Clinical trials: Plate Fixation
Mandibular Angle Fracture
Patient Specific 3d Titanium Plate Versus Standard Two Mini Plates in the Fixation of Mandibular Angle Fractures (a Randomized Controlled Clinical Trial)
To compare the effectiveness of custom-made (3D) titanium plates to standard two titanium mini plates in fixation of mandibular angle fracture.
- Trial name
- NCT07390734
- Testing
- custom-made 3D titanium plates, standared two mini plates
- Where
- Egypt
- Volunteers
- 16 people
- Sponsor
- Alexandria University
Distal Femur Fractures
Single vs. Dual Implant Fixation for Distal Femur Fractures in Older or Compromised Adults
The goal of this clinical trial is to assess the feasibility of conducting a larger study comparing single implant fixation (SIF) and dual implant fixation (DIF) for treating distal femur fractures (DFF) in older or compromised…
- Trial name
- NCT06944964
- Testing
- Single Implant Fixation (SIF), Dual Implant Fixation (DIF)
- Where
- 2 sites in Canada
- Volunteers
- 44 people
- Sponsor
- London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
Mandibular Hypoplasia
Comparing Stability and Cost-Effectiveness of 3 Bicortical Screws Vs Adjustable Plate and 2 Bicortical Screws in Fixation of BSSRO
In this current study a comparison between 3 positional screws versus the adjustable plating system in conjunction with 2 positional screws. The patients will be selected to have retrognathic mandible requiring advancement.
- Trial name
- NCT02950727
- Testing
- 3 bicortical screws, adjustable plate and 2 bicortical screws
- Volunteers
- 12 people, healthy volunteers welcome
- Sponsor
- Joseph Van Sickels
Femoral Fractures
Plate Fixation of Distal Femur Fractures: A Protocol for a Study of Two Plate Options
Internal fixation of femur fractures improves alignment and provides stability to the bone and the surrounding soft tissues. This generally allows for early motion of the adjacent joints; thus maximizing overall function of the…
- Trial name
- NCT00644397
- Testing
- 95-degree Angled Blade Plate, 4.5mm Condylar Locking Plate
- Where
- United States
- Volunteers
- 80 people
- Sponsor
- MetroHealth Medical Center
Cervical Spine Fractures
MALMOS Technique for Selected Subaxial Cervical Spine Fractures
This prospective study will evaluate the clinical and radiological outcomes of the MALMOS technique with neutralization H-plate fixation in patients with selected subaxial cervical spine fractures.
- Trial name
- MALMOS (NCT07905573)
- Testing
- Meshtawy's Anterior Ligamentotaxis and Miniplate Osteosynthesis (MALMOS) Technique With Neutralization H-Plate Fixation
- Where
- Egypt
- Volunteers
- 15 people
- Sponsor
- Assiut University
Humeral Fracture, Proximal
Psychological Health Influences the Choice of Device in Proximal Humeral Fractures
It was conducted a prospective study with a series of 63 patients treated with O.R.I.F. (Open Reduction and Internal Fixation) (group A) and with RSA (Reverse Shoulder Arthroplasty) (group B) for three and four-part proximal…
- Trial name
- NCT04821180
- Testing
- Three and four-part proximal humeral fractures' treatment
- Volunteers
- 63 people
- Sponsor
- Azienda Ospedaliero-Universitaria Consorziale Policlinico di Bari
Distal Radius Fractures
Volar Locking Plate vs Fragment Specific Fixation in Wrist Fractures
The treatment of unstable, non-reducible distal radial fractures is still controversial. The aim of the present study is to compare the subjective, clinical and radiographic outcome of the TriMed fragment-specific system with a…
- Trial name
- NCT01311531
- Testing
- Open reduction and fixation with TriMed fragment-specific system, Open reduction and fixation with TriMed volar locking plate
- Where
- Sweden
- Volunteers
- 50 people
- Sponsor
- Region Skane
Distal Radius Fracture
Paper- vs Digital Application-based Exercises to Support Rehabilitation After Osteosynthesis of Distal Radius Fracture
The aim of this study is to evaluate the difference between the use of paper- versus application-based (smartphone application) exercises in the rehabilitation of intra-articular fractures of the distal radius at the Cantonal…
- Trial name
- NCT06005857
- Testing
- Standard hand therapy + home digital application-based exercises, standard hand therapy + home paper-based exercises
- Where
- Switzerland
- Volunteers
- 40 people
- Sponsor
- Hôpital Fribourgeois
Lisfranc Injuries
Arthrodesis Versus Extra-articular Plate Fixation in Lisfranc Injury
The purpose of this study is to compare arthrodesis of the first TMT-joint to extraarticular bridge plate fixation of the same joint in acute Lisfranc injuries.
- Trial name
- NCT01448941
- Testing
- Temporary extraarticular plate fixation, Primary arthrodesis, Primary arthrodesis TMT 2 and 3
- Where
- Norway
- Volunteers
- 48 people
- Sponsor
- Oslo University Hospital
Distal Femur Fractures
Dynamic Locking Screws 5.0 vs. Standard Locking Screws in Fracture of Distal Femur Treated With Locked Plate Fixation
The purpose of this study is to evaluate the performance of Dynamic Locking Screws (DLS) used to stabilize the shaft component of distal femur fractures in comparison to standard locking screws (SLS).
- Trial name
- NCT01693367
- Testing
- DLS 5.0 (Dynamic locking screws), SLS (Standard locking screw)
- Where
- 12 sites in United States, Austria and 2 more
- Volunteers
- 5 people
- Sponsor
- AO Innovation Translation Center
Coronary Artery Disease, Angina Pectoris
An Evaluation of Rigid Sternal Fixation in Supporting Bone Healing and Improving Postoperative Recovery
The primary objective of this study is to evaluate sternal bone healing following a full median sternotomy versus standard of care for sternal closure with wire cerclage.
- Conditions
- Coronary Artery Disease, Angina Pectoris, Cardiac Valve Disease
- Trial name
- SB (NCT01783483)
- Testing
- SternaLock Blue closure system, Suture Wire
- Where
- 12 sites in United States
- Volunteers
- 236 people
- Sponsor
- Zimmer Biomet
Distal Tibial Fracture, Tibial Fracture
Elastic Nailing With Kirschner Wires Versus Plate Fixation for Distal Tibial Fractures in Adolescents
This prospective randomized controlled trial will compare two surgical methods for treating distal tibial metaphyseal-diaphyseal junction fractures in adolescents aged 10 to 16 years.
- Conditions
- Distal Tibial Fracture, Tibial Fracture, Fracture Fixation, Intramedullary, Fracture Fixation, Internal
- Trial name
- NCT07783529
- Testing
- Elastic Stable Intramedullary Nailing Supplemented by Kirschner Wires, Plate fixation
- Where
- Egypt
- Volunteers
- 60 people
- Sponsor
- Sohag University
Anterior Mandibular Fracture
Evaluation of Condylar Position After Anterior Mandibular Fracture Fixation Using Plates Versus Headless Compression Screws
This study compares two methods for fixing fractures of the front part of the lower jaw: Conventional plates and screws Headless compression screws Patients are randomly assigned to one of the two treatment groups.
- Trial name
- fracture (NCT07826403)
- Testing
- headless compression screw, conventional plates
- Volunteers
- 16 people, healthy volunteers welcome
- Sponsor
- Cairo University
Fixation of Lateral Malleolus in Ankle Fracture Type A&B by Plate Versus Intramedullary Screw
Plate Versus Intramedullary Screw for Lateral Malleolus Fracture in Ankle Fracture Type A&B
The aim of this study is to compare the short term : Clinical, radiographic and functional outcome, and healing time and rate of complications between fixation of lateral malleolar fracture in Danis_Weber_A\&B fracture ankle by…
- Trial name
- NCT07447336
- Testing
- Fixation of lateral malleolar fracture in Danis_Weber_A&B fracture ankle by plate versus intramedullary screw fixation
- Where
- Egypt
- Volunteers
- 52 people
- Sponsor
- Sohag University
Shoulder Fractures, Humeral Fractures, Proximal
Plate Fixation Versus Intramedullary Nailing of 3 and 4 Part Proximal Humerus Fractures
The purpose of the project is to compare the management of 3 and 4 part proximal humerus fractures (PHF) with an angular stable plate (Philos) with that of an intramedullary nail (Multiloc) in light of complications…
- Trial name
- NCT02944058
- Testing
- Multiloc nail, Philos plate
- Where
- Norway
- Volunteers
- 79 people
- Sponsor
- University Hospital, Akershus
Evaluation of Isolated Stoppa Approach in BC Fracture Acetabulum
Stoppa Approach Vs Anterior & Posterior Fixation in Management of BC Fracture Acetabulum
Double-column acetabular fractures are complex injuries that require stable anatomical reduction and fixation to restore hip function.
- Trial name
- RCT (NCT07896044)
- Testing
- Sequential anterior and posterior approaches for double column acetabular fractures, Isolated Modified Stoppa approach for management of double column acetabular fractures
- Where
- Egypt
- Volunteers
- 60 people
- Sponsor
- Ain Shams University
Fractures, Closed
Volar Plate vs. Conventus DRS Fixation
Open reduction and internal fixation (ORIF) of unstable distal radius fractures is performed using a variety of fixation techniques. The most common method is fixed angle volar plate application.
- Trial name
- NCT02390856
- Testing
- Conventus DRS, Volar Plate
- Where
- United States
- Volunteers
- 12 people
- Sponsor
- Hospital for Special Surgery, New York
Surgery
Inion OTPS Biodegradable Fixation System for the Ankle
The purpose of the investigation is to compare post-operative fracture and wound healing using Inion OTPS Biodegradable Fixation System implants versus Conventional metal implants.
- Trial name
- NCT00300989
- Testing
- Inion OTPS Biodegradable Fixation System
- Where
- Finland
- Volunteers
- 43 people
- Sponsor
- Inion Oy
Le Fort; I
Accuracy of LeFort I Osteotomy Fixation Using Two Plates Versus Four Plates Patient Specific Osteosynthesis
Virtual Surgical planning (VSP) has significantly improved many aspects of oral and maxillofacial surgery. A very important aspect is surgical accuracy and precise transfer of the surgical plan to the operating theatre and…
- Trial name
- NCT05908370
- Testing
- Maxillary orthognathic surgery using 4 patient specific osteosynthesis (4-Plates)
- Where
- Egypt
- Volunteers
- 22 people, healthy volunteers welcome
- Sponsor
- Future University in Egypt
Reduction Deformity of Limb
Lumbopelvic Fixation Versus Novel Adjustable Plate for Displaced Sacral Fracture
Patients of unilaterally displaced sacral fractures fixed with lumbopelvic technique or novel adjustable plate from June 2011 to June 2017 were recruited into this study and were divided into two groups: group A (lumbopelvic…
- Trial name
- NCT03647410
- Testing
- lumbopelvic fixation
- Where
- China
- Volunteers
- 20 people
- Sponsor
- Hebei Medical University Third Hospital