didi M, Elbaraka H, Fassiki N, Myatt I, Qamouss Y, Leone M, Abouqal R. Early hemodynamic phenotyping in sepsis using transthoracic echocardiography: A proof-of-concept study in a north African ICU. J Crit Care. 2026 Aug;94:155504. doi: 10.1016/j.jcrc.2026.155504. Epub 2026 Feb 26.

    PubMed 41759300
  • Aissaoui Y, Bouchama A, Abouelkemhe C, Enourhbi A, Bencharfa B, Didi M, Aguena H, Belhadj A. The reliability of the plethysmographic perfusion index for detecting fluid responsiveness in critically ill patients. J Intensive Med. 2025 Sep 27;6(1):34-41. doi: 10.1016/j.jointm.2025.07.004. eCollection 2026 Feb.

    PubMed 41736778

Questions about this trial

What is this clinical trial studying?

An observational study of Fluid Responsiveness, run by Avicenna Military Hospital at 1 site in Morocco.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Mar 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Morocco. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Reliability and accuracy of the perfusion index to discriminate fluid-responsiveness. (time frame: through study completion, an average of 9 months.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06313671, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Mar 2025; AzTrials last refreshed its copy on 30 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in